Kim Rajappan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kim Rajappan has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Timothy Rider Betts
Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
24 shared publications Yaver Bashir
John Radcliffe Hospital Oxford UK
24 shared publications- David R. Tomlinson
Department of Cardiology, John Radcliffe Hospital, Headley Way, Headington, Oxford OX3 9DU, UK
1 shared publication David Tomlinson
1 shared publicationEmma Withycombe
Barts Health NHS Trust London UK
1 shared publicationG. Wali
John Radcliffe Hospital Oxford UK
1 shared publication
Latest Publications
- 17 April 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 25 (6) , 585-590
Periprocedural Stroke Risk in Patients Undergoing Catheter Ablation for Atrial Fibrillation on Uninterrupted Warfarin
BACKGROUND: Catheter ablation is an effective treatment for symptomatic individuals with atrial fibrillation (AF) but is associated with a risk of periprocedual stroke. Recent data suggest that this risk may be abolished if catheter ablation is performed with uninterrupted warfarin (UW). We sought to compare the incidence, severity and timing of periprocedural stroke between 2 periprocedural anticoagulation protocols: bridging low-molecular-weight heparin (LMWH) and UW. METHODS AND RESULTS: Periprocedural stroke (≤14 days) was assessed in 2,855 ablations performed in 1,813 patients. Thromboembolic stroke occurred in 11/1,653 (0.7%) procedures with bridging LMWH and in 5/1,202 (0.4%) procedures on UW (P = 0.5). Four of the 5 strokes (80%) on UW occurred despite a therapeutic INR and a mean activated clotting time of ≥300 seconds and 4/5 strokes (80%) occurred in patients with a CHADS2 score of 0. Eleven of 16 (69%) strokes overall occurred within 24 hours of the procedure. All 4 strokes resulting in major neurological deficit occurred in the LMWH group. Major bleeding complications occurred in 6.0% of patients in the bridging LMWH group compared to 4.0% in the UW group (P = 0.02). CONCLUSIONS: In contrast to existing data, periprocedural stroke still occurs despite therapeutic anticoagulation throughout the operative period. The optimal strategy to protect patients against thromboembolic stroke remains unclear
- 17 April 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 25 (6) , 585-590
Periprocedural Stroke Risk in Patients Undergoing Catheter Ablation for Atrial Fibrillation on Uninterrupted Warfarin
BACKGROUND: Catheter ablation is an effective treatment for symptomatic individuals with atrial fibrillation (AF) but is associated with a risk of periprocedual stroke. Recent data suggest that this risk may be abolished if catheter ablation is performed with uninterrupted warfarin (UW). We sought to compare the incidence, severity and timing of periprocedural stroke between 2 periprocedural anticoagulation protocols: bridging low-molecular-weight heparin (LMWH) and UW. METHODS AND RESULTS: Periprocedural stroke (≤14 days) was assessed in 2,855 ablations performed in 1,813 patients. Thromboembolic stroke occurred in 11/1,653 (0.7%) procedures with bridging LMWH and in 5/1,202 (0.4%) procedures on UW (P = 0.5). Four of the 5 strokes (80%) on UW occurred despite a therapeutic INR and a mean activated clotting time of ≥300 seconds and 4/5 strokes (80%) occurred in patients with a CHADS2 score of 0. Eleven of 16 (69%) strokes overall occurred within 24 hours of the procedure. All 4 strokes resulting in major neurological deficit occurred in the LMWH group. Major bleeding complications occurred in 6.0% of patients in the bridging LMWH group compared to 4.0% in the UW group (P = 0.02). CONCLUSIONS: In contrast to existing data, periprocedural stroke still occurs despite therapeutic anticoagulation throughout the operative period. The optimal strategy to protect patients against thromboembolic stroke remains unclear
- 1 February 2014
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 7 (1) , 17-22
Development of a Technique for Left Ventricular Endocardial Pacing via Puncture of the Interventricular Septum
Background— Left ventricular (LV) pacing through the coronary sinus is the standard approach for cardiac resynchronization therapy. When this route is unavailable, the alternatives have major limitations. LV endocardial pacing through the interventriuclar septum may offer a simpler solution. We describe an initial case series to demonstrate technical feasibility and to describe our refinement of the puncture technique. Methods and Results— Ten patients with previous failed coronary sinus lead implant or with nonresponse to cardiac resynchronization therapy and a suboptimal LV lead position were selected. All patients were anticoagulated. Left ventriculography and coronary angiography were performed to identify LV borders and septal vessels. Subclavian vein access was used for a superior approach ventricular transseptal puncture under fluoroscopic guidance, using a steerable sheath and a standard transseptal needle, radiofrequency needle, or radiofrequency energy delivered through a guidewire. An active-fixation pacing lead was successfully delivered to the endocardial wall of the lateral LV in all patients (9 men; age, 62±10 years). LV lead implant procedure time shortened with experience. The use of radiofrequency energy delivered through a guidewire was the most effective technique. Mean threshold and R wave at implant were 0.8±0.3 V and 10.8±3.9 mV. At follow-up (mean, 8.7 months; minimum, 0; and maximum 19), thresholds were stable, and there were no thromboembolic events. Of 9 patients, 8 were classed as clinical responders (1 had inadequate follow-up to assess response). Conclusions— LV endocardial pacing through a ventricular septal puncture is a feasible approach for cardiac resynchronization therapy.
- 1 February 2014
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 7 (1) , 17-22
Development of a Technique for Left Ventricular Endocardial Pacing via Puncture of the Interventricular Septum
Background— Left ventricular (LV) pacing through the coronary sinus is the standard approach for cardiac resynchronization therapy. When this route is unavailable, the alternatives have major limitations. LV endocardial pacing through the interventriuclar septum may offer a simpler solution. We describe an initial case series to demonstrate technical feasibility and to describe our refinement of the puncture technique. Methods and Results— Ten patients with previous failed coronary sinus lead implant or with nonresponse to cardiac resynchronization therapy and a suboptimal LV lead position were selected. All patients were anticoagulated. Left ventriculography and coronary angiography were performed to identify LV borders and septal vessels. Subclavian vein access was used for a superior approach ventricular transseptal puncture under fluoroscopic guidance, using a steerable sheath and a standard transseptal needle, radiofrequency needle, or radiofrequency energy delivered through a guidewire. An active-fixation pacing lead was successfully delivered to the endocardial wall of the lateral LV in all patients (9 men; age, 62±10 years). LV lead implant procedure time shortened with experience. The use of radiofrequency energy delivered through a guidewire was the most effective technique. Mean threshold and R wave at implant were 0.8±0.3 V and 10.8±3.9 mV. At follow-up (mean, 8.7 months; minimum, 0; and maximum 19), thresholds were stable, and there were no thromboembolic events. Of 9 patients, 8 were classed as clinical responders (1 had inadequate follow-up to assess response). Conclusions— LV endocardial pacing through a ventricular septal puncture is a feasible approach for cardiac resynchronization therapy.
- Open Access
- 5 December 2012
- Published by Springer Nature
Dual site versus single site irrigated tip catheters in the ablation of atrial flutter
- 5 December 2012
- Published by Springer Nature
Open AccessDual site versus single site irrigated tip catheters in the ablation of atrial flutter
- 27 March 2012
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 35 (6) , 672-680
Questionnaire Survey of Cardiologists’ Knowledge, Attitudes, and Guideline Application of Implantable Cardioverter Defibrillator Therapy
Introduction: There are little data on cardiologists’ knowledge and application of current implantable cardioverter defibrillator (ICD) guidelines, attitudes to risk, and how these may influence ICD prescription. Methods: A questionnaire survey was sent to UK cardiologists to test their knowledge and application of ICD guidelines and their estimate of the clinical benefits gained in different clinical scenarios. They were questioned on the minimum absolute risk reduction (ARR) required to justify an ICD implant and factors that influenced their decision making. Results: Sixty responses from 23 implanters and 37 nonimplanters were obtained. Eighty-three percent implanters and 43% nonimplanters were fully aware of UK ICD National Institute of Clinical Excellence guidelines. Only 7% responders had a screening program to identify primary prevention (PP) candidates. Although the mean estimate of ARR in PP scenarios was similar to trial data, the range of estimates was very wide. The benefit in secondary prevention (SP) scenarios was overestimated by both implanters and nonimplanters. Three-year ARR believed to justify PP and SP ICDs were heavily influenced by patients’ age but in patients . Conclusion: Lack of knowledge of guidelines (particularly in nonimplanters), failure of nonimplanters to offer ICDs to appropriate PP patients, age bias, and a lack of screening programs appear to be the greatest barriers to uptake of ICDs in the United Kingdom, rather than financial concerns. (PACE 2012; 35:672–680)
- 27 March 2012
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 35 (6) , 672-680
Questionnaire Survey of Cardiologists’ Knowledge, Attitudes, and Guideline Application of Implantable Cardioverter Defibrillator Therapy
Introduction: There are little data on cardiologists’ knowledge and application of current implantable cardioverter defibrillator (ICD) guidelines, attitudes to risk, and how these may influence ICD prescription. Methods: A questionnaire survey was sent to UK cardiologists to test their knowledge and application of ICD guidelines and their estimate of the clinical benefits gained in different clinical scenarios. They were questioned on the minimum absolute risk reduction (ARR) required to justify an ICD implant and factors that influenced their decision making. Results: Sixty responses from 23 implanters and 37 nonimplanters were obtained. Eighty-three percent implanters and 43% nonimplanters were fully aware of UK ICD National Institute of Clinical Excellence guidelines. Only 7% responders had a screening program to identify primary prevention (PP) candidates. Although the mean estimate of ARR in PP scenarios was similar to trial data, the range of estimates was very wide. The benefit in secondary prevention (SP) scenarios was overestimated by both implanters and nonimplanters. Three-year ARR believed to justify PP and SP ICDs were heavily influenced by patients’ age but in patients . Conclusion: Lack of knowledge of guidelines (particularly in nonimplanters), failure of nonimplanters to offer ICDs to appropriate PP patients, age bias, and a lack of screening programs appear to be the greatest barriers to uptake of ICDs in the United Kingdom, rather than financial concerns. (PACE 2012; 35:672–680)
- 1 April 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 33 (4) , 389-393
Perioperative Management of Anticoagulation during Device Implantation-The UK Perspective
- 1 April 2010
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 33 (4) , 389-393
Perioperative Management of Anticoagulation during Device Implantation-The UK Perspective
- 1 January 2010
- Published by Oxford University Press (OUP)
- p. 453-477
Ablation of other atrial tachyarrhythmias
- 1 January 2010
- Published by Oxford University Press (OUP)
- p. 453-477
Ablation of other atrial tachyarrhythmias
- 1 January 2010
- Published by Oxford University Press (OUP)
- p. 360-393
Ablation of accessory pathways and atrio-ventricular re-entrant tachycardia (AVRT)
- 1 January 2010
- Published by Oxford University Press (OUP)
- p. 360-393
Ablation of accessory pathways and atrio-ventricular re-entrant tachycardia (AVRT)
- 1 January 2010
- Published by Oxford University Press (OUP)
- p. 349-359
Ablation of atrio-ventricular nodal re-entrant tachycardia (AVNRT)
- 1 January 2010
- Published by Oxford University Press (OUP)
- p. 349-359
Ablation of atrio-ventricular nodal re-entrant tachycardia (AVNRT)
- 1 January 2010
- Published by Oxford University Press (OUP)
- p. 307-325
Ventricular tachycardia
- 1 January 2010
- Published by Oxford University Press (OUP)
- p. 285-305
Atrial tachycardia and AF