TZT. Zehlicke

T. Zehlicke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


T. Zehlicke has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 May 2012
      • Vol. 71  (2) , 109-14

    Matrix change of bone grafting substitute after implantation into guinea pig bulla.

    by Ch Punke, T Zehlicke, T Just, G Holzhüter, T Gerber, H W Pau

    Many different surgical techniques have been developed to remove open mastoid cavities. In addition to autologous materials, alloplastic substances have been used. A very slow absorption of these materials and extrusion reactions have been reported. We investigated a newly developed, highly porous bone grafting material to eliminate open mastoid cavities, in an animal model. To characterise the transformation process, the early tissue reactions were studied in relation to the matrix transformation of the bone material. NanoBone (NB), a highly porous bone grafting material based on calcium phosphate and silica, was filled into the open bullae from 20 guinea pigs. The bullae were examined histologically. Energy dispersive X-ray spectroscopy (EDX) was used to investigate the change in the elemental composition at different sampling times. The surface topography of the sections was examined by electron microscopy. After 1 week, periodic acid-Schiffs (PAS) staining demonstrated accumulation of glycogen and proteins, particularly in the border area of the NB particles. After 2 weeks, the particles were evenly coloured after PAS staining. EDX analysis showed a rapid absorption of the silica in the bone grafting material. NanoBone showed a rapid matrix change after implantation in the bullae of guinea pigs. The absorption of the silica matrix and replacement by PAS-positive substances like glycoproteins and mucopolysaccharides seems to play a decisive role in the degradation processes of NB. This is associated with the good osteoinductive properties of the material.

  • Minimal-invasive, endoskopische Technik der Elektrodendurchführung bei einem Cochlea-Implantat

    by T. Zehlicke, O. Niclaus, W. Wempe, M. Pohl

    Die beidseitige Cochlea-Implantat-Versorgung entwickelt sich zunehmend zum Standard in der Behandlung der beidseitigen hochgradigen Schwerhörigkeit. "Verlockend" ist es, wenn dafür nur noch eine einzige Operation erforderlich ist. Ohne an dieser Stelle die Vor- und Nachteile der Implantation von 2 versus 1 Cochlea-Implantat mit 2 Elektroden aufzunehmen, stellen Zehlicke et al. ihre "Tipps und Tricks" zur minimal-invasiven Implantation der letztgenannten Kombinationsgeräte dar. Ihre Technik lehnt sich stark an das endoskopische Augenbrauen-Lifting und die alte Diaphanoskopie an und wird um einige "pfiffige" Ideen zum Durchzug der Elektroden ergänzt. Prof. Dr. Dr. R. Siegert, Recklinghausen

  • Ein neuartiger, hochflexibler Tubenendoskopaufsatz aus Silikon für eine ambulante Mittelohrdiagnostik unter lokaler Betäubung

    by K Kaiser, T Zehlicke, J Müller

    Für die Mittelohrdiagnostik und die Beobachtung der Tube steht bislang kein geeignetes nicht invasives Verfahren zur Verfügung. Der hier vorgestellte Endoskopaufsatz kann optisch verlustarm auf vorhandene starre oder flexible Endoskope aufgesetzt werden. Er besteht vollständig aus Silikon und ist dadurch sehr weich und hochflexibel und kann, im Gegensatz zu den flexiblen, aber vergleichsweise harten Glasfaserendoskopen, ohne Gefahr von Verletzungen und unter lokaler Betäubung über die Nase in die Eustachische Röhre und das Mittelohr eingeführt werden. Damit wird erstmals eine ambulante Mittelohrdiagnostik möglich. Der hochflexible Aufsatz ist als Einwegartikel konzipiert und kann nach der Untersuchung einfach entsorgt werden. Der Endoskopaufsatz ist analog den handelsüblichen Glasfaserendoskopen aufgebaut. Zur Beleuchtung befindet sich außen ein Illuminationsring aus einer Silikonschicht mit einem hohen Brechungsindex (6), umgeben von zwei Schichten mit niedrigen Brechungsindizes (5 und 7). Das Licht wird gemäß dem Prinzip der Totalreflexion in der Schicht mit dem höheren Brechungsindex geführt. Ein Linsensystem (2) fokussiert das vom Objekt reflektierte Licht auf ein Wellenleiterbündel (1), welches das Bild zum Detektor bzw. Okular führt. Das Illuminationssignal wird durch eine lichtundurchlässige Schicht (4) vom Bildsignal isoliert. Das Linsensystem liegt vergraben in der niederbrechenden Schicht (3), damit nur das reflektierte Licht und nicht das beleuchtende detektiert wird. Pro Pixel werden 9µm2 benötigt. Damit liegt die Auflösung eines Tubenendoskops mit einem Durchmesser von insgesamt 0,5mm bei 16.000 Pixeln. Für größere Durchmesser lassen sich entsprechend höhere Auflösungen realisieren. Der Prototyp eines solchen Endoskopaufsatzes befindet sich augenblicklich im Aufbau. Erste Transmissionsmessungen an den Fasern zeigen eine sehr hohe Transparenz, vergleichbar zu der von Glasfasern auf der benötigten kurzen Weglänge.

  • Tensometrie - Entwicklung eines Langzeitmessverfahrens der Tubenfunktion am Felsenbeinpräparat

    by T. Zehlicke, T. Just, O. Specht, W. Schmidt, W. Sass, C. Moss, H.-W. Pau

    Hintergrund: Die Mittelohrfunktion ist weitestgehend von der Tubenfunktion abhängig. Nahezu alle pathologischen Mittelohrbefunde gehen mit einer Tubendysfunktion einher. Bis heute gibt es kein Untersuchungsverfahren (z. B. die Tympanometrie oder Tubenmanometrie), welches die Tubenfunktion unter physiologischen Bedingungen als Langzeitmessung ableiten kann. Ziel der vorliegenden Arbeit war es zu testen, ob sich Druckänderungen im Mittelohr mit neu entworfenen Folien mit integrierten DMS erfassen lassen. Material und Methoden: Dazu wurden experimentell Druckänderungen im Mittelohr erzeugt, die Stabilität der Folienanhaftung während der Druckänderungen unter Verwendung der Videoendoskopie geprüft, und diese Ergebnisse mit den Messergebnissen der Messfolie korreliert. Bei diesen Untersuchungen kamen DMS aus Platin und Gold auf PET-Folie am Felsenbeinmodell zum Einsatz. Ergebnisse: Es konnte gezeigt werden, dass die DMS-Messspannung in Vollbrückenschaltung abhängig von der Positionierung auf dem Trommelfell phasengleich aber auch gegenphasig zur Mittelohrdruckkurve verlaufen kann. Bei der Viertelbrückenschaltung war diese Ausrichtungsabhängigkeit geringer. Messungen bei kleinen Trommelfellperforationen waren möglich. Schlussfolgerungen: Zur Verbesserung der Zuverlässigkeit der DMS bei mechanischer Beanspruchung und zur Gewährleistung der Langzeitstabilität wird ein neues Design auf der Basis von Konstantan (Cu-Ni-Mn) vorgeschlagen, mit dem Langzeitmessungen der Tubenfunktion an Patienten realisierbar werden. Tensometry – Development of a Measurement Technique of the Tube Function in a Temporal Bone Model Objective: Middle ear pressure depends widely on the function of the eustachian tube. Tube dysfunction is often a trigger for middle ear diseases like chronic otitis media but also for barotrauma. Patients with impaired tubal function should not be exposed to situations with extreme pressure changes. Until today, there is no valid examining method for long-time measuring of the development of middle ear pressure. Material and Methods: The basic idea was to develop a thin flexible film with integrated strain gauges made of platinum and gold, which can be applied directly on the surface of the tympanic membrane. Using these, shifts or distensions of the tympanic membrane in a temporal bone model can be measured and documented. Results: We were able to show that the measuring system was sensitive enough to register pressure variations in the middle ear volume of a temporal bone model. While using a full bridge design of the strain gauge resistors it could be shown that the measuring voltage of the strain gauges were in phase of the pressure measurement curve or according to the positioning in opposite phase. In single resistor mode the measurement were not so positioning depended. Measuring tympanic membrane movement in case of perforation was feasible. Conclusions: To improve the longtime stability of the strain gauge film the next development step will be to make a new design with Konstantan resistors (CU-Ni-Mn). After a testing period, longtime measurements in clinical studies will follow.


  • Untersuchung von hochporösem Knochenaufbaumaterial zur Mastoidhöhlenobliteration- Intrabulläre Applikation beim Meerschweinchen

    by C. Punke, T. Zehlicke, C. Boltze, H. W. Pau

    Einleitung: Eine Vielzahl an unterschiedlichen Techniken wurde für die Mastoidhöhlenobliteration entwickelt. Neben autologen Materialien kamen alloplastische Substanzen wie Hydroxylapatit- bzw. Trikalziumphosphatkeramik kamen bisher zum Einsatz. Eine nur sehr langsame Resorption dieser Materialien in Verbindung mit Abstoßungsreaktionen wurde beschrieben. Wir haben neu entwickelte hochporöse Knochenaufbaumaterialien hinsichtlich ihrer Verwendbarkeit zur Mastoidhöhlenobliteration in einem Tiermodell (Meerschweinchenbulla) untersucht. Material und Methode: Mit einem im Sol-Gel-Verfahren hergestellten hochporösen Knochenaufbaumaterial (NanoBone®) wurde die geöffnete Bulla von 30 Meerschweinchen befüllt. Auf der Gegenseite wurde ein Knochenaufbaumaterial aus dem mineralischen Anteil bovinen Knochens (Bio-Oss®) für die Obliteration verwandt. Die Bullae wurden nach 1, 2, 3, 4, 5 und 12 Wochen entnommen und histologisch untersucht. Ergebnisse: Nach einer initialen Entzündungsreaktion und Bildung eines Granulationsgewebes kam es in beiden Gruppen zu Ausbildung trabekulären Knochens ab der 4. Woche. Ab der 5. Woche ließen sich auf den Oberflächen von NanoBone® und Bio-Oss® Osteoklasten, welche die Materialien abbauten, nachweisen. Schlussfolgerung: Im Einsatz beim Meerschweinchen zeigten neu entwickelte Knochenersatzmaterialien günstige Eigenschaften bei der Teilobliteration von Mittelohrräumen (Bullae) als Modell für das menschliche Mastoid. Investigation of a New Highly Porous Hydroxyapatite Matrix for Obliterating Open Mastoid Cavities – Application in Guinea Pigs Bulla Background: Many different techniques for obliterating open mastoid cavity have been described. The results after the application of alloplastic materials like Hydroxyapatite and Tricalciumphosphate were poor due to long-lasting resorption. Extrusion of those materials has been described. We investigated the applicability of a new high-porosity ceramic for obliterating large open mastoid cavities and tested it in an animal model (bulla of guinea pig). Methods: A highly porous matrix (NanoBone®) bone-inductor fabricated in a sol-gel-technique was administered unilaterally into the opened bullae of 30 guinea pigs. In each animal the opposite bulla was filled with Bio-Oss®, a bone substitute consisting of a portion of mineral bovine bone. Histological evaluations were performed 1, 2, 3, 4, 5 and 12 weeks after the implantation. Results: After the initial phase with an inflammatory reaction creating a loose granulation tissue, we observed the formation of trabeculare bone within the fourth week in both groups. From the fifth week on we found osteoclasts on the surface of NanoBone® and Bio-Oss® with consecutive degradation of both materials. Conclusion: In our animal model study we found beneficial properties of the used bone-inductors NanoBone® and Bio-Oss® for obliterating open mastoid cavities.


  • Letale Blutung aus dem Truncus brachiocephalicus - Spätkomplikation nach Fehleinschätzung eines Dilatationstracheostomas bei rudimentärer Halsrippe

    by T. Zehlicke, S. Dommerich, J. Rummel, H. W. Pau

    Hintergrund: Seit Jahren steigt die Anzahl der meist vom Intensivmediziner durchgeführten Dilatationstracheotomien überproportional, u. a. auch für die Langzeitkanülierung. Da im weiteren Verlauf der Rehabilitationsmaßnahmen der Kanülenwechsel durchaus in den Händen von Personal liegen kann, das mit der veränderten Anatomie der Atemwege wenig vertraut ist, muss das Tracheostoma so übersichtlich und sicher wie möglich sein, um die Möglichkeit schwerwiegender Komplikationen zu verringern. Fallbericht: Es wird über eine letale Blutung aus dem Truncus brachiocephalicus als Spätkomplikation nach einer Dilatationstracheotomie berichtet, verursacht durch eine Kanülenfehllage. Im vorliegenden Fall wird zusätzlich eine Begünstigung des Ereignisses durch eine Halsrippe diskutiert. Diskussion: Wir plädieren eindringlich dafür, in Fällen absehbarer Langzeitkanülierung von vornherein ein „epithelisiertes Tracheostoma” anzulegen oder ein unübersichtliches Dilatationstracheostoma entsprechend operativ umzugestalten. Bei Zweifeln an der korrekten Kanülenlage muss eine endoskopische Kontrolle erfolgen. Background: In the last years percutaneous dilatative tracheostomy was increasingly established in many intensive care units, mostly performed by the anesthesiologists. This method becomes problematic, when it is used in patients requiring long time intubation. It must always be kept in mind that in the course of further rehabilitation the patients may be treated by persons, who are not familiar with the altered anatomy of the upper airways. This bears the risk for severy complications, like bleeding from major vessels. Case report: Letal arrosion bleeding of the brachiocephalic trunc was observed in a patient, 3 weeks after percutaneous dilatative tracheostomy (technique by Griggs). As an abnormality the patient had a cervical rib. The wrong position of the tracheostomy tube was not noticed because the patient had no dyspnoea, spontaneously breathing through the nose and mouth instead of through the tracheostomy tube. Conclusions: Particularly in patients requiring long-time intubation it is essential that the tube can be changed safely. We advocate an „epithelialized” tracheostoma with tracheocutaneous anastomosis for these patients. If the position of the tracheostomy tube is not clear, endoscopic control has to be performed.


  • Das Myxom des Mittelohrs als mögliche Ursache einer temporären Fazialisparese

    by T. Zehlicke, C. Punke, K. Haase, C. Boltze, H. W. Pau

    Das Auftreten einer Fazialisparese bei entzündungsähnlicher Symptomatik lässt in erster Linie an virale (Zoster) oder bakterielle Affektionen denken. Es wird hier über einen Patienten berichtet, bei dem die operative Exploration des Mittelohrs ein neoplastisches Geschehen aufdeckte: ein Myxom. Dieser Tumor ist sehr selten im Kopf-Hals-Bereich. Die ansonsten typische Tumorlokalisation ist das Herz, zumeist der linke Herzvorhof. Im HNO-Bereich wachsen diese Neoplasien in der Regel langsam und bleiben symptomlos, bis sie wichtige Strukturen verdrängen oder infiltrieren und somit in ihrer Funktion beeinflussen, z. B. den N. facialis oder den lateralen Bogengang. Histologisch weisen Myxome ein myxoid aufgelockertes Gewebe auf, das reich an Mukopolysacchariden ist. Schwierigkeiten liegen in der Differenzialdiagnose u. a. zu chronischen, langandauernden Entzündungsprozessen. Therapie der Wahl ist die chirurgische Resektion des Tumors. Im vorliegenden Fall wird trotz des operationsmikroskopisch als knöchern unversehrt beurteilten Fazialiskanals ein kausaler Zusammenhang zwischen Fazialisparese und Myxom diskutiert, wenngleich eine koinzidente idiopathische Fazialisparese nicht absolut ausgeschlossen werden kann. In case of the co-occurrence of facial palsy and inflammation-like symptoms of the same ear, the differential diagnosis is focused on viral (herpes zoster) or bacterial diseases. We report a patient for whom the surgical exploration of the middle ear revealed a benign tumor: a myxoma. These neoplasias are rare tumors in the head and neck region. The typical tumor site is the atrium of heart. In the ear, the tumor grows slowly and remains asymptomatic unless it irritates structures such as the facial nerve or the vestibular organ. Histologically, the tumor presents a “myxoid” matrix that is rich in acid mucopolysaccarides. The treatment of choice is complete surgical resection. Using the case presented, we discuss the causality between the tumor and the facial palsy, although during the operation the bony canal of the nerve was found to be intact. In any cases with clinically and radiologically unclear findings of the ear in connection with facial palsy, surgical exposure should be considered.