Domenico Zito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Domenico Zito has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Domenico Pepe
Marconi Lab, Tyndall National Institute, Lee Maltings, Dyke Parade, Cork, Ireland
8 shared publications B. Neri
Radio-Frequency and Microwave Integrated Circuits Laboratory (RFLab) Dept. of Information Engineering (DIIEIT), University of Pisa, I-56122 Pisa, Italy
5 shared publications- Antonio Lanata
Department of Information Engineering, University of Florence, Florence, Italy
4 shared publications - Alessandro Tognetti
Department of Information Engineering, University of Pisa, Pisa, Italy
3 shared publications Bruno Neri
Radio-frequency and Microwave Integrated Circuits Laboratory (RFLab), Department of Information Engineering (DIIEIT), University of Pisa, Via Caruso 16, 56122 Pisa, Italy
3 shared publicationsA. Fonte
Radio-Frequency and Microwave Integrated Circuits Laboratory (RFLab) Dept. of Information Engineering (DIIEIT), University of Pisa, I-56122 Pisa, Italy
2 shared publications
Latest Publications
- 1 January 2011
- Published by Institution of Engineering and Technology (IET)
Ku band LC-active 90nm CMOS VCO
- 1 January 2011
- Published by Institution of Engineering and Technology (IET)
Ku band LC-active 90nm CMOS VCO
- 28 April 2009
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 38 (1) , 69-84
LC‐active VCO for CMOS RF transceivers
A novel fully integrated CMOS LC tank VCO is presented. The LC tanks are implemented by exploiting the active circuit ‘boot‐strapped inductor’ (BSI), which behaves like a high‐quality factor inductor. Particularly, the LC tanks have been implemented by introducing a new version of the CMOS BSI circuit, which provides better versatility and design reliability.In order to verify the effectiveness of such an approach, a case study for 5–6 GHz direct‐conversion multi‐standard WLAN transceivers is presented. The VCO has been designed in a 0.35µm standard CMOS technology. The new BSI exhibits a high‐quality factor (higher than 25 over the all frequency range) and provides a high selectivity without introducing a relevant excess of noise, for a better spectral purity and a lower phase noise (PN) of the VCO. The overall VCO circuit consumes 9 mW. The VCO produces an oscillation in the tuning range from 4.91 to 5.93 GHz (nearly equal to 19%). The circuit exhibits a PN of −129dBc/Hz at 1 MHz of frequency offset from the central frequency (5.4 GHz) and a FOM equal to 189.5 dBc/Hz at 100 kHz and 194.1 dBc/Hz at 1 MHz of frequency offset, respectively. Copyright © 2009 John Wiley & Sons, Ltd.
- 28 April 2009
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 38 (1) , 69-84
LC‐active VCO for CMOS RF transceivers
A novel fully integrated CMOS LC tank VCO is presented. The LC tanks are implemented by exploiting the active circuit ‘boot‐strapped inductor’ (BSI), which behaves like a high‐quality factor inductor. Particularly, the LC tanks have been implemented by introducing a new version of the CMOS BSI circuit, which provides better versatility and design reliability.In order to verify the effectiveness of such an approach, a case study for 5–6 GHz direct‐conversion multi‐standard WLAN transceivers is presented. The VCO has been designed in a 0.35µm standard CMOS technology. The new BSI exhibits a high‐quality factor (higher than 25 over the all frequency range) and provides a high selectivity without introducing a relevant excess of noise, for a better spectral purity and a lower phase noise (PN) of the VCO. The overall VCO circuit consumes 9 mW. The VCO produces an oscillation in the tuning range from 4.91 to 5.93 GHz (nearly equal to 19%). The circuit exhibits a PN of −129dBc/Hz at 1 MHz of frequency offset from the central frequency (5.4 GHz) and a FOM equal to 189.5 dBc/Hz at 100 kHz and 194.1 dBc/Hz at 1 MHz of frequency offset, respectively. Copyright © 2009 John Wiley & Sons, Ltd.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 5274-5277
Wearable system-on-a-chip UWB radar for contact-less cardiopulmonary monitoring: Present status
The present status of the project aimed at the realization of an innovative wearable system-on-chip UWB radar for the cardiopulmonary monitoring is presented. The overall system consists of a wearable wireless interface including a fully integrated UWB radar for the detection of the heart beat and breath rates, and a IEEE 802.15.4 ZigBee low-power radio interface. The principle of operation of the UWB radar for the monitoring of the heart wall is summarized. With respect to the prior art, this paper reports the results of the experimental characterization of the intra-body channel loss, which has been carried out successfully in order to validate the theoretical model employed for the radar system analysis. Moreover, the main building blocks of the radar have been manufactured in 90 nm CMOS technology by ST-Microelectronics and the relevant performance are resulted in excellent agreement with those expected by post-layout simulations.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 5274-5277
Wearable system-on-a-chip UWB radar for contact-less cardiopulmonary monitoring: Present status
The present status of the project aimed at the realization of an innovative wearable system-on-chip UWB radar for the cardiopulmonary monitoring is presented. The overall system consists of a wearable wireless interface including a fully integrated UWB radar for the detection of the heart beat and breath rates, and a IEEE 802.15.4 ZigBee low-power radio interface. The principle of operation of the UWB radar for the monitoring of the heart wall is summarized. With respect to the prior art, this paper reports the results of the experimental characterization of the intra-body channel loss, which has been carried out successfully in order to validate the theoretical model employed for the radar system analysis. Moreover, the main building blocks of the radar have been manufactured in 90 nm CMOS technology by ST-Microelectronics and the relevant performance are resulted in excellent agreement with those expected by post-layout simulations.
- 11 July 2008
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 37 (9) , 1008-1018
A novel low‐power receiver topology for RF and microwave applications
A novel low‐power receiver topology for radio‐frequency and microwave applications is presented. The proposed solution exploits a simple connection between the low‐noise amplifier and the subsequent mixer, which is realized by means of a high‐value resistor and a current mirror, achieving low noise and high linearity performance with an extremely low power consumption. The criteria for its optimal design are derived in order to accomplish the main trade‐offs among noise figure (NF), linearity, and current consumption performance.As a case of study, the new topology has been designed in the case ofI/Qdirect conversion receiver for IEEE 802.15.4 standard (ZigBee) applications at 2.45 GHz. The receiver exhibits a NF of 8.7 dB, 50Ω input impedance, a voltage gain of 26 dB, an input‐referred third‐order intercept point of −13 dBm, and a power consumption of 8.6 mW, which represent one of the best performance trade‐offs obtained in the literature. Copyright © 2008 John Wiley & Sons, Ltd.
- 11 July 2008
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 37 (9) , 1008-1018
A novel low‐power receiver topology for RF and microwave applications
A novel low‐power receiver topology for radio‐frequency and microwave applications is presented. The proposed solution exploits a simple connection between the low‐noise amplifier and the subsequent mixer, which is realized by means of a high‐value resistor and a current mirror, achieving low noise and high linearity performance with an extremely low power consumption. The criteria for its optimal design are derived in order to accomplish the main trade‐offs among noise figure (NF), linearity, and current consumption performance.As a case of study, the new topology has been designed in the case ofI/Qdirect conversion receiver for IEEE 802.15.4 standard (ZigBee) applications at 2.45 GHz. The receiver exhibits a NF of 8.7 dB, 50Ω input impedance, a voltage gain of 26 dB, an input‐referred third‐order intercept point of −13 dBm, and a power consumption of 8.6 mW, which represent one of the best performance trade‐offs obtained in the literature. Copyright © 2008 John Wiley & Sons, Ltd.
- Open Access
- 1 January 2008
- Published by Hindawi Limited in International Journal of Telemedicine and Applications
- Vol. 2008, 1-10
Feasibility Study and Design of a Wearable System-on-a-Chip Pulse Radar for Contactless Cardiopulmonary Monitoring
A new system-on-a-chip radar sensor for next-generation wearable wireless interface applied to the human health care and safeguard is presented. The system overview is provided and the feasibility study of the radar sensor is presented. In detail, the overall system consists of a radar sensor for detecting the heart and breath rates and a low-power IEEE 802.15.4 ZigBee radio interface, which provides a wireless data link with remote data acquisition and control units. In particular, the pulse radar exploits 3.1–10.6 GHz ultra-wideband signals which allow a significant reduction of the transceiver complexity and then of its power consumption. The operating principle of the radar for the cardiopulmonary monitoring is highlighted and the results of the system analysis are reported. Moreover, the results obtained from the building-blocks design, the channel measurement, and the ultra-wideband antenna realization are reported.
- 1 January 2008
- Published by Hindawi Limited in International Journal of Telemedicine and Applications
- Vol. 2008, 1-10
Open AccessFeasibility Study and Design of a Wearable System-on-a-Chip Pulse Radar for Contactless Cardiopulmonary Monitoring
A new system-on-a-chip radar sensor for next-generation wearable wireless interface applied to the human health care and safeguard is presented. The system overview is provided and the feasibility study of the radar sensor is presented. In detail, the overall system consists of a radar sensor for detecting the heart and breath rates and a low-power IEEE 802.15.4 ZigBee radio interface, which provides a wireless data link with remote data acquisition and control units. In particular, the pulse radar exploits 3.1–10.6 GHz ultra-wideband signals which allow a significant reduction of the transceiver complexity and then of its power consumption. The operating principle of the radar for the cardiopulmonary monitoring is highlighted and the results of the system analysis are reported. Moreover, the results obtained from the building-blocks design, the channel measurement, and the ultra-wideband antenna realization are reported.
- 1 December 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1340-1343
A Novel LNA Topology with Transformer-based Input Integrated Matching and its 60-GHz Millimeter-wave CMOS 65-nm Design
A novel LNA topology with a transformer-based input integrated matching is proposed and its application to the 60-GHz millimeter-wave design in bulk CMOS 65 nm technology is reported. This topology exploits a novel technique to realize the input integrated matching (simultaneous input impedance and minimum noise matching to the source resistance) in cascode amplifier. This new technique does not require the traditional inductive source (emitter) degeneration, which decreases the gain at high frequency and especially in the range of the millimeter waves. This new topology has been implemented as the first stage of a two-stage LNA. Post-layout simulations of the two-stage LNA show S11 of-16.84 dB at 61.45 GHz, and S21 equal to 10.02 dB at 60 GHz, NF equal to 8.68 dB at 60 GHz, input-referred CPidB equal to -13 dBm, with an associated overall power consumption of 18.5 mW.
- 1 December 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1340-1343
A Novel LNA Topology with Transformer-based Input Integrated Matching and its 60-GHz Millimeter-wave CMOS 65-nm Design
A novel LNA topology with a transformer-based input integrated matching is proposed and its application to the 60-GHz millimeter-wave design in bulk CMOS 65 nm technology is reported. This topology exploits a novel technique to realize the input integrated matching (simultaneous input impedance and minimum noise matching to the source resistance) in cascode amplifier. This new technique does not require the traditional inductive source (emitter) degeneration, which decreases the gain at high frequency and especially in the range of the millimeter waves. This new topology has been implemented as the first stage of a two-stage LNA. Post-layout simulations of the two-stage LNA show S11 of-16.84 dB at 61.45 GHz, and S21 equal to 10.02 dB at 60 GHz, NF equal to 8.68 dB at 60 GHz, input-referred CPidB equal to -13 dBm, with an associated overall power consumption of 18.5 mW.
- 1 December 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 613-616
Advanced Model and RF-CMOS Design of the Boot-Strapped Inductor
This paper reports a new advanced design of the active circuit named boot-strapped inductor (BSI), which realizes an equivalent inductor with an high quality factor (Q). In particular, a new small-signal circuit model is proposed for an accurate design at high frequency in a modern RF CMOS process, also by taking into account the issues of an algorithmic and low-power consumption circuit design. A case study for 13-GHz low-power applications by using a standard for 90 nm CMOS process is reported. The BSI provides an equivalent inductance close to 1.6 nH with an associated quality factor Q close to 200.
- 1 December 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 613-616
Advanced Model and RF-CMOS Design of the Boot-Strapped Inductor
This paper reports a new advanced design of the active circuit named boot-strapped inductor (BSI), which realizes an equivalent inductor with an high quality factor (Q). In particular, a new small-signal circuit model is proposed for an accurate design at high frequency in a modern RF CMOS process, also by taking into account the issues of an algorithmic and low-power consumption circuit design. A case study for 13-GHz low-power applications by using a standard for 90 nm CMOS process is reported. The BSI provides an equivalent inductance close to 1.6 nH with an associated quality factor Q close to 200.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 2651-2654
Wearable System-on-a-Chip UWB Radar for Health Care and its Application to the Safety Improvement of Emergency Operators
A new wearable system-on-a-chip UWB radar for health care systems is presented. The idea and its applications to the safety improvement of emergency operators are discussed. The system consists of a wearable wireless interface including a fully integrated UWB radar for the detection of the heart beat and breath rates, and a IEEE 802.15.4 ZigBee radio interface. The principle of operation of the UWB radar for the monitoring of the heart wall is explained hereinafter. The results obtained by the feasibility study regarding its implementation on a modern standard silicon technology (CMOS 90 nm) are reported, demonstrating (at simulation level) the effectiveness of such an approach and enabling the standard silicon technology for new generations of wireless sensors for heath care and safeguard wearable systems.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 2651-2654
Wearable System-on-a-Chip UWB Radar for Health Care and its Application to the Safety Improvement of Emergency Operators
A new wearable system-on-a-chip UWB radar for health care systems is presented. The idea and its applications to the safety improvement of emergency operators are discussed. The system consists of a wearable wireless interface including a fully integrated UWB radar for the detection of the heart beat and breath rates, and a IEEE 802.15.4 ZigBee radio interface. The principle of operation of the UWB radar for the monitoring of the heart wall is explained hereinafter. The results obtained by the feasibility study regarding its implementation on a modern standard silicon technology (CMOS 90 nm) are reported, demonstrating (at simulation level) the effectiveness of such an approach and enabling the standard silicon technology for new generations of wireless sensors for heath care and safeguard wearable systems.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 5715-5718
Wearable System-on-a-Chip Radiometer for Remote Temperature Sensing and its Application to the Safeguard of Emergency Operators
The remote sensing and the detection of events that may represent a danger for human beings have become more and more important thanks to the latest advances of the technology. A microwave radiometer is a sensor capable to detect a fire or an abnormal increase of the internal temperature of the human body (hyperthermia), or an onset of a cancer, or even meteorological phenomena (forest fires, pollution release, ice formation on road pavement). In this paper, the overview of a wearable low-cost low-power system-on-a-chip (SoaC) 13 GHz passive microwave radiometer in CMOS 90 nm technology is presented. In particular, we focused on its application to the fire detection for civil safeguard. In detail, this sensor has been thought to be inserted into the fireman jacket in order to help the fireman in the detection of a hidden fire behind a door or a wall. The simulation results obtained by Ptolemy system simulation have confirmed the feasibility of such a SoaC microwave radiometer in a low-cost standard silicon technology for temperature remote sensing and, in particular, for its application to the safeguard of emergency operators.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 5715-5718
Wearable System-on-a-Chip Radiometer for Remote Temperature Sensing and its Application to the Safeguard of Emergency Operators
The remote sensing and the detection of events that may represent a danger for human beings have become more and more important thanks to the latest advances of the technology. A microwave radiometer is a sensor capable to detect a fire or an abnormal increase of the internal temperature of the human body (hyperthermia), or an onset of a cancer, or even meteorological phenomena (forest fires, pollution release, ice formation on road pavement). In this paper, the overview of a wearable low-cost low-power system-on-a-chip (SoaC) 13 GHz passive microwave radiometer in CMOS 90 nm technology is presented. In particular, we focused on its application to the fire detection for civil safeguard. In detail, this sensor has been thought to be inserted into the fireman jacket in order to help the fireman in the detection of a hidden fire behind a door or a wall. The simulation results obtained by Ptolemy system simulation have confirmed the feasibility of such a SoaC microwave radiometer in a low-cost standard silicon technology for temperature remote sensing and, in particular, for its application to the safeguard of emergency operators.