HGHakan Genchellac

Hakan Genchellac

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hakan Genchellac has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 27 February 2009
      • Vol. 122  (1290) , 124-5

    Medical image. Severe headache when standing. Intracranial hypotension.

    by Osman Temizoz, Hakan Genchellac

  • Computed Tomographic and Magnetic Resonance Imaging Findings of Asymptomatic Intra-Abdominal Gastrointestinal System Lipomas

    by Hakan Genchellac, Mustafa K. Demir, Huseyin Ozdemir, Ercument Unlu, Osman Temizoz

    Lipomas are common benign mesenchymal neoplasms documented in literature. This study aimed to describe the computed tomographic (CT) and magnetic resonance imaging (MRI) findings of gastrointestinal system lipomas, all of which are incidentally found in routine abdominal imaging studies. Lipomas were depicted as homogeneous, nonenhancing, well-marginated lesions consistent with adipose tissue on CT and MRI. The density measurements on CT images consistent with fat are virtually diagnostic. Lipomas can incidentally be found and should be considered in the differential diagnosis of soft tissue gastrointestinal system-related masses. Computed tomographic or MRI examinations can correctly diagnose a lipoma nonoperatively, thereby allowing better treatment planning.


  • Hepatic Pseudolesion Around the Falciform Ligament

    by Hakan Genchellac, Sabri Yilmaz, Adem Ucar, Memduh Dursun, Mustafa Kemal Demir, Ensar Yekeler

    The aim of this study was to determine the prevalence and aberrant venous supply (inferior veins of Sappey) of hypoattenuating hepatic pseudolesions seen around the falciform ligament on portal-dominant phase multidetector computed tomography (MDCT) and the frequency of fatty infiltration of these pseudolesions on chemical-shift magnetic resonance imaging. Portal-dominant phase abdominal MDCT examinations of 728 patients were evaluated for the presence of a pseudolesion around the falciform ligament, and those with a presumed pseudolesion underwent chemical-shift magnetic resonance imaging to detect the fatty infiltration. Reconstructed MDCT images were investigated for the presence of an inferior vein of Sappey, and 30 patients without a pseudolesion were evaluated as a control group. A total of 160 pseudolesions were detected around the falciform ligament in 146 (20%) patients. The longest diameter of the pseudolesions was in the craniocaudal direction in most patients (61%). An inferior vein of Sappey supplying these pseudolesions was depicted in 40 (27%) patients, and it was highly significant (P = 0.001) compared with the controls for the presence of a pseudolesion around the falciform ligament. Fatty infiltration was found in 47 (29%) patients. Hepatic pseudolesions around the falciform ligament are frequently encountered on portal-dominant phase MDCT images. Detection of craniocaudal extension, inferior veins of Sappey, and fatty infiltration of these pseudolesions, which were firstly described in this article, with the largest subject group based on cross-sectional imaging, might be valuable in excluding true tumors.


  • Comparison of the Image Quality on Low-dose Urinary Tract Multidetector CT Examinations with 80 kVp and 120 kVp (Original Research)

    by Ensar Yekeler, Candan Ozdemir, Sabri Yilmaz, Alim Topcu, Hakan Genchellac, Atadan Tunaci, Gulden Acunas

    Purpose: To compare the image quality on low-dose urinary tract multidetector CT examinations with 80 kVp and 120 kVp. Materials and Methods: Seventy-six patients with urinary tract symptoms were evaluated for urinary tract calculi by unenhanced multidetector CT. The examinations were performed with a four-row detector CT scanner. In all patients, two low-dose CT examinations with different kVp and mAs values (120 kVp, 30 mAs and 80 kVp, 95 mAs) were performed. The other scanning parameters were kept constant. Weighted-CT dose index was equal in both examinations. Both CT examinations were quantitatively compared with calculating the HU values of kidneys, subcutaneous fat, calculus, and phleboliths and the HU ratio of urinary calculi to the kidney. Both scans were also qualitatively compared for image quality of upper and lower abdomen. Results: One hundred and two calculi were detected in 50 of 76 patients. One or more phleboliths were present in 20 patients. HU values of the phleboliths and urinary calculi were higher on images obtained with 80 kVp than those obtained with 120 kVp. HU ratio of the calculi to the kidney was higher on scans with 80 kVp. Adipose tissue was less noisy and had lower HU value on 80 kVp images. Image quality of the upper abdomen and major pelvis were better on 80 kVp images, and the majority of these patients were normal (n=28) and overweight (n=20). Minor pelvis mostly (60%) revealed poorer image quality on 80 kVp images. However, the majority were overweight (n=22) or obese (n=6). In patients with osteoporosis, image quality was relatively better when compared with similar weighed patients without osteoporosis on 80 kVp images. Small renal, proximal and middle ureteral calculi were better demarcated on 80 kVp images. Conclusion: Low-dose urinary tract multidetector CT examination with 80 kVp, compared to 120 kVp provides better image quality in the upper abdomen and major pelvis. In overweight and obese patients, minor pelvis may not be evaluated thoroughly on 80 kVp images. Detection of small renal, proximal and middle ureteral calculi could be improved by using 80 kVp setting.


  • MDCT Appearance of Idiopathic Saccular Aneurysm of the Inferior Vena Cava

    by Ensar Yekeler, Hakan Genchellac, Haldun Emiroglu, Turkan Elmaci, Bugra Harmandar, Hakan Genchellac Ensar Yekeler, Sung Eun Rha, Jae Young Byun, Seung Eun Jung, Hyo Lim Kim, et al.