SSSamuel M. Stavis

Samuel M. Stavis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Samuel M. Stavis has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Measurement Error Models Enable Accurate Correlation of Nanoscale Properties and Structures

    by Adam L. Pintar, Andrew C. Madison, Craig R. Copeland, Natalia Farkas, Samuel M. Stavis

    Measurement errors can catastrophically bias parameter estimates in models to correlate nanoscale properties and structures, undercutting a foundation of nanoscience and nanotechnology. In a general solution to this latent problem, we derive a method-of-moments correction for least-squares estimates of correlative model parameters. Our correction applies to many relations of dependent and independent variables, subject to many types of measurement errors of the independent variable. Focusing on the prevalent power-law model to correlate optical intensity and nanoparticle size, we test the limits of accuracy of our correction and study the use of either reference size distributions or sizing uncertainty estimates to inform a measurement error model. We critically evaluate representative measurements of various nanoparticles, impacting the conclusions of several studies and changing expectations of intensity scaling exponents for nanoscale optical inferences. Our correction is immediately available, highly interpretable, and broadly applicable to gain reliable insights and prevent future mistakes.

  • Traceable localization enables accurate integration of quantum emitters and photonic structures with high yield

    by Craig R. Copeland, Adam L. Pintar, Ronald G. Dixson, Ashish Chanana, Kartik Srinivasan, Daron A. Westly, B. Robert Ilic, Marcelo I. Davanco, Samuel M. Stavis

    In a popular integration process for quantum information technologies, localization microscopy of quantum emitters guides lithographic placement of photonic structures. However, a complex coupling of microscopy and lithography errors degrades registration accuracy, severely limiting device performance and process yield. We introduce a methodology to solve this widespread but poorly understood problem. A new foundation of traceable localization enables rapid characterization of lithographic standards and comprehensive calibration of cryogenic microscopes, revealing and correcting latent systematic effects. Of particular concern, we discover that scale factor deviation and complex optical distortion couple to dominate registration errors. These novel results parameterize a process model for integrating quantum dots and bullseye resonators, predicting higher yield by orders of magnitude, depending on the Purcell factor threshold as a quantum performance metric. Our foundational methodology is a key enabler of the lab-to-fab transition of quantum information technologies and has broader implications to cryogenic and correlative microscopy.


  • Open Access

    Letter to the Editor Concerning "Simultaneous, Single-Particle Measurements of Size and Loading Give Insights into the Structure of Drug-Delivery Nanoparticles"

    by Andrew C. Madison, Adam L. Pintar, Craig R. Copeland, Natalia Farkas, Samuel M. Stavis

    The vexing error of excess variance in the sizing of single particles degrades accuracy in applications ranging from quality control of nanoparticle products to hazard assessment of nanoplastic byproducts. The particular importance of lipid nanoparticles for vaccine and medicine delivery motivates this comment on a publication$^{\textrm{1}}$ in ACS Nano. In ref 1, the benchmark measurements of a nanoparticle standard manifest large errors of the size distribution that contradict the claim of validation. Such errors can bias the correlation of fluorescence intensity as an optical proxy for the molecular loading of lipid nanoparticles and give misleading insights from power-law models of intensity$-$size data. Looking forward, measurement error models have the potential to address this widespread issue.

  • Open Access

    Traceable localization enables accurate integration of quantum emitters and photonic structures with high yield

    by Craig R. Copeland, Adam L. Pintar, Ronald G. Dixson, Ashish Chanana, Kartik Srinivasan, Daron A. Westly, B. Robert Ilic, Marcelo I. Davanco, Samuel M. Stavis

    Traceability to the International System of Units (SI) is fundamental to measurement accuracy and reliability. In this study, we demonstrate subnanometer traceability of localization microscopy, establishing a metrological foundation for the maturation and application of super-resolution methods. To do so, we create a master standard by measuring the positions of submicrometer apertures in an array by traceable atomic-force microscopy. We perform correlative measurements of this master standard by optical microscopy, calibrating scale factor and correcting aberration effects. We introduce the concept of a localization uncertainty field due to optical localization errors and scale factor uncertainty, with regions of position traceability to within a 68 % coverage interval of +/- 1 nm. These results enable localization metrology with high throughput, which we apply to measure working standards that we fabricate by electron-beam lithography, validating the accuracy of mean pitch and closing the loop for disseminating and integrating reference arrays. We then apply our novel methods to calibrate an optical microscope with a sample cryostat, accounting for thermal contraction by use of a submicrometer pillar array in silicon as a reference material and elucidating complex distortion. This new calibration enables the accurate integration of quantum emitters and photonic structures with high yield, as we demonstrate theoretically through simulations of the dependence of the Purcell factor of radiative enhancement on registration errors across a wide field. Our study illuminates the challenges and opportunities of achieving traceable localization for comparison of position data across lithography and microscopy systems, from ambient to cryogenic temperatures.


  • Open Access

    Unmasking the resolution$-$throughput tradespace of focused-ion-beam machining

    by Andrew C. Madison, John S. Villarrubia, Kuo-Tang Liao, Craig R. Copeland, Joshua Schumacher, Kerry Siebein, B. Robert Ilic, J. Alexander Liddle, Samuel M. Stavis

    Focused-ion-beam machining is a powerful process to fabricate complex nanostructures, often through a sacrificial mask that enables milling beyond the resolution limit of the ion beam. However, current understanding of this super-resolution effect is empirical in the spatial domain and nonexistent in the temporal domain. This article reports the primary study of this fundamental tradespace of resolution and throughput. Chromia functions well as a masking material due to its smooth, uniform, and amorphous structure. An efficient method of in-line metrology enables characterization of ion-beam focus by scanning electron microscopy. Fabrication and characterization of complex test-structures through chromia and into silica probe the response of the bilayer to a focused beam of gallium cations, demonstrating super-resolution factors of up to 6 $\pm$ 2 and improvements to volume throughput of at least factors of 42 $\pm$ 2, with uncertainties denoting 95 % coverage intervals. Tractable theory models the essential aspects of the super-resolution effect for various nanostructures. Application of the new tradespace increases the volume throughput of machining Fresnel lenses by a factor of 75, which we introduce as projection standards for optical microscopy. These results enable paradigm shifts of sacrificial masking from empirical to engineering design, and from prototyping to manufacturing.

  • Open Access

    Unmasking the Resolution–Throughput Tradespace of Focused‐Ion‐Beam Machining

    by Andrew C. Madison, John S. Villarrubia, Kuo‐Tang Liao, Craig R. Copeland, Joshua Schumacher, Kerry Siebein, B. Robert Ilic, J. Alexander Liddle, Samuel M. Stavis

    Focused‐ion‐beam machining is a powerful process to fabricate complex nanostructures, often through a sacrificial mask that enables milling beyond the resolution limit of the ion beam. However, current understanding of this super‐resolution effect is empirical in the spatial domain and nonexistent in the temporal domain. This article reports the primary study of this fundamental tradespace of resolution and throughput. Chromia functions well as a masking material due to its smooth, uniform, and amorphous structure. An efficient method of in‐line metrology enables characterization of ion‐beam focus by scanning electron microscopy. Fabrication and characterization of complex test structures through chromia and into silica probe the response of the bilayer to a focused beam of gallium cations, demonstrating super‐resolution factors of up to 6 ± 2 and improvements to volume throughput of at least factors of 42 ± 2, with uncertainties denoting 95% coverage intervals. Tractable theory models the essential aspects of the super‐resolution effect for various nanostructures. Application of the new tradespace increases the volume throughput of machining Fresnel lenses by a factor of 75, enabling the introduction of projection standards for optical microscopy. These results enable paradigm shifts of sacrificial masking from empirical to engineering design and from prototyping to manufacturing.


  • Open Access

    A lateral nanoflow assay reveals nanoplastic fluorescence heterogeneity

    by Kuo-Tang Liao, Andrew C. Madison, Adam L. Pintar, B. Robert Ilic, Craig R. Copeland, Samuel M. Stavis

    Plastic nanoparticles present technological opportunities and environmental concerns, but measurement challenges impede product development and hazard assessment. To meet these challenges, we advance a lateral nanoflow assay that integrates complex nanofluidic replicas, optical localization microscopy, and novel statistical analyses. We apply our sample-in-answer-out system to measure polystyrene nanoparticles that sorb and carry hydrophobic fluorophores. An elegant scaling of surface forces automates advection and dominates diffusion to drive the analytical separation of colloidal nanoparticles by their steric diameters. Reference nanoparticles, with a mean of 99 nm and a standard deviation of 8.4 nm, test the unknown limits of silicone replicas to function as separation matrices. New calibrations correct aberrations from microscope and device, improving the accuracy of reducing single micrographs to joint histograms of steric diameter and fluorescence intensity. A dimensional model approaches the information limit of the system to discriminate size exclusion from surface adsorption, yielding errors of the mean ranging from 0.2 nm to 2.3 nm and errors of the standard deviation ranging from 2.2 nm to 4.2 nm. A hierarchical model accounts for metrological, optical, and dimensional variability to reveal a fundamental structure-property relationship. Intensity scales with diameter to the power of 3.6 +/- 0.5 at 95 % coverage, confounding basic concepts of surface adsorption or volume absorption. Distributions of fluorescivity - the product of the number density, absorption cross section, and quantum yield of an ensemble of fluorophores - are ultrabroad and asymmetric, limiting any inference from fluorescence intensity. This surprising characterization of common nanoplastics resets expectations for optimizing products, applying standards, and understanding byproducts.


  • Open Access

    Sub-picoliter Traceability of Microdroplet Gravimetry and Microscopy

    by Lindsay C. C. Elliott, Adam L. Pintar, Craig R. Copeland, Thomas B. Renegar, Ronald G. Dixson, B. Robert Ilic, R. Michael Verkouteren, Samuel M. Stavis

    Gravimetry typically lacks the resolution to measure single microdroplets, whereas microscopy is often inaccurate beyond the resolution limit. To address these issues, we advance and integrate these complementary methods, introducing simultaneous measurements of the same microdroplets, comprehensive calibrations that are independently traceable to the International System of Units (SI), and Monte-Carlo evaluations of volumetric uncertainty. We achieve sub-picoliter agreement of measurements of microdroplets in flight with volumes of approximately 70 pL, with ensemble gravimetry and optical microscopy both yielding 95% coverage intervals of +/- 0.6 pL, or relative uncertainties of +/- 0.9%, and root-mean-square deviations of mean values between the two methods of 0.2 pL or 0.3%. These uncertainties match previous gravimetry results and improve upon previous microscopy results by an order of magnitude. Gravimetry precision depends on the continuity of droplet formation, whereas microscopy accuracy requires that optical diffraction from an edge reference matches that from a microdroplet. Applying our microscopy method, we jet and image water microdroplets suspending fluorescent nanoplastics, count nanoplastic particles after deposition and evaporation, and transfer volumetric traceability to number concentration. We expect that our methods will impact diverse fields involving dimensional metrology and volumetric analysis of microdroplets, including inkjet microfabrication, disease transmission, and industrial sprays.

  • Open Access

    Sub-picoliter Traceability of Microdroplet Gravimetry and Microscopy

    by Lindsay C. C. Elliott, Adam L. Pintar, Craig R. Copeland, Thomas B. Renegar, Ronald G. Dixson, B. Robert Ilic, R. Michael Verkouteren, Samuel M. Stavis

    Gravimetry typically lacks the resolution to measure single microdroplets, whereas microscopy is often inaccurate beyond the resolution limit. To address these issues, we advance and integrate these complementary methods, introducing simultaneous measurements of the same microdroplets, comprehensive calibrations that are independently traceable to the International System of Units (SI), and Monte-Carlo evaluations of volumetric uncertainty. We achieve sub-picoliter agreement of measurements of microdroplets in flight with volumes of approximately 70 pL, with ensemble gravimetry and optical microscopy both yielding 95% coverage intervals of ±0.6 pL, or relative uncertainties of ±0.9%, and root-mean-square deviations of mean values between the two methods of 0.2 pL or 0.3%. These uncertainties match previous gravimetry results and improve upon previous microscopy results by an order of magnitude. Gravimetry precision depends on the continuity of droplet formation, whereas microscopy accuracy requires that optical diffraction from an edge reference matches that from a microdroplet. Applying our microscopy method, we jet and image water microdroplets suspending fluorescent nanoplastics, count nanoplastic particles after deposition and evaporation, and transfer volumetric traceability to the number concentrations of single microdroplets. We expect that our methods will impact diverse fields involving dimensional metrology and volumetric analysis of microdroplets, including inkjet microfabrication, disease transmission, and industrial sprays.