HAHisamitsu Awaki

Hisamitsu Awaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hisamitsu Awaki has a total of 135 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fine structure of the atomic scattering factors near the iridium L-edges

    by Hisamitsu Awaki, Yoshitomo Maeda, Hironori Matsumoto, Marcos Bavdaz, Finn E. Christensen, Maximilien Collon, Desiree D. M. Ferreira, Kazunori Ishibashi, Sonny Massahi, Takuya Miyazawa, et al.

    We measured the reflectivity of an Athena silicon pore optics sample coated with 10-nm thick iridium near the iridium L-edges (L3 , L2, and L1) in a step of 1.5 eV. The derived atomic scattering factor f2 was similar to a shape of the absorption coefficient μ near L3 and L2 obtained by previous x-ray absorption spectroscopy (XAS) measurements. The fine structures of f2 of L3 and L2 can be represented by a strong sharp line referred to as a white line (WL) and two weak lines at center energies of ∼17 and ∼31 eV from each edge energy. The branching ratio (L3 / L2) of the WL is >2, which reflects the initial core-electron states available for the L2 (2p1/2) and L3 (2p3/2) processes, and the ratio remains high to the energy of +7 . 5 eV from WL. The fine structure seen in L1 also has two weak lines, which were seen in XAS at L1-edge. Our measurements near L3, L2, and L1 edges demonstrated a different technique to provide atomic structural information as XAS. The ground calibration to measure fine structures near the edges may potentially be simplified using f2 estimated based on μ.

  • Open Access

    Effect of barrier layer on moisture absorption of thin carbon-fiber-reinforced plastic mirror substrates

    by Hisamitsu Awaki, Tessei Yoshida, Chisato Oue, Nozomi Aida, Hironori Matsumoto, Tomohiro Kamiya

    With the advent of telescopes, it has become possible to detect weak light and detailed structures in the universe that cannot be observed by the human eye. In the x-ray band, many discoveries have been made using x-ray telescopes. Since x-ray optics work in grazing-incidence configuration, the effective area is much smaller than the surface area of the mirror. It is difficult to fabricate the mirrors that have both a high spatial resolution and a large effective area. The design of x-ray telescopes is roughly classified into two types based on the mirror configuration: one type focuses on achieving a high spatial resolution,1 – 3 while the other focuses on achieving a large effective area.4 – 12 To respond to recent scientific requirements, future large facilities such as Athena and Lynx should achieve an angular resolution much better than 30 arc sec [5 arc sec half-energy diameter (HED) for Athena,13 0.5 arc sec HED for Lynx14].


  • Hard x-ray telescopes to be onboard ASTRO-H

    by Hisamitsu Awaki, Hideyo Kunieda, Manabu Ishida, Hironori Matsumoto, Yasunori Babazaki, Tadatsugu Demoto, Akihiro Furuzawa, Yoshito Haba, Takayuki Hayashi, Ryo Iizuka, et al.

    The new Japanese x-ray astronomy satellite, ASTRO-H, will carry two identical hard x-ray telescopes (HXTs), which cover the energy range of 5 to 80 keV. The HXT mirrors employ tightly nested, conically approximated thin-foil Wolter-I optics, and the mirror surfaces are coated with Pt/C depth-graded multilayers to enhance the hard x-ray effective area by means of Bragg reflection. The HXT comprises foils 120–450 mm in diameter and 200 mm in length, with a focal length of 12 m. To obtain a large effective area, 213 aluminum foils 0.2 mm in thickness are tightly nested confocally. The requirements for HXT are a total effective area of >300  cm2 at 30 keV and an angular resolution of <1.7′ in half-power diameter (HPD). Fabrication of two HXTs has been completed, and the x-ray performance of each HXT was measured at a synchrotron radiation facility, SPring-8 BL20B2 in Japan. Angular resolutions (HPD) of 1.9′ and 1.8′ at 30 keV were obtained for the full telescopes of HXT-1 and HXT-2, respectively. The total effective area of the two HXTs at 30 keV is 349  cm2.


  • Recent results of hard x-ray characterization of ASTRO-H HXT at SPring-8

    by Takuya Miyazawa, Naoki Ishida, Hiroyoshi Kato, Tadatsugu Demoto, Tsuyoshi Watanabe, Yuuji Kuroda, Fumiya Shimasaki, Shunya Takizawa, Yoshito Haba, Keisuke Tamura, et al.

    We present recent results of hard X-ray characterization of ASTRO-H HXT at SPring-8. The HXT onboard ASTRO-H is thin-foil, multi-nested conical optics similar to the Suzaku X-ray telescope. To reflect hard X-rays efficiently, reflector surface is coated with depth-graded Pt/C multilayer. The integraion of the HXT-1 mirror module has been completed. This mirror module has been characterized at a synchrotron radiation facility, SPring-8 beamline BL20B2. We have adopted, newly, an active tuning procedure with piezoelectric actuator to improve a focused image confocality. We have measured point spread function and effective area at 30, 40, 50, and 60 keV. An angular resolution of 1.9 arcmin (HPD) at 30 keV was obtained in the full telescope. The effective area of HXT-1 at 30 keV meets the requirements of HXT.


  • Open Access

    A CANDIDATE ACTIVE GALACTIC NUCLEUS WITH A PURE SOFT THERMAL X-RAY SPECTRUM

    by Yuichi Terashima, Naoya Kamizasa, Hisamitsu Awaki, Aya Kubota, Yoshihiro Ueda


  • Development of ultra-thin thermal shield for ASTRO-H x-ray telescopes

    by Yuzuru Tawara, Satoshi Sugita, Akihiro Furuzawa, Kenji Tachibana, Hisamitsu Awaki, Manabu Ishida, Yoshitomo Maeda, Mina Ogawa

    ASTRO-H is a general purpose X-ray observatory scheduled for launch in 2014. Two soft X-ray telescopes (SXT) and two hard X-ray telescopes (HXT) will be onboard covering energy range of 0.2 -80 keV. Thermal control of the telescope is similar to that of Suzaku, using a thermal shield (TS) placed in front of the telescope and a electric heater attached on the telescope housing. Thus it is required for a TS to have high soft X-ray transmission, low solar absorptance and a low infrared emissivity. To meet these requirement, TS should be made of thin plastic film coated by metal such as aluminum. Then most important property of TS is mechanical strength to survive various environments at the launch and in orbit. This paper describes designing of TS, method of TS production, various environmental conditions and tests, risk management of treatment of ultra-thin film of TS in the process of production, testing and assembling.


  • The current status of reflector production and hard x-ray characterization for ASTRO-H/HXT

    by Takuya Miyazawa, Akihiro Furuzawa, Yasufumi Kanou, Kenji Matsuda, Michito Sakai, Nobuyuki Yamane, Hiroyoshi Kato, Yusuke Miyata, Karin Sakanobe, Yoshito Haba, et al.

    Japan's sixth X-ray satellite mission ASTRO-H is planned to be launched in 2014. Hard X-ray Telescope (HXT) to cover hard X-rays up to 80 keV is thin-foil, multi-nested conical optics with depth-graded Pt/C multilayer. The mass production of the reflectors for the flight model has been going on since August 2010. We have introduced a new screening method for replication mandrels with optical imagers. In addition, we have adopted a new replication mandrel which consists of glass tube coated with thin glass sheet for large size mandrels. The selected 212 pairs (95 pairs (segment 1), 59 pairs (segment 2), 58 pairs (segment 3)) of multilayer mirror have been characterized at a large synchrotron radiation facility, Spring-8 beamline BL20B2. We present the current status of reflector production and hard X-ray characterization for HXT.

  • The current status of the reflector production for ASTRO-H/HXT

    by Akihiro Furuzawa, Takuya Miyazawa, Kanou Yasufumi, Kenji Matsuda, Michito Sakai, Yosuke Ishida, Shinji Hara, Koudai Yamane, Nobuyuki Yamane, Yusuke Miyata, et al.

    Japan's 6th X-ray satellite mission ASTRO-H, which is planed to be launched in the fiscal year 2013, will carry two hard X-ray telescopes (HXT) using depth-graded multilayer reflectors which provide us the capability of hard X-ray imaging observation up to 80 keV. ASTRO-H/HXT is the light-weight hard X-ray telescope using Pt/C depth-graded multilayer and high-throughput thin-foil optics. The basic technology for fabricating ASTROH /HXT has been established through the balloon borne experiments, InFOCμS and SUMIT mission. The HXT consists of about 1300 foil reflectors of which a size of the 200 mm mirror length and the diameter range of 120-450 mm which is much larger that those for the balloon borne experiments. To clear the requirements of the angular resolution and the effective photon collecting area for ASTRO-H/HXT, we should produce twice the total number of reflectors and select them. Therefore we need to produce more than 5000 foil reflectors for the two flight telescopes. The installation of the production line and optical evaluation system dedicated to the ASTRO-H/HXT has been almost done. We are testing and improving the production line through productions of several sizes of reflectors. The mass production of the reflectors for the flight model is scheduled to start from July 2010.


  • Vibration properties of hard x-ray telescope on board satellite

    by Tatsuro Kosaka, Takeyuki Igarashi, Hisamitsu Awaki, Keiji Ogi, Keitaro Itoh, Yoshitomo Maeda, Manabu Ichida, Akihiro Furuzawa, Takuya Miyazawa, Hideyo Kunieda

    ASTRO-H is the new Japanese X-ray astronomy satellite for launch in 2013. HXT on board the satellite has a mirror housing which is a cylindrical case and contains reflection mirror foils, which are constrained by alignment bars. In order to investigate vibration properties of HXT on board the satellite, vibration tests and FEM analyses were conducted. From the results of x-vibration test, it was found that there were no resonant frequencies at frequency less than 120 Hz. It also appeared that foils move along grooves of alignment bars when the housing was vibrated because kinetic connection between foils and alignment bars is only friction force. From the simulated results, this loose connection used in the actual HXT housing is useful to suppress a strong resonance at 51Hz predicted by supposing tight connections such as adhesiveness. As for z-vibration properties, vibration property of the housing was complicated since foils leap when zacceleration becomes larger than 1G. However it could be confirmed that the distinct resonant peaks did not appear at frequency less than 200 Hz. From these results, it was found that HXT housing had not any resonant frequencies less than 120 Hz, which is the maximum frequency of sinusoidal vibrations applied when launched.