David J. Hart
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David J. Hart has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- James M. Tinjum
University of Wisconsin-Madison, Department of Civil and Environmental Engineering, 53705 Madison, WI, USA
4 shared publications Daniel T. Feinstein
2 shared publications- Dante Fratta
University of Wisconsin-Madison
2 shared publications K.R. Bradbury
Wisconsin Geological and Natural History Survey, 3817 Mineral Port Rd., Madison, WI 53705
2 shared publications- Adam McDaniel
Univ. of Wisconsin-Madison
1 shared publication - Ayse Ozdogan Dolcek
University of Wisconsin-Madison, Department of Civil & Environmental Engineering, 1415 Engineering Drive, Madison, WI 53706, USA
1 shared publication
Latest Publications
- 8 August 2016
- Published by American Society of Civil Engineers (ASCE)
- p. 1-11
Dynamic Calibration of a Fiber-Optic Distributed Temperature Sensing Network at a District-Scale Geothermal Exchange Borefield
Subsurface heat exchange research in a low-temperature district-scale geothermal borefield is a demanding application for fiber-optic distributed temperature sensing (DTS). While DTS systems do provide internal calibration routines, external calibration schemes are often needed to achieve desired accuracy and precision. This study systematically documents a set of tests aimed at evaluating the efficacy of both internal and external calibration routines and selects the most appropriate external calibration technique for a geothermal borefield monitoring study. The selection of this calibration scheme is based on the inability of static DTS calibration to prevent measurement drift and the physical requirement of sophisticated cable networks and splices at the district-scale field site. A double-ended and dynamic calibration with centralized and remotely accessible data collection and processing is developed to prevent measurement drift and to solve differential attenuation challenges. The calibration is primarily achieved by two long-term calibration baths that keep reference sections of each fiber-optic cable at continuously known temperatures. After calibration, temperature profiles from fiber-optic cables placed within ground heat exchangers (GHX) and sentry boreholes provide valuable knowledge of subsurface heat flow which assists in detection of borefield overheating, comparison of individual GHX performance, and design optimization of future borefields.
- 8 August 2016
- Published by American Society of Civil Engineers (ASCE)
- p. 1-11
Dynamic Calibration of a Fiber-Optic Distributed Temperature Sensing Network at a District-Scale Geothermal Exchange Borefield
Subsurface heat exchange research in a low-temperature district-scale geothermal borefield is a demanding application for fiber-optic distributed temperature sensing (DTS). While DTS systems do provide internal calibration routines, external calibration schemes are often needed to achieve desired accuracy and precision. This study systematically documents a set of tests aimed at evaluating the efficacy of both internal and external calibration routines and selects the most appropriate external calibration technique for a geothermal borefield monitoring study. The selection of this calibration scheme is based on the inability of static DTS calibration to prevent measurement drift and the physical requirement of sophisticated cable networks and splices at the district-scale field site. A double-ended and dynamic calibration with centralized and remotely accessible data collection and processing is developed to prevent measurement drift and to solve differential attenuation challenges. The calibration is primarily achieved by two long-term calibration baths that keep reference sections of each fiber-optic cable at continuously known temperatures. After calibration, temperature profiles from fiber-optic cables placed within ground heat exchangers (GHX) and sentry boreholes provide valuable knowledge of subsurface heat flow which assists in detection of borefield overheating, comparison of individual GHX performance, and design optimization of future borefields.
- 26 September 2015
- Published by Springer Nature in Hydrogeology Journal
- Vol. 24 (1) , 21-33
A comparison of fracture transmissivities in granite water wells before and after hydrofracturing
- 26 September 2015
- Published by Springer Nature in Hydrogeology Journal
- Vol. 24 (1) , 21-33
A comparison of fracture transmissivities in granite water wells before and after hydrofracturing
- 2 March 2015
- Published by Wiley in Groundwater
- Vol. 54 (1) , 126-130
New Ways of Using Well Construction Reports for Hydrostratigraphic Analyses
Hydrostratigraphic models require subsurface data. Those data can be gleaned from Well Construction Reports ( WCRs ) if the reports are properly reviewed and processed. In the United States, WCRs or similar documents are generally required to be submitted to a state agency. The quality of those reports varies considerably and depends on the water well contractor's level of geologic knowledge. Nevertheless, these types of reports are usually the largest available subsurface data set. We present two examples from Wisconsin, each of which had approximately 2000 WCRs , to demonstrate a variety of new applications of WCRs including obtaining information about the depositional environment; selecting sites to perform surface geophysical measurements; and creating three‐dimensional hydrostratigraphic models for groundwater modeling.
- 2 March 2015
- Published by Wiley in Groundwater
- Vol. 54 (1) , 126-130
New Ways of Using Well Construction Reports for Hydrostratigraphic Analyses
Hydrostratigraphic models require subsurface data. Those data can be gleaned from Well Construction Reports ( WCRs ) if the reports are properly reviewed and processed. In the United States, WCRs or similar documents are generally required to be submitted to a state agency. The quality of those reports varies considerably and depends on the water well contractor's level of geologic knowledge. Nevertheless, these types of reports are usually the largest available subsurface data set. We present two examples from Wisconsin, each of which had approximately 2000 WCRs , to demonstrate a variety of new applications of WCRs including obtaining information about the depositional environment; selecting sites to perform surface geophysical measurements; and creating three‐dimensional hydrostratigraphic models for groundwater modeling.
- 1 February 2015
- Published by Springer Nature in Geotechnical and Geological Engineering
- Vol. 33 (2) , 223-238
Thermal Property Measurements of Stratigraphic Units with Modeled Implications for Expected Performance of Vertical Ground Source Heat Pumps
- 1 February 2015
- Published by Springer Nature in Geotechnical and Geological Engineering
- Vol. 33 (2) , 223-238
Thermal Property Measurements of Stratigraphic Units with Modeled Implications for Expected Performance of Vertical Ground Source Heat Pumps
- 24 February 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 2755-2766
Numerical Modeling of Ground Temperature Response in a Ground-Source Heat Pump System (GSHP)
Ground-source heat pump (GSHP) systems use the ground as an energy reservoir and can be installed nearly everywhere, even in areas of low geothermal gradient to provide an environmental friendly, low-cost, and sustainable energy source for space heating and cooling. This study describes the long-term, cumulative thermal response of the ground around a vertical ground heat exchanger (GHE) operating in both heating and cooling modes, with the dominant GSHP mode being cooling. An actual 300-m deep borehole through varying lithology has been modeled with fully three-dimensional finite element analysis using ABAQUS software. The monthly average surface temperature and temperature at depth were used as boundary conditions, and the monthly heating and cooling loads were applied as constant heat load with depth along the borehole. The modeling results shows that a deep GHE system may be more efficient by taking advantage of the geothermal gradient and is less sensitive to seasonal impacts than shallow GHE systems. Based on the modeling results, the temperature profiles along the borehole and near surface are not constant and vary significantly when the lithology changes. Therefore, the actual thermal conductivity values for each geological material should be considered.
- 24 February 2014
- Published by American Society of Civil Engineers (ASCE)
- p. 2755-2766
Numerical Modeling of Ground Temperature Response in a Ground-Source Heat Pump System (GSHP)
Ground-source heat pump (GSHP) systems use the ground as an energy reservoir and can be installed nearly everywhere, even in areas of low geothermal gradient to provide an environmental friendly, low-cost, and sustainable energy source for space heating and cooling. This study describes the long-term, cumulative thermal response of the ground around a vertical ground heat exchanger (GHE) operating in both heating and cooling modes, with the dominant GSHP mode being cooling. An actual 300-m deep borehole through varying lithology has been modeled with fully three-dimensional finite element analysis using ABAQUS software. The monthly average surface temperature and temperature at depth were used as boundary conditions, and the monthly heating and cooling loads were applied as constant heat load with depth along the borehole. The modeling results shows that a deep GHE system may be more efficient by taking advantage of the geothermal gradient and is less sensitive to seasonal impacts than shallow GHE systems. Based on the modeling results, the temperature profiles along the borehole and near surface are not constant and vary significantly when the lithology changes. Therefore, the actual thermal conductivity values for each geological material should be considered.
- 23 December 2009
- Published by Wiley in Groundwater
- Vol. 48 (1) , 14-15
A uthor's R eply
- 4 July 2008
- Published by Wiley in Groundwater
- Vol. 46 (4) , 518-520
Is One an Upper Limit for Natural Hydraulic Gradients?
- 4 July 2008
- Published by Wiley in Groundwater
- Vol. 46 (4) , 518-520
Is One an Upper Limit for Natural Hydraulic Gradients?
- 9 November 2005
- Published by Wiley in Groundwater
- Vol. 44 (2) , 201-211
The Vertical Hydraulic Conductivity of an Aquitard at Two Spatial Scales
Aquitards protect underlying aquifers from contaminants and limit recharge to those aquifers. Understanding the mechanisms and quantity of ground water flow across aquitards to underlying aquifers is essential for ground water planning and assessment. We present results of laboratory testing for shale hydraulic conductivities, a methodology for determining the vertical hydraulic conductivity ( K v ) of aquitards at regional scales and demonstrate the importance of discrete flow pathways across aquitards. A regional shale aquitard in southeastern Wisconsin, the Maquoketa Formation, was studied to define the role that an aquitard plays in a regional ground water flow system. Calibration of a regional ground water flow model for southeastern Wisconsin using both predevelopment steady‐state and transient targets suggested that the regional K v of the Maquoketa Formation is 1.8 × 10 −11 m/s. The core‐scale measurements of the K v of the Maquoketa Formation range from 1.8 × 10 −14 to 4.1 × 10 −12 m/s. Flow through some additional pathways in the shale, potential fractures or open boreholes, can explain the apparent increase of the regional‐scale K v . Based on well logs, erosional windows or high‐conductivity zones seem unlikely pathways. Fractures cutting through the entire thickness of the shale spaced 5 km apart with an aperture of 50 microns could provide enough flow across the aquitard to match that provided by an equivalent bulk K v of 1.8 × 10 −11 m/s. In a similar fashion, only 50 wells of 0.1 m radius open to aquifers above and below the shale and evenly spaced 10 km apart across southeastern Wisconsin can match the model K v .
- 9 November 2005
- Published by Wiley in Groundwater
- Vol. 44 (2) , 201-211
The Vertical Hydraulic Conductivity of an Aquitard at Two Spatial Scales
Aquitards protect underlying aquifers from contaminants and limit recharge to those aquifers. Understanding the mechanisms and quantity of ground water flow across aquitards to underlying aquifers is essential for ground water planning and assessment. We present results of laboratory testing for shale hydraulic conductivities, a methodology for determining the vertical hydraulic conductivity ( K v ) of aquitards at regional scales and demonstrate the importance of discrete flow pathways across aquitards. A regional shale aquitard in southeastern Wisconsin, the Maquoketa Formation, was studied to define the role that an aquitard plays in a regional ground water flow system. Calibration of a regional ground water flow model for southeastern Wisconsin using both predevelopment steady‐state and transient targets suggested that the regional K v of the Maquoketa Formation is 1.8 × 10 −11 m/s. The core‐scale measurements of the K v of the Maquoketa Formation range from 1.8 × 10 −14 to 4.1 × 10 −12 m/s. Flow through some additional pathways in the shale, potential fractures or open boreholes, can explain the apparent increase of the regional‐scale K v . Based on well logs, erosional windows or high‐conductivity zones seem unlikely pathways. Fractures cutting through the entire thickness of the shale spaced 5 km apart with an aperture of 50 microns could provide enough flow across the aquitard to match that provided by an equivalent bulk K v of 1.8 × 10 −11 m/s. In a similar fashion, only 50 wells of 0.1 m radius open to aquifers above and below the shale and evenly spaced 10 km apart across southeastern Wisconsin can match the model K v .