MTMariko Takenokuchi

Mariko Takenokuchi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mariko Takenokuchi has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantitative analysis of hemin-induced neutrophil extracellular trap formation and effects of hydrogen peroxide on this phenomenon

    by Ayako Ohbuchi, Mari Kono, Kaihei Kitagawa, Mariko Takenokuchi, Shion Imoto, Katsuyasu Saigo


    • 1 June 2015
      • Vol. 35  (6) , 3307-16

    Bortezomib Causes ER Stress-related Death of Acute Promyelocytic Leukemia Cells Through Excessive Accumulation of PML-RARA.

    by Mariko Takenokuchi, Kazuhide Miyamoto, Katsuyasu Saigo, Taizo Taniguchi

    The success of proteasome inhibitors in therapy of multiple myeloma has led to their use for other malignancies. For the proteasome inhibitor bortezomib, combination therapies with histone deacetylase inhibitors, which up-regulate ubiquitin-proteasome system (UPS)-related enzymes, produce a beneficial effect. However, the mechanisms underlying the effect of bortezomib are not completely understood. We hypothesized that bortezomib causes excessive accumulation of aberrant proteins, which augments endoplasmic reticulum (ER) stress, leading to death of malignant cells. The NB4 cell line established from a patient with acute promyelocytic leukemia (APL) expressing the promyelocytic leukemia/retinoic acid receptor alpha (PML-RARA) fusion protein was used to assess changes in cell viability and apoptosis caused by bortezomib, as well as alterations in PML-RARA and UPS-related enzymes via western blotting and immunoprecipitation assays. Bortezomib time- and dose-dependently reduced cell viability and induced apoptosis. Bortezomib significantly increased the abundance of ubiquitinated-PML-RARA (Ub-PML-RARA), ubiquitin-conjugating human enzyme 8 (UbcH8), and Ub-UbcH8, indicating that UbcH8 is the E2 ubiquitin-conjugating enzyme for PML-RARA. Moreover, UbcH8 abundance was dose-dependently increased in the culture supernatant of bortezomib-treated cells. UbcH8 may have a utility as a biomarker of treatment response to bortezomib in patients with APL. Furthermore, bortezomib impairs the UPS that controls normal protein homeostasis by causing excessive accumulation of PML-RARA augmenting ER stress and leading to APL cell death. The study provides a rationale for incorporating proteasome inhibitors in the treatment of diseases expressing aberrant proteins. Furthermore, monitoring of UPS-related enzymes might have use in predicting the treatment response to proteasome inhibitors and in assessing their therapeutic effects.


  • LETTER TO THE EDITOR: Significance of Platelet Most Frequent Volume for Platelet Size Evaluation

    by Setsuki Isono, Megumi Tatsuta, Keiko Nagata, Keiko Numata, Masumi Nishigaki, Akiharu Okamura, Masahumi Takata, Mariko Okano, Humiko Hatano, Hiroyasu Uemura, et al.

    • 1 January 2012
      • Vol. 58, 857-60

    Significance of platelet most frequent volume for platelet size evaluation.

    by Setsuki Isono, Megumi Tatsuta, Keiko Nagata, Keiko Numata, Masumi Nishigaki, Akiharu Okamura, Masahumi Takata, Mariko Okano, Humiko Hatano, Hiroyasu Uemura, et al.


  • Quantitative detection of PML‐RARα fusion transcript by real‐time PCR with a single primer pair

    by Mariko Takenokuchi, Yuji Nakamachi, Keiko Yoneda, Kana Joo, Seiji Kawano, Eiji Tatsumi, Katsuyasu Saigo, Shunichi Kumagai

    Quantitative detection of minimal residual disease has prognostic value for some leukemias. Acute promyelocytic leukemia (APL) is characterized by the specific PML‐RARα fusion gene from t(15;17). Added to three PML‐RARα isoforms, alternative spliced forms of PML exons give rise to multiple isoforms even within a single patient. To date, multiple primer pairs for the detection of the various PML‐RARα transcripts have been designed, potentially generating some nonspecific amplification products. Here, we established a real‐time quantitative PCR (RQ‐PCR) strategy with a single primer pair using LightCycler (sp‐RQ‐PCR), which could simultaneously detect three isoforms with equal specificity and sensitivity as well as alternative spliced forms. Results obtained with sp‐RQ‐PCR for 39 samples from 15 APL patients and 31 non‐APL samples were compared with those with TaqMan™ assay with three primer pairs. In two of the APL samples, PML‐RARα was detected in the TM, but not in the sp‐RQ‐PCR or nested PCR. Furthermore, the sp‐RQ‐PCR showed no positive results for the 31 non‐APL samples, whereas the TM identified 13% (4/31) as positive. Electrophoresis detected some artifacts in the TM, which do not correspond to PML‐RARα. We conclude that our sp‐RQ‐PCR is specific enough to identify various forms of PML‐RARα and yields no false‐positive results. J. Clin. Lab. Anal. 23:223–230, 2009.


    • 1 November 2008
      • Vol. 56  (11) , 967-72

    [Activation of human neutrophils by hemin].

    by Katsuyasu Saigo, Makoto Hashimoto, Yukie Jyokei, Mariko Takenokuchi, Takeshi Sugimoto, Kimiko Kazumura, Hiroshi Tsuchiya, Shion Imoto, Shunichi Kumagai

    Activation of neutrophils by free heme is considered as one of the mechanisms for cellular dysfunction under the conditions of hemorrhage or tissue damage. We studied about the effects of hemin, ferriprotoporphyrin IX, on human neutrophil activation by measurements of adhesion molecule expression and reactive oxygen species (ROS) production. Human neutrophils purified from heparinized blood of healthy volunteers were stimulated with hemin. Surface expression of CD11b and L-selectin were evaluated by flow cytometry, and superoxide production was detected by chemiluminescence. Hemin increased the expression of CD11b and produced superoxide accompanying by increase in intracellular free calcium concentration. Thus, free heme-molecule is suggested to possess the activity to initiate or aggravate tissue injuries. Since neutrophils do not express CD163, scavenger receptor for hemoglobin-haptoglobin complex, the mechanisms by which hemin exerts these effects are still to be studied.


    • 1 September 2008
      • Vol. 56  (9) , 791-801

    [Neutrophil function tests and oxidative stress detection as clinical examinations].

    by Katsuyasu Saigo, Mariko Takenokuchi, Shion Imoto

    We herein introduce several clinically available methods to detect neutrophil function and oxidative stress. The flowcytometric detection of adhesive protein expression, such as CD11b(Mac-1), assessment of phagocytosis activity, and measurement of reactive oxygen species (ROS) production are relatively easy to apply as tools for laboratory medicine. A new device to simultaneously detect superoxide and calcium ion influx is also introduced. Oxidative stress induced by ROS produced not only from phagocytic cells but also from the mitochondria or endoplamic reticulum of all kinds of living cells is etiologically related to many disorders and also aging. A simple method using the FRAS4 instrument is demonstrated. These methods are expected to be clinically beneficial, especially in hematology, transfusion medicine, and the public health field.

    • 1 March 2008
      • Vol. 56  (3) , 203-10

    [Laboratory medicine for blood transfusion and transplantation medicine].

    by Katsuyasu Saigo, Makoto Hashimoto, Takeshi Sugimoto, Mariko Takenokuchi, Shion Imoto, Shunichi Kumagai

    We discussed the usefulness of routine technologies of laboratory medicine in blood transfusion and transplantation medicine. New parameters that can be measured by automated hematology analyzers have been clinically evaluated and proven to be useful so far. Based on our experience, detection systems for fragmented red cells (FRC), immature platelets (immature platelet function, IPF), and hematopoietic progenitor cells (HPC) are useful for the diagnosis of thrombotic microangiopathy, differential diagnosis of thrombocytopenia, and decision regarding the optimal timing to collect peripheral stem cells, respectively. Moreover, IPF were suggested to be an indicator of the platelet transfusion requirement. The establishment of non invasive assaying technology has been eagerly anticipated. We evaluated a hemoglobin measurement tool, and revealed that it might be applicable in predeposited, autologous blood donation. Some adverse transfusion reactions are related to neutrophil activation. Thus, we investigated the effects of serum from patients and blood donors, in the context of adverse reactions, on adhesion molecule expressions of neutrophils from volunteers using flow-cytometry. This kind of simple technology is expected to be useful in future studies to clarify the mechanisms and prevent adverse reactions.

    • 1 November 2006
      • Vol. 54  (11) , 1106-9

    [Evaluation of a non-invasive hemoglobin measurement device for pre-deposited autologous blood donation].

    by Kyoko Matsunagai, Katsuyasu Saigo, Makoto Hashimoto, Manami Kishimoto, Mariko Takenokuchi, Hiroko Narita, Toshiyuki Ozawa, Shunichi Kumagai

    A non-invasive hemoglobin measurement instrument (Sysmex Co.Ltd., Kobe, Japan) was used for the evaluation of hemoglobin levels just before blood drawing for repeat autologous blood donation. There was a statistically significant correlation (r = 0.598) between the hemoglobin levels determined with the non-invasive instrument (NINV-Hb) and true Hb levels (T-Hb) evaluated by direct analysis with automatic hematology analyzer, KX-21 (Sysmex). The analysis used 156 data obtained from 66 patients. Ten patients whose differences between NINV-Hb and T-Hb of the first blood donation were more than 2.1 g/dl were excluded from further analysis. Imaging analysis indicated difficulties with the detection of appropriate blood vessel images in one of these patients, but the reasons for other patients were not apparent. There was a closer relationship between NINV-Hb and T-Hb for the 76 measurements for the second or third blood donation obtained from 56 patients (r = 0.704) than for the entire data (r = 0.598). When 12 g/dl was used as the cut off value for NINV-Hb, sensitivity and specificity for the detection of 1l g/dl of T-Hb, which is considered the critical level for drawing autologous blood for donation, were 83.6% and 77.8%, respectively. We conclude, therefore, that NINV-Hb evaluation can be expected to be useful for repeated autologous blood donation of limited patients, however, it is strongly expected to develop a new system having more sensitive and accurately detectable ability.


    • 1 April 2002
      • Vol. 50  (4) , 392-7

    [Comparative evaluation of serum HCV RNA by Roche Monitor Assay. Versions 1.0 and 2.0; as a predictive marker of subsequent response to IFN therapy].

    by Mariko Takenokuchi, Chie Yasuda, Yuji Nakamachi, Masahiko Mukai, Seitetsu Yoon, Shinichi Kondoh, Shunichi Kumagai

    Quantitative measurement of serum hepatitis C virus(HCV) RNA is important in predicting and monitoring interferon(IFN) therapy. We compared the sensitivity of HCV RNA measurement of different HCV genotypes between two available assays, Roche Monitor 1.0(v1.0) and Roche Monitor 2.0(v2.0). We also evaluated serum level of HCV RNA as the predictors of a long-term response to IFN therapy by distinguishing the complete responders(CR), partial responders(PR) and non-responders(NR) for IFN therapy. We quantified the serum HCV RNA levels in 151 patients and determined the genotypes; 96(64%) with genotype 1b(1b), 42(28%) with genotype 2a(2a), and 6(4%) was not identified. The relationship between the genotype and effects of IFN treatment was as follows: 23CR(1b:11, 2a:9), 15PR(1b:8, 2a:7), 20NR(1b:14, 2a:6). The RNA levels of 2a measured by v2.0 were significantly higher than those by v1.0(p < 0.05), although no significant difference was found in 1b between two assays. By using v2.0, when the cut-off level was set at 200 x 10(3) IU/ml before IFN therapy, CR was discriminated from PR, NR with a predicting efficiency of 88%. HCV RNA levels before IFN therapy were significantly lower in patients who became HCV RNA negative within 2 weeks than in patients who did at 4 weeks or longer. These results suggest that v2.0 is more sensitive and accurate than v1.0 for the quantification of 2a. Using v2.0 assay, it was shown that low viral titre at pretreatment and loss of viraemia within 2 weeks after treatment might be important markers for a long-term response to IFN therapy, irrespective of viral genotype. The v2.0 assay was found to be more useful in predicting effectiveness of IFN therapy.