ABAtul Bansal

Atul Bansal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Atul Bansal has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Extension of Retracted Glaucoma Drainage Tube Using a 22-gauge Intravenous Catheter in Complex Pediatric Glaucoma

    by Atul Bansal, Cecilia H. Fenerty

    To describe the use of the readily available, sterile, and economical 22-gauge intravenous catheter (Venflon) as a preferable option for extending the tube of glaucoma drainage devices in cases of tube retraction in complex pediatric cases. A report of noncomparative retrospective evaluation of 2 pediatric cases with tube retraction treated with the extension of the tube. The tube of the drainage devices (1 Baerveldt and 1 Molteno) was extended using a segment of a 22-gauge intravenous catheter (Venflon). The available follow-up for both the cases is 8.5 months. In both cases an adequate length of the tube was obtained in the anterior chamber. In the first case an excellent drainage bleb formed over the plate and the intraocular pressure (IOP) reduced from 28 to 11 mm Hg. In the second case only a 25% reduction of IOP (from 40 to 30 mm Hg) and a shallow bleb was seen for a few weeks only as extensive fibrosis over the plate limited the drainage. There has been no displacement of the tube in the follow-up period. The readily available, sterile, and economical 22-gauge intravenous catheter (venflon) segment is a structurally and functionally appropriate, and cost effective option for extension of both Baerveldt and Molteno drainage implants in complex pediatric cases. However other factors limiting drainage from tube, such as extensive scarring over the plate may limit the reduction of IOP.


  • Open Access

    Practical approach to medical management of glaucoma

    by Atul Bansal, Cecilia H Fenerty


  • Open Access

    Ocular decompression retinopathy after trabeculectomy with mitomycin-C for angle recession glaucoma

    by Atul Bansal, Us Ramanathan

    A 45-year-old male presented with intractable glaucoma following 360-degree angle recession after blunt trauma. He underwent an uncomplicated trabeculectomy with mitomycin-C (MMC). Adequate precautions were taken to reduce the chances of sudden lowering of intraocular pressure (IOP). He did not have any intraoperative shallowing of the anterior chamber or postoperative hypotony, but still developed ocular decompression retinopathy. On detailed review of the previously reported cases we discovered that besides a large IOP drop after surgery, either the preoperative rise of IOP in all these cases was over a relatively short period or the course of their glaucomatous process was likely to have exposed them to intermittent spikes of high IOP. To our knowledge this factor has not been previously postulated in the pathophysiology of ocular decompression retinopathy. We illustrate this with a rare case of ocular decompression retinopathy after trabeculectomy with MMC for post-traumatic angle recession glaucoma.


  • Potential Contamination of the G-probe Used for Transscleral Cyclodiode

    by Atul Bansal, Uthaya S. Ramanathan

    To present a case where we noted occult contamination of the G-probe used for transscleral cyclodiode and to critically analyze the techniques used for making a G-probe suitable for repeated use. Close microscopic examination of the G-probes used once for transscleral cyclodiode was done and a critical review of the literature on practice of reuse of the G-probe and the techniques used to "cleanse" the probe before reuse was performed. We noticed microscopic contamination of the G-probe by the tear film fluid in all the probes examined by us. The review of literature indicates that repeated use of the G-probe is not uncommon. The types of techniques used for making it suitable for repeated use indicate that it is not universally recognized that the lumen of the G-probe can accumulate fluid during the procedure, which makes it potentially hazardous when used for other patients. In our opinion the G-probe should not be reused as inadequately reprocessed G-probe can lead to risk of nosocomial infections, serious iatrogenic complications, and medico-legal problems.