Hanan Datz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hanan Datz has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Ada Juster-Reicher
Kaplan Medical Center, Department of Neonatology, Rehovot , Israel
1 shared publication- Alessandra Zorz
Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy
1 shared publication - Ann McCann
Department of Medical Physics and Clinical Engineering, St. Vincent's University Hospital, Dublin, Ireland
1 shared publication Avi Ben-Shlomo
Soreq Nuclear Research Center, Radiation Safety Division, Yavne , Israel
1 shared publicationDavid Bader
Bnai-Zion Medical Center, Department of Neonatology, Haifa , Israel
1 shared publicationDimitri Batani
1 shared publication
Latest Publications
- 7 July 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (3) , 031504
Assessment of the extremity exposure during preparation and administration of 177 Lu – results of a multi-center study
Despite the increased use of 177 Lu in nuclear medicine (NM) over the last 10 years, the knowledge of the actual exposure of the extremities due to manipulation of this pharmaceutical is limited. The purpose of this study is to assess the extremity dose during the preparation and administration of 177 Lu-labelled radiopharmaceuticals in a wide range of NM practices. Workers in 10 NM centres throughout Europe wore a ring dosimeter on the base of the index finger of the non-dominant hand during preparation and/or administration of 177 Lu-labelled radiopharmaceuticals. Information on manipulated activity, tasks performed and protection measures was collected to allow sub-analyses. The median ring dose per monitoring interval was 0.16 mSv, with a maximum of 2.27 mSv in one month. The median normalised dose amounted 3.5 µ Sv GBq −1 (range 0.5–525). The highest monthly doses were found for workers involved in preparation of the pharmaceutical. The workers performing manual administrations (6.5 µ Sv GBq −1 ) showed higher normalised ring doses than those using the gravity method (3.5 µ Sv GBq −1 ) or a syringe pump (1.0 µ Sv GBq −1 ). Explanations for the wide range of normalised ring doses may be found in the different techniques applied in this study and the differences in minimum reportable doses of the dosimeters. When the data is extrapolated using a fingertip to ring dose ratio of 5, an annual fingertip dose of 1–136 mSv is found, with a median fingertip dose of 10 mSv per year. Extremity exposure during 177 Lu handling remained well below dose limits. The highest normalised doses occurred during preparation and manual administration. Overall, this investigation shows doses remain low when appropriate radiation protection measures (e.g. shielding and minimising time at short distance) are being applied.
- 7 July 2026
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 46 (3) , 031504
Assessment of the extremity exposure during preparation and administration of 177 Lu – results of a multi-center study
Despite the increased use of 177 Lu in nuclear medicine (NM) over the last 10 years, the knowledge of the actual exposure of the extremities due to manipulation of this pharmaceutical is limited. The purpose of this study is to assess the extremity dose during the preparation and administration of 177 Lu-labelled radiopharmaceuticals in a wide range of NM practices. Workers in 10 NM centres throughout Europe wore a ring dosimeter on the base of the index finger of the non-dominant hand during preparation and/or administration of 177 Lu-labelled radiopharmaceuticals. Information on manipulated activity, tasks performed and protection measures was collected to allow sub-analyses. The median ring dose per monitoring interval was 0.16 mSv, with a maximum of 2.27 mSv in one month. The median normalised dose amounted 3.5 µ Sv GBq −1 (range 0.5–525). The highest monthly doses were found for workers involved in preparation of the pharmaceutical. The workers performing manual administrations (6.5 µ Sv GBq −1 ) showed higher normalised ring doses than those using the gravity method (3.5 µ Sv GBq −1 ) or a syringe pump (1.0 µ Sv GBq −1 ). Explanations for the wide range of normalised ring doses may be found in the different techniques applied in this study and the differences in minimum reportable doses of the dosimeters. When the data is extrapolated using a fingertip to ring dose ratio of 5, an annual fingertip dose of 1–136 mSv is found, with a median fingertip dose of 10 mSv per year. Extremity exposure during 177 Lu handling remained well below dose limits. The highest normalised doses occurred during preparation and manual administration. Overall, this investigation shows doses remain low when appropriate radiation protection measures (e.g. shielding and minimising time at short distance) are being applied.
- 6 November 2024
- Published by Wolters Kluwer Health in Health Physics
- Vol. 128 (2) , 148-155
A Novel Anthropometric Phantom for Rapid Radiological Triage: A Quick Sort Triage Solution
Rapidly identifying individuals who have received internal radiation exposure above action guidelines is crucial for mitigating health risks and addressing public concerns immediately following a radiological event involving the dispersal of radioactive materials. This study describes a novel triage method using a conventional Geiger-Mueller (GM) detector to select those individuals from the large group of persons who may have received an intake of radioactive material at levels corresponding to one Clinical Decision Guide (CDG). The triage method involves placing a portable GM detector against the lower anterior torso of a sitting person as they bend over to surround the detector with their body. The response of the GM detector is evaluated using a new, specially designed anthropometric phantom that simulates combined tissues of the lower thorax and gastrointestinal (GI) tract and is fabricated with a tissue substitute material that matches the overall radiological properties of human tissue present in this body region. The phantom has four separate layers of tissue substitute material with ports to accommodate a single GM detector at the center and one or more sealed radioactive sources that can be arranged to characterize the detector response for a variety of source distributions, including a “hot spot.” In this study, the response of a Ludlum Model 133-4 GM detector was evaluated using sealed sources of 232Th and 137Cs to determine the measurement efficiency for a quantity of activity present in the abdomen within a few hours post-intake equivalent to 1 CDG. Results demonstrate that the Quick Sort triage procedure using a single GM detector placed against the abdomen of a person can reliably detect internal deposition resulting from an intake equivalent to 1 CDG for 232Th or a significantly lower activity of 137Cs within a few hours following a radiological incident. The evaluation was performed over a wide range of photon energies, so the Quick Sort triage procedure is expected to be suitable for most fission products distributed uniformly within the abdomen or as a single “hot spot.”
- 6 November 2024
- Published by Wolters Kluwer Health in Health Physics
- Vol. 128 (2) , 148-155
A Novel Anthropometric Phantom for Rapid Radiological Triage: A Quick Sort Triage Solution
Rapidly identifying individuals who have received internal radiation exposure above action guidelines is crucial for mitigating health risks and addressing public concerns immediately following a radiological event involving the dispersal of radioactive materials. This study describes a novel triage method using a conventional Geiger-Mueller (GM) detector to select those individuals from the large group of persons who may have received an intake of radioactive material at levels corresponding to one Clinical Decision Guide (CDG). The triage method involves placing a portable GM detector against the lower anterior torso of a sitting person as they bend over to surround the detector with their body. The response of the GM detector is evaluated using a new, specially designed anthropometric phantom that simulates combined tissues of the lower thorax and gastrointestinal (GI) tract and is fabricated with a tissue substitute material that matches the overall radiological properties of human tissue present in this body region. The phantom has four separate layers of tissue substitute material with ports to accommodate a single GM detector at the center and one or more sealed radioactive sources that can be arranged to characterize the detector response for a variety of source distributions, including a “hot spot.” In this study, the response of a Ludlum Model 133-4 GM detector was evaluated using sealed sources of 232Th and 137Cs to determine the measurement efficiency for a quantity of activity present in the abdomen within a few hours post-intake equivalent to 1 CDG. Results demonstrate that the Quick Sort triage procedure using a single GM detector placed against the abdomen of a person can reliably detect internal deposition resulting from an intake equivalent to 1 CDG for 232Th or a significantly lower activity of 137Cs within a few hours following a radiological incident. The evaluation was performed over a wide range of photon energies, so the Quick Sort triage procedure is expected to be suitable for most fission products distributed uniformly within the abdomen or as a single “hot spot.”
- Open Access
- 29 June 2022
- Published by Cambridge University Press (CUP) in Laser and Particle Beams
- Vol. 2022
Particles Detection System with CR-39 Based on Deep Learning
We present a novel method that we call FAINE, fast artificial intelligence neutron detection system. FAINE automatically classifies tracks of fast neutrons on CR-39 detectors using a deep learning model. This method was demonstrated using a LANDAUER Neutrak® fast neutron dosimetry system, which is installed in the External Dosimetry Laboratory (EDL) at Soreq Nuclear Research Center (SNRC). In modern fast neutron dosimetry systems, after the preliminary stages of etching and imaging of the CR-39 detectors, the third stage uses various types of computer vision systems combined with a manual revision to count the CR-39 tracks and then convert them to a dose in mSv units. Our method enhances these modern systems by introducing an innovative algorithm, which uses deep learning to classify all CR-39 tracks as either real neutron tracks or any other sign such as dirt, scratches, or even cleaning remainders. This new algorithm makes the third stage of manual CR-39 tracks revision superfluous and provides a completely repeatable and accurate way of measuring either neutrons flux or dose. The experimental results show a total accuracy rate of 96.7% for the true positive tracks and true negative tracks detected by our new algorithm against the current method, which uses computer vision followed by manual revision. This algorithm is now in the process of calibration for both alpha-particles detection and fast neutron spectrometry classification and is expected to be very useful in analyzing results of proton-boron11 fusion experiments. Being fully automatic, the new algorithm will enhance the quality assurance and effectiveness of external dosimetry, will lower the uncertainty for the reported dose measurements, and might also enable lowering the system’s detection threshold.
- 29 June 2022
- Published by Cambridge University Press (CUP) in Laser and Particle Beams
- Vol. 2022
Open AccessParticles Detection System with CR-39 Based on Deep Learning
We present a novel method that we call FAINE, fast artificial intelligence neutron detection system. FAINE automatically classifies tracks of fast neutrons on CR-39 detectors using a deep learning model. This method was demonstrated using a LANDAUER Neutrak® fast neutron dosimetry system, which is installed in the External Dosimetry Laboratory (EDL) at Soreq Nuclear Research Center (SNRC). In modern fast neutron dosimetry systems, after the preliminary stages of etching and imaging of the CR-39 detectors, the third stage uses various types of computer vision systems combined with a manual revision to count the CR-39 tracks and then convert them to a dose in mSv units. Our method enhances these modern systems by introducing an innovative algorithm, which uses deep learning to classify all CR-39 tracks as either real neutron tracks or any other sign such as dirt, scratches, or even cleaning remainders. This new algorithm makes the third stage of manual CR-39 tracks revision superfluous and provides a completely repeatable and accurate way of measuring either neutrons flux or dose. The experimental results show a total accuracy rate of 96.7% for the true positive tracks and true negative tracks detected by our new algorithm against the current method, which uses computer vision followed by manual revision. This algorithm is now in the process of calibration for both alpha-particles detection and fast neutron spectrometry classification and is expected to be very useful in analyzing results of proton-boron11 fusion experiments. Being fully automatic, the new algorithm will enhance the quality assurance and effectiveness of external dosimetry, will lower the uncertainty for the reported dose measurements, and might also enable lowering the system’s detection threshold.
- 29 December 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 170 (1-4) , 407-411
STUDY OF THE SUITABILITY OF ISRAELI HOUSEHOLD SALT FOR RETROSPECTIVE DOSIMETRY
The first results of an in-depth evaluation of the practical potential of common household Israeli salt as a retrospective dosemeter in the event of a nuclear accident or terror attack are presented. Ten brands of salt were investigated with emphasis on four of the bestselling brands that constitute 76 % of the total consumer market. Eight of the ten brands show similar glow curves with two main glow peaks at maximum temperatures of ∼176°C and ∼225°C measured at a heating rate of 1°C s−1. Chemical analysis of three major brands indicates substantial impurity levels of 200–500 ppm of Ca, K, Mg and S and significant differences of additional ppm trace impurities, which lead to an ∼50 % difference in the TL response of the three major brands. Fading in the dark is in significant but under room light is of the order of 35 % per day. The dose response is linear/supralinear with the threshold of supralinearity at ∼0.01 Gy reaching maximum value of ∼4 at 0.5–1 Gy for two of the major brands. The precision of repeated measurements is ∼10 % (1 SD), but the accuracy of dose assessment under field conditions requires further study.
- 29 December 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 170 (1-4) , 407-411
STUDY OF THE SUITABILITY OF ISRAELI HOUSEHOLD SALT FOR RETROSPECTIVE DOSIMETRY
The first results of an in-depth evaluation of the practical potential of common household Israeli salt as a retrospective dosemeter in the event of a nuclear accident or terror attack are presented. Ten brands of salt were investigated with emphasis on four of the bestselling brands that constitute 76 % of the total consumer market. Eight of the ten brands show similar glow curves with two main glow peaks at maximum temperatures of ∼176°C and ∼225°C measured at a heating rate of 1°C s−1. Chemical analysis of three major brands indicates substantial impurity levels of 200–500 ppm of Ca, K, Mg and S and significant differences of additional ppm trace impurities, which lead to an ∼50 % difference in the TL response of the three major brands. Fading in the dark is in significant but under room light is of the order of 35 % per day. The dose response is linear/supralinear with the threshold of supralinearity at ∼0.01 Gy reaching maximum value of ∼4 at 0.5–1 Gy for two of the major brands. The precision of repeated measurements is ∼10 % (1 SD), but the accuracy of dose assessment under field conditions requires further study.
- 28 March 2008
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 130 (4) , 518-524
The additional dose to radiosensitive organs caused by using under-collimated X-ray beams in neonatal intensive care radiography
Radiographic technique and exposure parameters were recorded in five Israeli Neonatal Intensive Care Units for chest, abdomen and both chest and abdomen X-ray examinations. Equivalent dose and effective dose values were calculated according to actual examination field size borders and proper technique field size recommendations using PCXMC, a PC-based Monte Carlo program. Exposure of larger than required body areas resulted in an increase of the organ doses by factors of up to 162 (testes), 162 (thyroid) and 8 (thyroid) for chest, abdomen and both chest and abdomen examinations, respectively. These exposures increased the average effective dose by factors of 2.0, 1.9 and 1.3 for the chest, abdomen and both chest and abdomen examinations, respectively. Differences in exposure parameters were found between the different neonatal intensive care units—tube voltage, current–time product and focal to skin distance differences up to 13, 44 and 22%, respectively. Reduction of at least 50% of neonate exposure is feasible and can be implemented using existing methodology without any additional costs.
- 28 March 2008
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 130 (4) , 518-524
The additional dose to radiosensitive organs caused by using under-collimated X-ray beams in neonatal intensive care radiography
Radiographic technique and exposure parameters were recorded in five Israeli Neonatal Intensive Care Units for chest, abdomen and both chest and abdomen X-ray examinations. Equivalent dose and effective dose values were calculated according to actual examination field size borders and proper technique field size recommendations using PCXMC, a PC-based Monte Carlo program. Exposure of larger than required body areas resulted in an increase of the organ doses by factors of up to 162 (testes), 162 (thyroid) and 8 (thyroid) for chest, abdomen and both chest and abdomen examinations, respectively. These exposures increased the average effective dose by factors of 2.0, 1.9 and 1.3 for the chest, abdomen and both chest and abdomen examinations, respectively. Differences in exposure parameters were found between the different neonatal intensive care units—tube voltage, current–time product and focal to skin distance differences up to 13, 44 and 22%, respectively. Reduction of at least 50% of neonate exposure is feasible and can be implemented using existing methodology without any additional costs.