Benno H. W. Hendriks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Benno H. W. Hendriks has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Theodoor J. M. Ruers
Netherlands Cancer Institute
3 shared publications - Frederieke H. van Duijnhoven
Department of Surgical Oncology, Netherlands Cancer Institute–Antoni van Leeuwenhoek, Amsterdam, The Netherlands
2 shared publications - Henricus J. C. M. Sterenborg
Department of Surgery, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX Amsterdam, The Netherlands
2 shared publications - Lisanne L. de Boer
Netherlands Cancer Institute-Antoni van Leeuwenhoek, Amsterdam, the Netherlands
2 shared publications - Marie-Jeanne Tertia Francoise Daphne Vrancken Peeters
Department of Surgical Oncology, Netherlands Cancer Institute - Antoni van Leeuwenhoek, Plesmanlaan 121, 1066, CX, Amsterdam, the Netherlands; Department of Surgery, Amsterdam University Medical Center, Meibergdreef 9, 1105, AZ, Amsterdam, the Netherlands
2 shared publications - Torre M. Bydlon
Philips Research North America, Cambridge, MA 02141, USA
2 shared publications
Latest Publications
- Open Access
- 8 January 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (1) , 61
Fiber-Optic Pedicle Probes to Advance Spine Surgery through Diffuse Reflectance Spectroscopy
Diffuse Reflectance Spectroscopy (DRS) can provide tissue feedback for pedicle screw placement in spine surgery, yet the integration of fiber optics into the tip of the pedicle probe, a device used to pierce through bone, is challenging, since the optical probing depth and signal-to-noise ratio (SNR) are affected negatively compared to those of a blunt DRS probe. Through Monte Carlo simulations and optical phantom experiments, we show how differences in the shape of the instrument tip influence the acquired spectrum. Our findings demonstrate that a single bevel with an angle of offers a solution to anticipate cortical breaches during pedicle screw placement. Compared to a blunt probe, the optical probing depth and SNR of a cone tip are reduced by 50%. The single bevel tip excels with 75% of the optical probing depth and a SNR remaining at approximately ⅔, facilitating the construction of a surgical instrument with integrated DRS.- 8 January 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (1) , 61
Open AccessFiber-Optic Pedicle Probes to Advance Spine Surgery through Diffuse Reflectance Spectroscopy
Diffuse Reflectance Spectroscopy (DRS) can provide tissue feedback for pedicle screw placement in spine surgery, yet the integration of fiber optics into the tip of the pedicle probe, a device used to pierce through bone, is challenging, since the optical probing depth and signal-to-noise ratio (SNR) are affected negatively compared to those of a blunt DRS probe. Through Monte Carlo simulations and optical phantom experiments, we show how differences in the shape of the instrument tip influence the acquired spectrum. Our findings demonstrate that a single bevel with an angle of offers a solution to anticipate cortical breaches during pedicle screw placement. Compared to a blunt probe, the optical probing depth and SNR of a cone tip are reduced by 50%. The single bevel tip excels with 75% of the optical probing depth and a SNR remaining at approximately ⅔, facilitating the construction of a surgical instrument with integrated DRS. - Open Access
- 31 March 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (4) , 94
Imaging PPG for In Vivo Human Tissue Perfusion Assessment during Surgery
Surgical excision is the golden standard for treatment of intestinal tumors. In this surgical procedure, inadequate perfusion of the anastomosis can lead to postoperative complications, such as anastomotic leakages. Imaging photoplethysmography (iPPG) can potentially provide objective and real-time feedback of the perfusion status of tissues. This feasibility study aims to evaluate an iPPG acquisition system during intestinal surgeries to detect the perfusion levels of the microvasculature tissue bed in different perfusion conditions. This feasibility study assesses three patients that underwent resection of a portion of the small intestine. Data was acquired from fully perfused, non-perfused and anastomosis parts of the intestine during different phases of the surgical procedure. Strategies for limiting motion and noise during acquisition were implemented. iPPG perfusion maps were successfully extracted from the intestine microvasculature, demonstrating that iPPG can be successfully used for detecting perturbations and perfusion changes in intestinal tissues during surgery. This study provides proof of concept for iPPG to detect changes in organ perfusion levels.
- 31 March 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (4) , 94
Open AccessImaging PPG for In Vivo Human Tissue Perfusion Assessment during Surgery
Surgical excision is the golden standard for treatment of intestinal tumors. In this surgical procedure, inadequate perfusion of the anastomosis can lead to postoperative complications, such as anastomotic leakages. Imaging photoplethysmography (iPPG) can potentially provide objective and real-time feedback of the perfusion status of tissues. This feasibility study aims to evaluate an iPPG acquisition system during intestinal surgeries to detect the perfusion levels of the microvasculature tissue bed in different perfusion conditions. This feasibility study assesses three patients that underwent resection of a portion of the small intestine. Data was acquired from fully perfused, non-perfused and anastomosis parts of the intestine during different phases of the surgical procedure. Strategies for limiting motion and noise during acquisition were implemented. iPPG perfusion maps were successfully extracted from the intestine microvasculature, demonstrating that iPPG can be successfully used for detecting perturbations and perfusion changes in intestinal tissues during surgery. This study provides proof of concept for iPPG to detect changes in organ perfusion levels.
- 1 October 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 14 (4)
Improving Endo-Myocardial Biopsy by Real-Time Spectral Tissue Sensing: A Feasibility Study
The aim of this research is to integrate spectral tissue sensing technology inside a cardiac bioptome for real-time measurements of tissue characteristics. Bioptome tip and handle components were designed and manufactured to house and guide optical fibers. The designed components were assembled on a cardiac bioptome together with optical fibers. A technical feasibility test was carried out to study the functionality of the instrument and the effect of the optical technology on the biopsy performance. Biopsy samples were taken from five different tissue types in a porcine heart and the resulting optical spectra were compared. Spectral tissue sensing fibers were successfully integrated inside a conventional cardiac bioptome. The integrated instrument allowed differentiation between ventricular tissue, blood, and cardiac fat tissue based on blood and fat percentage and amount of scattering. Moreover, differences between scarred and nonscarred tissue were clearly visible. A first step has been made in the use of spectral tissue sensing for the detection of different tissue structures for endo-myocardial biopsy (EMB). The instrument was able to differentiate between various tissues, as well as between healthy and diseased cardiac tissues. Future research should focus on measurements of naturally diseased cardiac tissue, repeated measurements with statistical value, and improvements to the instrument design. Having the ability to measure tissue characteristics prior to acquiring a biopsy sample will not only allow easier positioning of the bioptome at the correct location but can also prevent sampling undesired tissue or scar tissue from previous biopsies.
- 1 October 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 14 (4)
Improving Endo-Myocardial Biopsy by Real-Time Spectral Tissue Sensing: A Feasibility Study
The aim of this research is to integrate spectral tissue sensing technology inside a cardiac bioptome for real-time measurements of tissue characteristics. Bioptome tip and handle components were designed and manufactured to house and guide optical fibers. The designed components were assembled on a cardiac bioptome together with optical fibers. A technical feasibility test was carried out to study the functionality of the instrument and the effect of the optical technology on the biopsy performance. Biopsy samples were taken from five different tissue types in a porcine heart and the resulting optical spectra were compared. Spectral tissue sensing fibers were successfully integrated inside a conventional cardiac bioptome. The integrated instrument allowed differentiation between ventricular tissue, blood, and cardiac fat tissue based on blood and fat percentage and amount of scattering. Moreover, differences between scarred and nonscarred tissue were clearly visible. A first step has been made in the use of spectral tissue sensing for the detection of different tissue structures for endo-myocardial biopsy (EMB). The instrument was able to differentiate between various tissues, as well as between healthy and diseased cardiac tissues. Future research should focus on measurements of naturally diseased cardiac tissue, repeated measurements with statistical value, and improvements to the instrument design. Having the ability to measure tissue characteristics prior to acquiring a biopsy sample will not only allow easier positioning of the bioptome at the correct location but can also prevent sampling undesired tissue or scar tissue from previous biopsies.
- Open Access
- 26 November 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (11) , 115004-12
Influence of neoadjuvant chemotherapy on diffuse reflectance spectra of tissue in breast surgery specimens
Diffuse reflectance spectroscopy (DRS) is an optical technology that measures the composition and morphology of tissue, based on absorption and scattering of light. A DRS measurement of tissue can be used to discriminate tissue types, as the optical characteristics differ between tissue types. The ability to discern healthy tissue from tumor tissue could potentially improve intraoperative margin evaluation during breast-conserving surgery and reduce the number of re-excisions, which are currently reported to be as high as 20% of patients.1 – 6
- 26 November 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (11) , 115004-12
Open AccessInfluence of neoadjuvant chemotherapy on diffuse reflectance spectra of tissue in breast surgery specimens
Diffuse reflectance spectroscopy (DRS) is an optical technology that measures the composition and morphology of tissue, based on absorption and scattering of light. A DRS measurement of tissue can be used to discriminate tissue types, as the optical characteristics differ between tissue types. The ability to discern healthy tissue from tumor tissue could potentially improve intraoperative margin evaluation during breast-conserving surgery and reduce the number of re-excisions, which are currently reported to be as high as 20% of patients.1 – 6
- Open Access
- 19 December 2018
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 16 (1) , 367
Towards the use of diffuse reflectance spectroscopy for real-time in vivo detection of breast cancer during surgery
Background: Breast cancer surgeons struggle with differentiating healthy tissue from cancer at the resection margin during surgery. We report on the feasibility of using diffuse reflectance spectroscopy (DRS) for real-time in vivo tissue characterization. Methods: Evaluating feasibility of the technology requires a setting in which measurements, imaging and pathology have the best possible correlation. For this purpose an optical biopsy needle was used that had integrated optical fibers at the tip of the needle. This approach enabled the best possible correlation between optical measurement volume and tissue histology. With this optical biopsy needle we acquired real-time DRS data of normal tissue and tumor tissue in 27 patients that underwent an ultrasound guided breast biopsy procedure. Five additional patients were measured in continuous mode in which we obtained DRS measurements along the entire biopsy needle trajectory. We developed and compared three different support vector machine based classification models to classify the DRS measurements. Results: With DRS malignant tissue could be discriminated from healthy tissue. The classification model that was based on eight selected wavelengths had the highest accuracy and Matthews Correlation Coefficient (MCC) of 0.93 and 0.87, respectively. In three patients that were measured in continuous mode and had malignant tissue in their biopsy specimen, a clear transition was seen in the classified DRS measurements going from healthy tissue to tumor tissue. This transition was not seen in the other two continuously measured patients that had benign tissue in their biopsy specimen. Conclusions: It was concluded that DRS is feasible for integration in a surgical tool that could assist the breast surgeon in detecting positive resection margins during breast surgery. Trail registration NIH US National Library of Medicine–clinicaltrails.gov, NCT01730365. Registered: 10/04/2012 https://clinicaltrials.gov/ct2/show/study/NCT01730365
- 19 December 2018
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 16 (1) , 367
Open AccessTowards the use of diffuse reflectance spectroscopy for real-time in vivo detection of breast cancer during surgery
Background: Breast cancer surgeons struggle with differentiating healthy tissue from cancer at the resection margin during surgery. We report on the feasibility of using diffuse reflectance spectroscopy (DRS) for real-time in vivo tissue characterization. Methods: Evaluating feasibility of the technology requires a setting in which measurements, imaging and pathology have the best possible correlation. For this purpose an optical biopsy needle was used that had integrated optical fibers at the tip of the needle. This approach enabled the best possible correlation between optical measurement volume and tissue histology. With this optical biopsy needle we acquired real-time DRS data of normal tissue and tumor tissue in 27 patients that underwent an ultrasound guided breast biopsy procedure. Five additional patients were measured in continuous mode in which we obtained DRS measurements along the entire biopsy needle trajectory. We developed and compared three different support vector machine based classification models to classify the DRS measurements. Results: With DRS malignant tissue could be discriminated from healthy tissue. The classification model that was based on eight selected wavelengths had the highest accuracy and Matthews Correlation Coefficient (MCC) of 0.93 and 0.87, respectively. In three patients that were measured in continuous mode and had malignant tissue in their biopsy specimen, a clear transition was seen in the classified DRS measurements going from healthy tissue to tumor tissue. This transition was not seen in the other two continuously measured patients that had benign tissue in their biopsy specimen. Conclusions: It was concluded that DRS is feasible for integration in a surgical tool that could assist the breast surgeon in detecting positive resection margins during breast surgery. Trail registration NIH US National Library of Medicine–clinicaltrails.gov, NCT01730365. Registered: 10/04/2012 https://clinicaltrials.gov/ct2/show/study/NCT01730365
- Open Access
- 16 November 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (11) , 1-10
Real-time oncological guidance using diffuse reflectance spectroscopy in electrosurgery: the effect of coagulation on tissue discrimination
In breast surgery, a lack of knowledge about what is below the tissue surface may lead to positive tumor margins and iatrogenic damage. Diffuse reflectance spectroscopy (DRS) is a spectroscopic technique that can distinguish between healthy and tumor tissue making it a suitable technology for intraoperative guidance. However, because tumor surgeries are often performed with an electrosurgical knife, the effect of a coagulated tissue layer on DRS measurements must be taken into account. It is evaluated whether real-time DRS measurements obtained with a photonic electrosurgical knife could provide useful information of tissue properties also when tissue is coagulated and cut. The size of the coagulated area is determined and the effect of its presence on DR spectra is studied using ex vivo porcine adipose and muscle tissue. A coagulated tissue layer with a depth of 0.1 to 0.4 mm is observed after coagulating muscle with an electrosurgical knife. The results show that the effect of coagulating adipose tissue is negligible. Using the fat/water ratio’s calculated from the measured spectra of the photonic electrosurgical knife, it was possible to determine the distance from the instrument tip to a tissue transition during cutting. In conclusion, the photonic electrosurgical knife can determine tissue properties of coagulated and cut tissue and has, therefore, the potential to provide real-time feedback about the presence of breast tumor margins during cutting, helping surgeons to establish negative margins and improve patient outcome.
- 16 November 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 23 (11) , 1-10
Open AccessReal-time oncological guidance using diffuse reflectance spectroscopy in electrosurgery: the effect of coagulation on tissue discrimination
In breast surgery, a lack of knowledge about what is below the tissue surface may lead to positive tumor margins and iatrogenic damage. Diffuse reflectance spectroscopy (DRS) is a spectroscopic technique that can distinguish between healthy and tumor tissue making it a suitable technology for intraoperative guidance. However, because tumor surgeries are often performed with an electrosurgical knife, the effect of a coagulated tissue layer on DRS measurements must be taken into account. It is evaluated whether real-time DRS measurements obtained with a photonic electrosurgical knife could provide useful information of tissue properties also when tissue is coagulated and cut. The size of the coagulated area is determined and the effect of its presence on DR spectra is studied using ex vivo porcine adipose and muscle tissue. A coagulated tissue layer with a depth of 0.1 to 0.4 mm is observed after coagulating muscle with an electrosurgical knife. The results show that the effect of coagulating adipose tissue is negligible. Using the fat/water ratio’s calculated from the measured spectra of the photonic electrosurgical knife, it was possible to determine the distance from the instrument tip to a tissue transition during cutting. In conclusion, the photonic electrosurgical knife can determine tissue properties of coagulated and cut tissue and has, therefore, the potential to provide real-time feedback about the presence of breast tumor margins during cutting, helping surgeons to establish negative margins and improve patient outcome.
- Open Access
- 15 December 2015
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 13 (1) , 1-11
Nerve detection with optical spectroscopy for regional anesthesia procedures
Regional anesthesia has several advantages over general anesthesia but requires accurate needle placement to be effective. To achieve accurate placement, a needle equipped with optical fibers that allows tissue discrimination at the needle tip based on optical spectroscopy is proposed. This study investigates the sensitivity and specificity with which this optical needle can discriminate nerves from the surrounding tissues making use of different classification methods. Diffuse reflectance spectra were acquired from 1563 different locations from 19 human cadavers in the wavelength range of 400–1710 nm; measured tissue types included fascicular tissue of the nerve, muscle, sliding fat and subcutaneous fat. Physiological parameters of the tissues were derived from the measured spectra and part of the data was directly compared to histology. Various classification methods were then applied to the derived parameter dataset to determine the accuracy with which fascicular tissue of the nerve can be discriminated from the surrounding tissues. From the parameters determined from the measured spectra of the various tissues surrounding the nerve, fat content, blood content, beta-carotene content and scattering were most distinctive when comparing fascicular and non-fascicular tissue. Support Vector Machine classification with a combination of feature selections performed best in discriminating fascicular nerve tissue from the surrounding tissues with a sensitivity and specificity around 90 %. This study showed that spectral tissue sensing, based on diffuse reflectance spectroscopy at the needle tip, is a promising technique to discriminate fascicular tissue of the nerve from the surrounding tissues. The technique may therefore improve accurate needle placement near the nerve which is necessary for effective nerve blocks in regional anesthesia.
- 15 December 2015
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 13 (1) , 1-11
Open AccessNerve detection with optical spectroscopy for regional anesthesia procedures
Regional anesthesia has several advantages over general anesthesia but requires accurate needle placement to be effective. To achieve accurate placement, a needle equipped with optical fibers that allows tissue discrimination at the needle tip based on optical spectroscopy is proposed. This study investigates the sensitivity and specificity with which this optical needle can discriminate nerves from the surrounding tissues making use of different classification methods. Diffuse reflectance spectra were acquired from 1563 different locations from 19 human cadavers in the wavelength range of 400–1710 nm; measured tissue types included fascicular tissue of the nerve, muscle, sliding fat and subcutaneous fat. Physiological parameters of the tissues were derived from the measured spectra and part of the data was directly compared to histology. Various classification methods were then applied to the derived parameter dataset to determine the accuracy with which fascicular tissue of the nerve can be discriminated from the surrounding tissues. From the parameters determined from the measured spectra of the various tissues surrounding the nerve, fat content, blood content, beta-carotene content and scattering were most distinctive when comparing fascicular and non-fascicular tissue. Support Vector Machine classification with a combination of feature selections performed best in discriminating fascicular nerve tissue from the surrounding tissues with a sensitivity and specificity around 90 %. This study showed that spectral tissue sensing, based on diffuse reflectance spectroscopy at the needle tip, is a promising technique to discriminate fascicular tissue of the nerve from the surrounding tissues. The technique may therefore improve accurate needle placement near the nerve which is necessary for effective nerve blocks in regional anesthesia.
- Open Access
- 21 September 2015
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 13 (1) , 1-11
Diffuse reflectance spectroscopy accurately quantifies various degrees of liver steatosis in murine models of fatty liver disease
A real-time objective evaluation for the extent of liver steatosis during liver transplantation is currently not available. Diffuse reflectance spectroscopy (DRS) rapidly and accurately assesses the extent of steatosis in human livers with mild steatosis. However, it is yet unknown whether DRS accurately quantifies moderate/severe steatosis and is able to distinguish between micro- and macrovesicular steatosis. C57BL/6JolaHsd mice were fed wit a choline-deficient l-amino acid-defined diet (CD-AA) or a choline-sufficient l-amino acid-defined control diet (CS-AA) for 3, 8, and 20 weeks. In addition B6.V-Lepob/OlaHsd (ob/ob) mice and their lean controls were studied. A total of 104 DRS measurements were performed in liver tissue ex vivo. The degree of steatosis was quantified from the DRS data and compared with histopathological analysis. When assessed by histology, livers of mice fed with a CD-AA and CS-AA diet displayed macrovesicular steatosis (range 0–74 %), ob/ob mice revealed only microvesicular steatosis (range 75–80 %), and their lean controls showed no steatosis. The quantification of steatosis by DRS correlated well with pathology (correlation of 0.76 in CD-AA/CS-AA fed mice and a correlation of 0.75 in ob/ob mice). DRS spectra did not distinguish between micro- and macrovesicular steatosis. In samples from CD-AA/CS-AA fed mice, the DRS was able to distinguish between mild and moderate/severe steatosis with a sensitivity and specificity of 86 and 81 %, respectively. DRS can quantify steatosis with good agreement to histopathological analysis. DRS may be useful for real-time objective evaluation of liver steatosis during liver transplantation, especially to differentiate between mild and moderate/severe steatosis.
- 21 September 2015
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 13 (1) , 1-11
Open AccessDiffuse reflectance spectroscopy accurately quantifies various degrees of liver steatosis in murine models of fatty liver disease
A real-time objective evaluation for the extent of liver steatosis during liver transplantation is currently not available. Diffuse reflectance spectroscopy (DRS) rapidly and accurately assesses the extent of steatosis in human livers with mild steatosis. However, it is yet unknown whether DRS accurately quantifies moderate/severe steatosis and is able to distinguish between micro- and macrovesicular steatosis. C57BL/6JolaHsd mice were fed wit a choline-deficient l-amino acid-defined diet (CD-AA) or a choline-sufficient l-amino acid-defined control diet (CS-AA) for 3, 8, and 20 weeks. In addition B6.V-Lepob/OlaHsd (ob/ob) mice and their lean controls were studied. A total of 104 DRS measurements were performed in liver tissue ex vivo. The degree of steatosis was quantified from the DRS data and compared with histopathological analysis. When assessed by histology, livers of mice fed with a CD-AA and CS-AA diet displayed macrovesicular steatosis (range 0–74 %), ob/ob mice revealed only microvesicular steatosis (range 75–80 %), and their lean controls showed no steatosis. The quantification of steatosis by DRS correlated well with pathology (correlation of 0.76 in CD-AA/CS-AA fed mice and a correlation of 0.75 in ob/ob mice). DRS spectra did not distinguish between micro- and macrovesicular steatosis. In samples from CD-AA/CS-AA fed mice, the DRS was able to distinguish between mild and moderate/severe steatosis with a sensitivity and specificity of 86 and 81 %, respectively. DRS can quantify steatosis with good agreement to histopathological analysis. DRS may be useful for real-time objective evaluation of liver steatosis during liver transplantation, especially to differentiate between mild and moderate/severe steatosis.
- Open Access
- 1 January 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (2) , 026007-026007-8
High-resolution resonant and nonresonant fiber-scanning confocal microscope
We present a novel, hand-held microscope probe for acquiring confocal images of biological tissue. This probe generates images by scanning a fiber-lens combination with a miniature electromagnetic actuator, which allows it to be operated in resonant and nonresonant scanning modes. In the resonant scanning mode, a circular field of view with a diameter of 190 μm and an angular frequency of 127 Hz can be achieved. In the nonresonant scanning mode, a maximum field of view with a width of 69 μm can be achieved. The measured transverse and axial resolutions are 0.60 and 7.4 μm, respectively. Images of biological tissue acquired in the resonant mode are presented, which demonstrate its potential for real-time tissue differentiation. With an outer diameter of 3 mm, the microscope probe could be utilized to visualize cellular microstructures in vivo across a broad range of minimally-invasive procedures.
- 1 January 2011
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 16 (2) , 026007-026007-8
Open AccessHigh-resolution resonant and nonresonant fiber-scanning confocal microscope
We present a novel, hand-held microscope probe for acquiring confocal images of biological tissue. This probe generates images by scanning a fiber-lens combination with a miniature electromagnetic actuator, which allows it to be operated in resonant and nonresonant scanning modes. In the resonant scanning mode, a circular field of view with a diameter of 190 μm and an angular frequency of 127 Hz can be achieved. In the nonresonant scanning mode, a maximum field of view with a width of 69 μm can be achieved. The measured transverse and axial resolutions are 0.60 and 7.4 μm, respectively. Images of biological tissue acquired in the resonant mode are presented, which demonstrate its potential for real-time tissue differentiation. With an outer diameter of 3 mm, the microscope probe could be utilized to visualize cellular microstructures in vivo across a broad range of minimally-invasive procedures.
- 10 December 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (35) , 6548-6560
Application of nonperiodic phase structures in optical systems
Wide, nonperiodic stepped phase structures are studied to correct various parameter-dependent wave-front aberrations in optical systems. The wide nature of these phase structures makes them easy to manufacture with sufficient compensation of the wave-front aberrations. Wave-front aberration correction for both continuous and discrete parameter variations are studied. An analytical method is derived for the discrete parameter variations to find the optimal phase structure. Both theoretical and experimental results show that these nonperiodic phase structures can be used to make (1) lenses athermal (defocus and spherical aberration compensated), (2) lenses achromatic, (3) lenses with a large field of view, (4) lenses with a reduced field curvature, and (5) digital versatile disk objective lenses for optical recording that are compatible with compact disk readout.
- 10 December 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (35) , 6548-6560
Application of nonperiodic phase structures in optical systems
Wide, nonperiodic stepped phase structures are studied to correct various parameter-dependent wave-front aberrations in optical systems. The wide nature of these phase structures makes them easy to manufacture with sufficient compensation of the wave-front aberrations. Wave-front aberration correction for both continuous and discrete parameter variations are studied. An analytical method is derived for the discrete parameter variations to find the optimal phase structure. Both theoretical and experimental results show that these nonperiodic phase structures can be used to make (1) lenses athermal (defocus and spherical aberration compensated), (2) lenses achromatic, (3) lenses with a large field of view, (4) lenses with a reduced field curvature, and (5) digital versatile disk objective lenses for optical recording that are compatible with compact disk readout.