Alwin F.J. Brouwer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Alwin F.J. Brouwer has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
P. L. P. Brand
2 shared publicationsR. J. Roorda
2 shared publications- Arvid. W. A. Kamps
Department of Paediatrics Martini Hospital Groningen The Netherlands
1 shared publication D. A. van Reijn
1 shared publicationI. M. M. Reinaerts
1 shared publicationP L P Brand
1 shared publication
Latest Publications
- 17 May 2008
- Vol. 152 (20) , 1151-5
[Treatment of asthma in children: revised international guidelines not suitable for use in the Netherlands].
The most recent revision of the Global Initiative for Asthma (GINA) guidelines for the treatment of asthma propose to classify and monitor the disease based on asthma control. This concept is attractive but not evidence based. Based on methodological shortcomings the revised GINA guidelines fail to meet the standards for evidence-based guidelines. Inhaled corticosteroids are and remain the cornerstone of asthma management in children. Extensive explanation to children and their parents, intensive followup, and instruction of and adherence to a correct inhalation technique are key factors in effective treatment of asthma in children.
- 17 May 2008
- Vol. 152 (20) , 1151-5
[Treatment of asthma in children: revised international guidelines not suitable for use in the Netherlands].
The most recent revision of the Global Initiative for Asthma (GINA) guidelines for the treatment of asthma propose to classify and monitor the disease based on asthma control. This concept is attractive but not evidence based. Based on methodological shortcomings the revised GINA guidelines fail to meet the standards for evidence-based guidelines. Inhaled corticosteroids are and remain the cornerstone of asthma management in children. Extensive explanation to children and their parents, intensive followup, and instruction of and adherence to a correct inhalation technique are key factors in effective treatment of asthma in children.
- 18 July 2007
- Published by Wiley in Pediatric Pulmonology
- Vol. 42 (9) , 813-818
Comparison between peak expiratory flow and FEV1 measurements on a home spirometer and on a pneumotachograph in children with asthma
Background: The accuracy of electronic portable home spirometers has been demonstrated in vitro using computer‐based waveforms. We assessed the agreement in vivo between measurements of lung function on an electronic spirometer (Koko Peak Pro) and those obtained by the gold standard, a hospital lung function laboratory pneumotachograph.Methods: Fifty stable asthmatic children (33 boys), aged 6–17 years, performed peak expiratory flow (PEF) and forced expiratory volume in 1 sec (FEV1) measurements according to international guidelines on a portable home spirometer and on the hospital pneumotachograph in random order. All measurements complied to standard quality criteria. The PEF and FEV1 values recorded with the home spirometer and on the hospital pneumotachograph were compared.Results: All children performed reproducible high‐quality measurements on both spirometers. PEF values on the home spirometer were considerably lower than on the laboratory pneumotachograph (95% CI for difference in PEF 14–30 L/min; P < 0.0001). Individual differences in PEF between the two devices could be >100 L/min. The FEV1 values were slightly, but significantly, lower on the home spirometer (95% CI for difference in FEV1 0.02–0.1 L; P = 0.0018).Conclusions: A home spirometer provides reproducible and quality acceptable measures in children with asthma when performed under professional supervision and encouragement. Mean PEF and FEV1 values recorded on this home spirometer are significantly lower than those on a hospital pneumotachograph, and individual differences may be large. Therefore, home spirometry may not be interchanged with pneumotachography in a lung function laboratory. Pediatr Pulmonol. 2007; 42:813–818.
- 18 July 2007
- Published by Wiley in Pediatric Pulmonology
- Vol. 42 (9) , 813-818
Comparison between peak expiratory flow and FEV1 measurements on a home spirometer and on a pneumotachograph in children with asthma
Background: The accuracy of electronic portable home spirometers has been demonstrated in vitro using computer‐based waveforms. We assessed the agreement in vivo between measurements of lung function on an electronic spirometer (Koko Peak Pro) and those obtained by the gold standard, a hospital lung function laboratory pneumotachograph.Methods: Fifty stable asthmatic children (33 boys), aged 6–17 years, performed peak expiratory flow (PEF) and forced expiratory volume in 1 sec (FEV1) measurements according to international guidelines on a portable home spirometer and on the hospital pneumotachograph in random order. All measurements complied to standard quality criteria. The PEF and FEV1 values recorded with the home spirometer and on the hospital pneumotachograph were compared.Results: All children performed reproducible high‐quality measurements on both spirometers. PEF values on the home spirometer were considerably lower than on the laboratory pneumotachograph (95% CI for difference in PEF 14–30 L/min; P < 0.0001). Individual differences in PEF between the two devices could be >100 L/min. The FEV1 values were slightly, but significantly, lower on the home spirometer (95% CI for difference in FEV1 0.02–0.1 L; P = 0.0018).Conclusions: A home spirometer provides reproducible and quality acceptable measures in children with asthma when performed under professional supervision and encouragement. Mean PEF and FEV1 values recorded on this home spirometer are significantly lower than those on a hospital pneumotachograph, and individual differences may be large. Therefore, home spirometry may not be interchanged with pneumotachography in a lung function laboratory. Pediatr Pulmonol. 2007; 42:813–818.
- Open Access
- 26 July 2006
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 28 (6) , 1131-1137
Home spirometry and asthma severity in children
The usefulness of peak expiratory flow monitoring is disputed because of the unreliability of written peak flow diaries. The aim of the present study was to examine the relationship of peak flow and forced expiratory volume in one second (FEV1) variation to other estimates of asthma severity in children, using an electronic home spirometer with automatic data storage.Over a 3-month period, 36 children with mild-to-moderate persistent asthma recorded peak flow and FEV1electronically twice daily and noted an asthma severity score in a written diary. Bronchial responsiveness was assessed at the beginning and bronchodilator response and asthma-specific quality of life at the end of the study.Variations in peak flow correlated significantly but weakly to bronchial responsiveness and bronchodilator response, but not to the asthma severity score or quality-of-life scores. Within-individual correlations between asthma severity scores and home spirometry indices and between peak flow and FEV1were highly variable.In conclusion, variations in peak flow and forced expiratory volume in one second, obtained by home spirometry, show poor concordance with other indices of disease activity and with each other. This limits the usefulness of home spirometry in childhood asthma.
- 26 July 2006
- Published by European Respiratory Society (ERS) in European Respiratory Journal
- Vol. 28 (6) , 1131-1137
Open AccessHome spirometry and asthma severity in children
The usefulness of peak expiratory flow monitoring is disputed because of the unreliability of written peak flow diaries. The aim of the present study was to examine the relationship of peak flow and forced expiratory volume in one second (FEV1) variation to other estimates of asthma severity in children, using an electronic home spirometer with automatic data storage.Over a 3-month period, 36 children with mild-to-moderate persistent asthma recorded peak flow and FEV1electronically twice daily and noted an asthma severity score in a written diary. Bronchial responsiveness was assessed at the beginning and bronchodilator response and asthma-specific quality of life at the end of the study.Variations in peak flow correlated significantly but weakly to bronchial responsiveness and bronchodilator response, but not to the asthma severity score or quality-of-life scores. Within-individual correlations between asthma severity scores and home spirometry indices and between peak flow and FEV1were highly variable.In conclusion, variations in peak flow and forced expiratory volume in one second, obtained by home spirometry, show poor concordance with other indices of disease activity and with each other. This limits the usefulness of home spirometry in childhood asthma.
- 1 December 2004
- Published by Springer Nature in Tijdschrift voor kindergeneeskunde
- Vol. 72 (6) , 234-237
Inspanningsgebonden benauwdheid bij kinderen: disfunctionele ademhaling?
- 1 December 2004
- Published by Springer Nature in Tijdschrift voor kindergeneeskunde
- Vol. 72 (6) , 234-237
Inspanningsgebonden benauwdheid bij kinderen: disfunctionele ademhaling?