Zhengjin Jiang
Zhengjin Jiang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Brian Everatt
3 shared publications- John Reilly
Novartis Institutes for Biomedical Research, Horsham Research Centre, Wimblehurst Road, Horsham, West Sussex RH12 5AB, United Kingdom
3 shared publications Norman W. Smith
Pharmaceutical Sciences Research Division, King's College London, London, UK
2 shared publicationsEmmanuelle Briard
1 shared publicationMark R. Taylor
Research Analytics, Pfizer Global R and D, Sandwich, Kent, UK
1 shared publicationNorman Williams Smith
1 shared publication
Latest Publications
- 1 March 2011
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 54 (4) , 722-729
A rapid vesicle electrokinetic chromatography method for the in vitro prediction of non-specific binding for potential PET ligands
- 1 March 2011
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 54 (4) , 722-729
A rapid vesicle electrokinetic chromatography method for the in vitro prediction of non-specific binding for potential PET ligands
- 1 February 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1217 (7) , 1149-1156
Highlighting the possible secondary interactions in the role of balhimycin and its analogues for enantiorecognition in capillary electrophoresis
- 1 February 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1217 (7) , 1149-1156
Highlighting the possible secondary interactions in the role of balhimycin and its analogues for enantiorecognition in capillary electrophoresis
- 7 August 2009
- Published by Wiley in Journal of Separation Science
- Vol. 32 (15-16) , 2544-2555
Novel highly hydrophilic zwitterionic monolithic column for hydrophilic interaction chromatography
A novel zwitterionic hydrophilic porous poly(SPV‐co‐MBA) monolithic column was prepared by thermal co‐polymerisation of 1‐(3‐sulphopropyl)‐4‐vinylpyridinium‐betaine (4‐SPV) and N,N′‐methylenebisacrylamide (MBA). An HILIC/RP dual separation mechanism was observed on this optimised poly(SPV‐co‐MBA) monolithic column and the composition of the mobile phase corresponding to the transition from the HILIC to the RP mode was around 30% ACN in water. Higher hydrophilicity was achieved on this novel monolithic column compared to the poly(N,N‐dimethyl‐N‐methacryloxyethyl‐N‐(3‐sulphopropyl)ammonium betaine‐co‐ethylene dimethacrylate) monolithic column. Permeability studies showed slight swelling and/or shrinking with mobile phases of different polarity. As might be anticipated, a weak electrostatic interaction for charged analytes was also observed by studying the influence of mobile phase pH and salt concentration on their retention on the poly(SPV‐co‐MBA) monolithic column. The final optimised poly(SPV‐co‐MBA) monolith showed comparable selectivities to commercial ZIC‐pHILIC phases for polar test analytes. Fast separation of five pyrimidines and purines was achieved in less than 1 min due to the high permeability of the monolithic column. Additionally, baseline separation of nine benzoic acid derivatives was also observed using either a pH or ACN gradient.
- 7 August 2009
- Published by Wiley in Journal of Separation Science
- Vol. 32 (15-16) , 2544-2555
Novel highly hydrophilic zwitterionic monolithic column for hydrophilic interaction chromatography
A novel zwitterionic hydrophilic porous poly(SPV‐co‐MBA) monolithic column was prepared by thermal co‐polymerisation of 1‐(3‐sulphopropyl)‐4‐vinylpyridinium‐betaine (4‐SPV) and N,N′‐methylenebisacrylamide (MBA). An HILIC/RP dual separation mechanism was observed on this optimised poly(SPV‐co‐MBA) monolithic column and the composition of the mobile phase corresponding to the transition from the HILIC to the RP mode was around 30% ACN in water. Higher hydrophilicity was achieved on this novel monolithic column compared to the poly(N,N‐dimethyl‐N‐methacryloxyethyl‐N‐(3‐sulphopropyl)ammonium betaine‐co‐ethylene dimethacrylate) monolithic column. Permeability studies showed slight swelling and/or shrinking with mobile phases of different polarity. As might be anticipated, a weak electrostatic interaction for charged analytes was also observed by studying the influence of mobile phase pH and salt concentration on their retention on the poly(SPV‐co‐MBA) monolithic column. The final optimised poly(SPV‐co‐MBA) monolith showed comparable selectivities to commercial ZIC‐pHILIC phases for polar test analytes. Fast separation of five pyrimidines and purines was achieved in less than 1 min due to the high permeability of the monolithic column. Additionally, baseline separation of nine benzoic acid derivatives was also observed using either a pH or ACN gradient.
- 1 March 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (12) , 2439-2448
Novel zwitterionic polyphosphorylcholine monolithic column for hydrophilic interaction chromatography
- 1 March 2009
- Published by Elsevier in Journal of Chromatography A
- Vol. 1216 (12) , 2439-2448
Novel zwitterionic polyphosphorylcholine monolithic column for hydrophilic interaction chromatography
- 1 August 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (17) , 3674-3684
A method for rapidly predicting drug tissue distribution using surfactant vesicle electrokinetic chromatography
Lung tissue distribution of an inhaled drug is important for its potency in the airways and with minimum systemic effects within its dose range. As the lung has the smallest diffusion distance of all the organs in the body and negligible diffusion delays, the characteristics of drug distribution in the lung will mainly depend on drug binding to both tissue and plasma protein. This research aims to develop and evaluate surfactant vesicle electrokinetic chromatography (SEKC) methods for high throughput profile prediction of tissue distribution for inhaled drugs. Several electrokinetic chromatography methods reported in the literature, as well as immobilised artificial membrane chromatography, were compared and evaluated in respect to chromatographic characteristics and statistical correlations. Among these methods, the docusate sodium salt (AOT) SEKC system showed good reproducibility, short run time, and the highest selectivity for alkylphenone test compounds. It also showed a significant statistical correlation between the retention of inhaled drugs and their in vivo volume of distribution at steady‐state (Vss) in whole human body neglecting the plasma protein‐binding differences. Stronger correlations were observed between the AOT SEKC retention of a series of basic drugs and their rat lung tissue‐to‐plasma water partitioning coefficient (Kpu), which is affected only by drug binding to the tissue constituent. Further, on comparing correlations between AOT SEKC retention and Kpu at various rat tissues, it was observed that the strongest correlation was with lung tissue distribution, while the weakest was with brain tissue distribution.
- 1 August 2008
- Published by Wiley in Electrophoresis
- Vol. 29 (17) , 3674-3684
A method for rapidly predicting drug tissue distribution using surfactant vesicle electrokinetic chromatography
Lung tissue distribution of an inhaled drug is important for its potency in the airways and with minimum systemic effects within its dose range. As the lung has the smallest diffusion distance of all the organs in the body and negligible diffusion delays, the characteristics of drug distribution in the lung will mainly depend on drug binding to both tissue and plasma protein. This research aims to develop and evaluate surfactant vesicle electrokinetic chromatography (SEKC) methods for high throughput profile prediction of tissue distribution for inhaled drugs. Several electrokinetic chromatography methods reported in the literature, as well as immobilised artificial membrane chromatography, were compared and evaluated in respect to chromatographic characteristics and statistical correlations. Among these methods, the docusate sodium salt (AOT) SEKC system showed good reproducibility, short run time, and the highest selectivity for alkylphenone test compounds. It also showed a significant statistical correlation between the retention of inhaled drugs and their in vivo volume of distribution at steady‐state (Vss) in whole human body neglecting the plasma protein‐binding differences. Stronger correlations were observed between the AOT SEKC retention of a series of basic drugs and their rat lung tissue‐to‐plasma water partitioning coefficient (Kpu), which is affected only by drug binding to the tissue constituent. Further, on comparing correlations between AOT SEKC retention and Kpu at various rat tissues, it was observed that the strongest correlation was with lung tissue distribution, while the weakest was with brain tissue distribution.