Douwe de Boer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Douwe de Boer has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Otto Bekers
Maastricht University Medical Center
4 shared publicationsAlexander S. Streng
Maastricht University Medical Center
3 shared publicationsNoreen van der Linden
Department of Clinical Chemistry, Central Diagnostic Laboratory, Maastricht University Medical Center, Maastricht, the Netherlands
2 shared publicationsWill K. W. H. Wodzig
Maastricht University Medical Center
2 shared publicationsWill K.W.H. Wodzig
Department of Clinical Chemistry, Central Diagnostic Laboratory, Maastricht University Medical Center, Maastricht, the Netherlands
2 shared publicationsAlma M. A. Mingels
Maastricht University Medical Center
1 shared publication
Latest Publications
- Open Access
- 8 July 2026
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
Mass Spectrometric Characterization of Flucloxacillin Binding to Serum Albumin in Hospitalized Patients With Hypoalbuminemia: An Observational Pilot Study
Purpose: To facilitate antibiotic dose optimization, novel insights into flucloxacillin pharmacokinetics and serum protein binding in critically ill patients are needed. Therefore, this study assessed the number of flucloxacillin molecules bound to a serum albumin molecule (stoichiometry) in hospitalized patients with hypoalbuminemia. Methods: Adult hospitalized patients with serum hypoalbuminemia administered intravenous flucloxacillin were enrolled in this prospective, observational, single-center pilot study. Patients treated with piperacillin/tazobactam or amoxicillin/clavulanic acid served as controls. Matrix-assisted laser desorption–ionization time-of-flight mass spectrometry measurements were performed to calculate the stoichiometry of the antibiotic/albumin complexes. In addition, the associations between the stoichiometry and antibiotic treatment duration, serum albumin concentration, or time since flucloxacillin treatment cessation were assessed using association plots. Results: Eleven patients treated with flucloxacillin and 4 control patients were enrolled. A total of 251 stoichiometric measurements were considered. Large intra- and interindividual differences were observed in the stoichiometry. These values ranged from 0 to 6 flucloxacillin molecules bound to albumin. In 8 patients (72%), an increase in the stoichiometry as the number of flucloxacillin treatment days increased was confirmed. In addition, the stoichiometry increased at low albumin concentrations, and a stoichiometry of ≥3 was observed for 2–8 days after flucloxacillin treatment cessation. Conclusions: Prolonged flucloxacillin treatment and low serum albumin concentrations were associated with a high stoichiometry of flucloxacillin/albumin complexes in hospitalized patients with serum hypoalbuminemia. This study illustrates that protein binding is not a constant, thereby contributing to current understanding of the pharmacokinetics, effectiveness, and toxicity of flucloxacillin.
- 8 July 2026
- Published by Wolters Kluwer Health in Therapeutic Drug Monitoring
Open AccessMass Spectrometric Characterization of Flucloxacillin Binding to Serum Albumin in Hospitalized Patients With Hypoalbuminemia: An Observational Pilot Study
Purpose: To facilitate antibiotic dose optimization, novel insights into flucloxacillin pharmacokinetics and serum protein binding in critically ill patients are needed. Therefore, this study assessed the number of flucloxacillin molecules bound to a serum albumin molecule (stoichiometry) in hospitalized patients with hypoalbuminemia. Methods: Adult hospitalized patients with serum hypoalbuminemia administered intravenous flucloxacillin were enrolled in this prospective, observational, single-center pilot study. Patients treated with piperacillin/tazobactam or amoxicillin/clavulanic acid served as controls. Matrix-assisted laser desorption–ionization time-of-flight mass spectrometry measurements were performed to calculate the stoichiometry of the antibiotic/albumin complexes. In addition, the associations between the stoichiometry and antibiotic treatment duration, serum albumin concentration, or time since flucloxacillin treatment cessation were assessed using association plots. Results: Eleven patients treated with flucloxacillin and 4 control patients were enrolled. A total of 251 stoichiometric measurements were considered. Large intra- and interindividual differences were observed in the stoichiometry. These values ranged from 0 to 6 flucloxacillin molecules bound to albumin. In 8 patients (72%), an increase in the stoichiometry as the number of flucloxacillin treatment days increased was confirmed. In addition, the stoichiometry increased at low albumin concentrations, and a stoichiometry of ≥3 was observed for 2–8 days after flucloxacillin treatment cessation. Conclusions: Prolonged flucloxacillin treatment and low serum albumin concentrations were associated with a high stoichiometry of flucloxacillin/albumin complexes in hospitalized patients with serum hypoalbuminemia. This study illustrates that protein binding is not a constant, thereby contributing to current understanding of the pharmacokinetics, effectiveness, and toxicity of flucloxacillin.
- Open Access
- 24 July 2025
- Published by European Medical Group in EMJ Allergy & Immunology
- Vol. 10 (1) , 69-70
Reference Values of Eosinophil-derived Neurotoxin in Blood: Reasons to Use Ethylenediaminetetraacetic Acid Plasma
Eosinophil-derived neurotoxin (EDN), as a biomarker of eosinophilic activity, can be measured in blood matrices such...
- 24 July 2025
- Published by European Medical Group in EMJ Allergy & Immunology
- Vol. 10 (1) , 69-70
Open AccessReference Values of Eosinophil-derived Neurotoxin in Blood: Reasons to Use Ethylenediaminetetraacetic Acid Plasma
Eosinophil-derived neurotoxin (EDN), as a biomarker of eosinophilic activity, can be measured in blood matrices such...
- Open Access
- 2 June 2025
- Published by Frontiers Media SA in Frontiers in Allergy
- Vol. 6, 1515294
Multiplex IgE peanut panels: a critical appraisal of assay designs and the good, the bad, and the ugly features of the applied allergen components
Background: Multiplex allergy assays are currently well-established in allergy diagnostics. However, the different assays in terms of designs and performance are also claimed to be heterogeneous as no agreed standards and requirements are available.Objective: We aimed to compare the analytical assay designs of the ISAC, ALEX, and EUROLINE peanut (Ara h) panels and the features of the applied isoallergens and variants to create more awareness of the heterogeneity of multiplex allergy assays.Methods: We conducted a multi-source survey in publicly available data sources and among manufacturers and performed correlation studies using patients’ serum samples.Results: The survey proved that the panels are indeed very heterogeneous in many ways, especially regarding the allergen component origin and isoallergen composition. Despite that, we found adequate correlations between IgE against the clinically relevant Ara h storage proteins measured by the panels. However, for the clinically relevant lipid transfer protein Ara h 9, the correlations were less adequate, which could be caused by the different Ara h 9 isoallergens used in the studied panels. For cross-reactive carbohydrate determinants (CCDs), the results were complicated, which also corresponds to the complex nature of CCDs and the different inhibition procedures. The detection of subpopulations of patients for all panallergens illustrated the heterogeneous nature of peanut IgE in general and of the peanut panels studied. Regarding the overall features provided for the three panels, we classified the peanut allergen components and CCDs by their good, bad, and even ugly features when used within these panels.Conclusions: Knowledge of the origin and respective isoallergen specifications of the peanut allergen components including the exact CCD composition is essential. Together with that of the variants, this should be documented more adequately in scientific studies and in the respective instructions for the use of multiplex allergy assays.
- 2 June 2025
- Published by Frontiers Media SA in Frontiers in Allergy
- Vol. 6, 1515294
Open AccessMultiplex IgE peanut panels: a critical appraisal of assay designs and the good, the bad, and the ugly features of the applied allergen components
Background: Multiplex allergy assays are currently well-established in allergy diagnostics. However, the different assays in terms of designs and performance are also claimed to be heterogeneous as no agreed standards and requirements are available.Objective: We aimed to compare the analytical assay designs of the ISAC, ALEX, and EUROLINE peanut (Ara h) panels and the features of the applied isoallergens and variants to create more awareness of the heterogeneity of multiplex allergy assays.Methods: We conducted a multi-source survey in publicly available data sources and among manufacturers and performed correlation studies using patients’ serum samples.Results: The survey proved that the panels are indeed very heterogeneous in many ways, especially regarding the allergen component origin and isoallergen composition. Despite that, we found adequate correlations between IgE against the clinically relevant Ara h storage proteins measured by the panels. However, for the clinically relevant lipid transfer protein Ara h 9, the correlations were less adequate, which could be caused by the different Ara h 9 isoallergens used in the studied panels. For cross-reactive carbohydrate determinants (CCDs), the results were complicated, which also corresponds to the complex nature of CCDs and the different inhibition procedures. The detection of subpopulations of patients for all panallergens illustrated the heterogeneous nature of peanut IgE in general and of the peanut panels studied. Regarding the overall features provided for the three panels, we classified the peanut allergen components and CCDs by their good, bad, and even ugly features when used within these panels.Conclusions: Knowledge of the origin and respective isoallergen specifications of the peanut allergen components including the exact CCD composition is essential. Together with that of the variants, this should be documented more adequately in scientific studies and in the respective instructions for the use of multiplex allergy assays.
- Open Access
- 29 August 2023
- Published by Elsevier in Journal of Immunological Methods
- Vol. 522, 113552
Identifying therapeutic monoclonal antibodies using target protein collision electrophoresis reflex assay to separate the wheat from the chaff
- 29 August 2023
- Published by Elsevier in Journal of Immunological Methods
- Vol. 522, 113552
Open AccessIdentifying therapeutic monoclonal antibodies using target protein collision electrophoresis reflex assay to separate the wheat from the chaff
- 7 May 2021
- Published by Springer Nature
- Vol. 1306, 41-59
Cardiac Troponin T: The Impact of Posttranslational Modifications on Analytical Immunoreactivity in Blood up to the Excretion in Urine
Cardiac troponin T (cTnT) is a sensitive and specific biomarker for detecting cardiac muscle injury. Its concentration in blood can be significantly elevated outside the normal reference range under several pathophysiological conditions. The classical analytical method in routine clinical analysis to detect cTnT in serum or plasma is a single commercial immunoassay, which is designed to quantify the intact cTnT molecule. The targeted epitopes are located in the central region of the cTnT molecule. However, in blood cTnT exists in different biomolecular complexes and proteoforms: bound (to cardiac troponin subunits or to immunoglobulins) or unbound (as intact protein or as proteolytic proteoforms). While proteolysis is a principal posttranslational modification (PTM), other confirmed PTMs of the proteoforms include N-terminal initiator methionine removal, N-acetylation, O-phosphorylation, O-(N-acetyl)-glucosaminylation, N(ɛ)-(carboxymethyl)lysine modification and citrullination. The immunoassay probably detects several of those cTnT biomolecular complexes and proteoforms, as long as they have the centrally targeted epitopes in common. While analytical cTnT immunoreactivity has been studied predominantly in blood, it can also be detected in urine, although it is unclear in which proteoform cTnT immunoreactivity is present in urine. This review presents an overview of the current knowledge on the pathophysiological lifecycle of cTnT. It provides insight into the impact of PTMs, not only on the analytical immunoreactivity, but also on the excretion of cTnT in urine as one of the waste routes in that lifecycle. Accordingly, and after isolating the proteoforms from urine of patients suffering from proteinuria and acute myocardial infarction, the structures of some possible cTnT proteoforms are reconstructed using mass spectrometry and presented.
- 7 May 2021
- Published by Springer Nature
- Vol. 1306, 41-59
Cardiac Troponin T: The Impact of Posttranslational Modifications on Analytical Immunoreactivity in Blood up to the Excretion in Urine
Cardiac troponin T (cTnT) is a sensitive and specific biomarker for detecting cardiac muscle injury. Its concentration in blood can be significantly elevated outside the normal reference range under several pathophysiological conditions. The classical analytical method in routine clinical analysis to detect cTnT in serum or plasma is a single commercial immunoassay, which is designed to quantify the intact cTnT molecule. The targeted epitopes are located in the central region of the cTnT molecule. However, in blood cTnT exists in different biomolecular complexes and proteoforms: bound (to cardiac troponin subunits or to immunoglobulins) or unbound (as intact protein or as proteolytic proteoforms). While proteolysis is a principal posttranslational modification (PTM), other confirmed PTMs of the proteoforms include N-terminal initiator methionine removal, N-acetylation, O-phosphorylation, O-(N-acetyl)-glucosaminylation, N(ɛ)-(carboxymethyl)lysine modification and citrullination. The immunoassay probably detects several of those cTnT biomolecular complexes and proteoforms, as long as they have the centrally targeted epitopes in common. While analytical cTnT immunoreactivity has been studied predominantly in blood, it can also be detected in urine, although it is unclear in which proteoform cTnT immunoreactivity is present in urine. This review presents an overview of the current knowledge on the pathophysiological lifecycle of cTnT. It provides insight into the impact of PTMs, not only on the analytical immunoreactivity, but also on the excretion of cTnT in urine as one of the waste routes in that lifecycle. Accordingly, and after isolating the proteoforms from urine of patients suffering from proteinuria and acute myocardial infarction, the structures of some possible cTnT proteoforms are reconstructed using mass spectrometry and presented.
- 1 May 2018
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 2 (6) , 857-867
Mass Spectrometric Identification of Cardiac Troponin T in Urine of Patients Suffering from Acute Myocardial Infarction
Background: Because of its high cardiospecificity, cardiac troponin T (cTnT) is one of the first-choice biomarkers to diagnose acute myocardial infarction (AMI). cTnT is extensively fragmented in serum of patients suffering from AMI. However, it is currently unknown whether all cTnT is completely degraded in the body or whether some cTnT fragments can leave the body via urine. The aim of the present study is to develop a method for the detection of cTnT in urine and to examine whether cTnT is detectable in patient urine. Methods: Proteins in urine samples of 20 patients were precipitated using a cTnT-specific immunoprecipitation technique and a nonspecific acetonitrile protein precipitation. After in-solution digestion of the precipitated proteins, the resulting peptides were separated and analyzed using HPLC and mass spectrometry with a targeted selected ion monitoring assay with data-dependent tandem mass spectrometry (t-SIM/dd-MS2). Results: The t-SIM/dd-MS2 assay was validated using a synthetic peptide standard containing 10 specific cTnT peptides of interest and with purified human intact cTnT spiked in urine from healthy individuals. Using this assay, 6 different cTnT-specific peptides were identified in urine samples from 3 different patients, all suffering from AMI. Conclusions: We show here for the first time that cTnT can be present in the urine of AMI patients using a targeted LC-MS/MS assay. Whether the presence of cTnT in urine reflects a physiological or pathophysiological process still needs to be elucidated.
- 1 May 2018
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 2 (6) , 857-867
Mass Spectrometric Identification of Cardiac Troponin T in Urine of Patients Suffering from Acute Myocardial Infarction
Background: Because of its high cardiospecificity, cardiac troponin T (cTnT) is one of the first-choice biomarkers to diagnose acute myocardial infarction (AMI). cTnT is extensively fragmented in serum of patients suffering from AMI. However, it is currently unknown whether all cTnT is completely degraded in the body or whether some cTnT fragments can leave the body via urine. The aim of the present study is to develop a method for the detection of cTnT in urine and to examine whether cTnT is detectable in patient urine. Methods: Proteins in urine samples of 20 patients were precipitated using a cTnT-specific immunoprecipitation technique and a nonspecific acetonitrile protein precipitation. After in-solution digestion of the precipitated proteins, the resulting peptides were separated and analyzed using HPLC and mass spectrometry with a targeted selected ion monitoring assay with data-dependent tandem mass spectrometry (t-SIM/dd-MS2). Results: The t-SIM/dd-MS2 assay was validated using a synthetic peptide standard containing 10 specific cTnT peptides of interest and with purified human intact cTnT spiked in urine from healthy individuals. Using this assay, 6 different cTnT-specific peptides were identified in urine samples from 3 different patients, all suffering from AMI. Conclusions: We show here for the first time that cTnT can be present in the urine of AMI patients using a targeted LC-MS/MS assay. Whether the presence of cTnT in urine reflects a physiological or pathophysiological process still needs to be elucidated.
- 1 July 2017
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 63 (7) , 1300-1302
Large Variation in Measured Cardiac Troponin T Concentrations after Standard Addition in Serum or Plasma of Different Individuals
To the Editor: During acute myocardial infarction (AMI), 1 cardiac troponin T (cTnT) is released from the damaged myocardium. One would expect a strong correlation between concentrations of cTnT measured in the blood after AMI and the extent of myocardial damage. However, various studies have shown a rather moderate correlation between infarct size and cTnT concentrations (1, 2). Frequently considered explanations for this phenomenon are methodological or focused on physiological factors associated with differences in release and elimination of cTnT (2). In contrast, less attention has been paid to the possible presence of inherent factors in the blood, such as (auto)antibodies or proteases, that might modify cTnT or interfere with the assay. We hypothesized that these factors may be ubiquitously present in the general population and might affect the measured concentrations of cTnT in individuals. We measured cTnT, cTnI, creatine kinase MB isoenzyme (CK-MB), and myoglobin concentrations in sera from 24 healthy volunteers (age range 22–54 years) before and after the addition of serum from a patient suffering from AMI (age 59 years, cTnT concentration approximately 19.5 μg/L). All participants gave written informed consent and leftover material was used in accordance with the code of proper secondary use of human tissue …
- 1 July 2017
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 63 (7) , 1300-1302
Large Variation in Measured Cardiac Troponin T Concentrations after Standard Addition in Serum or Plasma of Different Individuals
To the Editor: During acute myocardial infarction (AMI), 1 cardiac troponin T (cTnT) is released from the damaged myocardium. One would expect a strong correlation between concentrations of cTnT measured in the blood after AMI and the extent of myocardial damage. However, various studies have shown a rather moderate correlation between infarct size and cTnT concentrations (1, 2). Frequently considered explanations for this phenomenon are methodological or focused on physiological factors associated with differences in release and elimination of cTnT (2). In contrast, less attention has been paid to the possible presence of inherent factors in the blood, such as (auto)antibodies or proteases, that might modify cTnT or interfere with the assay. We hypothesized that these factors may be ubiquitously present in the general population and might affect the measured concentrations of cTnT in individuals. We measured cTnT, cTnI, creatine kinase MB isoenzyme (CK-MB), and myoglobin concentrations in sera from 24 healthy volunteers (age range 22–54 years) before and after the addition of serum from a patient suffering from AMI (age 59 years, cTnT concentration approximately 19.5 μg/L). All participants gave written informed consent and leftover material was used in accordance with the code of proper secondary use of human tissue …
- 1 November 2010
- Published by Elsevier in Clinical Biochemistry
- Vol. 43 (16-17) , 1371-1372
Gelofusine® affects the quality control performance of QuickVue® point-of-care human chorionic gonadotropin test devices
- 1 November 2010
- Published by Elsevier in Clinical Biochemistry
- Vol. 43 (16-17) , 1371-1372
Gelofusine® affects the quality control performance of QuickVue® point-of-care human chorionic gonadotropin test devices
- 18 November 2009
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (24) , 4047-4051
Implications of matrix adducts to protein analyte ions for surface‐enhanced laser desorption/ionization and matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometric analysis in clinical chemistry
- 18 November 2009
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 23 (24) , 4047-4051
Implications of matrix adducts to protein analyte ions for surface‐enhanced laser desorption/ionization and matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometric analysis in clinical chemistry