Jorge Miguel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jorge Miguel has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Wolfgang Kuch
Freie Universität Berlin
2 shared publications C. Tieg
Max-Planck-Institut für Mikrostrukturphysik, Weinberg 2, D-06120 Halle, Germany
1 shared publicationDaniela Bayer
University of Kaiserslautern 2 Fachbereich Physik Erwin-Schrödinger-Straße 46, D-67663 Kaiserslautern, Germany
1 shared publication- Florian Kronast
Helmholtz‐Zentrum Berlin für Materialien und Energie Berlin Germany
1 shared publication Hermann A. Dürr
BESSY GmbH 3 , Albert-Einstein-Straße 15, D-12489 Berlin, Germany
1 shared publicationJ. B. Goedkoop
Van der Waals-Zeeman Institute, University of Amsterdam, Valckenierstraat 65, 1018 XE, Amsterdam, the Netherlands
1 shared publication
Latest Publications
- 1 March 2008
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 79 (3) , 033702
A new sample holder for laser-excited pump-probe magnetic measurements on a Focus photoelectron emission microscope
A custom-made Omicron-compatible sample holder for time-resolved photoelectron emission microscopy experiments is presented. It comprises a sample plate with four contacts that hosts a chip carrier where the semiconductor substrate is mounted. Covering the sample holder, a 6mm diameter mask protects electrostatically the sample from the extractor lens voltage while keeping the imaging quality unperturbed. The improvements are a greater sample lifetime and the ability to withstand much higher currents in the stripline that provides the magnetic pulse to the magnetic microstructure.
- 1 March 2008
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 79 (3) , 033702
A new sample holder for laser-excited pump-probe magnetic measurements on a Focus photoelectron emission microscope
A custom-made Omicron-compatible sample holder for time-resolved photoelectron emission microscopy experiments is presented. It comprises a sample plate with four contacts that hosts a chip carrier where the semiconductor substrate is mounted. Covering the sample holder, a 6mm diameter mask protects electrostatically the sample from the extractor lens voltage while keeping the imaging quality unperturbed. The improvements are a greater sample lifetime and the ability to withstand much higher currents in the stripline that provides the magnetic pulse to the magnetic microstructure.
- 10 January 2008
- Published by American Physical Society (APS) in Physical Review B
- Vol. 77 (1) , 014411
Structural and magnetic properties of epitaxialbilayers on Ag(001)We have investigated the magnetic coupling between a metallic ferromagnet and an oxidic antiferromagnet in epitaxial single-crystalline bilayers on Ag(001) using x-ray absorption spectroscopy. Absorption spectra taken from bilayers with different amounts of deposited Fe show only a weak indication for the formation of Fe oxide at the interface. From the spectral shape, it is concluded that an FeO type of oxide is formed. X-ray magnetic circular dichroism (XMCD) measurements exhibit a sizable induced ferromagnetic signal at the absorption edges, corresponding to an interface layer of 1.1 ML of CoO in which the Co magnetic moments couple with the Fe moments. The angular dependence of the Fe XMCD and Co x-ray magnetic linear dichroic signals at the edges shows that the orientation of the Co and Fe spins is parallel along the crystallographic ⟨110⟩ directions.- 10 January 2008
- Published by American Physical Society (APS) in Physical Review B
- Vol. 77 (1) , 014411
Structural and magnetic properties of epitaxialbilayers on Ag(001)We have investigated the magnetic coupling between a metallic ferromagnet and an oxidic antiferromagnet in epitaxial single-crystalline bilayers on Ag(001) using x-ray absorption spectroscopy. Absorption spectra taken from bilayers with different amounts of deposited Fe show only a weak indication for the formation of Fe oxide at the interface. From the spectral shape, it is concluded that an FeO type of oxide is formed. X-ray magnetic circular dichroism (XMCD) measurements exhibit a sizable induced ferromagnetic signal at the absorption edges, corresponding to an interface layer of 1.1 ML of CoO in which the Co magnetic moments couple with the Fe moments. The angular dependence of the Fe XMCD and Co x-ray magnetic linear dichroic signals at the edges shows that the orientation of the Co and Fe spins is parallel along the crystallographic ⟨110⟩ directions.- 29 September 2006
- Published by American Physical Society (APS) in Physical Review B
- Vol. 74 (9) , 094437
X-ray resonant magnetic scattering study of magnetic stripe domains inthin filmsX-ray resonant magnetic scattering (XRMS) has been used to investigate the structure of magnetic stripe domain patterns in thin amorphous GdFe films. Under the influence of a perpendicular magnetic field, the scattered intensity displays a smooth transition from a structure factor of correlated stripes to the form factor of isolated domains. We derive a quite general expression that relates the total scattered intensity of XRMS to the absolute value of the magnetization. Furthermore, we compare our results for the domain period with domain theory. We obtain good agreement for prealigned stripes, but disorder tends to lead to an overestimation of the period measured with XRMS.
- 29 September 2006
- Published by American Physical Society (APS) in Physical Review B
- Vol. 74 (9) , 094437
X-ray resonant magnetic scattering study of magnetic stripe domains inthin filmsX-ray resonant magnetic scattering (XRMS) has been used to investigate the structure of magnetic stripe domain patterns in thin amorphous GdFe films. Under the influence of a perpendicular magnetic field, the scattered intensity displays a smooth transition from a structure factor of correlated stripes to the form factor of isolated domains. We derive a quite general expression that relates the total scattered intensity of XRMS to the absolute value of the magnetization. Furthermore, we compare our results for the domain period with domain theory. We obtain good agreement for prealigned stripes, but disorder tends to lead to an overestimation of the period measured with XRMS.