HHHisanao Hazama

Hisanao Hazama

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hisanao Hazama has a total of 176 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Review of: "Conservative Retreatment of Ten Failing Ceramic Veneers Using Er:YAG Laser-Assisted Debonding, Diagnostic Mock-up, Gingival Recontouring, and Adhesive Cementation: A Case Report"

    by Hisanao Hazama

    Although this paper is acceptable as a case report of a specific patient, the laser irradiation conditions are insufficiently described, which limits the scientific generalizability of the findings.

  • Open Access

    Hydroxyaldehyde and formyl photoproducts of protoporphyrin IX formed under photodynamic diagnosis and therapy irradiation conditions

    by Sochi J. Ogbonna, Katsuyoshi Masuda, Hisanao Hazama

    Photoproducts of the photosensitizer protoporphyrin IX (PpIX) may have diagnostic and therapeutic relevance in photodynamic diagnosis (PDD) and photodynamic therapy (PDT), as they possess fluorescence and photosensitizing properties and could serve as a complementary dosimetry index alongside photosensitizer photobleaching. Consequently, a detailed characterization of these photoproducts is necessary for exploring their potential application in PDD and PDT. Further, understanding the processes of photobleaching and photoproduct formation will be useful for diagnosis and treatment planning in PDD and PDT. In this study, the formation of four photoproducts previously observed from the irradiation of PpIX‐dimethyl ester was extended to investigate their formation from PpIX. PpIX in solution was irradiated at 405 and 635 nm, wavelengths relevant to PDD and PDT, and the formation of the photoproducts was analyzed using liquid chromatography–tandem mass spectrometry (LC–MS/MS). Hydroxyaldehyde and formyl photoproducts, and their isomeric forms, were identified, and their fold increases were evaluated under different irradiation conditions. Although the physicochemical properties of photoproducts depend on the environment, this solution‐based study provides fundamental understanding of the photochemical reaction of PpIX and its photoproducts under clinically relevant irradiation conditions and may aid studies aimed at exploiting photoproducts for improved dosimetry and therapeutic outcomes in PDD and PDT.

  • Open Access

    Atmospheric Pressure Mass Spectrometry Imaging Using Electrospray-Assisted Laser Desorption/Ionization with Gas Transportation through a Heated Tube and Minimal Sample Preparation

    by Riku Hirotani, Yuto Miyoshi, Varun Sendilraj, Hisanao Hazama

    Mass spectrometry (MS) is a valuable tool that enables label-free analysis and the ability to measure multiple molecules. The atmospheric pressure MS imaging (MSI) method usually requires tedious sample preparation. A simple ionization method with minimal sample preparation is needed for high-throughput analysis. We have developed an ion source that does not require sample preparation such as thinning, curing, planarization, or addition of matrix by the electrospray-assisted laser desorption/ionization with gas transportation (ELDI-GT). The sample is transported with nitrogen gas through a heated tube to the electrospray. The ion signal of protonated caffeine was measured under different transport conditions. The ion signal intensity was found to increase 11-fold by changing the flow rate and tube temperature from 2.8 cm3/s and 473 K to 25 cm3/s and 673 K. ELDI-GT was able to visualize the localization of caffeine crystals at a pixel size of 50 µm using MSI because of the effective GT using the heated tube. The dependence of the ion signal intensity was discussed on the amount of heat applied to the sample in the heated tube. ELDI-GT allowed accurate localization of caffeine at a pixel size of 50 µm without the need to apply thinning and matrix to a sample.


  • Open Access

    The effect of fluence rate and wavelength on the formation of protoporphyrin IX photoproducts

    by Sochi J. Ogbonna, Katsuyoshi Masuda, Hisanao Hazama

    Photodynamic diagnosis and therapy (PDD and PDT) are emerging techniques for diagnosing and treating tumors and malignant diseases. Photoproducts of protoporphyrin IX (PpIX) used in PDD and PDT may be used in the diagnosis and treatment, making a detailed analysis of the photoproduct formation under various treatment and diagnosis conditions important.Spectroscopic and mass spectrometric analysis of photoproduct formation from PpIX dissolved in dimethyl sulfoxide were performed under commonly used irradiation conditions for PDD and PDT, i.e., wavelengths of 405 and 635 nm and fluence rates of 10 and 100 mW/cm2. Irradiation resulted in the formation of hydroxyaldehyde photoproduct (photoprotoporphyrin; Ppp) and formyl photoproduct (product II; Pp II) existing in different quantities with the irradiation wavelength and fluence rate. Ppp was dominant under 635 nm irradiation of PpIX, with a fluorescence peak at 673 nm and a protonated monoisotopic peak at m/z 595.3. PpIX irradiation with 405 nm yielded more Pp II, with a fluorescence peak at 654 nm. A higher photoproduct formation was observed at a low fluence rate for irradiation with 635 nm, while irradiation with 405 nm indicated a higher photoproduct formation at a higher fluence rate.The photoproduct formation with the irradiation conditions can be exploited for dosimetry estimation and may be used as an additional photosensitizer to improve the diagnostics and treatment efficacies of PDD and PDT. Differences in environmental conditions of the present study from that of a biological environment may result in a variation in the photoproduct formation rate and may limit their clinical utilization in PDD and PDT. Thus, further investigation of photoproduct formation rates in more complex biological environments, including in vivo, is necessary. However, the results obtained in this study will serve as a basis for understanding reaction processes in such biological environments. Graphical abstract


  • Open Access

    Mechanism of dentin hardness measurements using a dentin hardness measuring device with a light-emitting diode

    by Sota Kondo, Yutaka Tomioka, Naohiro Fujimoto, Atsushi Mine, Satoshi Yamaguchi, Saeko Okumura, Hiroaki Tanimoto, Kenzo Yasuo, Kazushi Yoshikawa, Kazuyo Yamamoto, et al.

    The world’s population is not only increasing but it is also aging. According to the World Health Organization (WHO), one in six people will be 60 years or older by 2030, and the world’s population over 60 years of age will reach 2.1 billion by 2050.1 As life expectancy of the aging population increases, people retain their teeth for longer,2 increasing the risk of developing caries. Especially, root caries is a dental disease affecting more than one-third of the geriatric population.3

  • Analyses of protoporphyrin IX fluorescence photoswitching for prolonging the photodynamic diagnosis time of deeply located tumours

    by Sochi J. Ogbonna, William Y. York, Takahiro Nishimura, Hisanao Hazama, Kunio Awazu

    The diagnostics depth of tumour during photodynamic diagnosis (PDD) is dependent on the wavelength of the excitation light, as there is the attenuation of light by absorption and scattering. The use of 505 nm excitation to extend the diagnostics depth of deeply located tumour has been reported. However, the fluorescence emission intensity during fluorescence observation of the tumour is affected by the photobleaching of the photosensitizer. The photosensitizer photobleaching is accompanied by the formation of its photoproduct. This study has investigated the potential use of fluorescence emission from protoporphyrin IX (PpIX), followed by the combined use of the fluorescence emission from PpIX and its photoproduct, for the fluorescence observation of deeply located tumours. We have introduced the concept of fluorescence photoswitching, where the excitation of the photoproduct formed during the initial PDD, can lead to fluorescence intensity higher than that obtained by PpIX excitation. An increase in the fluorescence detection intensity and time for tumour detection may be achieved with fluorescence photoswitching. Preliminary experiments on fluorescence photoswitching were performed for PpIX in solution and ex vivo. Fluorescence photoswitching was observed in both forms of PpIX investigated, with a maximum of 94 % initial PpIX intensity obtained with the excitation of the photoproduct. It is expected that a higher fluorescence emission can be attained with the optimisation of the irradiation conditions. Although further investigations are required, this work has demonstrated the potential of fluorescence photoswitching for extending the fluorescence observation time for the PDD of deeply located tumours.

  • Open Access

    Increased fluorescence observation intensity during the photodynamic diagnosis of deeply located tumors by fluorescence photoswitching of protoporphyrin IX

    by Sochi J. Ogbonna, William Y. York, Takahiro Nishimura, Hisanao Hazama, Hideo Fukuhara, Keiji Inoue, Kunio Awazu

    Photodynamic diagnosis (PDD) using 5-aminolevulinic acid-induced protoporphyrin IX (ALA-induced PpIX) for the visualization and detection of various cancers is widespread.1 – 4 PpIX, used as the photosensitizer in this technique, is a natural intermediate in the heme synthesis pathway and is generated from its precursor ALA. PpIX is characterized by its selective accumulation in cancer cells, and it is fluorescent when excited at an appropriate wavelength, leading to cancer cell detection.5 – 7 Although this diagnostic technique is minimally invasive and offers high specificity for cancer cell detection,1,2,8 the diagnostic efficacy of PDD is affected by some factors, including the wavelength of the excitation light and the photobleaching of PpIX.


  • Open Access

    Demonstration of an optical dentin hardness measuring device using bovine dentin with different demineralization times

    by Sota Kondo, Hisanao Hazama, Yutaka Tomioka, Atsushi Mine, Satoshi Yamaguchi, Saeko Okumura, Hiroaki Tanimoto, Kenzo Yasuo, Kazushi Yoshikawa, Kazuyo Yamamoto, et al.

    SignificanceThe increase in root caries is a serious problem as society ages. Root caries is diagnosed by inspection and palpation, which are qualitative. A method to objectively and quantitatively evaluate the progress of root caries in a clinical setting is strongly desired. The root caries could be diagnosed by measuring hardness because dentin becomes softer as the caries progresses. Vickers hardness has been customarily used as an indicator of tooth hardness. However, this method cannot be used to in vivo teeth because the teeth must be dried prior to measurement to make the indentation. A hardness meter using an indenter with light for tooth monitoring (HAMILTOM) is proposed as an optical device. HAMILTOM could measure hardness of teeth in wet condition as a dark area while applying a load to dentins without drying. Therefore, HAMILTOM may realize hardness measurements of in vivo teeth in a clinical setting quantitatively.AimThe aim of our study is to demonstrate the optical dentin hardness measuring device HAMILTOM using bovine dentin with different demineralization times and to evaluate the correlation between the dark areas measured by HAMILTOM and the Vickers hardness measured by the Vickers hardness tester.ApproachThe samples were 20 bovine dentins. They were demineralized by a lactic acid solution with different times and divided into groups 1 and 2 of 10 samples each. In both groups, the dark areas and Vickers hardness were measured for each sample. Group 1 was used to obtain a calibration curve to calculate Vickers hardness from the dark area. Group 2 was used to validate the calibration curve obtained from the dentin samples of group 1.ResultsThe areas appearing black without a total internal reflection of the indenter measured by HAMILTOM increased as the demineralization time increased. Additionally, the Vickers hardness of group 2 calculated by the dark areas of group 2 and the calibration curve obtained in group 1 and the Vickers hardness of group 2 measured by the Vickers hardness tester were strongly correlated with a determination coefficient of 0.99.ConclusionsThe results demonstrate that HAMILTOM may be a suitable alternative to the conventional method. Unlike the conventional method, which cannot be used for in vivo teeth, HAMILTOM holds potential to quantitatively evaluate the progress of caries in in vivo teeth.


  • Open Access

    Improvement in Ionization Efficiency Using Metal Oxide Nanoparticles in Laser Desorption/Ionization Mass Spectrometry of a Cancer Drug

    by Hiroki Kannen, Yuto Miyoshi, Hisanao Hazama, Kunio Awazu

    Mass spectrometry imaging (MSI) without labeling has the potential for faster screening in drug development. Matrix-assisted laser desorption/ionization (MALDI) is typically used, but it has a large matrix size and uneven drug distribution. Surface-assisted laser desorption/ionization (SALDI) using nanoparticles (NPs) may overcome these issues. Here, the influence of NPs, solvent ratio, and order of dropping of NPs on SALDI-MSI of protoporphyrin IX (PpIX), a cancer drug, are reported. A solution of PpIX in a 50% aqueous solution of 50% acetonitrile at a concentration of 10 μM was used. The NPs include ZnO, Fe3O4, and four types of TiO2. The NPs were fabricated by dissolving them on an aqueous 90% acetonitrile solution. Mass spectra were obtained with a time-of-flight mass spectrometer using a Nd:YAG laser at a 355-nm wavelength. The signal intensity using TiO2 at a 0.5 mg/mL concentration in 50% acetonitrile was increased by 1.6-fold compared to that without TiO2. Changing the solvent to 90% acetonitrile gave a uniform TiO2 distribution and a 9-fold increase in the signal intensity for PpIX. Among the four types of TiO2 with different particle sizes and crystal structures, TiO2 with a smaller particle size and a rutile crystal structure produced the highest signal intensity. Forming a layer on top of the PpIX also resulted in an increased signal intensity. Hence, SALDI using TiO2 provides effective ionization of the drug. In the future, we plan to investigate a spray method for the ionization of PpIX using TiO2 for the MSI of various drugs.


  • Development of fluorescence cystoscope system for extension of diagnosis depth in 5-aminolevulinic acid mediated photodynamic diagnosis of bladder cancer

    by Hiroki Takishima, Takahiro Nishimura, Hisanao Hazama, Hideo Fukuhara, Keiji Inoue, Kunio Awazu

    This study demonstrates a method to extend diagnostic depth in 5-aminolevulinic acid-based photodynamic diagnosis for bladder cancer by a prototype cystoscope system with green light source to excite a photosensitizer in a deep tissue.