Henriette Stokbro Jensen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Henriette Stokbro Jensen has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Asbjørn Haaning Nielsen
Department of the Built Environment, Aalborg University, Thomas Manns Vej 23, 9220 Aalborg E, Denmark
3 shared publications - Jes Vollertsen
Aalborg University
3 shared publications - Thorkild Hvitved-Jacobsen
Aalborg University
2 shared publications - Piet Nicolaas Luc Lens
University of Galway
1 shared publication Thorkild Hvitved‐Jacobsen
Section of Environmental Engineering, Department of Biotechnology, Chemistry and Environmental Engineering, Aalborg University, Aalborg, Denmark
1 shared publication
Latest Publications
- 15 October 2009
- Published by Taylor & Francis in Environmental Technology
- Vol. 30 (12) , 1291-1296
Hydrogen sulphide removal from corroding concrete: Comparison between surface removal rates and biomass activity
Corrosion of concrete sewer pipes caused by hydrogen sulphide is a problem in many sewer networks. The mechanisms of production and fate of hydrogen sulphide in the sewer biofilms and wastewater as well as its release to the sewer atmosphere are largely understood. In contrast, the mechanisms of the uptake of hydrogen sulphide on the concrete surfaces and subsequent concrete corrosion are basically unknown. To shed light on these mechanisms, the uptake of hydrogen sulphide from a sewer gas phase was compared to the biological hydrogen sulphide removal potential of the concrete corrosion products. The results showed that both microbial degradation at and sorption to the concrete surfaces were important for the uptake of hydrogen sulphide on the concrete surfaces.
- 15 October 2009
- Published by Taylor & Francis in Environmental Technology
- Vol. 30 (12) , 1291-1296
Hydrogen sulphide removal from corroding concrete: Comparison between surface removal rates and biomass activity
Corrosion of concrete sewer pipes caused by hydrogen sulphide is a problem in many sewer networks. The mechanisms of production and fate of hydrogen sulphide in the sewer biofilms and wastewater as well as its release to the sewer atmosphere are largely understood. In contrast, the mechanisms of the uptake of hydrogen sulphide on the concrete surfaces and subsequent concrete corrosion are basically unknown. To shed light on these mechanisms, the uptake of hydrogen sulphide from a sewer gas phase was compared to the biological hydrogen sulphide removal potential of the concrete corrosion products. The results showed that both microbial degradation at and sorption to the concrete surfaces were important for the uptake of hydrogen sulphide on the concrete surfaces.
- 1 April 2009
- Published by Wiley in Water Environment Research
- Vol. 81 (4) , 365-373
Modeling of Hydrogen Sulfide Oxidation in Concrete Corrosion Products from Sewer Pipes
Abiotic and biotic oxidation of hydrogen sulfide related to concrete corrosion was studied in corrosion products originating from a sewer manhole. The concrete corrosion products were suspended in an acidic solution, mimicking the conditions in the pore water of corroded concrete. The removal of hydrogen sulfide and dissolved oxygen was measured in parallel in the suspension, upon which the suspension was sterilized and the measurement repeated. The results revealed the biotic oxidation to be fast compared with the abiotic oxidation. The stoichiometry of the hydrogen sulfide oxidation was evaluated using the ratio between oxygen and hydrogen sulfide uptake. The ratio for the biotic oxidation pointed in the direction of elemental sulfur being formed as an intermediate in the oxidation of hydrogen sulfide to sulfuric acid. The experimental results were applied to suggest a hypothesis and a mathematical model describing the hydrogen sulfide oxidation pathway in a matrix of corroded concrete.
- 1 April 2009
- Published by Wiley in Water Environment Research
- Vol. 81 (4) , 365-373
Modeling of Hydrogen Sulfide Oxidation in Concrete Corrosion Products from Sewer Pipes
Abiotic and biotic oxidation of hydrogen sulfide related to concrete corrosion was studied in corrosion products originating from a sewer manhole. The concrete corrosion products were suspended in an acidic solution, mimicking the conditions in the pore water of corroded concrete. The removal of hydrogen sulfide and dissolved oxygen was measured in parallel in the suspension, upon which the suspension was sterilized and the measurement repeated. The results revealed the biotic oxidation to be fast compared with the abiotic oxidation. The stoichiometry of the hydrogen sulfide oxidation was evaluated using the ratio between oxygen and hydrogen sulfide uptake. The ratio for the biotic oxidation pointed in the direction of elemental sulfur being formed as an intermediate in the oxidation of hydrogen sulfide to sulfuric acid. The experimental results were applied to suggest a hypothesis and a mathematical model describing the hydrogen sulfide oxidation pathway in a matrix of corroded concrete.
- 1 June 2008
- Published by IWA Publishing in Water Science & Technology
- Vol. 57 (11) , 1721-1726
Survival of hydrogen sulfide oxidizing bacteria on corroded concrete surfaces of sewer systems
The activity of hydrogen sulfide oxidizing bacteria within corroded concrete from a sewer manhole was investigated. The bacteria were exposed to hydrogen sulfide starvation for up till 18 months, upon which their hydrogen sulfide oxidizing activity was measured. It was tested whether the observed reduction in biological activity was caused by a biological lag phase or by decay of the bacteria. The results showed that the bacterial activity declined with approximately 40% pr. month during the first two months of hydrogen sulfide starvation. After 2–3 months of starvation, the activity stabilized. Even after 6 months of starvation, exposure to hydrogen sulfide for 6 hours a day on three successive days could restore the bacteriological activity to about 80% of the initial activity. After 12 months of starvation, the activity could, however, not be restored, and after 18 months the biological activity approached zero. The long-term survival aspect of concrete corroding bacteria has implications for predicting hydrogen sulfide corrosion in sewer systems subject to irregular hydrogen sulfide loadings, e.g. as they occur in temperate climates where hydrogen sulfide often is a summer-problem only.
- 1 June 2008
- Published by IWA Publishing in Water Science & Technology
- Vol. 57 (11) , 1721-1726
Survival of hydrogen sulfide oxidizing bacteria on corroded concrete surfaces of sewer systems
The activity of hydrogen sulfide oxidizing bacteria within corroded concrete from a sewer manhole was investigated. The bacteria were exposed to hydrogen sulfide starvation for up till 18 months, upon which their hydrogen sulfide oxidizing activity was measured. It was tested whether the observed reduction in biological activity was caused by a biological lag phase or by decay of the bacteria. The results showed that the bacterial activity declined with approximately 40% pr. month during the first two months of hydrogen sulfide starvation. After 2–3 months of starvation, the activity stabilized. Even after 6 months of starvation, exposure to hydrogen sulfide for 6 hours a day on three successive days could restore the bacteriological activity to about 80% of the initial activity. After 12 months of starvation, the activity could, however, not be restored, and after 18 months the biological activity approached zero. The long-term survival aspect of concrete corroding bacteria has implications for predicting hydrogen sulfide corrosion in sewer systems subject to irregular hydrogen sulfide loadings, e.g. as they occur in temperate climates where hydrogen sulfide often is a summer-problem only.