Amir Halkin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Amir Halkin has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Shmuel Banai
Division of Cardiology, Tel Aviv Sourasky University Medical Center (Ichilov), Israel (S.G., G.M., Y.P., E.S., M.R., H.S., S.B., J.B.-S., M.K.).
9 shared publications Ariel Finkelstein
Department of Cardiology, Tel Aviv Medical Center, Tel Aviv, Israel; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
8 shared publications- Gad Keren
Department of Cardiology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
8 shared publications - Arie Steinvil
Sackler School of Medicine, Tel-Aviv University, Tel Aviv 69978, Israel
6 shared publications - Yaron Arbel
Division of Cardiology, Faculty of Medical & Health Sciences, Tel-Aviv Sourasky Medical Center, Tel Aviv University, Tel Aviv, Israel
6 shared publications - Eran Leshem-Rubinow
Technion Israel Institute of Technology The Ruth and Bruce Rappaport Faculty of Medicine, Technion City Haifa Israel
4 shared publications
Latest Publications
- 1 November 2017
- Published by Elsevier in Journal of Cardiology
- Vol. 70 (5) , 491-497
Diastolic mitral regurgitation following transcatheter aortic valve replacement: Incidence, predictors, and association with clinical outcomes
- 1 November 2017
- Published by Elsevier in Journal of Cardiology
- Vol. 70 (5) , 491-497
Diastolic mitral regurgitation following transcatheter aortic valve replacement: Incidence, predictors, and association with clinical outcomes
- 1 August 2015
- Vol. 17 (8) , 500-4
Anemia in ST-Elevation Myocardial Infarction Patients with Markers of Inadequate Bone Marrow Response.
Anemia confers an adverse prognosis in patients with ST-elevation myocardial infarction (STEMI). Several mechanisms have been implicated in the etiology of anemia in this setting, including inflammation, blood loss, and the presence of comorbidities such as renal failure. To evaluate the adequacy of bone marrow response as potentially reflected by elevation in blood and reticulocyte counts. Consecutive men with STEMI who underwent primary percutaneous intervention within 6 hours of symptom onset and who presented to our catheterization laboratory during a 36 month period were included in the study. The cohort was divided into quartiles according to hemoglobin concentration, and differences in clinical and laboratory characteristics between the groups were evaluated. A total of 258 men with STEMI were recruited, 22% of whom suffered from anemia according to the World Health Organization classification (hemoglobin < 13 g/dl). Men in the lowest quartile of hemoglobin concentration presented with significantly lower white blood cell and platelet counts (9.6 ± 2.9 vs. 12.6 ± 3.6 x 103/μl, P < 0.001) and (231 ± 79 vs. 263 ± 8 x 103/μl, P < 0.01), respectively, despite higher inflammatory biomarkers (C-reactive protein and fibrinogen) compared with patients in the upper hemoglobin concentration quartile. Reticulocyte production index was not significantly higher in anemic patients, with a value of 1.8, 1.4, 1.5 and 1.6 in the ascending hemoglobin quartiles, respectively (P = 0.292). Anemic men with STEMI have relatively lower leukocyte and platelet counts as well as a reduced reticulocyte count despite higher inflammatory biomarkers. These findings might suggest inadequate bone marrow response.
- 1 August 2015
- Vol. 17 (8) , 500-4
Anemia in ST-Elevation Myocardial Infarction Patients with Markers of Inadequate Bone Marrow Response.
Anemia confers an adverse prognosis in patients with ST-elevation myocardial infarction (STEMI). Several mechanisms have been implicated in the etiology of anemia in this setting, including inflammation, blood loss, and the presence of comorbidities such as renal failure. To evaluate the adequacy of bone marrow response as potentially reflected by elevation in blood and reticulocyte counts. Consecutive men with STEMI who underwent primary percutaneous intervention within 6 hours of symptom onset and who presented to our catheterization laboratory during a 36 month period were included in the study. The cohort was divided into quartiles according to hemoglobin concentration, and differences in clinical and laboratory characteristics between the groups were evaluated. A total of 258 men with STEMI were recruited, 22% of whom suffered from anemia according to the World Health Organization classification (hemoglobin < 13 g/dl). Men in the lowest quartile of hemoglobin concentration presented with significantly lower white blood cell and platelet counts (9.6 ± 2.9 vs. 12.6 ± 3.6 x 103/μl, P < 0.001) and (231 ± 79 vs. 263 ± 8 x 103/μl, P < 0.01), respectively, despite higher inflammatory biomarkers (C-reactive protein and fibrinogen) compared with patients in the upper hemoglobin concentration quartile. Reticulocyte production index was not significantly higher in anemic patients, with a value of 1.8, 1.4, 1.5 and 1.6 in the ascending hemoglobin quartiles, respectively (P = 0.292). Anemic men with STEMI have relatively lower leukocyte and platelet counts as well as a reduced reticulocyte count despite higher inflammatory biomarkers. These findings might suggest inadequate bone marrow response.
- Open Access
- 2 July 2014
- Published by Springer Nature in Trials
- Vol. 15 (1) , 262
Forced diuresis with matched hydration in reducing acute kidney injury during transcatheter aortic valve implantation (Reduce-AKI): study protocol for a randomized sham-controlled trial
Acute kidney injury (AKI) is observed in up to 41% of patients undergoing transcatheter aortic valve implantation (TAVI) and is associated with increased risk for mortality. The aim of the present study is to evaluate whether furosemide-induced diuresis with matched isotonic intravenous hydration using the RenalGuard system reduces AKI in patients undergoing TAVI. Reduce-AKI is a randomized sham-controlled study designed to examine the effect of an automated matched hydration system in the prevention of AKI in patients undergoing TAVI. Patients will be randomized in a 1:1 fashion to the RenalGuard system (active group) versus non-matched saline infusion (sham-controlled group). Both arms receive standard overnight saline infusion and N-acetyl cysteine before the procedure. The Reduce-AKI trial will investigate whether the use of automated forced diuresis with matched saline infusion is an effective therapeutic tool to reduce the occurrence of AKI in patients undergoing TAVI. Clinicaltrials.gov: NCT01866800, 30 April 30 2013.
- 2 July 2014
- Published by Springer Nature in Trials
- Vol. 15 (1) , 262
Open AccessForced diuresis with matched hydration in reducing acute kidney injury during transcatheter aortic valve implantation (Reduce-AKI): study protocol for a randomized sham-controlled trial
Acute kidney injury (AKI) is observed in up to 41% of patients undergoing transcatheter aortic valve implantation (TAVI) and is associated with increased risk for mortality. The aim of the present study is to evaluate whether furosemide-induced diuresis with matched isotonic intravenous hydration using the RenalGuard system reduces AKI in patients undergoing TAVI. Reduce-AKI is a randomized sham-controlled study designed to examine the effect of an automated matched hydration system in the prevention of AKI in patients undergoing TAVI. Patients will be randomized in a 1:1 fashion to the RenalGuard system (active group) versus non-matched saline infusion (sham-controlled group). Both arms receive standard overnight saline infusion and N-acetyl cysteine before the procedure. The Reduce-AKI trial will investigate whether the use of automated forced diuresis with matched saline infusion is an effective therapeutic tool to reduce the occurrence of AKI in patients undergoing TAVI. Clinicaltrials.gov: NCT01866800, 30 April 30 2013.
- 1 October 2013
- Vol. 15 (10) , 613-6
Transcatheter aortic valve implantation: a single-center experience of 300 cases.
Transcatheter aortic valve implantation (TAVI) has recently become an alternative to surgical aortic valve replacement in selected patients with high operative risk. To investigate the 30 day clinical outcome of the first 300 consecutive patients treated with transfemoral TAVI at the Tel Aviv Medical Center. The CoreValve was used in 250 patients and the Edwards-Sapien valve in 50. The mean age of the patients was 83 +/- 5.3 years (range 63-98 years) and the mean valve area 0.69 +/- 0.18 cm2 (range 0.3-0.9 cm2); 62% were women. The procedural success rate was 100%, and 30 day follow-up was done in all the patients. The average Euro-score for the cohort was 26 +/- 13 (range 1.5-67). Total in-hospital mortality and 30 day mortality were both 2.3% (7 patients). Sixty-seven patients (22%) underwent permanent pacemaker implantation after the TAVI procedure, mostly due to new onset of left bundle brunch block and prolonged PR interval or to high degree atrioventricular block. The rate of stroke was 1.7% (5 patients). Forty-one patients (13.7%) had vascular complications, of whom 9 (3%) were defined as major vascular complications (according to the VARC definition). The 30 day clinical outcome in the first 300 consecutive TAVI patients in our center was favorable, with a mortality rate of 2.3% and low rates of stroke (1.7%) and major vascular complications (3%).
- 1 October 2013
- Vol. 15 (10) , 613-6
Transcatheter aortic valve implantation: a single-center experience of 300 cases.
Transcatheter aortic valve implantation (TAVI) has recently become an alternative to surgical aortic valve replacement in selected patients with high operative risk. To investigate the 30 day clinical outcome of the first 300 consecutive patients treated with transfemoral TAVI at the Tel Aviv Medical Center. The CoreValve was used in 250 patients and the Edwards-Sapien valve in 50. The mean age of the patients was 83 +/- 5.3 years (range 63-98 years) and the mean valve area 0.69 +/- 0.18 cm2 (range 0.3-0.9 cm2); 62% were women. The procedural success rate was 100%, and 30 day follow-up was done in all the patients. The average Euro-score for the cohort was 26 +/- 13 (range 1.5-67). Total in-hospital mortality and 30 day mortality were both 2.3% (7 patients). Sixty-seven patients (22%) underwent permanent pacemaker implantation after the TAVI procedure, mostly due to new onset of left bundle brunch block and prolonged PR interval or to high degree atrioventricular block. The rate of stroke was 1.7% (5 patients). Forty-one patients (13.7%) had vascular complications, of whom 9 (3%) were defined as major vascular complications (according to the VARC definition). The 30 day clinical outcome in the first 300 consecutive TAVI patients in our center was favorable, with a mortality rate of 2.3% and low rates of stroke (1.7%) and major vascular complications (3%).
- 1 November 2010
- Vol. 12 (11) , 692-6
Comparative efficacy analysis of an aspiration device before primary angioplasty in patients with acute myocardial infarction: a single-center experience.
ST-elevation myocardial infarction is caused by occlusive coronary thrombosis where antecedent plaque disruption occurs. When treating STEMI the main goal is to achieve prompt reperfusion of the infarction area. Several studies have demonstrated the efficacy of an aspiration device before percutaneous coronary intervention in patients with acute myocardial infarction. To determine the added value of thrombus aspiration prior to primary PCI by comparing AMI patients with totally occluded infarct-related artery treated with routine primary PCI to those treated with extraction device prior to primary PCI. The study group comprised 122 consecutive patients with AMI and a totally occluded infarct artery (TIMI flow 0) who underwent primary PCI. The patients were divided into two groups: 68 who underwent primary PCI only (control group) and 54 who underwent primary thrombus extraction with an extraction device before PCI (extraction group). Baseline clinical and lesion characteristics were similar in both groups. Final TIMI grade flow and myocardial blush as well as 1 year mortality, target lesion revascularization, recurrent myocardial infarction, unstable angina and stroke were compared between the two groups. Primary angiographic results were better for the extraction group versus the control group: final grade 3 TIMI flow was 100% vs. 95.6% (P= 0.03) and final grade 3 myocardial blush grade 50% vs. 41.18% (although Pwas not significant). Long-term follow-up total MACE showed a nonsignificant positive trend in the extraction group (12.96% vs. 24.71%, P= 0.26). The use of extraction devices for intracoronary thrombectomy during primary PCI in patients with totally occluded infarct artery significantly improved epicardial reperfusion in the infarct-related vessel and showed a trend for more favorable long-term outcome.
- 1 November 2010
- Vol. 12 (11) , 692-6
Comparative efficacy analysis of an aspiration device before primary angioplasty in patients with acute myocardial infarction: a single-center experience.
ST-elevation myocardial infarction is caused by occlusive coronary thrombosis where antecedent plaque disruption occurs. When treating STEMI the main goal is to achieve prompt reperfusion of the infarction area. Several studies have demonstrated the efficacy of an aspiration device before percutaneous coronary intervention in patients with acute myocardial infarction. To determine the added value of thrombus aspiration prior to primary PCI by comparing AMI patients with totally occluded infarct-related artery treated with routine primary PCI to those treated with extraction device prior to primary PCI. The study group comprised 122 consecutive patients with AMI and a totally occluded infarct artery (TIMI flow 0) who underwent primary PCI. The patients were divided into two groups: 68 who underwent primary PCI only (control group) and 54 who underwent primary thrombus extraction with an extraction device before PCI (extraction group). Baseline clinical and lesion characteristics were similar in both groups. Final TIMI grade flow and myocardial blush as well as 1 year mortality, target lesion revascularization, recurrent myocardial infarction, unstable angina and stroke were compared between the two groups. Primary angiographic results were better for the extraction group versus the control group: final grade 3 TIMI flow was 100% vs. 95.6% (P= 0.03) and final grade 3 myocardial blush grade 50% vs. 41.18% (although Pwas not significant). Long-term follow-up total MACE showed a nonsignificant positive trend in the extraction group (12.96% vs. 24.71%, P= 0.26). The use of extraction devices for intracoronary thrombectomy during primary PCI in patients with totally occluded infarct artery significantly improved epicardial reperfusion in the infarct-related vessel and showed a trend for more favorable long-term outcome.