MDMarco Das

Marco Das

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marco Das has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Carotid Plaque Analysis: Comparison of Dual-Source Computed Tomography (CT) Findings and Histopathological Correlation

    by M. Das, T. Braunschweig, G. Mühlenbruch, A.H. Mahnken, T. Krings, S. Langer, T. Koeppel, M. Jacobs, R.W. Günther, G. Mommertz


  • Performance evaluation of a computer-aided detection algorithm for solid pulmonary nodules in low-dose and standard-dose MDCT chest examinations and its influence on radiologists

    by M DAS, G Mühlenbruch, S Heinen, A H Mahnken, M Salganicoff, S Stanzel, R W Günther, J E Wildberger

    The aim of the study was to evaluate the performance of a computer-aided detection (CAD) algorithm in low-dose and full-dose multidetector-row CT (MDCT) of the thorax and its impact on radiologists' performance. Chest CT examinations of 77 patients were evaluated retrospectively for pulmonary nodules. All patients had undergone a 16-slice MDCT chest examination with a standard acquisition protocol. Artificial image noise was added to the raw data to simulate image acquisition at 10 mAs(eff.) The data were transferred to dedicated lung analysis software (LungCare) with a prototype CAD algorithm (LungCAD). CAD was applied to both dose settings. Images were read by a radiologist and a first-year resident with and without the software at both dose settings. All images were reviewed in consensus by the two radiologists to set the reference standard. Sensitivity results with respect to the reference standard were compared. No statistically significant differences in the detection rate for all pulmonary nodules could be found between low-dose and full-dose settings for the CAD software alone (p = 0.0065). Both radiologists displayed a statistically significant increase in sensitivity with the use of CAD (p<0.0001). In conclusion, CAD is beneficial in both low-dose and standard-dose settings. This may be beneficial in reducing false-negative diagnosis in lung cancer screening, standard chest examinations and the search for metastases.


  • Computer-aided detection of pulmonary embolism: Influence on radiologists’ detection performance with respect to vessel segments

    by Marco Das, Georg Mühlenbruch, Anita Helm, Annemarie Bakai, Marcos Salganicoff, Sven Stanzel, Jianming Liang, Matthias Wolf, Rolf W. Günther, Joachim Ernst Wildberger

    The purpose was to assess the sensitivity of a CAD software prototype for the detection of pulmonary embolism in MDCT chest examinations with regard to vessel level and to assess the influence on radiologists’ detection performance. Forty-three patients with suspected PE were included in this retrospective study. MDCT chest examinations with a standard PE protocol were acquired at a 16-slice MDCT. All patient data were read by three radiologists (R1, R2, R3), and all thrombi were marked. A CAD prototype software was applied to all datasets, and each finding of the software was analyzed with regard to vessel level. The standard of reference was assessed in a consensus read. Sensitivity for the radiologists and CAD software was assessed. Thirty-three patients were positive for PE, with a total of 215 thrombi. The mean overall sensitivity for the CAD software alone was 83% (specificity, 80%). Radiologist sensitivity was 77% = R3, 82% = R2, and R1 = 87%. With the aid of the CAD software, sensitivities increased to 98% (R1), 93% (R2), and 92% (R3) (p<0.0001). CAD performance at the lobar level was 87%, at the segmental 90% and at the subsegmental 77%. With the use of CAD for PE, the detection performance of radiologists can be improved.


  • Current Status of Lung Ventilation Imaging with Magnetic Resonance Ventilation Scanning Using Aerosolized Contrast Agents

    by Marco Das, Rolf W. Gunther, Patrick Haage

    Chronic respiratory diseases are one of the leading causes of death and morbidity. Therefore the assessment of regional and global ventilation distribution together with pulmonary perfusion imaging becomes more and more important. To date either radionuclide ventilation scintigraphy or high-resolution computed tomography (HR-CT) are used for ventilation assessment and pulmonary parenchyma analysis. But scintigraphy lacks spatial and temporal resolution while HR-CT applies radiation and lacks functional analysis. Over the last years Magnetic resonance imaging (MRI) of the lung has evolved by using aerosolized contrast agents. MRI offers morphological and functional information and does not apply radiation dose. Approaches to use hyperpolarized gases like Xenon and Helium have been made, but these gases are complex and expensive to produce and use. Lately the use of widely available contrast agents like gadolinium chelates has been investigated. As no special MR hardware is needed and gadolinium is straightforward to apply this new method yields promising results for the future. This review is to give an overview about current developments and methods in Gadolinium-enhanced MR ventilation.

  • Automated Volumetry of Solid Pulmonary Nodules in a Phantom

    by Marco Das, Georg Mühlenbruch, Markus Katoh, Annemarie Bakai, Marcos Salganicoff, Sven Stanzel, Andreas H Mahnken, Rolf W Günther, Joachim E Wildberger

    The accuracy of automated volumetry for pulmonary nodules in a phantom using different CT scanner technologies from single-slice spiral CT (SSCT) to 64-slice multidetector-row CT (MDCT) was compared. A lung phantom with 5 different categories of pulmonary nodules was scanned using a single-slice spiral CT, a 4-slice MDCT, a 16-slice MDCT and a 64-slice MDCT. Each category comprised of 7–9 nodules each (total n = 40) with different known volumes. Standard dose and low dose protocols were performed using thin and thick collimation. Image data were reconstructed at the thinnest slice thickness. Data sets were analyzed with a dedicated volumetry software. Volumes of all nodules were calculated and compared. Mean absolute percentage error (APE) for all nodules was 8.65% (±7.29%) for the SSCT, 10.26% (±8.25%) for the 4-slice MDCT, 8.19% (±7.57%) for the 16-slice MDCT and 7.89% (±7.39%) for the 64-slice MDCT. There was statistically significant influence of the scanner type, protocol, anatomic location, and nodule volume on APE, but overall, APEs were comparable. Computer-aided volumetry showed accurate measurements in all tested scanner types. This finding has important implications for nodule assessment and follow-up.


  • Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners

    by Marco Das, Julia Ley-Zaporozhan, H. A. Gietema, Andre Czech, Georg Mühlenbruch, Andreas H. Mahnken, Markus Katoh, Annemarie Bakai, Marcos Salganicoff, Stefan Diederich, et al.

    The purpose of this study was to compare the accuracy of an automated volumetry software for phantom pulmonary nodules across various 16-slice multislice spiral CT (MSCT) scanners from different vendors. A lung phantom containing five different nodule categories (intraparenchymal, around a vessel, vessel attached, pleural, and attached to the pleura), with each category comprised of 7–9 nodules (total, n = 40) of varying sizes (diameter 3–10 mm; volume 6.62 mm3–525 mm3), was scanned with four different 16-slice MSCT scanners (Siemens, GE, Philips, Toshiba). Routine and low-dose chest protocols with thin and thick collimations were applied. The data from all scanners were used for further analysis using a dedicated prototype volumetry software. Absolute percentage volume errors (APE) were calculated and compared. The mean APE for all nodules was 8.4% (±7.7%) for data acquired with the 16-slice Siemens scanner, 14.3% (±11.1%) for the GE scanner, 9.7% (±9.6%) for the Philips scanner and 7.5% (±7.2%) for the Toshiba scanner, respectively. The lowest APEs were found within the diameter size range of 5–10 mm and volumes >66 mm3. Nodule volumetry is accurate with a reasonable volume error in data from different scanner vendors. This may have an important impact for intraindividual follow-up studies.


  • Small Pulmonary Nodules: Effect of Two Computer-aided Detection Systems on Radiologist Performance

    by Marco Das, Georg Mühlenbruch, Andreas H. Mahnken, Thomas G. Flohr, Lutz Gündel, Sven Stanzel, Thomas Kraus, Rolf W. Günther, Joachim E. Wildberger

    Purpose: To prospectively compare the effects of two computer-aided detection (CAD) systems on the detection of small pulmonary nodules at multi–detector row computed tomography (CT) by using a consensus panel decision as the reference standard. Materials and Methods: Institutional review board approval and informed consent were obtained. Multi–detector row CT scans were randomly chosen and prospectively evaluated in 25 patients. Two dedicated CAD systems—ImageChecker CT (R2 Technologies, Sunnyvale, Calif) and Nodule Enhanced Viewing (NEV) (Siemens Medical Solutions, Forchheim, Germany)—were used. Results were interpreted by three radiologists with 1, 3, and 6 years of experience. Images were evaluated without and with CAD software. The reference standard was assessed by a consensus panel consisting of all three radiologists and an adjudicator with 8 years of experience. Results: A total of 116 pulmonary nodules (average diameter, 3.4 mm; average volume, 32.05 mm3) were found in all data sets during conse...


  • Asbestos Surveillance Program Aachen (ASPA): initial results from baseline screening for lung cancer in asbestos-exposed high-risk individuals using low-dose multidetector-row CT

    by Marco Das, Georg Mühlenbruch, Andreas H. Mahnken, K. G. Hering, H. Sirbu, W. Zschiesche, Lars Knoll, Michael K. Felten, Thomas Kraus, Rolf W. Günther, et al.

    The purpose of this study was to assess the prevalence of lung cancer in a high-risk asbestos-exposed cohort using low-dose MDCT. Of a population of 5,389 former power-plant workers, 316 were characterized as individuals at highest risk for lung cancer according to a lung-cancer risk model including age, asbestos exposure and smoking habits. Of these 316, 187 (mean age: 66.6 years) individuals were included in a prospective trial. Mean asbestos exposure time was 29.65 years and 89% were smokers. Screening was performed on a 16-slice MDCT (Siemens) with low-dose technique (10/20 mAseff.; 1 mm/0.5 mm increment). In addition to soft copy PACS reading analysis on a workstation with a dedicated lung analysis software (LungCARE; Siemens) was performed. One strongly suspicious mass and eight cases of histologically proven lung cancer were found plus 491 additional pulmonary nodules (average volume: 40.72 ml, average diameter 4.62 mm). Asbestos-related changes (pleural plaques, fibrosis) were visible in 80 individuals. Lung cancer screening in this high-risk cohort showed a prevalence of lung cancer of 4.28% (8/187) at baseline screening with an additional large number of indeterminate pulmonary nodules. Low-dose MDCT proved to be feasible in this highly selected population.


  • Optimized image reconstruction for detection of deep venous thrombosis at multidetector-row CT venography

    by Marco Das, Georg Mühlenbruch, Andreas Horst Mahnken, Claudia Weiß, U. Joseph Schoepf, Christianne Leidecker, Rolf W. Günther, Joachim Ernst Wildberger