David C. Viano
Research Subjects
Research Interests
David C. Viano has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Albert I. King
Bioengineering Center, Wayne State University , Detroit, MI, 48202
1 shared publication- Angela K. Cheney1 shared publication
- Cynthia Bir
Department of Biomedical Engineering, Wayne State University
1 shared publication David H. Janda
1 shared publicationStefan Olsen
1 shared publicationWarren N. Hardy
Bioengineering Center, Wayne State University , Detroit, MI, 48202
1 shared publication
Latest Publications
- 1 November 2001
- Published by Wolters Kluwer Health
- Vol. 51 (5) , 959-969
The Effectiveness of Active Head Restraint in Preventing Whiplash
Whiplash injury claims have increased for two decades and manual head restraints are often incorrectly adjusted. A Self-Aligning Head Restraint (SAHR) was designed to move upward and forward by occupant motion in a rear crash providing earlier neck support, even when the head restraint is positioned low. This study determines its field effectiveness. Insurance records were analyzed for consecutive Saab rear crashes in Sweden over 18 months. The Saab 9000/900 had standard head restraints and Saab 9-5/9-3 had SAHR. A questionnaire was mailed to the occupants, insurance and medical records were reviewed, and phone interviews were conducted. SAHR reduced whiplash injury risks by 75 ± 11% from an 18 ± 5% incidence in 85 occupants with standard head restraints to 4 ± 3% in 92 occupants with SAHR. No SAHR seat required repair or replacement after the crashes. SAHR is effective in reducing whiplash injury in rear crashes and is a passive public-health approach that works irrespective of manual head-restraint adjustment.
- 1 November 2001
- Published by Wolters Kluwer Health
- Vol. 51 (5) , 959-969
The Effectiveness of Active Head Restraint in Preventing Whiplash
Whiplash injury claims have increased for two decades and manual head restraints are often incorrectly adjusted. A Self-Aligning Head Restraint (SAHR) was designed to move upward and forward by occupant motion in a rear crash providing earlier neck support, even when the head restraint is positioned low. This study determines its field effectiveness. Insurance records were analyzed for consecutive Saab rear crashes in Sweden over 18 months. The Saab 9000/900 had standard head restraints and Saab 9-5/9-3 had SAHR. A questionnaire was mailed to the occupants, insurance and medical records were reviewed, and phone interviews were conducted. SAHR reduced whiplash injury risks by 75 ± 11% from an 18 ± 5% incidence in 85 occupants with standard head restraints to 4 ± 3% in 92 occupants with SAHR. No SAHR seat required repair or replacement after the crashes. SAHR is effective in reducing whiplash injury in rear crashes and is a passive public-health approach that works irrespective of manual head-restraint adjustment.
- 1 January 2001
- Published by Taylor & Francis in Journal of Crash Prevention and Injury Control
- Vol. 2 (4) , 289-306
Response of the Head, Neck and Torso to Pendulum Impacts on the Back
Pendulum impacts on the back were conducted to determine human head, neck and torso biomechanics. Eight unembalmed cadavers were subjected to 23.4 kg pendulum impacts at 4.4 m/s and 6.6 m/s at T1 and T6. Twenty-four tests were conducted with accelerometers on the pendulum, spine, torso, and head in the WSU 3-2-2-2 array. High-speed photography was taken. Impact displaces the torso forward, deflects the chest, displaces and rotates the head, and extends the neck. Average responses and corridors were determined for head kinematics and chest force-deflection. The head-neck response occurs in two phases. First, the head displaces upwards and rearwards 30—40 mm with respect to the torso along a 45° trajectory. Head rotation is 1O°-15° with essentially no neck moment, but high neck compression forces. Second, the head rotates from 10°-15° to 40°-55° starting with a rapid rise in neck moment and displaces 80–100 mm rearward. Anterior cervical fractures correlate with neck tension. Rib fractures correlate with impact force and chest deflection. This study provides chest bio-mechanical responses for rear impacts resulting in head displacement and rotation, neck extension and cervical-thoracic injury.
- 1 January 2001
- Published by Taylor & Francis in Journal of Crash Prevention and Injury Control
- Vol. 2 (4) , 289-306
Response of the Head, Neck and Torso to Pendulum Impacts on the Back
Pendulum impacts on the back were conducted to determine human head, neck and torso biomechanics. Eight unembalmed cadavers were subjected to 23.4 kg pendulum impacts at 4.4 m/s and 6.6 m/s at T1 and T6. Twenty-four tests were conducted with accelerometers on the pendulum, spine, torso, and head in the WSU 3-2-2-2 array. High-speed photography was taken. Impact displaces the torso forward, deflects the chest, displaces and rotates the head, and extends the neck. Average responses and corridors were determined for head kinematics and chest force-deflection. The head-neck response occurs in two phases. First, the head displaces upwards and rearwards 30—40 mm with respect to the torso along a 45° trajectory. Head rotation is 1O°-15° with essentially no neck moment, but high neck compression forces. Second, the head rotates from 10°-15° to 40°-55° starting with a rapid rise in neck moment and displaces 80–100 mm rearward. Anterior cervical fractures correlate with neck tension. Rib fractures correlate with impact force and chest deflection. This study provides chest bio-mechanical responses for rear impacts resulting in head displacement and rotation, neck extension and cervical-thoracic injury.
- 1 December 2000
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 49 (6) , 1023-1028
Prevention of Commotio Cordis in Baseball: An Evaluation of Chest Protectors
In a recent study of fatal chest impacts by baseballs, 28% of the children were wearing a chest protector. This study evaluates the effectiveness of chest protectors in reducing the risk of commotio cordis. Five commercially available chest protectors were placed on a three-rib structure simulating the chest and impacted at 40, 50, 60, and 70 miles per hour by a standard baseball. Ten repeated tests were conducted on each vest in random order, and on the control (unprotected chest). The viscous response (or viscous criterion [VC]) was used to assess differences in fatality risk. One vest had a statistically lower VC (average, 50.6%, p < 0.05) for all impact speeds. Three averaged 18.7% to 27.7% lower VC, but were significantly different only at higher speeds. One vest had an average 34.2% higher VC, and was significantly higher at 40 to 50 miles per hour (p < 0.05). A method was proposed linking laboratory test results to real-world incidents of ventricular fibrillation. The majority of commercially available chest protectors fail to provide consistent reductions in commotio cordis risk. Nonetheless, there are benefits from their use in baseball until improved safety equipment is developed and standard tests are established to assess sport equipment effectiveness.
- 1 December 2000
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 49 (6) , 1023-1028
Prevention of Commotio Cordis in Baseball: An Evaluation of Chest Protectors
In a recent study of fatal chest impacts by baseballs, 28% of the children were wearing a chest protector. This study evaluates the effectiveness of chest protectors in reducing the risk of commotio cordis. Five commercially available chest protectors were placed on a three-rib structure simulating the chest and impacted at 40, 50, 60, and 70 miles per hour by a standard baseball. Ten repeated tests were conducted on each vest in random order, and on the control (unprotected chest). The viscous response (or viscous criterion [VC]) was used to assess differences in fatality risk. One vest had a statistically lower VC (average, 50.6%, p < 0.05) for all impact speeds. Three averaged 18.7% to 27.7% lower VC, but were significantly different only at higher speeds. One vest had an average 34.2% higher VC, and was significantly higher at 40 to 50 miles per hour (p < 0.05). A method was proposed linking laboratory test results to real-world incidents of ventricular fibrillation. The majority of commercially available chest protectors fail to provide consistent reductions in commotio cordis risk. Nonetheless, there are benefits from their use in baseball until improved safety equipment is developed and standard tests are established to assess sport equipment effectiveness.