Ph. P. Darcis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ph. P. Darcis has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
C. N. Mccowan
NIST, Materials Reliability Division, 325 Broadway, Boulder, CO 80305‐3328, USA
1 shared publicationH. Katsumoto
Sumitomo Metal Industries, Ltd., 3 Hikari, Kashima‐city, Ibaraki, 314‐0014, Japan
1 shared publicationJ. D. McColskey
National Institute of Standards and Technology, Boulder, CO
1 shared publicationJ. D. Mccolskey
NIST, Materials Reliability Division, 325 Broadway, Boulder, CO 80305‐3328, USA
1 shared publicationJ. M. Treinen
National Institute of Standards and Technology, Boulder, CO
1 shared publicationJ. Merritt
U.S. DOT/PHMSA, Washington, DC
1 shared publication
Latest Publications
- 1 December 2008
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 31 (12) , 1065-1078
Crack tip opening angle measurement through a girth weld in an X100 steel pipeline section*
- 1 December 2008
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 31 (12) , 1065-1078
Crack tip opening angle measurement through a girth weld in an X100 steel pipeline section*
- 1 February 2008
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 31 (2) , 125-136
Cruciform fillet welded joint fatigue strength improvements by weld metal phase transformations
- 1 February 2008
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 31 (2) , 125-136
Cruciform fillet welded joint fatigue strength improvements by weld metal phase transformations
- Open Access
- 1 January 2008
- Published by ASME International
- p. 267-272
Effects of Specimen Geometry on Fatigue-Crack Growth Rates in Pipeline Steels
The effects of specimen geometry on the fatigue crack growth rates (FCGR) in API X65 and X100 pipeline steels were explored by use of the middle tension and compact tension specimen geometries. It was found that the specimen type has little influence on the stage II linear fatigue crack growth region for these steels. Furthermore, the FCGR behavior in the longitudinal and transverse directions was found to be nearly identical for both steels. Also of interest was a comparison of the FCGR results to the BS 7910 design curves, which showed a discrepancy between the results and the standard only at low delta K levels. A finite element analysis of the compliance relationships used to predict the crack lengths during testing of both specimen types revealed that the expression for both the middle tension specimen and the compact tension specimen were found to be valid. Although the curved geometry of the middle tension specimen caused slightly different compliance results, these differences did not appear to affect the FCGR results.
- 1 January 2008
- Published by ASME International
- p. 267-272
Open AccessEffects of Specimen Geometry on Fatigue-Crack Growth Rates in Pipeline Steels
The effects of specimen geometry on the fatigue crack growth rates (FCGR) in API X65 and X100 pipeline steels were explored by use of the middle tension and compact tension specimen geometries. It was found that the specimen type has little influence on the stage II linear fatigue crack growth region for these steels. Furthermore, the FCGR behavior in the longitudinal and transverse directions was found to be nearly identical for both steels. Also of interest was a comparison of the FCGR results to the BS 7910 design curves, which showed a discrepancy between the results and the standard only at low delta K levels. A finite element analysis of the compliance relationships used to predict the crack lengths during testing of both specimen types revealed that the expression for both the middle tension specimen and the compact tension specimen were found to be valid. Although the curved geometry of the middle tension specimen caused slightly different compliance results, these differences did not appear to affect the FCGR results.