Gernot Peter Tilz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gernot Peter Tilz has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Ulrike Demel
Graz University Medical School and Hospital
4 shared publications- Zeno Földes-Papp
Asklepios GmbH, Germany
4 shared publications Wolfgang Domej
Department of Internal Medicine, Graz University M. S. and Hospital, Graz, Austria
2 shared publicationsEckhard Birch-Hirschfeld
Jena University Medical School
1 shared publicationGuïnther Schwaberger
1 shared publicationHerwig Holzer
Department of Internal Medicine, Graz University M.S. and Hospital, A-8036 Graz, LKH, Austria
1 shared publication
Latest Publications
- 1 June 2003
- Published by Springer Nature in Molecular Diagnosis
- Vol. 7 (2) , 99-111
C677T Single Nucleotide Polymorphisms of the Human Methylene Tetrahydrofolate Reductase and Specific Identification
Background: A methylene tetrahydrofolate reductase (MTHFR) deficiency at site C677T renders the enzyme thermolabile and consequently represents a risk factor for vascular disease, neural tube defects, preeclampsia, and thrombosis. Highly specific identification techniques for genotyping are mandatory to give guidance for the diagnosis and monitoring of this deficiency. Methods: A new approach for performing genotyping has been introduced with the identification of single nucleotide polymorphisms of the human MTHFR. It is based on PCR followed by two-color cross-correlation fluorescence spectroscopy (FCS). Experiments were carried out with green- and red-tagged allele-specific primers, which were fully compatible with the two-color fluorescence cross-correlation setup at 488nm and 633nm excitation wavelengths. Results: The measured data of the amplification mixes (tubes) were normalized as the maximum correlation amplitude of each tube. Correlated and uncorrelated data were optically separated in the amplification mixes by their characteristic correlation times, which significantly differed from each other. The correlated data were generated in the presence of the proper mutated genotype template, whereas uncorrelated data were due to the absence of the proper genotype template. Furthermore, the specific association of the two-color fluorescence correlated signals with the target DNA was experimentally proven. Using this novel two-color cross-correlation approach, the MTHFR genotypes, which were determined in 21 clinical samples, showed concordance with methods involving a PCR-based assay with hexachloro-6-carboxy-fluorescein (HEX)- and 6-carboxy-fluorescein (FAM)-tagged allele-specific primers and a subsequent separation step with capillary electrophoresis, yet are simpler to perform. There was no evidence of a central trend of false-positive or false-negative results. We demonstrated how the novel, ultrasensitive typing system could be applied to studies where researchers are trying to perfect their assays and are often working with the unknown, or application to problematic assays in a clinical environment for those involved in molecular diagnosis. Conclusions: We present an alternative method to those commonly used in genotyping. Two-color cross-correlation FCS allows the detection of the fluorescence signals specifically associated with the heterozygous mutated, the homozygous mutated, and normal individuals, as exemplified in this study. The presence of nonspecific amplification products, which interfere with subsequent DNA analysis, could therefore highlight the need for two-color cross-correlation FCS as a means of discriminating between specific association of the fluorescence signals with the target DNA and DNA not related to the target.
- 1 June 2003
- Published by Springer Nature in Molecular Diagnosis
- Vol. 7 (2) , 99-111
C677T Single Nucleotide Polymorphisms of the Human Methylene Tetrahydrofolate Reductase and Specific Identification
Background: A methylene tetrahydrofolate reductase (MTHFR) deficiency at site C677T renders the enzyme thermolabile and consequently represents a risk factor for vascular disease, neural tube defects, preeclampsia, and thrombosis. Highly specific identification techniques for genotyping are mandatory to give guidance for the diagnosis and monitoring of this deficiency. Methods: A new approach for performing genotyping has been introduced with the identification of single nucleotide polymorphisms of the human MTHFR. It is based on PCR followed by two-color cross-correlation fluorescence spectroscopy (FCS). Experiments were carried out with green- and red-tagged allele-specific primers, which were fully compatible with the two-color fluorescence cross-correlation setup at 488nm and 633nm excitation wavelengths. Results: The measured data of the amplification mixes (tubes) were normalized as the maximum correlation amplitude of each tube. Correlated and uncorrelated data were optically separated in the amplification mixes by their characteristic correlation times, which significantly differed from each other. The correlated data were generated in the presence of the proper mutated genotype template, whereas uncorrelated data were due to the absence of the proper genotype template. Furthermore, the specific association of the two-color fluorescence correlated signals with the target DNA was experimentally proven. Using this novel two-color cross-correlation approach, the MTHFR genotypes, which were determined in 21 clinical samples, showed concordance with methods involving a PCR-based assay with hexachloro-6-carboxy-fluorescein (HEX)- and 6-carboxy-fluorescein (FAM)-tagged allele-specific primers and a subsequent separation step with capillary electrophoresis, yet are simpler to perform. There was no evidence of a central trend of false-positive or false-negative results. We demonstrated how the novel, ultrasensitive typing system could be applied to studies where researchers are trying to perfect their assays and are often working with the unknown, or application to problematic assays in a clinical environment for those involved in molecular diagnosis. Conclusions: We present an alternative method to those commonly used in genotyping. Two-color cross-correlation FCS allows the detection of the fluorescence signals specifically associated with the heterozygous mutated, the homozygous mutated, and normal individuals, as exemplified in this study. The presence of nonspecific amplification products, which interfere with subsequent DNA analysis, could therefore highlight the need for two-color cross-correlation FCS as a means of discriminating between specific association of the fluorescence signals with the target DNA and DNA not related to the target.
- 14 February 2002
- Published by Portland Press Ltd. in Clinical Science
- Vol. 102 (3) , 373-380
Cystatin C of pleural effusion as a novel diagnostic aid in pleural diseases of different aetiologies
There has been considerable recent interest in the potential use of serum cystatin C as a diagnostic tool. Here we examined the hypothesis that the cystatin C level in the pleural effusion can differ from the corresponding serum level. We evacuated pleural effusion fluids from 47 patients by thoracentesis. Cystatin C, β2-microglobulin, inorganic phosphate, creatinine and total protein were quantified in both pleural effusion fluids and corresponding sera. We determined cystatin C levels in pleural effusions and calculated the ratio of cystatin C levels in serum and effusion, to discriminate between effusions caused by severe renal impairment and other types of effusion. Extremely high concentrations of cystatin C in serum/effusion pairs were only measured in patients with renal failure (6.0±0.8/6.0±0.8mg/l, means±S.D., n = 11). A clearly defined region was found to correspond to pleural effusion caused by renal failure (r = 0.954). The quantification of cystatin C in the effusion was justified by the discovery that there were some patients with a high serum cystatin C level but a low effusion concentration, or a low serum cystatin C but a high effusion concentration, indicating causes other than renal failure. In conclusion, the pilot data indicate a relationship between the cystatin C concentration in pleural fluid and the underlying disease. Thus cystatin C levels in pleural effusion and serum may be a valuable criterion for the differential diagnosis of pleural diseases of different aetiologies.
- 14 February 2002
- Published by Portland Press Ltd. in Clinical Science
- Vol. 102 (3) , 373-380
Cystatin C of pleural effusion as a novel diagnostic aid in pleural diseases of different aetiologies
There has been considerable recent interest in the potential use of serum cystatin C as a diagnostic tool. Here we examined the hypothesis that the cystatin C level in the pleural effusion can differ from the corresponding serum level. We evacuated pleural effusion fluids from 47 patients by thoracentesis. Cystatin C, β2-microglobulin, inorganic phosphate, creatinine and total protein were quantified in both pleural effusion fluids and corresponding sera. We determined cystatin C levels in pleural effusions and calculated the ratio of cystatin C levels in serum and effusion, to discriminate between effusions caused by severe renal impairment and other types of effusion. Extremely high concentrations of cystatin C in serum/effusion pairs were only measured in patients with renal failure (6.0±0.8/6.0±0.8mg/l, means±S.D., n = 11). A clearly defined region was found to correspond to pleural effusion caused by renal failure (r = 0.954). The quantification of cystatin C in the effusion was justified by the discovery that there were some patients with a high serum cystatin C level but a low effusion concentration, or a low serum cystatin C but a high effusion concentration, indicating causes other than renal failure. In conclusion, the pilot data indicate a relationship between the cystatin C concentration in pleural fluid and the underlying disease. Thus cystatin C levels in pleural effusion and serum may be a valuable criterion for the differential diagnosis of pleural diseases of different aetiologies.
- 25 September 2001
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 98 (20) , 11509-11514
Ultrasensitive detection and identification of fluorescent molecules by FCS: Impact for immunobiology
An experimental application of fluorescence correlation spectroscopy is presented for the detection and identification of fluorophores and auto-Abs in solution. The recording time is between 2 and 60 sec. Because the actual number of molecules in the unit volume (confocal detection volume of about 1 fl) is integer or zero, the fluorescence generated by the molecules is discontinuous when single-molecule sensitivity is achieved. We first show that the observable probability, N , to find a single fluorescent molecule in the very tiny space element of the unit volume is Poisson-distributed below a critical bulk concentration c*. The measured probability means we have traced, for example, 5 × 10 10 fluorophore molecules per ml of bulk solution. The probability is related to the average frequency, C , that the volume of detection contains a single fluorescent molecule and to the concentration, c , of the bulk solution. The analytical sensitivity of an assay is calculated from the average frequency C . In the Goodpasture experiment, we determined as analytical sensitivity a probability of 99.1% of identifying one single immune complex. Under these conditions, a single molecule event is proven. There exist no instrumental assumptions of our approach on which the experiment itself, the theoretical background, or the conclusion are based. Our results open up a broad field for analytics and diagnostics in solution, especially in immunology.
- 25 September 2001
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 98 (20) , 11509-11514
Ultrasensitive detection and identification of fluorescent molecules by FCS: Impact for immunobiology
An experimental application of fluorescence correlation spectroscopy is presented for the detection and identification of fluorophores and auto-Abs in solution. The recording time is between 2 and 60 sec. Because the actual number of molecules in the unit volume (confocal detection volume of about 1 fl) is integer or zero, the fluorescence generated by the molecules is discontinuous when single-molecule sensitivity is achieved. We first show that the observable probability, N , to find a single fluorescent molecule in the very tiny space element of the unit volume is Poisson-distributed below a critical bulk concentration c*. The measured probability means we have traced, for example, 5 × 10 10 fluorophore molecules per ml of bulk solution. The probability is related to the average frequency, C , that the volume of detection contains a single fluorescent molecule and to the concentration, c , of the bulk solution. The analytical sensitivity of an assay is calculated from the average frequency C . In the Goodpasture experiment, we determined as analytical sensitivity a probability of 99.1% of identifying one single immune complex. Under these conditions, a single molecule event is proven. There exist no instrumental assumptions of our approach on which the experiment itself, the theoretical background, or the conclusion are based. Our results open up a broad field for analytics and diagnostics in solution, especially in immunology.