Marshall B. Long
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marshall B. Long has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Joseph Fielding
J. Fielding and M. B. Longare with the Center for Laser Diagnostics, Department of Mechanical Engineering, Yale University, New Haven, Connecticut 06520-8284.G. Fielding is with the Imaging Science Division, Eastman Kodak Company, Rochester, New York 14650.M. Komiyama is with the Department of Mechanical Engineering, Osaka University, Osaka, Japan
2 shared publicationsGabriel Fielding
J. Fielding and M. B. Longare with the Center for Laser Diagnostics, Department of Mechanical Engineering, Yale University, New Haven, Connecticut 06520-8284.G. Fielding is with the Imaging Science Division, Eastman Kodak Company, Rochester, New York 14650.M. Komiyama is with the Department of Mechanical Engineering, Osaka University, Osaka, Japan
1 shared publicationJonathan H. Frank
Combustion Research Facility, Sandia National Laboratories, P.O. Box 969, Livermore, California 94551
1 shared publicationKevin T. Walsh
Department of Mechanical Engineering, Yale University, New Haven, Connecticut 06520-8284
1 shared publicationMasaharu Komiyama
J. Fielding and M. B. Longare with the Center for Laser Diagnostics, Department of Mechanical Engineering, Yale University, New Haven, Connecticut 06520-8284.G. Fielding is with the Imaging Science Division, Eastman Kodak Company, Rochester, New York 14650.M. Komiyama is with the Department of Mechanical Engineering, Osaka University, Osaka, Japan
1 shared publication- Sebastian Arnold Kaiser
EMPI, Institute for Energy and Materials Processes-Reactive Fluids, University of Duisburg-Essen, 47057 Duisburg, Germany
1 shared publication
Latest Publications
- 1 November 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (31) , 6557-6564
Use of Rayleigh imaging and ray tracing to correct for beam-steering effects in turbulent flames
Laser Rayleigh imaging has been applied in a number of flow and flame studies to measure concentration or temperature distributions. Rayleigh cross sections are dependent on the index of refraction of the scattering medium. The same index of refraction changes that provide contrast in Rayleigh images can also deflect the illuminating laser sheet. By applying a ray-tracing algorithm to the detected image, it is possible to correct for some of these beam-steering effects and thereby improve the accuracy of the measured field. Additionally, the quantification of the degree of beam steering through the flow provides information on the degradation of spatial resolution in the measurement. Application of the technique in a well-studied laboratory flame is presented, along with analysis of the effects of image noise and spatial resolution on the effectiveness of the algorithm.
- 1 November 2005
- Published by Optica Publishing Group in Applied Optics
- Vol. 44 (31) , 6557-6564
Use of Rayleigh imaging and ray tracing to correct for beam-steering effects in turbulent flames
Laser Rayleigh imaging has been applied in a number of flow and flame studies to measure concentration or temperature distributions. Rayleigh cross sections are dependent on the index of refraction of the scattering medium. The same index of refraction changes that provide contrast in Rayleigh images can also deflect the illuminating laser sheet. By applying a ray-tracing algorithm to the detected image, it is possible to correct for some of these beam-steering effects and thereby improve the accuracy of the measured field. Additionally, the quantification of the degree of beam steering through the flow provides information on the degradation of spatial resolution in the measurement. Application of the technique in a well-studied laboratory flame is presented, along with analysis of the effects of image noise and spatial resolution on the effectiveness of the algorithm.
- 20 February 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (6) , 757-764
Systematic errors in optical-flow velocimetry for turbulent flows and flames
Optical-flow (OF) velocimetry is based on extracting velocity information from two-dimensional scalar images and represents an unseeded alternative to particle-image velocimetry in turbulent flows. The performance of the technique is examined by direct comparison with simultaneous particle-image velocimetry in both an isothermal turbulent flow and a turbulent flame by use of acetone–OH laser-induced fluorescence. Two representative region-based correlation OF algorithms are applied to assess the general accuracy of the technique. Systematic discrepancies between particle-imaging velocimetry and OF velocimetry are identified with increasing distance from the center line, indicating potential limitations of the current OF techniques. Directional errors are present at all radial positions, with differences in excess of 10° being typical. An experimental measurement setup is described that allows the simultaneous measurement of Mie scattering from seed particles and laser-induced fluorescence on the same CCD camera at two distinct times for validation studies.
- 20 February 2001
- Published by Optica Publishing Group in Applied Optics
- Vol. 40 (6) , 757-764
Systematic errors in optical-flow velocimetry for turbulent flows and flames
Optical-flow (OF) velocimetry is based on extracting velocity information from two-dimensional scalar images and represents an unseeded alternative to particle-image velocimetry in turbulent flows. The performance of the technique is examined by direct comparison with simultaneous particle-image velocimetry in both an isothermal turbulent flow and a turbulent flame by use of acetone–OH laser-induced fluorescence. Two representative region-based correlation OF algorithms are applied to assess the general accuracy of the technique. Systematic discrepancies between particle-imaging velocimetry and OF velocimetry are identified with increasing distance from the center line, indicating potential limitations of the current OF techniques. Directional errors are present at all radial positions, with differences in excess of 10° being typical. An experimental measurement setup is described that allows the simultaneous measurement of Mie scattering from seed particles and laser-induced fluorescence on the same CCD camera at two distinct times for validation studies.
- 1 April 2000
- Published by Optica Publishing Group in Optics Letters
- Vol. 25 (7) , 457-459
Effect of light-collection geometry on reconstruction errors in Abel inversions
The Abel inversion, used to reconstruct axisymmetric radial profiles from line-of-sight intensity measurements, is increasingly used to make spatially resolved combustion measurements. An Abel deconvolution is valid only when incoming rays are parallel, whereas most practical optical setups used for emission imaging consist of single-lens and multilens systems that collect light in a cone, over a nonzero solid angle. A ray-tracing simulation was performed to aid in understanding how optical collection geometry affects measured intensity signals and the resultant reconstructed emissivity profiles. Simulation results are compared with emission tomography measurements performed on an axisymmetric laminar diffusion flame.
- 1 April 2000
- Published by Optica Publishing Group in Optics Letters
- Vol. 25 (7) , 457-459
Effect of light-collection geometry on reconstruction errors in Abel inversions
The Abel inversion, used to reconstruct axisymmetric radial profiles from line-of-sight intensity measurements, is increasingly used to make spatially resolved combustion measurements. An Abel deconvolution is valid only when incoming rays are parallel, whereas most practical optical setups used for emission imaging consist of single-lens and multilens systems that collect light in a cone, over a nonzero solid angle. A ray-tracing simulation was performed to aid in understanding how optical collection geometry affects measured intensity signals and the resultant reconstructed emissivity profiles. Simulation results are compared with emission tomography measurements performed on an axisymmetric laminar diffusion flame.