Rodolfo Laucirica
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rodolfo Laucirica has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Ann T. Moriarty
Department of Pathology, AmeriPath Indiana, Indianapolis, IN 46219-1739, USA
3 shared publications Beth Anne Chmara
3 shared publicationsAmy C. Clayton
2 shared publicationsAnn T. Moriarty
2 shared publicationsDeborah R. Citron
Department of Pathology and Immunology Baylor College of Medicine Houston Texas
2 shared publicationsJoel S. Bentz
2 shared publications
Latest Publications
- 3 January 2013
- Published by Wiley in Diagnostic Cytopathology
- Vol. 41 (8) , 697-702
Anal cytology as a predictor of anal intraepithelial neoplasia in HIV‐positive men and women
Human immunodeficiency virus (HIV)‐infected individuals have increased risk of anal intraepithelial neoplasia (AIN) and squamous cell carcinoma (SCC). Cytologic screening is invaluable in the detection of cervical neoplasia, therefore many clinicians have adopted anal cytology as part of anal cancer screening in patients at high‐risk for anal neoplasia. The purpose of this study is to determine whether anal cytology is a valuable screening test for identifying AIN in HIV+ patients. The cohort included 228 HIV+ patients who underwent anal cancer screening with collection of 318 anal cytology specimens between January 2006 and December 2009. Of this group, 74 (32.5%) patients had associated anal biopsies within a 6‐month period, with a total of 89 comparison cases. The anal cytology samples were classified using the 2001 Bethesda System terminology. The sensitivity of anal cytology in detecting ASC‐US, AIN 1‐3 or SCC was 93%. Cytology was 88% sensitive for detecting low‐grade AIN (AIN 1), but only 20% sensitive for detecting high‐grade AIN (AIN 2–3) or SCC. Atypical squamous cells of undetermined significance cases were distributed evenly between low‐ and high‐grade AIN, with two cases having normal histology. Only six cases had negative cytology, all of which were associated with AIN on biopsy, for a false negative rate of 7%. Anal cytology is a good predictor of AIN, as confirmed by the high degree of sensitivity. However, there is poor correlation between the cytological and histological grade of AIN. Cytology underestimates the grade of dysplasia compared to the corresponding biopsy. Diagn. Cytopathol. 2013;41:697–702.
- 3 January 2013
- Published by Wiley in Diagnostic Cytopathology
- Vol. 41 (8) , 697-702
Anal cytology as a predictor of anal intraepithelial neoplasia in HIV‐positive men and women
Human immunodeficiency virus (HIV)‐infected individuals have increased risk of anal intraepithelial neoplasia (AIN) and squamous cell carcinoma (SCC). Cytologic screening is invaluable in the detection of cervical neoplasia, therefore many clinicians have adopted anal cytology as part of anal cancer screening in patients at high‐risk for anal neoplasia. The purpose of this study is to determine whether anal cytology is a valuable screening test for identifying AIN in HIV+ patients. The cohort included 228 HIV+ patients who underwent anal cancer screening with collection of 318 anal cytology specimens between January 2006 and December 2009. Of this group, 74 (32.5%) patients had associated anal biopsies within a 6‐month period, with a total of 89 comparison cases. The anal cytology samples were classified using the 2001 Bethesda System terminology. The sensitivity of anal cytology in detecting ASC‐US, AIN 1‐3 or SCC was 93%. Cytology was 88% sensitive for detecting low‐grade AIN (AIN 1), but only 20% sensitive for detecting high‐grade AIN (AIN 2–3) or SCC. Atypical squamous cells of undetermined significance cases were distributed evenly between low‐ and high‐grade AIN, with two cases having normal histology. Only six cases had negative cytology, all of which were associated with AIN on biopsy, for a false negative rate of 7%. Anal cytology is a good predictor of AIN, as confirmed by the high degree of sensitivity. However, there is poor correlation between the cytological and histological grade of AIN. Cytology underestimates the grade of dysplasia compared to the corresponding biopsy. Diagn. Cytopathol. 2013;41:697–702.
- 1 December 2011
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 135 (12) , 1533-1538
Performance Characteristics of Mucinous (Colloid) Carcinoma of the Breast in Fine-Needle Aspirates: Observations From the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology
Context .—Mucinous breast carcinoma has characteristic cytologic features, but few studies exist that analyze the reproducibility of this diagnosis. Objective .—To analyze participants' diagnosis of mucinous carcinoma in breast fine-needle aspiration (FNA) slides distributed in an educational interlaboratory peer comparison program. Design .—Participant responses for FNA slides with a reference diagnosis of mucinous carcinoma, distributed between 2001–2008 in the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology, were evaluated for concordance with the general category and reference diagnosis of mucinous carcinoma. Results .—Of 8061 responses, 6353 (78.8%) were categorized as malignant; 775 (9.6%) as suspicious; and 933 (11.6%) as negative. The most frequent incorrect responses for the benign category included fibroadenoma (51.7%), nonspecified benign lesion (12%), fibrocystic changes (7.8%), and fat necrosis/granulomatosis/foreign body reaction (6.9%). Conventional Papanicolaou-stained preparations were reviewed for 58.7% (4732) of responses; of these, 39.4% (3177) were from modified Giemsa–stained smears and 1.9% (152) from ThinPrep slides. Papanicolaou-stained conventional smears had the lowest concordance (86.5%) when compared to modified Giemsa–stained smears (91.2%) and ThinPrep challenges (92.1%) ( P < .001). Participants specifically diagnosed mucinous carcinoma 37.3% of the time, and modified Giemsa–stained challenges performed best (43.1%, P < .001). There was no significant difference between cytotechnologists' and pathologists' responses (87.9% versus 88.2%; P = .69). Conclusions .—Mucinous carcinoma in FNA was not accurately identified in a glass slide interlaboratory comparison program. We observed better performance with modified Giemsa–stained and ThinPrep slides than with Papanicolaou-stained preparations. The most common response for the benign category of mucinous carcinoma was fibroadenoma. Increased awareness of the cytologic features of mucinous carcinoma may improve accuracy in breast FNA.
- 1 December 2011
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 135 (12) , 1533-1538
Performance Characteristics of Mucinous (Colloid) Carcinoma of the Breast in Fine-Needle Aspirates: Observations From the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology
Context .—Mucinous breast carcinoma has characteristic cytologic features, but few studies exist that analyze the reproducibility of this diagnosis. Objective .—To analyze participants' diagnosis of mucinous carcinoma in breast fine-needle aspiration (FNA) slides distributed in an educational interlaboratory peer comparison program. Design .—Participant responses for FNA slides with a reference diagnosis of mucinous carcinoma, distributed between 2001–2008 in the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology, were evaluated for concordance with the general category and reference diagnosis of mucinous carcinoma. Results .—Of 8061 responses, 6353 (78.8%) were categorized as malignant; 775 (9.6%) as suspicious; and 933 (11.6%) as negative. The most frequent incorrect responses for the benign category included fibroadenoma (51.7%), nonspecified benign lesion (12%), fibrocystic changes (7.8%), and fat necrosis/granulomatosis/foreign body reaction (6.9%). Conventional Papanicolaou-stained preparations were reviewed for 58.7% (4732) of responses; of these, 39.4% (3177) were from modified Giemsa–stained smears and 1.9% (152) from ThinPrep slides. Papanicolaou-stained conventional smears had the lowest concordance (86.5%) when compared to modified Giemsa–stained smears (91.2%) and ThinPrep challenges (92.1%) ( P < .001). Participants specifically diagnosed mucinous carcinoma 37.3% of the time, and modified Giemsa–stained challenges performed best (43.1%, P < .001). There was no significant difference between cytotechnologists' and pathologists' responses (87.9% versus 88.2%; P = .69). Conclusions .—Mucinous carcinoma in FNA was not accurately identified in a glass slide interlaboratory comparison program. We observed better performance with modified Giemsa–stained and ThinPrep slides than with Papanicolaou-stained preparations. The most common response for the benign category of mucinous carcinoma was fibroadenoma. Increased awareness of the cytologic features of mucinous carcinoma may improve accuracy in breast FNA.
- 1 January 2011
- Published by Wiley in Archives of Pathology & Laboratory Medicine
- Vol. 135 (1) , 12-8
The Texas Society of Pathologists: a historical perspective of the first 90 years.
- 1 January 2011
- Published by Wiley in Archives of Pathology & Laboratory Medicine
- Vol. 135 (1) , 12-8
The Texas Society of Pathologists: a historical perspective of the first 90 years.
- Open Access
- 1 January 2011
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 135 (1) , 12-18
The Texas Society of Pathologists: A Historical Perspective of the First 90 Years
- 1 January 2011
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 135 (1) , 12-18
Open AccessThe Texas Society of Pathologists: A Historical Perspective of the First 90 Years
- 1 December 2010
- Published by Wiley in Archives of Pathology & Laboratory Medicine
- Vol. 134 (12) , 1793-6
Granulomatous inflammation-an underestimated cause of false-positive diagnoses in lung fine-needle aspirates: observations from the college of american pathologists nongynecologic cytopathology interlaboratory comparison program.
The false-positive rate for fine-needle aspirates of the lung has been cited as less than 1% for granulomatous inflammation, comprising one of the known causes of false-positive diagnoses. To determine the rate of false-positive diagnoses of granulomatous inflammation for lung fine-needle aspirates by assessing the false-positive response rate in the context of the College of American Pathologists Nongynecologic Cytopathology Interlaboratory Comparison Program. We performed a retrospective review of 1092 participant responses for lung fine-needle aspirate challenges with the reference diagnosis of specific infections/granulomatous inflammation from 1998 to 2008 from the College of American Pathologists Nongynecologic Cytopathology Interlaboratory Comparison Program. False-positive rates by participant type (pathologist versus cytotechnologist), general diagnosis category, reference diagnosis, and preparation type were analyzed for the pathologists' responses. Of the 502 general category responses for pathologists, 428 (85.3%) were benign, 55 (11%) were malignant, and 19 (3.8%) were suspicious. There was no difference in the false-positive rate between preparations (P = .76) or participants (P = .39). Of those responses by pathologists that were benign, only 68.7% (292 of 425) were an exact match to granulomatous inflammation. Non-small cell carcinoma, adenocarcinoma, and squamous carcinoma represented 64% of false-positive/suspicious responses, while small cell carcinoma and carcinoid comprised 13%. In an interlaboratory comparison program, granulomatous inflammation represents an important cause of false-positive/suspicious responses in lung fine-needle aspirates (14.8%) and is much higher than false-positive rates reported historically in clinical studies. These results highlight the importance of granulomatous inflammation as a mimic of carcinoma.
- 1 December 2010
- Published by Wiley in Archives of Pathology & Laboratory Medicine
- Vol. 134 (12) , 1793-6
Granulomatous inflammation-an underestimated cause of false-positive diagnoses in lung fine-needle aspirates: observations from the college of american pathologists nongynecologic cytopathology interlaboratory comparison program.
The false-positive rate for fine-needle aspirates of the lung has been cited as less than 1% for granulomatous inflammation, comprising one of the known causes of false-positive diagnoses. To determine the rate of false-positive diagnoses of granulomatous inflammation for lung fine-needle aspirates by assessing the false-positive response rate in the context of the College of American Pathologists Nongynecologic Cytopathology Interlaboratory Comparison Program. We performed a retrospective review of 1092 participant responses for lung fine-needle aspirate challenges with the reference diagnosis of specific infections/granulomatous inflammation from 1998 to 2008 from the College of American Pathologists Nongynecologic Cytopathology Interlaboratory Comparison Program. False-positive rates by participant type (pathologist versus cytotechnologist), general diagnosis category, reference diagnosis, and preparation type were analyzed for the pathologists' responses. Of the 502 general category responses for pathologists, 428 (85.3%) were benign, 55 (11%) were malignant, and 19 (3.8%) were suspicious. There was no difference in the false-positive rate between preparations (P = .76) or participants (P = .39). Of those responses by pathologists that were benign, only 68.7% (292 of 425) were an exact match to granulomatous inflammation. Non-small cell carcinoma, adenocarcinoma, and squamous carcinoma represented 64% of false-positive/suspicious responses, while small cell carcinoma and carcinoid comprised 13%. In an interlaboratory comparison program, granulomatous inflammation represents an important cause of false-positive/suspicious responses in lung fine-needle aspirates (14.8%) and is much higher than false-positive rates reported historically in clinical studies. These results highlight the importance of granulomatous inflammation as a mimic of carcinoma.
- 22 November 2010
- Published by Wiley in Diagnostic Cytopathology
- Vol. 39 (10) , 780-783
Myxoid liposarcoma: A case report of a sentinel metastasis to the parotid gland with molecular confirmation
Myxoid liposarcoma is a subtype of liposarcoma with a predilection for the deep soft tissues of the extremities that accounts approximately for 10% of all adult soft tissue sarcomas. We report a case of a metastatic myxoid liposarcoma to the parotid gland, with fine‐needle aspiration cytology correlation and molecular characterization. The lesion was diagnosed in a 53‐year‐old Hispanic male who presented with a left posterior thigh mass. A core needle biopsy established the diagnosis of myxoid liposarcoma. The patient underwent limb‐sparing, wide local excision of the malignancy and later presented with an initial metastatic lesion to the parotid gland. The diagnosis of metastatic myxoid liposarcoma was rendered by fine‐needle aspiration cytology with cell block preparation, and molecular confirmation. Although myxoid/round cell liposarcomas are classically described as having minimal pleomorphism on cytologic material, we encountered significant pleomorphism in our case. Therefore, a diagnosis of myxoid/round cell liposarcoma should still be a diagnostic consideration even if markedly pleomorphic cells are seen in fine‐needle aspiration biopsies. Diagn. Cytopathol. 2010.
- 22 November 2010
- Published by Wiley in Diagnostic Cytopathology
- Vol. 39 (10) , 780-783
Myxoid liposarcoma: A case report of a sentinel metastasis to the parotid gland with molecular confirmation
Myxoid liposarcoma is a subtype of liposarcoma with a predilection for the deep soft tissues of the extremities that accounts approximately for 10% of all adult soft tissue sarcomas. We report a case of a metastatic myxoid liposarcoma to the parotid gland, with fine‐needle aspiration cytology correlation and molecular characterization. The lesion was diagnosed in a 53‐year‐old Hispanic male who presented with a left posterior thigh mass. A core needle biopsy established the diagnosis of myxoid liposarcoma. The patient underwent limb‐sparing, wide local excision of the malignancy and later presented with an initial metastatic lesion to the parotid gland. The diagnosis of metastatic myxoid liposarcoma was rendered by fine‐needle aspiration cytology with cell block preparation, and molecular confirmation. Although myxoid/round cell liposarcomas are classically described as having minimal pleomorphism on cytologic material, we encountered significant pleomorphism in our case. Therefore, a diagnosis of myxoid/round cell liposarcoma should still be a diagnostic consideration even if markedly pleomorphic cells are seen in fine‐needle aspiration biopsies. Diagn. Cytopathol. 2010.
- 1 August 2010
- Published by Wiley in Archives of Pathology & Laboratory Medicine
- Vol. 134 (8) , 1116-20
Comparison of ThinPrep preparations to other preparation types in gastrointestinal cytology: observations from the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology.
Differences in participant responses for ThinPrep (TP) and non-ThinPrep (NTP) preparations for gastrointestinal cytology challenges, which circulated in the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology (CAP NGC), may help to identify performance variations between preparation types. To compare the performance of TP-prepared slides of gastrointestinal exfoliative cytology specimens to that of NTP preparations in the CAP NGC program. Participant responses between 2000 and 2007 were evaluated for esophageal wash/brush, gastric wash/brush, and biliary tract brush specimens with a reference diagnosis of adenocarcinoma, squamous cell carcinoma, carcinoid, or spindle cell neoplasm. ThinPrep challenges were compared with NTP preparations (conventional smears, cytospins) for discordant responses. In all, 6023 pathologist responses and 3825 cytotechnologist responses were reviewed. Non-ThinPrep preparations comprised 93% (n = 11 588) of the challenges, while 7% (n = 912) were TP material. A match for a "positive/suspicious" diagnosis was seen in 88.5% of NTP and 95.9% of TP preparations (P < .001). These results were statistically significant when the specific reference diagnosis was adenocarcinoma (P < .001). Overall performance of cytotechnologists was not different from that of pathologists (89.2% versus 89.0%; P = .75). Cytotechnologists had better performance for detecting squamous cell carcinoma (96.3% versus 92.6%; P < .001), while pathologists had better performance for detecting spindle cell neoplasm (79.7% versus 42.9%; P < .001). ThinPrep preparations performed significantly better than NTP preparations in gastrointestinal cytology specimens circulated in an interlaboratory comparison program. Performance varied by reference interpretation, with the best performance for the interpretation of adenocarcinoma. Cytotechnologists and pathologists performed at the same level overall, but with differences for the diagnosis of spindle cell neoplasm and squamous carcinoma.
- 1 August 2010
- Published by Wiley in Archives of Pathology & Laboratory Medicine
- Vol. 134 (8) , 1116-20
Comparison of ThinPrep preparations to other preparation types in gastrointestinal cytology: observations from the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology.
Differences in participant responses for ThinPrep (TP) and non-ThinPrep (NTP) preparations for gastrointestinal cytology challenges, which circulated in the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology (CAP NGC), may help to identify performance variations between preparation types. To compare the performance of TP-prepared slides of gastrointestinal exfoliative cytology specimens to that of NTP preparations in the CAP NGC program. Participant responses between 2000 and 2007 were evaluated for esophageal wash/brush, gastric wash/brush, and biliary tract brush specimens with a reference diagnosis of adenocarcinoma, squamous cell carcinoma, carcinoid, or spindle cell neoplasm. ThinPrep challenges were compared with NTP preparations (conventional smears, cytospins) for discordant responses. In all, 6023 pathologist responses and 3825 cytotechnologist responses were reviewed. Non-ThinPrep preparations comprised 93% (n = 11 588) of the challenges, while 7% (n = 912) were TP material. A match for a "positive/suspicious" diagnosis was seen in 88.5% of NTP and 95.9% of TP preparations (P < .001). These results were statistically significant when the specific reference diagnosis was adenocarcinoma (P < .001). Overall performance of cytotechnologists was not different from that of pathologists (89.2% versus 89.0%; P = .75). Cytotechnologists had better performance for detecting squamous cell carcinoma (96.3% versus 92.6%; P < .001), while pathologists had better performance for detecting spindle cell neoplasm (79.7% versus 42.9%; P < .001). ThinPrep preparations performed significantly better than NTP preparations in gastrointestinal cytology specimens circulated in an interlaboratory comparison program. Performance varied by reference interpretation, with the best performance for the interpretation of adenocarcinoma. Cytotechnologists and pathologists performed at the same level overall, but with differences for the diagnosis of spindle cell neoplasm and squamous carcinoma.
- 1 January 2010
- Published by Wiley in Archives of Pathology & Laboratory Medicine
- Vol. 134 (1) , 19-22
Do liquid-based preparations of urinary cytology perform differently than classically prepared cases? Observations from the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology.
The cytomorphology of liquid-based preparations in urine cytology is different than classic slide preparations. To compare the performance of liquid-based preparation specimens to classically prepared urine specimens with a malignant diagnosis in the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology. Participant responses between 2000 and 2007 for urine specimens with a reference diagnosis of high-grade urothelial carcinoma/carcinoma in situ/dysplasia (HGUCA), squamous cell carcinoma, or adenocarcinoma were evaluated. ThinPrep and SurePath challenges were compared with classic preparations (smears, cytospins) for discordant responses. There were 18 288 pathologist, 11 957 cytotechnologist, and 8086 "laboratory" responses available. Classic preparations comprised 90% (n = 34 551) of urine challenges; 9% (n = 3295) were ThinPrep and 1% (n = 485) were SurePath. Concordance to the general category of "positive-malignant" was seen in 92% of classic preparations, 96.5% of ThinPrep, and 94.6% of SurePath challenges (P < .001). These results were statistically different for the exact reference interpretation of HGUCA (P < .001) but not for adenocarcinoma (P = .22). Cytotechnologists demonstrate statistically better performance for the general category of "positive-malignant" compared with pathologists for all urinary slide types and for the exact reference interpretation of HGUCA (94% versus 91.1%; P < .001) but not adenocarcinoma (96.3% versus 95.8%; P = .77) or squamous cell carcinoma (93.6% versus 87.7%; P = .07). Liquid-based preparations performed significantly better in urinary cytology challenges when evaluating malignant categories in the College of American Pathologists interlaboratory comparison program. The liquid-based preparation challenges also performed better for the exact reference interpretation of HGUCA, but no difference was observed for adenocarcinoma challenges. Cytotechnologists perform better than pathologists for all slide types, as well as those demonstrating HGUCA. These results suggest that liquid-based preparations facilitate a more accurate diagnosis than conventional preparations.
- 1 January 2010
- Published by Wiley in Archives of Pathology & Laboratory Medicine
- Vol. 134 (1) , 19-22
Do liquid-based preparations of urinary cytology perform differently than classically prepared cases? Observations from the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology.
The cytomorphology of liquid-based preparations in urine cytology is different than classic slide preparations. To compare the performance of liquid-based preparation specimens to classically prepared urine specimens with a malignant diagnosis in the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology. Participant responses between 2000 and 2007 for urine specimens with a reference diagnosis of high-grade urothelial carcinoma/carcinoma in situ/dysplasia (HGUCA), squamous cell carcinoma, or adenocarcinoma were evaluated. ThinPrep and SurePath challenges were compared with classic preparations (smears, cytospins) for discordant responses. There were 18 288 pathologist, 11 957 cytotechnologist, and 8086 "laboratory" responses available. Classic preparations comprised 90% (n = 34 551) of urine challenges; 9% (n = 3295) were ThinPrep and 1% (n = 485) were SurePath. Concordance to the general category of "positive-malignant" was seen in 92% of classic preparations, 96.5% of ThinPrep, and 94.6% of SurePath challenges (P < .001). These results were statistically different for the exact reference interpretation of HGUCA (P < .001) but not for adenocarcinoma (P = .22). Cytotechnologists demonstrate statistically better performance for the general category of "positive-malignant" compared with pathologists for all urinary slide types and for the exact reference interpretation of HGUCA (94% versus 91.1%; P < .001) but not adenocarcinoma (96.3% versus 95.8%; P = .77) or squamous cell carcinoma (93.6% versus 87.7%; P = .07). Liquid-based preparations performed significantly better in urinary cytology challenges when evaluating malignant categories in the College of American Pathologists interlaboratory comparison program. The liquid-based preparation challenges also performed better for the exact reference interpretation of HGUCA, but no difference was observed for adenocarcinoma challenges. Cytotechnologists perform better than pathologists for all slide types, as well as those demonstrating HGUCA. These results suggest that liquid-based preparations facilitate a more accurate diagnosis than conventional preparations.
- Open Access
- 1 January 2010
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 134 (1) , 19-22
Do Liquid-Based Preparations of Urinary Cytology Perform Differently Than Classically Prepared Cases? Observations From the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology
Context. —The cytomorphology of liquid-based preparations in urine cytology is different than classic slide preparations. Objectives. —To compare the performance of liquid-based preparation specimens to classically prepared urine specimens with a malignant diagnosis in the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology. Design. —Participant responses between 2000 and 2007 for urine specimens with a reference diagnosis of high-grade urothelial carcinoma/carcinoma in situ/dysplasia (HGUCA), squamous cell carcinoma, or adenocarcinoma were evaluated. ThinPrep and SurePath challenges were compared with classic preparations (smears, cytospins) for discordant responses. Results. —There were 18 288 pathologist, 11 957 cytotechnologist, and 8086 “laboratory” responses available. Classic preparations comprised 90% (n = 34 551) of urine challenges; 9% (n = 3295) were ThinPrep and 1% (n = 485) were SurePath. Concordance to the general category of “positive-malignant” was seen in 92% of classic preparations, 96.5% of ThinPrep, and 94.6% of SurePath challenges ( P < .001). These results were statistically different for the exact reference interpretation of HGUCA ( P < .001) but not for adenocarcinoma ( P = .22). Cytotechnologists demonstrate statistically better performance for the general category of “positive-malignant” compared with pathologists for all urinary slide types and for the exact reference interpretation of HGUCA (94% versus 91.1%; P < .001) but not adenocarcinoma (96.3% versus 95.8%; P = .77) or squamous cell carcinoma (93.6% versus 87.7%; P = .07). Conclusions. —Liquid-based preparations performed significantly better in urinary cytology challenges when evaluating malignant categories in the College of American Pathologists interlaboratory comparison program. The liquid-based preparation challenges also performed better for the exact reference interpretation of HGUCA, but no difference was observed for adenocarcinoma challenges. Cytotechnologists perform better than pathologists for all slide types, as well as those demonstrating HGUCA. These results suggest that liquid-based preparations facilitate a more accurate diagnosis than conventional preparations.
- 1 January 2010
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 134 (1) , 19-22
Open AccessDo Liquid-Based Preparations of Urinary Cytology Perform Differently Than Classically Prepared Cases? Observations From the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology
Context. —The cytomorphology of liquid-based preparations in urine cytology is different than classic slide preparations. Objectives. —To compare the performance of liquid-based preparation specimens to classically prepared urine specimens with a malignant diagnosis in the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytology. Design. —Participant responses between 2000 and 2007 for urine specimens with a reference diagnosis of high-grade urothelial carcinoma/carcinoma in situ/dysplasia (HGUCA), squamous cell carcinoma, or adenocarcinoma were evaluated. ThinPrep and SurePath challenges were compared with classic preparations (smears, cytospins) for discordant responses. Results. —There were 18 288 pathologist, 11 957 cytotechnologist, and 8086 “laboratory” responses available. Classic preparations comprised 90% (n = 34 551) of urine challenges; 9% (n = 3295) were ThinPrep and 1% (n = 485) were SurePath. Concordance to the general category of “positive-malignant” was seen in 92% of classic preparations, 96.5% of ThinPrep, and 94.6% of SurePath challenges ( P < .001). These results were statistically different for the exact reference interpretation of HGUCA ( P < .001) but not for adenocarcinoma ( P = .22). Cytotechnologists demonstrate statistically better performance for the general category of “positive-malignant” compared with pathologists for all urinary slide types and for the exact reference interpretation of HGUCA (94% versus 91.1%; P < .001) but not adenocarcinoma (96.3% versus 95.8%; P = .77) or squamous cell carcinoma (93.6% versus 87.7%; P = .07). Conclusions. —Liquid-based preparations performed significantly better in urinary cytology challenges when evaluating malignant categories in the College of American Pathologists interlaboratory comparison program. The liquid-based preparation challenges also performed better for the exact reference interpretation of HGUCA, but no difference was observed for adenocarcinoma challenges. Cytotechnologists perform better than pathologists for all slide types, as well as those demonstrating HGUCA. These results suggest that liquid-based preparations facilitate a more accurate diagnosis than conventional preparations.
- 26 October 2009
- Published by Wiley in Diagnostic Cytopathology
- Vol. 38 (4) , 279-282
Myoepithelial carcinoma of the parotid gland metastatic to the kidney: Case report and review of the literature
Myoepithelial carcinoma is a rare locally aggressive malignant neoplasm of the salivary glands. The tumor is composed almost exclusively of tumor cells with myoepithelial differentiation and characterized by infiltrative growth and potential for distant metastasis. Tumor cells often display morphologic heterogeneity with a wide range of cytomorphologic features, such as epithelioid, plasmacytoid, spindle, and clear cell types, making its recognition challenging. Only limited reports on its metastatic behavior are available in the literature. We describe a case of metastatic myoepithelial carcinoma of the kidney from the parotid gland diagnosed by computed tomography guided fine‐needle aspiration biopsy. Immunochemical studies are important to confirm myoepithelial differentiation of the tumor cells. Knowledge of the clinical history, radiographic characterization, andmorphological correlation with the primary tumor are emphasized. Diagn. Cytopathol. 2010.
- 26 October 2009
- Published by Wiley in Diagnostic Cytopathology
- Vol. 38 (4) , 279-282
Myoepithelial carcinoma of the parotid gland metastatic to the kidney: Case report and review of the literature
Myoepithelial carcinoma is a rare locally aggressive malignant neoplasm of the salivary glands. The tumor is composed almost exclusively of tumor cells with myoepithelial differentiation and characterized by infiltrative growth and potential for distant metastasis. Tumor cells often display morphologic heterogeneity with a wide range of cytomorphologic features, such as epithelioid, plasmacytoid, spindle, and clear cell types, making its recognition challenging. Only limited reports on its metastatic behavior are available in the literature. We describe a case of metastatic myoepithelial carcinoma of the kidney from the parotid gland diagnosed by computed tomography guided fine‐needle aspiration biopsy. Immunochemical studies are important to confirm myoepithelial differentiation of the tumor cells. Knowledge of the clinical history, radiographic characterization, andmorphological correlation with the primary tumor are emphasized. Diagn. Cytopathol. 2010.