Uwe Fischer
Uwe Fischer has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
E. Grabbe
3 shared publicationsF. Baum
3 shared publicationsR. Vosshenrich
3 shared publicationsFriedemann Baum
2 shared publicationsB. Salamat
Department of Radiology, Georg August University, Robert-Koch-Strasse 40, 37075 Goettingen, Germany
1 shared publicationC. Schorn
Abt. Röntgendiagnostik I der Georg-August-Universität Göttingen
1 shared publication
Latest Publications
- 31 August 2006
- Published by Elsevier in Magnetic Resonance Imaging Clinics of North America
- Vol. 14 (3) , 351-362
Preoperative MR Imaging in Patients with Breast Cancer: Preoperative Staging, Effects on Recurrence Rates, and Outcome Analysis
- 31 August 2006
- Published by Elsevier in Magnetic Resonance Imaging Clinics of North America
- Vol. 14 (3) , 351-362
Preoperative MR Imaging in Patients with Breast Cancer: Preoperative Staging, Effects on Recurrence Rates, and Outcome Analysis
- 10 July 2004
- Published by Springer Nature in European Radiology
- Vol. 14 (10) , 1725-1731
The influence of preoperative MRI of the breasts on recurrence rate in patients with breast cancer
Preoperative MRI of the breasts has been proven to be the most sensitive imaging modality in the detection of multifocal or multicentric tumor manifestations as well as simultaneous contralateral breast cancer. The aim of the presented retrospective study was to evaluate the benefit of preoperative MRI for patients with breast cancer. Preoperative MRI performed in 121 patients (group A) were compared to 225 patients without preoperative MRI (group B). Patients of group A underwent contrast-enhanced MR imaging of the breast using a 2D FLASH sequence technique (TR/TE/FA 336 ms/5 ms/90°; 32 slices of 4-mm thickness, time of acquisition 1:27 min, contrast agent dosage 0.1 mmol Gd-DTPA/kg bw). All patients had histologically verified breast cancer and follow-up for more than 20 months (mean time group A: 40.3 months, group B: 41 months). Both groups received the same types of systemic treatment after breast conserving surgery. The in-breast tumor recurrence rate in group A was 1/86 (1.2%) compared to 9/133 (6.8%) in group B. Contralateral carcinoma were detected within follow-up in 2/121 (1.7%) in group A vs. 9/225 (4%) in group B. All results were statistically significant (P<0.001). Based on these results, preoperative MRI of the breasts is recommended in patients with histopathologically verified breast cancer for local staging.
- 10 July 2004
- Published by Springer Nature in European Radiology
- Vol. 14 (10) , 1725-1731
The influence of preoperative MRI of the breasts on recurrence rate in patients with breast cancer
Preoperative MRI of the breasts has been proven to be the most sensitive imaging modality in the detection of multifocal or multicentric tumor manifestations as well as simultaneous contralateral breast cancer. The aim of the presented retrospective study was to evaluate the benefit of preoperative MRI for patients with breast cancer. Preoperative MRI performed in 121 patients (group A) were compared to 225 patients without preoperative MRI (group B). Patients of group A underwent contrast-enhanced MR imaging of the breast using a 2D FLASH sequence technique (TR/TE/FA 336 ms/5 ms/90°; 32 slices of 4-mm thickness, time of acquisition 1:27 min, contrast agent dosage 0.1 mmol Gd-DTPA/kg bw). All patients had histologically verified breast cancer and follow-up for more than 20 months (mean time group A: 40.3 months, group B: 41 months). Both groups received the same types of systemic treatment after breast conserving surgery. The in-breast tumor recurrence rate in group A was 1/86 (1.2%) compared to 9/133 (6.8%) in group B. Contralateral carcinoma were detected within follow-up in 2/121 (1.7%) in group A vs. 9/225 (4%) in group B. All results were statistically significant (P<0.001). Based on these results, preoperative MRI of the breasts is recommended in patients with histopathologically verified breast cancer for local staging.
- 1 November 2002
- Published by Springer Nature in European Radiology
- Vol. 12 (11) , 2679-2683
Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography
The goal of this prospective study was to compare a full-field digital mammography system (FFDM) to a conventional screen-film mammography system (SFM) for the detection and characterization of microcalcifications. Fifty-five patients with 57 isolated microcalcification clusters were examined using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, Wis.) and a SFM system (Senographe DMR, GE Medical Systems, Milwaukee, Wis.). A conventional screen-film mammogram and a digital contact mammogram were obtained of each cluster. The image quality and the number of calcification particles were evaluated, and a characterization (BI-RADS 1-5) of microcalcifications was given by four experienced readers. Histopathology revealed 16 benign lesions (sclerosing adenosis, dysplasia, hamartoma, radial scar) in 15 patients and 21 malignant tumors (in situ carcinoma, invasive carcinoma) in 20 patients. Twenty patients had benign changes verified by long-term follow-up. Image quality of FFDM was assessed as superior to SFM in more than 50% of the cases. The FFDM showed more calcifications in 41% of all cases. Sensitivity and specificity for FFDM vs SFM were 95.2 vs 91.9% and 41.4 vs 39.3%, respectively. Moreover, FFDM demonstrated a higher diagnostic accuracy (deviation: 0.86 BI-RADS steps) compared with FSM (deviation 0.93 BI-RADS steps). The FFDM system with a 100- micro m pixel size provides better image quality than SFM in patients with mammographic microcalcifications. The FFDM has a higher sensitivity and a higher reliability in characterizing microcalcifications.
- 1 November 2002
- Published by Springer Nature in European Radiology
- Vol. 12 (11) , 2679-2683
Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography
The goal of this prospective study was to compare a full-field digital mammography system (FFDM) to a conventional screen-film mammography system (SFM) for the detection and characterization of microcalcifications. Fifty-five patients with 57 isolated microcalcification clusters were examined using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, Wis.) and a SFM system (Senographe DMR, GE Medical Systems, Milwaukee, Wis.). A conventional screen-film mammogram and a digital contact mammogram were obtained of each cluster. The image quality and the number of calcification particles were evaluated, and a characterization (BI-RADS 1-5) of microcalcifications was given by four experienced readers. Histopathology revealed 16 benign lesions (sclerosing adenosis, dysplasia, hamartoma, radial scar) in 15 patients and 21 malignant tumors (in situ carcinoma, invasive carcinoma) in 20 patients. Twenty patients had benign changes verified by long-term follow-up. Image quality of FFDM was assessed as superior to SFM in more than 50% of the cases. The FFDM showed more calcifications in 41% of all cases. Sensitivity and specificity for FFDM vs SFM were 95.2 vs 91.9% and 41.4 vs 39.3%, respectively. Moreover, FFDM demonstrated a higher diagnostic accuracy (deviation: 0.86 BI-RADS steps) compared with FSM (deviation 0.93 BI-RADS steps). The FFDM system with a 100- micro m pixel size provides better image quality than SFM in patients with mammographic microcalcifications. The FFDM has a higher sensitivity and a higher reliability in characterizing microcalcifications.
- 1 May 2002
- Published by Springer Nature in Der Radiologe
- Vol. 42 (5) , 361-368
Qualitätsmanagement in einer radiologischen Abteilung
- 1 May 2002
- Published by Springer Nature in Der Radiologe
- Vol. 42 (5) , 361-368
Qualitätsmanagement in einer radiologischen Abteilung
- 30 October 2001
- Published by Springer Nature in European Radiology
- Vol. 12 (2) , 296-303
Preoperative local MRI-staging of patients with a suspected pancreatic mass
The aim of this study was to define the value of MRI of the pancreas for preoperative local staging of patients with a suspected pancreatic mass. Ninety-four patients (41 women, 53 men; age range 32–87 years) with a suspected pancreatic tumor underwent preoperative staging with MRI on a 1.5-T system. The MRI protocol included breath-hold MR cholangiopancreatography in turbo spin-echo technique, biphasic contrast-enhanced 3D MR angiography, and MRI of the upper abdomen with breath-hold T2-weighted half-Fourier acquired single-shot turbo spin-echo and T1-weighted fast-low-angle-shot (pre- and postcontrast) sequences. Data were collected prospectively and analyzed by two radiologists in agreement modality. Evaluation criteria were vascular involvement, resectability, and a characterization benign vs malignant. Results were compared to histopathology in 78 patients. Sixteen patients were followed-up. In 74 of 94 patients a solid tumor or an inflammation of the pancreas (n=62) or the papilla (n=12) was detected. In this group, MRI had a sensitivity of 98%, a specificity of 92%, and an accuracy of 96% in the characterization of malignant tumors. Regarding only the solid tumors, the positive predictive value of MRI was 87% with respect to resectability. Other pathologic findings included adenoma or inflammation of the duodenum (n=5), carcinoma or benign stenosis of the choledochus duct (n=7) and carcinoma of the gall bladder (n=2). In 6 patients MRI did not depict any pathologic findings, and follow-up confirmed this interpretation. Magnetic resonance imaging allows a local preoperative staging in patients with suspected pancreatic tumor. Limitations, however, concern to the diagnostics of peritoneal and/or liver metastases.
- 30 October 2001
- Published by Springer Nature in European Radiology
- Vol. 12 (2) , 296-303
Preoperative local MRI-staging of patients with a suspected pancreatic mass
The aim of this study was to define the value of MRI of the pancreas for preoperative local staging of patients with a suspected pancreatic mass. Ninety-four patients (41 women, 53 men; age range 32–87 years) with a suspected pancreatic tumor underwent preoperative staging with MRI on a 1.5-T system. The MRI protocol included breath-hold MR cholangiopancreatography in turbo spin-echo technique, biphasic contrast-enhanced 3D MR angiography, and MRI of the upper abdomen with breath-hold T2-weighted half-Fourier acquired single-shot turbo spin-echo and T1-weighted fast-low-angle-shot (pre- and postcontrast) sequences. Data were collected prospectively and analyzed by two radiologists in agreement modality. Evaluation criteria were vascular involvement, resectability, and a characterization benign vs malignant. Results were compared to histopathology in 78 patients. Sixteen patients were followed-up. In 74 of 94 patients a solid tumor or an inflammation of the pancreas (n=62) or the papilla (n=12) was detected. In this group, MRI had a sensitivity of 98%, a specificity of 92%, and an accuracy of 96% in the characterization of malignant tumors. Regarding only the solid tumors, the positive predictive value of MRI was 87% with respect to resectability. Other pathologic findings included adenoma or inflammation of the duodenum (n=5), carcinoma or benign stenosis of the choledochus duct (n=7) and carcinoma of the gall bladder (n=2). In 6 patients MRI did not depict any pathologic findings, and follow-up confirmed this interpretation. Magnetic resonance imaging allows a local preoperative staging in patients with suspected pancreatic tumor. Limitations, however, concern to the diagnostics of peritoneal and/or liver metastases.
- 1 January 2001
- Vol. 151, 552-5
[Conventional or digital mammography].
Digital techniques have been applied in many fields of diagnostic radiology, but they were not accepted in mammography. The technological base of direct digital mammography was the development of CCD-chips. Clinical experiences with this system are promising and may lead to replacement of conventional techniques in the future. With intraindividual correlation studies it was shown that microcalcifications were detected better than with conventional techniques. Patients' dose is equal with both system and the reporting time could be reduced. Moreover, digital mammography is important for the use of software programmes of computer assisted diagnosis (CAD).
- 1 January 2001
- Vol. 151, 552-5
[Conventional or digital mammography].
Digital techniques have been applied in many fields of diagnostic radiology, but they were not accepted in mammography. The technological base of direct digital mammography was the development of CCD-chips. Clinical experiences with this system are promising and may lead to replacement of conventional techniques in the future. With intraindividual correlation studies it was shown that microcalcifications were detected better than with conventional techniques. Patients' dose is equal with both system and the reporting time could be reduced. Moreover, digital mammography is important for the use of software programmes of computer assisted diagnosis (CAD).