Kentaro Kajiwara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kentaro Kajiwara has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Masugu Sato
Japan Synchrotron Radiation Research Institute (JARSI), Sayo-gun, Hyogo 679-5198, Japan
4 shared publications - Shigeru Suzuki
Institute of Multidisciplinary Research for Advanced Materials, Tohoku University
3 shared publications - Shun Fujieda
Tohoku Univ, Inst Multidisciplinary Res Adv Mat, Sendai, Miyagi 9808577, Japan
3 shared publications - Kozo Shinoda
Tohoku Uninversity
2 shared publications Satoshi Iida
Department of Physics, University of Toyama, Toyama 930-8555, Japan
2 shared publicationsYoshinori Chikaura
Graduate School of Engineering, Kyushu Institute of Technology, Kitakyushu-shi, Fukuoka 804-8550, Japan
2 shared publications
Latest Publications
- 27 November 2025
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1169, 3-8
White-Beam X-Ray Sectional Topography of Anthracene Single Crystals Grown by Physical Vapor Transport Technique
White-beam X-ray sectional topography enabled the successful evaluation of the quality of anthracene single crystals grown by the physical vapor transport technique; however, such single crystals exhibited a thin plateletlike configuration and their quality is difficult to evaluate in the cross-sectional direction. The experimental results showed that the anthracene single crystals grown by the physical vapor transport technique maintained their high quality; however, they tended to have widespread hollows inside owing to their specific configuration.
- 27 November 2025
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1169, 3-8
White-Beam X-Ray Sectional Topography of Anthracene Single Crystals Grown by Physical Vapor Transport Technique
White-beam X-ray sectional topography enabled the successful evaluation of the quality of anthracene single crystals grown by the physical vapor transport technique; however, such single crystals exhibited a thin plateletlike configuration and their quality is difficult to evaluate in the cross-sectional direction. The experimental results showed that the anthracene single crystals grown by the physical vapor transport technique maintained their high quality; however, they tended to have widespread hollows inside owing to their specific configuration.
- 25 June 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (4) , 1174-1177
Direct cross-sectional imaging using X-ray Compton scattering: application to commercial batteries
A synchrotron-based technique using Compton scattering imaging is presented. This technique has been applied to a coin battery (CR2023), and the cross-sectional image has been obtained in 34 ms without sample rotation. A three-dimensional image of the whole structure has been reconstructed from 74 cross-sectional images taken consecutively by scanning the incident, wide X-ray beam along one direction. This work demonstrates that quick cross-sectional imaging of regions of interest and three-dimensional image reconstruction without sample rotation are feasible using Compton scattering imaging.
- 25 June 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (4) , 1174-1177
Direct cross-sectional imaging using X-ray Compton scattering: application to commercial batteries
A synchrotron-based technique using Compton scattering imaging is presented. This technique has been applied to a coin battery (CR2023), and the cross-sectional image has been obtained in 34 ms without sample rotation. A three-dimensional image of the whole structure has been reconstructed from 74 cross-sectional images taken consecutively by scanning the incident, wide X-ray beam along one direction. This work demonstrates that quick cross-sectional imaging of regions of interest and three-dimensional image reconstruction without sample rotation are feasible using Compton scattering imaging.
- Open Access
Effect of Laser Peening on the Mechanical Properties of Aluminum Alloys Probed by Synchrotron Radiation and X-Ray Free Electron Laser
Synchrotron radiation (SR) and X-ray free electron laser (XFEL) are indispensable tools not only for the exploration of science but also for the evolution of industry. We used SR and XFEL to elucidate the mechanism and the effects of laser peening without coating (LPwC) which enhances the durability of metallic materials. X-ray diffraction (XRD) employing SR revealed that the residual stress (RS) in the top surface became compressive as the laser pulse irradiation density increased with appropriate overlapping of adjacent laser pulses. SR-based computed tomography (CT) was used to nondestructively reconstruct three-dimensional (3D) images of fatigue cracks in aluminum alloy, revealing that LPwC retarded crack propagation on the surface and inside of the sample. SR-based computed laminography (CL) was applied to friction stir welded (FSWed) aluminum alloy plates to visualize fatigue cracks propagating along the welds. The fatigue crack had complicated shape; however, it became a semi-ellipsoid once projected onto a plane perpendicular to the fatigue loading direction. Ultra-fast XRD using an XFEL was conducted to investigate the dynamic response of aluminum alloy to an impulsive pressure wave simulating the LPwC condition. The diffraction pattern changed from spotty to smooth, implying grain refinement or subgrain formation. Shifts in diffraction angles were also observed, coinciding with the pressure history of laser irradiation. The durations of the dynamic phenomena were less than 1 µs; it may be possible to use high-repetition lasers at frequencies greater than kHz to reduce LPwC processing times.
Open AccessEffect of Laser Peening on the Mechanical Properties of Aluminum Alloys Probed by Synchrotron Radiation and X-Ray Free Electron Laser
Synchrotron radiation (SR) and X-ray free electron laser (XFEL) are indispensable tools not only for the exploration of science but also for the evolution of industry. We used SR and XFEL to elucidate the mechanism and the effects of laser peening without coating (LPwC) which enhances the durability of metallic materials. X-ray diffraction (XRD) employing SR revealed that the residual stress (RS) in the top surface became compressive as the laser pulse irradiation density increased with appropriate overlapping of adjacent laser pulses. SR-based computed tomography (CT) was used to nondestructively reconstruct three-dimensional (3D) images of fatigue cracks in aluminum alloy, revealing that LPwC retarded crack propagation on the surface and inside of the sample. SR-based computed laminography (CL) was applied to friction stir welded (FSWed) aluminum alloy plates to visualize fatigue cracks propagating along the welds. The fatigue crack had complicated shape; however, it became a semi-ellipsoid once projected onto a plane perpendicular to the fatigue loading direction. Ultra-fast XRD using an XFEL was conducted to investigate the dynamic response of aluminum alloy to an impulsive pressure wave simulating the LPwC condition. The diffraction pattern changed from spotty to smooth, implying grain refinement or subgrain formation. Shifts in diffraction angles were also observed, coinciding with the pressure history of laser irradiation. The durations of the dynamic phenomena were less than 1 µs; it may be possible to use high-repetition lasers at frequencies greater than kHz to reduce LPwC processing times.
- 1 December 2015
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 653, 195-201
Local stress development in polycrystalline Fe-17mol%Ga alloy under tensile loading – In situ measurement using synchrotron X-ray micro-beam
- 1 December 2015
- Published by Elsevier in Journal of Alloys and Compounds
- Vol. 653, 195-201
Local stress development in polycrystalline Fe-17mol%Ga alloy under tensile loading – In situ measurement using synchrotron X-ray micro-beam
- Open Access
Characterization of Deformation Behavior of Individual Grains in Polycrystalline Cu-Al-Mn Superelastic Alloy Using White X-ray Microbeam Diffraction
White X-ray microbeam diffraction was applied to investigate the microscopic deformation behavior of individual grains in a Cu-Al-Mn superelastic alloy. Strain/stresses were measured in situ at different positions in several grains having different orientations during a tensile test. The results indicated inhomogeneous stress distribution, both at the granular and intragranular scale. Strain/stress evolution showed reversible phenomena during the superelastic behavior of the tensile sample, probably because of the reversible martensitic transformation. However, strain recovery of the sample was incomplete due to the residual martensite, which results in the formation of local compressive residual stresses at grain boundary regions.
Open AccessCharacterization of Deformation Behavior of Individual Grains in Polycrystalline Cu-Al-Mn Superelastic Alloy Using White X-ray Microbeam Diffraction
White X-ray microbeam diffraction was applied to investigate the microscopic deformation behavior of individual grains in a Cu-Al-Mn superelastic alloy. Strain/stresses were measured in situ at different positions in several grains having different orientations during a tensile test. The results indicated inhomogeneous stress distribution, both at the granular and intragranular scale. Strain/stress evolution showed reversible phenomena during the superelastic behavior of the tensile sample, probably because of the reversible martensitic transformation. However, strain recovery of the sample was incomplete due to the residual martensite, which results in the formation of local compressive residual stresses at grain boundary regions.
- Open Access
- 1 August 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 996, 135-140
Microscopic Stress and Strain Evolved in a Twinning-Induced Plasticity Fe-Mn-C Steel
White X-ray diffraction with micro-beam synchrotron radiation was used to analyze microscopic stress evolved in coarse grains of a twinning-induced plasticity Fe-Mn-C steel under tensile loading. In addition, electron backscatter diffraction (EBSD) was used to determine the crystal orientation of grains in the polycrystalline Fe-Mn-C steel. Based on these orientation data, the stress and strain distribution in the microstructure of the steel under tensile loading was estimated using FEM simulation where the elastic anisotropy or the crystal orientation dependence of the elasticity was taken into account. The FEM simulation showed that the strain distribution in the microstructure depends on the crystal orientation of each grain. The stress analysis by the white X-ray diffraction indicated that the direction of the maximum principal stresses at measured points in the steel under tensile loading are mostly oriented toward the tensile direction. This is qualitatively consistent with the results of by the FEM simulation, although absolute values of the principal stresses may contain the effect of heterogeneous plastic deformation on the stress distribution.
- 1 August 2014
- Published by Trans Tech Publications, Ltd. in Advanced Materials Research
- Vol. 996, 135-140
Open AccessMicroscopic Stress and Strain Evolved in a Twinning-Induced Plasticity Fe-Mn-C Steel
White X-ray diffraction with micro-beam synchrotron radiation was used to analyze microscopic stress evolved in coarse grains of a twinning-induced plasticity Fe-Mn-C steel under tensile loading. In addition, electron backscatter diffraction (EBSD) was used to determine the crystal orientation of grains in the polycrystalline Fe-Mn-C steel. Based on these orientation data, the stress and strain distribution in the microstructure of the steel under tensile loading was estimated using FEM simulation where the elastic anisotropy or the crystal orientation dependence of the elasticity was taken into account. The FEM simulation showed that the strain distribution in the microstructure depends on the crystal orientation of each grain. The stress analysis by the white X-ray diffraction indicated that the direction of the maximum principal stresses at measured points in the steel under tensile loading are mostly oriented toward the tensile direction. This is qualitatively consistent with the results of by the FEM simulation, although absolute values of the principal stresses may contain the effect of heterogeneous plastic deformation on the stress distribution.
- Open Access
- 10 April 2014
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 502 (1) , 012020
Development of technique for three-dimensional visualization of grain boundaries by white X-ray microbeam
A technique for three-dimensional visualization of grain boundaries was developed at BL28B2 at SPring-8. The technique uses white X-ray microbeam diffraction and a rotating slit. Three-dimensional images of small silicon single crystals filled in a plastic tube were successfully obtained using this technique for demonstration purposes. The images were consistent with those obtained by X-ray computed tomography.
- 10 April 2014
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 502 (1) , 012020
Open AccessDevelopment of technique for three-dimensional visualization of grain boundaries by white X-ray microbeam
A technique for three-dimensional visualization of grain boundaries was developed at BL28B2 at SPring-8. The technique uses white X-ray microbeam diffraction and a rotating slit. Three-dimensional images of small silicon single crystals filled in a plastic tube were successfully obtained using this technique for demonstration purposes. The images were consistent with those obtained by X-ray computed tomography.
- 22 June 2009
- Published by Wiley in Physica Status Solidi (a)
- Vol. 206 (8) , 1838-1841
Development of visualization method of grain boundaries in stainless steel by using white X-ray micro-beam and image detector
- 22 June 2009
- Published by Wiley in Physica Status Solidi (a)
- Vol. 206 (8) , 1838-1841
Development of visualization method of grain boundaries in stainless steel by using white X-ray micro-beam and image detector
- 31 July 2007
- Published by Wiley in Physica Status Solidi (a)
- Vol. 204 (8) , 2682-2687
Features of dislocation images reconstructed from step‐scanned white X‐ray section topographs
- 31 July 2007
- Published by Wiley in Physica Status Solidi (a)
- Vol. 204 (8) , 2682-2687
Features of dislocation images reconstructed from step‐scanned white X‐ray section topographs
- 1 December 2004
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 96 (11) , 6259-6261
Observation of silicon front surface topographs of an ultralarge-scale-integrated wafer by synchrotron x-ray plane wave
Surface roughness and undulation of unpatterned silicon wafers are serious issues for ultralarge-scale-integrated circuit devices, even after fine mechanochemical polishing. It has never been clarified whether the undulations exist only on the surface or also exist inside the bulk crystal. We produced grazing incident diffraction topographs at three x-ray photon energies, with penetration depths estimated to be 3.85 nm, 4.78 nm, and 1.28 µm. All the topographs contained striation. We also obtained clear total reflection images using synchrotron x-ray plane waves, which also showed striation patterns at penetration depths from 3.85 nm to 1.28 µm. These results indicate that the origin of the patterns is not at the surface but is inside the Si wafer. The origin of striation patterns, observed in the topographs, was found not to be due to mechanochemical polishing processes but to crystal growth
- 1 December 2004
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 96 (11) , 6259-6261
Observation of silicon front surface topographs of an ultralarge-scale-integrated wafer by synchrotron x-ray plane wave
Surface roughness and undulation of unpatterned silicon wafers are serious issues for ultralarge-scale-integrated circuit devices, even after fine mechanochemical polishing. It has never been clarified whether the undulations exist only on the surface or also exist inside the bulk crystal. We produced grazing incident diffraction topographs at three x-ray photon energies, with penetration depths estimated to be 3.85 nm, 4.78 nm, and 1.28 µm. All the topographs contained striation. We also obtained clear total reflection images using synchrotron x-ray plane waves, which also showed striation patterns at penetration depths from 3.85 nm to 1.28 µm. These results indicate that the origin of the patterns is not at the surface but is inside the Si wafer. The origin of striation patterns, observed in the topographs, was found not to be due to mechanochemical polishing processes but to crystal growth