HEHossein Elgafy

Hossein Elgafy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hossein Elgafy has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Biomechanical Analysis Comparing Three C1–C2 Transarticular Screw Salvaging Fixation Techniques

    by Hossein Elgafy, Tejaswy Potluri, Vijay K. Goel, Scott Foster, Ahmad Faizan, Nikhil Kulkarni

    This is an in vitro biomechanical study. To compare the biomechanical stability of the 3 C1–C2 transarticular screw salvaging fixation techniques. Stabilization of the atlantoaxial complex is a challenging procedure because of its complicated anatomy. Many posterior stabilization techniques of the atlantoaxial complex have been developed with C1–C2 transarticular screw fixation been the current gold standard. The drawback of using the transarticular screws is that it has a potential risk of vertebral artery injury due to a high riding transverse foramen of C2 vertebra, and screw malposition. In such cases, it is not recommended to proceed with inserting the contralateral transarticular screw and the surgeon should find an alternative to fix the contralateral side. Many studies are available comparing different atlantoaxial stabilization techniques, but none of them compared the techniques to fix the contralateral side while using the transarticular screw on one side. The current options are C1 lateral mass screw and short C2 pedicle screw or C1 lateral mass screw and C2 intralaminar screw, or C1–C2 sublaminar wire. Nine fresh human cervical spines with intact ligaments (C0–C4) were subjected to pure moments in the 6 loading directions. The resulting spatial orientations of the vertebrae were recorded using an Optotrak 3-dimensional Motion Measurement System. Measurements were made sequentially for the intact spine after creating type II odontoid fracture and after stabilization with unilateral transarticular screw placement across C1–C2 (TS) supplemented with 1 of the 3 transarticular salvaging techniques on the contralateral side; C1 lateral mass screw and C2 pedicle screw (TS+C1LMS+C2PS), C1 lateral mass and C2 intralaminar screw (TS+C1LMS+C2ILS), or sublaminar wire (TS + wire). The data indicated that all the 3 stabilization techniques significantly decreased motion when compared to intact in all the loading cases (left/right lateral bending, left/right axial rotation, flexion) except extension. All the 3 instrumented specimens were equally stable in extension/flexion and lateral bending modes. TS+C1LMS+C2PS was equivalent to TS+C1LMS+C2ILS (P > 0.05) and superior to TS + wire in axial rotation (P < 0.05). Also, TS+C1LMS+C2ILS was superior to TS + wire in axial rotation (P < 0.05). Fixation of atlantoaxial complex using unilateral transarticular screw supplemented with contralateral C1 lateral mass and C2 intralaminar screws is biomechanically equivalent to C1 lateral mass and C2 pedicle screws and both are biomechanically superior to C1–C2 sublaminar wire in axial rotation.


  • Computed tomography of normal distal tibiofibular syndesmosis

    by Hossein Elgafy, Hassan B. Semaan, Brian Blessinger, Andrew Wassef, Nabil A. Ebraheim

    The purpose of this study was to determine the shape and measurements of the normal distal tibiofibular syndesmosis on computed tomographic scans and to identify features that could aid in the diagnosis of syndesmotic diastasis using computed tomography (CT).


    • 1 August 2009
      • Vol. 38  (8) , 410-6

    Treatment of displaced type II odontoid fractures in elderly patients.

    by Hossein Elgafy, Marcel F Dvorak, Alexander R Vaccaro, Nabil Ebraheim

    Odontoid fractures are the most common cervical spine fractures for patients older than 70 years and are the most common of all spinal fractures for patients older than 80. Type II fracture, the most common type of odontoid fracture, is considered relatively unstable. It occurs at the base of the odontoid between the level of the transverse ligament and the C2 vertebral body. In the geriatric population, it is important to look for any associated clinical comorbidities that might affect management. Treatment options for displaced odontoid fractures can be conservative or surgical. Conservative management includes immobilization in a cervical collar or in a halo vest. External immobilization with a cervical collar has had inconsistent results. Halo vest immobilization in the elderly is associated with a significant nonunion rate and several complications. Generally accepted surgical indications are polytrauma, neurologic deficit, associated unstable subaxial spine injury that requires surgical fixation, and symptomatic nonunion. Surgical management includes either anterior odontoid screw fixation or posterior C1-C2 instrumentation with fusion.


  • Three-Column Ligamentous Extension Injury of the Thoracic Spine

    by Hossein Elgafy, Carlo Bellabarba

    This is a report of a patient with a rare unstable 3-column ligamentous injury of the thoracic spine. To illustrate a rare unstable thoracic spine injury that required internal fixation despite its potentially benign clinical and radiologic presentation. Extension injury of the thoracolumbar spine is uncommon. Although there have been several reports of hyperextension injuries in the thoracolumbar spine, the radiologic findings of the present case was different from those in the previously reported cases. The clinical findings, roentgenographic appearance, treatment, were presented and the mechanism of this lesion was analyzed. Physical examination revealed mild weakness in his left hip flexor and quadriceps, ASIA-D motor score of 96. There was no tenderness or step deformity on assessment of his back. The initial roentgenograms showed no evidence of fracture or malalignment. However, evaluation of his computed tomography scan axial images showed a lateral superior endplate fracture, small fracture fragment from T11 right inferior articular process, widening of the left facet joint, and deformed T11 spinous process. The computed tomography scan sagittal images showed a vertical fracture fragment in the central spinal canal. The fragment may have arisen from the posterior cortex of the vertebral body, possibly due to elevation of the PLL. Magnetic resonance imaging (MRI) was obtained due to the suspicion that a much more severe underlying injury was present. The MRI demonstrated disc disruption and high intensity signals in the region of ALL, PLL, ligamentum flavum, supraspinous, and interspinous ligaments as well as in the spinal cord at T11-T12. The MRI also showed high intensity signals in the facet joints at T11-T12. Intraoperative assessment confirmed disruption of the supraspinous and interspinous ligaments, facet capsules and the ligamentum flavum, which was avulsed from its insertion on the underside of the T11 lamina on both sides. There was a tendency during the procedure of the spine to hyperextend, and "fish mouth" at the T11-T12 level, which confirmed the likelihood of this being an extension mechanism. The patient was treated with single segment posterior spine decompression, instrumentation, and fusion. A high index of suspicion is necessary to identify such extremely unstable injury despite its relative benign clinical and radiologic presentation.