GCG. Moeller Chávez

G. Moeller Chávez

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


G. Moeller Chávez has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Petia Mijaylova Nacheva

    Instituto Mexicano de Tecnología del Agua, Postgrado en Ingeniería Ambiental de la UNAM-Campus IMTA, Blvd. Paseo Cuauhnahuac 8532, Progreso, 62550 Jiutepec, Mor., México

    4 shared publications
  • A. Canul Chuil

    National University of Mexico, Ciudad Universitaria, Coyoacan México D.F. 04510, México

    1 shared publication
  • A. Rivas-Hernández

    Wastewater Treatment Department. Mexican Institute of Water Technology. Paseo Cuauhnahuac 8532, Jiutepec, Morelos-Mexico.62550

    1 shared publication
  • C. Bustos

    National University of Mexico, Ciudad Universitaria, Coyoacan, México D.F. 04510 México

    1 shared publication
  • F. Pozo-Román

    Wastewater Treatment Department. Mexican Institute of Water Technology. Paseo Cuauhnahuac 8532, Jiutepec, Morelos-Mexico.62550

    1 shared publication
  • H. Guerrero-García-Rojas

    Université de Sciences Sociales I, Manufacture des Tabac – Bât. F, 21 allée de Brienne, F-31000 Toulouse, – France

    1 shared publication

Latest Publications

  • Wastewater treatment using a novel bioreactor with submerged packing bed of polyethylene tape

    by P. Mijaylova Nacheva, G. Moeller Chávez

    The performance of a novel aerobic bioreactor with a specially designed submerged packing bed of high specific surface area density, made of polyethylene tape, was studied for the treatment of domestic wastewater. The reactor has a volume of 0.71 m(3) and the specific area of the packing bed was 1,098 m(2)/m(3). The operation was performed with and without effluent recycling, applying different organic loads in the range of 4.0-17.6 g COD m(-2) d(-1). No back-washings were carried out. Overall BOD(5) removals of 90-95% were obtained with organic loads of 4.0-17.6 g COD m(-2) d(-1) and HRT of 0.2-1.1 h. Overall TN removal of 69-72% was obtained at loads of 0.8-4.6 g TN m(-2) d(-1) when effluent recycling was used. The reactor allowed obtaining high quality water for urban reuse and demonstrated an effective process performance and resistance to load variations. The developed biofilm was completely penetrated by the organic matter, ammonia and oxygen, providing high removal rates. Large biomass quantities, up to 13 g dry VS/m(2), were reached in the reactor and the determined sludge yield coefficient was relatively low, of 0.25 g VSS/g COD. These results allow obtaining compact treatment systems with low sludge production and make the technology a suitable option for small wastewater treatment plants.


  • Treatment of cane sugar mill wastewater in an upflow anaerobic sludge bed reactor

    by P. Mijaylova Nacheva, G. Moeller Chávez, J. Matías Chacón, A. Canul Chuil

    The performance of a mesophilic UASB reactor was studied for the treatment of sugar cane mill wastewater previously pre-treated for solid separation. The experimental work was carried out in a reactor with 80 L total volume. Four organic loads were applied and the process performance was evaluated during two months for each experimental stage. Removal efficiencies higher than 90% were obtained with organic loads up to 16 kg COD m−3 d−1. Stable process performance and high biogas production were obtained. The COD removal rate increased substantially with the load increase to 24 kg COD m−3 d−1. However, the obtained removal was of only 78–82%, which can be attributed to the accumulation of volatile organic acids. The kinetic coefficients were obtained using first order model for the substrate removal rate and Monod's equation for bacteria specific growth rate. The UASB reactor is a good option for the biological treatment of pre-treated sugar cane mill wastewaters. The discharge requirements for COD concentration can be accomplished if the reactor is operated at a low organic load of 4 kg COD m−3 d−1. At higher loads, an additional biological treatment stage is needed.


  • Comparison of bioreactors with different kinds of submerged packed beds for domestic wastewater treatment

    by P. Mijaylova Nacheva, G. Moeller Chávez, M. A. Garzón Zúñiga, C. Bustos, Y. Hornelas Orozco

    Polyethylene (HDPE), of low density polyethylene (LDPE) and of polypropylene (PP), cubes of polyurethane (PU) and polyethylene tape (SESSIL). The bioreactors were operated in continuous regime, applying organic loads in the range of 0.8-6.0 g COD.m22.d21. The obtained specific COD removal rates were very similar in all the reactors when they were operated at organic loads up to 2.0 g COD.m22.d21, after which differences in effectiveness appeared and the best results were determined in the reactors with SESSIL, LDPE and PU. Very low TSS, O&G and turbidity were obtained in all the effluents. The NH3ZN and TN removals were dependant on the dissolved oxygen (DO) concentration and the removals at DO of 5 mg/l were 84-99% and 61-74% respectively. The best removals were determined in the reactors with PU, SESSIL and LDPE. The reactor with tezontle had also a good performance when operated with loads up to 1.0 g TN.m22.d21. The best phosphate removals (38-49%) were obtained in the reactors with PU, tezontle, ceramic sheres and SESSIL.


  • Price for water reclamation, how can it be established? A Mexican case study

    by L. Seguí-Amórtegui, O. Alfranca-Burriel, H. Guerrero-García-Rojas, G. Moeller-Chávez

    This study presents the results of an evaluation which provides the necessary decision making tools before to put into operation a System of Reclamation and Reuse Wastewater (SRRWW), in the way to assure the economic viability of the project. This system contributes to improve the sanitary conditions in Jiutepec, Mexico. The applied methodology considers the identification, quantification and economical evaluation of different impacts, private and external, selecting the alternatives that maximize the total benefit. The alternative of the industrial park of CIVAC is the most profitable for the reuse with a maximum benefit of 0.4591 USD/m3. With the idea of recovering all the SRRWW costs, the minimum price of sale of the regenerated water should be 0.2751 USD/m3. Even though all the impacts were not economically evaluated, it does not affect the result on investment decision, since the impacts without evaluating only will increase the benefits of the selected systems.


  • Water reuse in the Apatlaco River Basin (México): a feasibility study

    by G. Moeller-Chavez, L. Seguí-Amórtegui, O. Alfranca-Burriel, V. Escalante-Estrada, F. Pozo-Román, A. Rivas-Hernández

    The aim of this work is to determine the technical and economic feasibility of implementing different reclamation and reuse projects that improve the quality of the Apatlaco river basin located in the central part of Mexico. A special methodology based on a decision support system was developed. This methodology allows to decide if it is convenient or not to finance a reclamation or reuse project for the most common water uses in the basin. This methodology is based on the net present value criteria (NPV) of the effective cash flow during the useful life of the project. The results obtained reveal a technical and economical feasibility for industrial reuse in Jiutepec and for agricultural reuse in Zacatepec and Emiliano Zapata. On the other hand, sanitation projects are not feasible in all cases analyzed. Therefore, Mexican Regulation (Ley Federal de Derechos en Materia de Agua) as currently implemented, does not promote and support this kind of projects.


  • Alternative treatment strategy for tannery water reuse and material recovery

    by P. Mijaylova Nacheva, G. Moeller Chávez, M. Juárez Herrera

    Most tanneries use conventional systems for treatment of the mixture of all production effluents. Such an approach makes it possible to meet environmental regulations, but because of the high cost of the treatment facilities, its implementation has been scarce, especially in developing countries. With the waste reduction-elimination concept in view, an alternative strategy for water management is proposed based on individual treatment of the effluents from different processing steps to obtain multiquality recycled water for various reuse purposes, materials recovery and complete reuse of treated water. The methodology includes a database generation of tanneries in Mexico, a mass balance and pollution index determination, formulation of water management scenarios and technical-economical evaluation. To replace the traditionally used sulfide oxidation, a sulfide recovering was proposed. Chromium, grease and protein recovery were considered too. The proposed alternative allows a 90% fresh water reduction, the recovery of more than 95% of chromium and sulfide, 90% of grease, 65% of protein and zero discharge of wastewater. Simultaneous implementation of various water saving methods using in-house wastewater treatment techniques for recovering of chemicals and sub-products reduces substantially the cost of water management.


  • Two combined techniques to enhance anaerobic digestion of sludge

    by G. Moeller-Chávez, S. González-Martínez

    The rate-limiting step during anaerobic digestion is the hydrolysis of the particulate organic matter and methanogenesis. Certain elements, such as iron, nickel and cobalt and some growth factors such as coenzymes are needed for the adequate growth of the organisms. The main objective of this research was to enhance anaerobic digestion of primary sludge combining thermal and alkaline pre-treatment with stimulation of the methanogenic activity by adding yeast extract. Primary sludge was exposed, separately, to alkaline and thermal pre-treatment procedures. After this pre-treatment, different amounts of yeast extract were added to the sludge. The best COD, TSS and VSS removal rates were observed without pre-treatment and with the addition of 0.1% in weight of yeast extract. The highest specific methane production was obtained with thermal pre-treatment and 0.1% yeast addition. A second experimental stage was run for a closer analysis of the preliminary results. Thermal pre-treatment and 0.1% yeast addition was tested. The best results regarding both COD, TSS and VSS removal rates and methane production were obtained without thermal pre-treatment and with addition of yeast extract. The calculated F-values for the ANOVA-test show that the main influencing factor was the addition of yeast extract where the Biochemical Methane Production was doubled compared with the blank. The highest values for the hydrolysis constants were obtained at hydraulic retention times of six days after adding 0.1% of yeast extract.