MBMichael S. Brown

Michael S. Brown

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael S. Brown has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • William L. Roberts

    M. S. Brownis with Innovative Scientific Solutions, Inc., Dayton, Ohio 45440-3638.Y. Li and W. L. Roberts are with the Department of Aerospace and Mechanical Engineering, North Carolina State University, Raleigh, North Carolina 27695-7910.J. R. Gord is with the Propulsion Directorate, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433

    2 shared publications
  • Yuanyuan Li

    M. S. Brownis with Innovative Scientific Solutions, Inc., Dayton, Ohio 45440-3638.Y. Li and W. L. Roberts are with the Department of Aerospace and Mechanical Engineering, North Carolina State University, Raleigh, North Carolina 27695-7910.J. R. Gord is with the Propulsion Directorate, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433

    2 shared publications
  • Ian Critchley

    Honeywell Engines and Systems, Phoenix, AZ

    1 shared publication
  • James R. Gord

    M. S. Brownis with Innovative Scientific Solutions, Inc., Dayton, Ohio 45440-3638.Y. Li and W. L. Roberts are with the Department of Aerospace and Mechanical Engineering, North Carolina State University, Raleigh, North Carolina 27695-7910.J. R. Gord is with the Propulsion Directorate, Air Force Research Laboratory, Wright-Patterson Air Force Base, Ohio 45433

    1 shared publication
  • James R. Gord

    Air Force Research Laboratory

    1 shared publication
  • Jerald A. Caton

    Texas A&M University, College Station, TX

    1 shared publication

Latest Publications

  • Analysis of transient-grating signals for reacting-flow applications

    by Michael S. Brown, Yuanyuan Li, William L. Roberts, James R. Gord

    Single-shot transient-grating measurements for thermometry in pressurized reacting flows are examined in the context of rapid digital signal processing. Simple approaches are discussed for temperature determination and rejection of unwanted signals in real-time measurement applications. Examples of temperature data in pressurized postflame gases are presented in the form of probability-density functions (PDFs). Three contributions to the PDF half-widths are discussed. Analysis of phase-matching requirements indicates that beam steering as a result of density fluctuations affects the signal amplitude but not the grating period. Therefore, such stochastic beam deviations have little effect on the derived temperatures. Mode noise on the cw probe beam as well as linear light scattering are found to be insignificant in the frequency range of the observed transient-grating acoustic signature. Use of a single-mode laser for the pump beams is shown to enhance the signal intensity.


  • Diode-Laser-Based Sensor Measurements of Nitric Oxide and Carbon Monoxide in Combustion Exhaust Streams

    by Thomas N. Anderson, Rodolfo Barron-Jimenez, Jerald A. Caton, Robert P. Lucht, Sukesh Roy, Michael S. Brown, James R. Gord, Thomas Walther, Ian Critchley, Luis Flamand

    All-solid-state continuous-wave (cw) laser systems for ultraviolet (UV) absorption measurements of the nitric oxide (NO) molecule and mid-infrared (IR) absorption measurements of carbon monoxide (CO) were developed and demonstrated. For the NO sensor, 250 nW of tunable cw UV radiation at 226.8 nm is produced by sum-frequency-mixing in a beta-barium borate crystal. For the CO sensor, 2μW of tunable cw IR radiation at 4.5 μm is produced by difference-frequency mixing in a periodically-poled lithium niobate crystal. A tunable external-cavity diode laser (ECDL) provides one of the fundamental beams for both processes so that the wavelength of the generated UV/IR can be tuned over NO/CO absorption lines to produce a fully resolved absorption spectrum. The sensors were used for measurements in the exhaust stream of an operating auxiliary power unit (APU) gas turbine engine and a well-stirred reactor (WSR). During these tests, NO was measured in the exhaust at levels below 10 ppm. For measurements at levels above 20 ppm, the NO emission levels obtained using the new sensor agreed with the results of probe sampling chemiluminescent analyzer results to within 10%. A detection limit of 0.8 ppm of per meter path length at 1000 K is estimated for the NO sensor. Measurements with the CO sensor demonstrated an agreement with extractive probe sampling to within 15%. The estimated detection limit of the CO sensor is a few ppm per meter path length at 1000 K.