DODesmond O'COnnor

Desmond O'COnnor

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Desmond O'COnnor has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Alan P. Watt

    Merck Sharp & Dohme Research Laboratories, Department of Medicinal Chemistry (Drug Metabolism Section), Neuroscience Research Centre, Terlings Park, Eastwick Road, Harlow, Essex CM20 2QR, UK

    2 shared publications
  • Denise Morrison

    Merck Sharp & Dohme Research Laboratories, Department of Medicinal Chemistry (Drug Metabolism Section), Neuroscience Research Centre, Terlings Park, Eastwick Road, Harlow, Essex CM20 2QR, UK

    2 shared publications
  • Amy Davies

    Merck Sharp & Dohme Research Laboratories, Department of Medicinal Chemistry (Drug Metabolism Section), Neuroscience Research Centre, Terlings Park, Eastwick Road, Harlow, Essex CM20 2QR, UK

    1 shared publication
  • Dawn E. Clarke

    Merck Sharp & Dohme Research Laboratories, Department of Medicinal Chemistry (Drug Metabolism Section), Neuroscience Research Centre, Terlings Park, Eastwick Road, Harlow, Essex CM20 2QR, UK

    1 shared publication
  • Jane Kirby

    Waters Corporation (MS Technology Centre), Atlas Park, Simonsway, Manchester M22 5PP, UK

    1 shared publication
  • Jose M. Castro‐Perez

    Waters Corporation (MS Technology Centre), Atlas Park, Simonsway, Manchester M22 5PP, UK

    1 shared publication

Latest Publications

  • High-throughput bioanalysis with simultaneous acquisition of metabolic route data using ultra performance liquid chromatography coupled with time-of-flight mass spectrometry

    by Desmond O’cOnnor, Russell Mortishire-Smith

    The capability of ultra performance liquid chromatography coupled with time-of-flight mass spectrometry (UPLC/TOFMS) in the high-throughput quantitative analysis of a drug candidate in plasma has been investigated. Data obtained were compared with results from conventional analysis by high-performance liquid chromatography with tandem mass spectrometric detection on a triple quadrupole instrument (HPLC/MS/MS). The accuracies and precisions of the two approaches were comparable. The UPLC/TOFMS system displayed excellent robustness over the course of 276 injections of protein-precipitated plasma samples. With the instrumentation used, the limits of detection and quantification were approximately five-fold higher with UPLC/TOFMS than for HPLC/MS/MS. Nevertheless, the UPLC/TOFMS system proved adequate to quantify plasma concentrations of a drug molecule administered orally to rats at a pharmacologically relevant dose of 4 mg/kg. As well as providing quantitative data on the test compound, it was also possible to extract data for eight different metabolites, including several isomeric species (three +O and three +2O) from the UPLC/TOFMS data sets, using an analytical method with a 2.5-minute run time. Selectivity for the test compound and its metabolites was derived from the accurate mass capabilities of the TOF instrument, and no MS method development was required.


  • Ultra‐performance liquid chromatography coupled to time‐of‐flight mass spectrometry for robust, high‐throughput quantitative analysis of an automated metabolic stability assay, with simultaneous determination of metabolic data

    by Desmond O'COnnor, Russell Mortishire‐Smith, Denise Morrison, Amy Davies, Maria Dominguez

    The application of ultra‐performance liquid chromatography coupled to time‐of‐flight mass spectrometry (UPLC/TOFMS) for high‐throughput analysis of a 96‐well plate based metabolic stability assay has been investigated. Full‐scan data were acquired, with run times of 2.5–3.5 min, from which narrow window extracted ion chromatograms were generated, producing quantitative data for the test compound equivalent to that obtained by high‐performance liquid chromatography with tandem mass spectrometric detection on a triple quadrupole instrument (HPLC/MS/MS). Sensitivity and mass accuracy were maintained over the analysis of >300 samples. Additionally, the UPLC/TOFMS datasets obtained gave access to metabolic route information, at no cost in terms of sensitivity for the test compound. Copyright © 2006 John Wiley & Sons, Ltd.


  • Accelerated throughput metabolic route screening in early drug discovery using high‐resolution liquid chromatography/quadrupole time‐of‐flight mass spectrometry and automated data analysis

    by Russell J. Mortishire‐Smith, Desmond O'COnnor, Jose M. Castro‐Perez, Jane Kirby

    The resource investment required to characterise the metabolic fate of a compound is relatively large, meaning that within a drug discovery environment relatively few compounds are characterised in depth. Rate‐limiting steps include the setting up of a complex array of mass spectrometry experiments and the subsequent analysis of the large data sets produced. We describe here a strategy for the evaluation of metabolic routes using full‐scan high‐resolution liquid chromatography/quadrupole time‐of‐flight mass spectrometry (LC/QToFMS) with automated data analysis using Metabolynx™, a commercially available software package. Data from several structurally diverse compounds taken from the literature illustrate that, with careful setting of key parameters, this approach is able to indicate the presence of a wide range of metabolites with only a limited requirement for manual intervention. Copyright © 2005 John Wiley & Sons, Ltd.


  • Determination of drug concentrations in plasma by a highly automated, generic and flexible protein precipitation and liquid chromatography/tandem mass spectrometry method applicable to the drug discovery environment

    by Desmond O'COnnor, Dawn E. Clarke, Denise Morrison, Alan P. Watt

    This report presents a highly automated procedure for the determination of drug concentrations in plasma samples. The method is generic, in that it has been applied without adaptation to many different drug candidate molecules, but is also flexible, in that variations in the nature and number of samples to be analyzed can be readily accommodated. The method includes preparation of dilutions of analyte stock solutions, spiking these into control plasma to generate analytical standards, and preparation of samples suitable for analysis by high‐performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) by precipitation of plasma proteins with acetonitrile, centrifugation, and dilution of the supernatants with HPLC buffer. All of these steps, apart from centrifugation, are performed without manual intervention on an automated liquid‐handling workstation using 96‐well plates. Analysis is by HPLC/MS/MS, using a generic HPLC gradient. Commercially available software was used for optimization of parameters for analysis by HPLC/MS/MS, integration of chromatographic peaks, and quantification of drug concentrations. The use of this methodology in our laboratory has greatly facilitated the analysis of small sample sets for a large number of analytes, a situation regularly encountered in an early drug discovery environment. Copyright © 2002 John Wiley & Sons, Ltd.


    • 1 January 2002
      • Vol. 5  (1) , 52-8

    Automated sample preparation and LC-MS for high-throughput ADME quantification.

    by Desmond O'Connor

    Bioanalytical groups in the pharmaceutical industry provide quantitative data to support all stages of drug discovery. The increased use of 96-well plates and robotic liquid handling systems, the availability of robust triple quadruple mass spectrometers, and developments in chromatographic and samples preparation techniques, have all increased the rate at which this data can be generated. This review describes currently used methods and emerging technologies for automation of high-throughput quantitative bioanalysis. The focus is on recent applications of sample preparation and chromatography techniques compatible with detection by triple quadruple mass spectrometers.

  • In VitroStudies of the Oxidative Metabolism of L-737,415, A C5-Cycloalkylamine-1,4-Benzodiazepin-2-One CCKBReceptor Antagonist

    by Alan P. Watt, Desmond O'Connor, Steve Thomas, Richard H. Herbert, Victor G. Matassa

    In an effort to investigate and characterise the metabolism of the C5-cycloalkylamine-1,4-benzodiazepin-2-one CCKB receptor antagonist L-737,415 a study was undertaken using rat liver microsomes. A procedure is described in which the metabolism of the unlabelled compound is firstly investigated analytically under a controlled set of conditions, then scaled up to allow further metabolite elucidation. We also report the use of HPLC with diode array detection, and thermospray LC-MS and LC-MS-MS, to detect and characterise the observed metabolites. From the UV spectra obtained with diode array detection and fragmentation analysis from LC-MS-MS it is demonstrated that, contrary to other known benzodiazepinones such as diazepam or the CCKB antagonist L-365,260, metabolism seems to occur predominantly at the C5 substituent. Further work in which urine from rats dosed with L-737,415 was analysed indicated that the in vitro microsomal assay provides a good model for in vivo metabolism for this class of compounds.