Takatoshi Shindo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Takatoshi Shindo has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Megumu Miki
Central Research Institute of Electric Power Industry
10 shared publicationsToru Miki
Central Research Institute of Electric Power Industry, 2‐6‐1, Nagasaka Yokosuka‐shi Kanagawa‐ken 240‐0196 Japan
8 shared publicationsAkira Asakawa
Electric Power Engineering Research Laboratory, Central Research Institute of Electric Power Industry, Japan
7 shared publicationsKenshi Ikesue
Research Labs., Kyushu Electric Power Co., Inc
4 shared publicationsMaki Sakae
Research Labs., Kyushu Electric Power Co., Inc
4 shared publicationsMikihisa Saito
Central Research Institute of Electric Power Industry, 2‐6‐1, Nagasaka Yokosuka‐shi Kanagawa‐ken 240‐0196 Japan
4 shared publications
Latest Publications
- 1 June 2020
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 15 (6) , 976-977
Lightning occurrence characteristics around tokyo skytree
- 1 June 2020
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 15 (6) , 976-977
Lightning occurrence characteristics around tokyo skytree
- 1 October 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 138 (10) , 837-842
Effects of the External Series Impedance on Concurrent Flashover Probability in a Parallel Gap Configuration
Accurate evaluation of flashover occurrence at arcing horns is necessary for the analysis of multiple back-flashover phenomena of transmission lines. In this paper, analyzed results of flashover phenomena in parallel gap configuration with residual voltage after flashover at one of the gaps are compared with experiments. The agreement between the theory and experiments is fairly well, which proves the validity of the analysis.
- 1 October 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 138 (10) , 837-842
Effects of the External Series Impedance on Concurrent Flashover Probability in a Parallel Gap Configuration
Accurate evaluation of flashover occurrence at arcing horns is necessary for the analysis of multiple back-flashover phenomena of transmission lines. In this paper, analyzed results of flashover phenomena in parallel gap configuration with residual voltage after flashover at one of the gaps are compared with experiments. The agreement between the theory and experiments is fairly well, which proves the validity of the analysis.
- 1 August 2018
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 13 (8) , 1106-1109
Concurrent flashover phenomena of a parallel gap configurationeffects of gap length and residual voltage
- 1 August 2018
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 13 (8) , 1106-1109
Concurrent flashover phenomena of a parallel gap configurationeffects of gap length and residual voltage
- 1 May 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 138 (5) , 374-381
Current Observation Results of Upward Negative Flashes Initiated from Tokyo Skytree during 2012 to 2016
Lightning observation has been carried out at Tokyo Skytree, which is a 634-m high freestanding broadcasting tower located in a flat terrain at 1m ASL. 25 downward and 37 upward flashes were observed at the tower during 2012 to 2016. This paper focuses on upward negative flashes initiated from the top of the tower. Of the 37 confirmed upward flashes, 35 current waveforms were recorded by Rogowski coils installed at 497-m height of the tower. One out of 35 upward flashes was a positive flash initiated by a negative upward leader, 7 out of 35 flashes were bipolar flashes initiated by positive upward leaders, and the rest were negative flashes initiated by positive upward leaders. The authors evaluated the lightning current parameters of subsequent strokes and initial continuous currents (ICC) of the upward negative flashes.
- 1 May 2018
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 138 (5) , 374-381
Current Observation Results of Upward Negative Flashes Initiated from Tokyo Skytree during 2012 to 2016
Lightning observation has been carried out at Tokyo Skytree, which is a 634-m high freestanding broadcasting tower located in a flat terrain at 1m ASL. 25 downward and 37 upward flashes were observed at the tower during 2012 to 2016. This paper focuses on upward negative flashes initiated from the top of the tower. Of the 37 confirmed upward flashes, 35 current waveforms were recorded by Rogowski coils installed at 497-m height of the tower. One out of 35 upward flashes was a positive flash initiated by a negative upward leader, 7 out of 35 flashes were bipolar flashes initiated by positive upward leaders, and the rest were negative flashes initiated by positive upward leaders. The authors evaluated the lightning current parameters of subsequent strokes and initial continuous currents (ICC) of the upward negative flashes.
- Open Access
- 2 April 2018
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 13 (7) , 938-947
Lightning striking characteristics to tall structures
Recently, very tall structures with heights more than several hundred meters have been constructed all over the world and observation of lightning has been made. The striking characteristics obtained from these observations are reviewed, and conventional and new shielding models are discussed. In addition, future themes of studies to be carried out are proposed. © 2018 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 2 April 2018
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 13 (7) , 938-947
Open AccessLightning striking characteristics to tall structures
Recently, very tall structures with heights more than several hundred meters have been constructed all over the world and observation of lightning has been made. The striking characteristics obtained from these observations are reviewed, and conventional and new shielding models are discussed. In addition, future themes of studies to be carried out are proposed. © 2018 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 5 June 2017
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 12 (S1)
Theoretical analysis of concurrent flashover characteristics in a three‐parallel gap configuration
- 5 June 2017
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 12 (S1)
Theoretical analysis of concurrent flashover characteristics in a three‐parallel gap configuration
- 9 December 2016
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 11 (S2)
Lightning occurrence data observed with lightning location systems of electric power companies in Japan: 2009–2013
Nine electric power companies in Japan have been collecting lightning data with lightning location systems. Five years of the lightning data (2009–2013) are summarized and analyzed in this paper. The recent annual number of lightning flashes of which the current is more than 10 kA in Japan is around 1 million. The variations of lightning occurrence characteristics by areas, seasons, and so on, are clarified. Meteorological conditions that may affect lightning occurrence are also discussed. Furthermore, we show that there is a clear correlation between the number of lightning strikes and the outage rate of transmission lines. © 2016 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 9 December 2016
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 11 (S2)
Lightning occurrence data observed with lightning location systems of electric power companies in Japan: 2009–2013
Nine electric power companies in Japan have been collecting lightning data with lightning location systems. Five years of the lightning data (2009–2013) are summarized and analyzed in this paper. The recent annual number of lightning flashes of which the current is more than 10 kA in Japan is around 1 million. The variations of lightning occurrence characteristics by areas, seasons, and so on, are clarified. Meteorological conditions that may affect lightning occurrence are also discussed. Furthermore, we show that there is a clear correlation between the number of lightning strikes and the outage rate of transmission lines. © 2016 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
- 1 January 2015
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 135 (11) , 669-674
Probability of Concurrent Flashover in a Parallel Gap Configuration
- 1 January 2015
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 135 (11) , 669-674
Probability of Concurrent Flashover in a Parallel Gap Configuration
- 1 January 2014
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 134 (5) , 470-471
Observation of Lightning Strikes to TOKYOSKYTREE by using Consumer Digital Camera
In this letter, a lightning observation camera system and an observation result are represented. The system consists of a slow-speed CCTV camera, a consumer high-speed digital camera EXILIM EX-F1S and a personal computer for controlling the camera system. Its total cost is a fraction of standard high-speed cameras used for the lightning observation. Observation of downward lightning strokes to the top of TOKYO SKYTREE was succeeded by the camera system.
- 1 January 2014
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Power and Energy
- Vol. 134 (5) , 470-471
Observation of Lightning Strikes to TOKYOSKYTREE by using Consumer Digital Camera
In this letter, a lightning observation camera system and an observation result are represented. The system consists of a slow-speed CCTV camera, a consumer high-speed digital camera EXILIM EX-F1S and a personal computer for controlling the camera system. Its total cost is a fraction of standard high-speed cameras used for the lightning observation. Observation of downward lightning strokes to the top of TOKYO SKYTREE was succeeded by the camera system.
- 17 July 2012
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 7 (5) , 450-453
Evaluation of diagnostic results by Bayes' theorem
- 17 July 2012
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 7 (5) , 450-453
Evaluation of diagnostic results by Bayes' theorem