Karell Bien-Aimé
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karell Bien-Aimé has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
C. Belin
ISM-CNRS UMR 5255 351 cours de la Libération 33405 TALENCE cedex, France
1 shared publicationChristine Labrugère
Institut de Chimie de la Matière Condensée de Bordeaux, Centre National de la Recherche Scientifique, Université Bordeaux 1
1 shared publicationColette Belin
Institut des Sciences Moleculaires (Unité Mixte de Recherche 5255), Université Bordeaux 1
1 shared publicationE. Fargin
ICMCB-CNRS 87 Avenue du Docteur Albert Schweitzer 33608 PESSAC cedex, France
1 shared publicationEvelyne Fargin
Institut de Chimie de la Matière Condensée de Bordeaux, Centre National de la Recherche Scientifique, Université Bordeaux 1
1 shared publicationI. Tovena-Pecault
Commissariat à l’énergie atomique, Centre d’études scientifiques et techniques d’Aquitaine, BP 2, 33114 Le Barp, France
1 shared publication
Latest Publications
- 2 October 2009
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (21) , 18703-18713
Impact of storage induced outgassing organic contamination on laser induced damage of silica optics at 351 nm
The impact of storage conditions on laser induced damage density at 351 nm on bare fused polished silica samples has been studied. Intentionally outgassing of polypropylene pieces on silica samples was done. We evidenced an important increase of laser induced damage density on contaminated samples demonstrating that storage could limit optics lifetime performances. Atomic Force Microscopy (AFM) and Gas Chromatography -Mass Spectrometry (GC-MS) have been used to identify the potential causes of this effect. It shows that a small quantity of organic contamination deposited on silica surface is responsible for this degradation. Various hypotheses are proposed to explain the damage mechanism. The more likely hypothesis is a coupling between surface defects of optics and organic contaminants.
- 2 October 2009
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (21) , 18703-18713
Impact of storage induced outgassing organic contamination on laser induced damage of silica optics at 351 nm
The impact of storage conditions on laser induced damage density at 351 nm on bare fused polished silica samples has been studied. Intentionally outgassing of polypropylene pieces on silica samples was done. We evidenced an important increase of laser induced damage density on contaminated samples demonstrating that storage could limit optics lifetime performances. Atomic Force Microscopy (AFM) and Gas Chromatography -Mass Spectrometry (GC-MS) have been used to identify the potential causes of this effect. It shows that a small quantity of organic contamination deposited on silica surface is responsible for this degradation. Various hypotheses are proposed to explain the damage mechanism. The more likely hypothesis is a coupling between surface defects of optics and organic contaminants.
- 14 April 2009
- Published by Optica Publishing Group in Applied Optics
- Vol. 48 (12) , 2228-2235
Laser induced damage of fused silica polished optics due to a droplet forming organic contaminant
We report on the effect of organic molecular contamination on single shot laser induced damage density at the wavelength of , with a pulse length. Specific contamination experiments were made with dioctylphthalate (DOP) in liquid or gaseous phase, on the surface of fused silica polished samples, bare or solgel coated. Systematic laser induced damage was observed only in the case of liquid phase contamination. Different chemical and morphological characterization methods were used to identify and understand the damage process. We demonstrate that the contaminant morphology, rather than its physicochemical nature, can be responsible for the decrease of laser induced damage threshold of optics.- 14 April 2009
- Published by Optica Publishing Group in Applied Optics
- Vol. 48 (12) , 2228-2235
Laser induced damage of fused silica polished optics due to a droplet forming organic contaminant
We report on the effect of organic molecular contamination on single shot laser induced damage density at the wavelength of , with a pulse length. Specific contamination experiments were made with dioctylphthalate (DOP) in liquid or gaseous phase, on the surface of fused silica polished samples, bare or solgel coated. Systematic laser induced damage was observed only in the case of liquid phase contamination. Different chemical and morphological characterization methods were used to identify and understand the damage process. We demonstrate that the contaminant morphology, rather than its physicochemical nature, can be responsible for the decrease of laser induced damage threshold of optics.