Claudine Fabre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Claudine Fabre has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Benoit Borel
Laboratoire HAVAE-UR20217, Université de Limoges, Limoges, France
3 shared publications Jean-Marie Grosbois
Centre Hospitalier Béthune, Service de Pneumologie et d'Allergologie, Rue Delbecque, Beuvry
2 shared publications- Aurélie Blaes
University of Lille Nord de France, UDSL, EA 4488, Physical Activity - Muscle - Health, Lille, France
1 shared publication - Baptiste Chéhère
EA 7369 - URePSSS - Multidisciplinary Research Unit in Sport Health Society, University of Lille, Lille, France
1 shared publication Benoit Wallaert
CHRU Lille - Service de Pneumologie et Immunoallergologie, Centre des Compétences des Maladies Pulmonaires Rares, Hôpital Calmette, CHRU Lille and Hospital Center Regional University De Lille, Lille
1 shared publicationDelphine Thevenet
M2S, ENS Cachan, Antenne de Bretagne Campus de Ker‐Lann, France Bruz France
1 shared publication
Latest Publications
- Open Access
- 1 May 2017
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 12, 1483-1489
Relationships between heart rate target determined in different exercise testing in COPD patients to prescribed with individualized exercise training
Background: It has been scientifically proven that pulmonary rehabilitation improves exercise tolerance and facilitates the carrying out of daily physical activities. To optimize the physical and physiological benefits, it is necessary to individualize the training intensity for each patient. The aim of this study is to compare the heart rate (HR) responses to three exercise modalities measuring aerobic fitness in chronic obstructive pulmonary disease patients, in order to easily prescribe individual target HRs for endurance training. Patients and method: Fifty COPD patients (mean age: 60.1±8.5 years) were included in the study. Each patient carried out a cardiopulmonary exercise test, a 6-minute walk test (6MWT) and a 6-minute stepper test (6MST). During these tests, HR was recorded continuously. After the cardiopulmonary exercise test, the HR was noted at the ventilatory threshold (VT) and at the end of the two exercise field tests (6MWTpeak and 6MSTpeak). The values of the HR during the last 3 minutes of both field tests were averaged (6MWT456 and 6MST456). Finally, the HR at 60% of the HR reserve was calculated with the values of the HR measured during 6MWT and 6MST (HRr60%walk, HRr60%step). Results: The HRs measured during the 6MST were significantly higher than those measured during the 6MWT. The HRr60%step was not significantly different from 6MWT456 and 6MWTpeak HR (P=0.51; P=0.48). A significant correlation was observed between 6MWT456 and 6MWTpeak (r=0.58). The 6MWT456 and 6MWTpeak HR were correlated with HRr60%step (r=0.68 and r=0.62). The VT could be determined in 28 patients. The HRVT was not different from 6MWT456, 6MWTpeak, and HRr60%step (P=0.57, P=0.41 and P=0.88) and was correlated to 6MWT456, 6MWTpeak, and HRr60%step (r=0.45, r=0.40, r=0.48). Conclusion: An individualized target HR for endurance training can be prescribed from the HR measured during routine tests, such as 6MWT or 6MST.
- 1 May 2017
- Published by Taylor & Francis in International Journal of Chronic Obstructive Pulmonary Disease
- Vol. ume 12, 1483-1489
Open AccessRelationships between heart rate target determined in different exercise testing in COPD patients to prescribed with individualized exercise training
Background: It has been scientifically proven that pulmonary rehabilitation improves exercise tolerance and facilitates the carrying out of daily physical activities. To optimize the physical and physiological benefits, it is necessary to individualize the training intensity for each patient. The aim of this study is to compare the heart rate (HR) responses to three exercise modalities measuring aerobic fitness in chronic obstructive pulmonary disease patients, in order to easily prescribe individual target HRs for endurance training. Patients and method: Fifty COPD patients (mean age: 60.1±8.5 years) were included in the study. Each patient carried out a cardiopulmonary exercise test, a 6-minute walk test (6MWT) and a 6-minute stepper test (6MST). During these tests, HR was recorded continuously. After the cardiopulmonary exercise test, the HR was noted at the ventilatory threshold (VT) and at the end of the two exercise field tests (6MWTpeak and 6MSTpeak). The values of the HR during the last 3 minutes of both field tests were averaged (6MWT456 and 6MST456). Finally, the HR at 60% of the HR reserve was calculated with the values of the HR measured during 6MWT and 6MST (HRr60%walk, HRr60%step). Results: The HRs measured during the 6MST were significantly higher than those measured during the 6MWT. The HRr60%step was not significantly different from 6MWT456 and 6MWTpeak HR (P=0.51; P=0.48). A significant correlation was observed between 6MWT456 and 6MWTpeak (r=0.58). The 6MWT456 and 6MWTpeak HR were correlated with HRr60%step (r=0.68 and r=0.62). The VT could be determined in 28 patients. The HRVT was not different from 6MWT456, 6MWTpeak, and HRr60%step (P=0.57, P=0.41 and P=0.88) and was correlated to 6MWT456, 6MWTpeak, and HRr60%step (r=0.45, r=0.40, r=0.48). Conclusion: An individualized target HR for endurance training can be prescribed from the HR measured during routine tests, such as 6MWT or 6MST.
- 13 June 2013
- Published by Wiley in Pediatric Pulmonology
- Vol. 49 (3) , 221-229
Mechanical ventilatory constraints during incremental exercise in healthy and cystic fibrosis children
Aim: To analyze breathing pattern and mechanical ventilatory constraints during incremental exercise in healthy and cystic fibrosis (CF) children.Methods: Thirteen healthy children and 6 children with cystic fibrosis volunteered to perform an incremental test on a treadmill. Exercise tidal flow/volume loops were plotted every minute within a maximal flow/volume loop (MFVL). Expiratory flow limitation (expFL expressed in %Vt) was evaluated and end‐expiratory and end‐inspiratory lung volumes (EELV and EILV) were estimated from expiratory reserve volume relative to vital capacity (ERV/FVC) and from inspiratory reserve volume relative to vital capacity (IRV/FVC).Results: During the incremental exercise, expFL was first observed at 40% of maximal aerobic speed in both groups. At maximal exercise, 46% of healthy children and 83% of CF children presented expFL, without significant effect of cystic fibrosis on the severity of expFL. According to the two‐way ANOVA results, both groups adopted similar breathing pattern and breathing strategies as no significant effect of CF has been revealed. But, according to one‐way ANOVA results, a significant increase of ERV/FVC associated with a significant decrease of IRV/FVC from resting value shave been observed in healthy children at maximal exercise, but not in CF children.Discussion: The hypothesis of this study was based on the assumption that mild cystic fibrosis could induce more frequent and more severe mechanical ventilatory constraints due to pulmonary impairment and breathing pattern disturbances. But, this study did not succeed to highlight an effect of mild cystic fibrosis on the mechanical ventilatory constraints (expFL and dynamic hyperinflation) that occur during an incremental exercise. This absence of effect could be due to the absence of an impact of the disease on spirometric data, breathing pattern regulation during exercise and breathing strategy. Pediatr Pulmonol. 2014; 49:221–229.
- 13 June 2013
- Published by Wiley in Pediatric Pulmonology
- Vol. 49 (3) , 221-229
Mechanical ventilatory constraints during incremental exercise in healthy and cystic fibrosis children
Aim: To analyze breathing pattern and mechanical ventilatory constraints during incremental exercise in healthy and cystic fibrosis (CF) children.Methods: Thirteen healthy children and 6 children with cystic fibrosis volunteered to perform an incremental test on a treadmill. Exercise tidal flow/volume loops were plotted every minute within a maximal flow/volume loop (MFVL). Expiratory flow limitation (expFL expressed in %Vt) was evaluated and end‐expiratory and end‐inspiratory lung volumes (EELV and EILV) were estimated from expiratory reserve volume relative to vital capacity (ERV/FVC) and from inspiratory reserve volume relative to vital capacity (IRV/FVC).Results: During the incremental exercise, expFL was first observed at 40% of maximal aerobic speed in both groups. At maximal exercise, 46% of healthy children and 83% of CF children presented expFL, without significant effect of cystic fibrosis on the severity of expFL. According to the two‐way ANOVA results, both groups adopted similar breathing pattern and breathing strategies as no significant effect of CF has been revealed. But, according to one‐way ANOVA results, a significant increase of ERV/FVC associated with a significant decrease of IRV/FVC from resting value shave been observed in healthy children at maximal exercise, but not in CF children.Discussion: The hypothesis of this study was based on the assumption that mild cystic fibrosis could induce more frequent and more severe mechanical ventilatory constraints due to pulmonary impairment and breathing pattern disturbances. But, this study did not succeed to highlight an effect of mild cystic fibrosis on the mechanical ventilatory constraints (expFL and dynamic hyperinflation) that occur during an incremental exercise. This absence of effect could be due to the absence of an impact of the disease on spirometric data, breathing pattern regulation during exercise and breathing strategy. Pediatr Pulmonol. 2014; 49:221–229.
- Open Access
- 4 November 2011
- Published by Springer Nature in International Journal of Behavioral Nutrition and Physical Activity
- Vol. 8 (1) , 122
Is there any relationship between physical activity level and patterns, and physical performance in children?
Background: It is often assumed that physical activity (PA) and physical performance during childhood and adolescence are beneficial for health during adulthood, but a positive relationship between PA and physical performance has not been precisely clarified in children. The lack or the weakness of the relationships between PA and physical performance could be due to the measure of PA. If the use of accelerometry is considered as an objective and common measure of PA, the real patterns of children's habitual PA must be reflected. The aim of this study was to investigate the relationship between the levels and patterns of PA assessed with high frequency accelerometry and physical performance in young children. Methods: Eighty-six boys and 101 girls aged 6-12 years participated in this study. Physical activity was measured over a 7-day period, using a 5-s epoch. Physical performance was assessed by means of EUROFIT tests (anthropometrics, standing broad jump, the 10 × 5 meter shuttle run, the sit-and-reach, the handgrip, the number of sit-ups in 30 seconds, the 20-meter shuttle run). Results: No relationship was found between PA and physical performance. In boys only, body fatness was negatively associated with vigorous PA (r = -0.38, p < 0.001) and very high PA (r = -0.35, p < 0.01), in contrast to light PA (r = 0.28, p < 0.01), which was positively related to body fatness. Conclusion: In 6- to- 12 year- old children, the more active children were not the fittest. Our results also underline the need for uniformity in approach to measurement of PA, body composition and health-related fitness between studies.
- 4 November 2011
- Published by Springer Nature in International Journal of Behavioral Nutrition and Physical Activity
- Vol. 8 (1) , 122
Open AccessIs there any relationship between physical activity level and patterns, and physical performance in children?
Background: It is often assumed that physical activity (PA) and physical performance during childhood and adolescence are beneficial for health during adulthood, but a positive relationship between PA and physical performance has not been precisely clarified in children. The lack or the weakness of the relationships between PA and physical performance could be due to the measure of PA. If the use of accelerometry is considered as an objective and common measure of PA, the real patterns of children's habitual PA must be reflected. The aim of this study was to investigate the relationship between the levels and patterns of PA assessed with high frequency accelerometry and physical performance in young children. Methods: Eighty-six boys and 101 girls aged 6-12 years participated in this study. Physical activity was measured over a 7-day period, using a 5-s epoch. Physical performance was assessed by means of EUROFIT tests (anthropometrics, standing broad jump, the 10 × 5 meter shuttle run, the sit-and-reach, the handgrip, the number of sit-ups in 30 seconds, the 20-meter shuttle run). Results: No relationship was found between PA and physical performance. In boys only, body fatness was negatively associated with vigorous PA (r = -0.38, p < 0.001) and very high PA (r = -0.35, p < 0.01), in contrast to light PA (r = 0.28, p < 0.01), which was positively related to body fatness. Conclusion: In 6- to- 12 year- old children, the more active children were not the fittest. Our results also underline the need for uniformity in approach to measurement of PA, body composition and health-related fitness between studies.
- 6 January 2010
- Published by SAGE Publications in Clinical Rehabilitation
- Vol. 24 (1) , 82-93
An original field evaluation test for chronic obstructive pulmonary disease population: the six-minute stepper test
Purpose: The aim of this study was to evaluate a new field test, the six-minute stepper test (6-MST), by studying its reproducibility, sensitivity and validity. Methods: After a familiarization test, 16 patients with chronic obstructive pulmonary disease (COPD) and 15 healthy subjects performed two six-minute stepper tests per day over three evaluation days. Ten of the 16 patients with COPD also performed a six-minute walking test (6-MWT) with an analysis of gas exchange to compare the metabolic requirements of the two tests. Dyspnoea Borg values were evaluated with Borg’s CR-10 scale. Results: The mean (SD) scores for the COPD group for the first and second six-minute stepper tests were 382.49 (106.01) and 412.45 (118.39) strokes/6 minutes, respectively. Crossed comparison between the first or the second six-minute stepper tests of each evaluation day revealed no significant difference, indicating the reproducibility of the test. The sensitivity was demonstrated by a significantly higher performance in the healthy group (P<0.001), demonstrating the ability of the test to detect two groups with different fitness levels. Finally, mean dyspnoea Borg values (SD) were significantly lower (P<0.05) during the six-minute stepper test than during 6-MWT (2.5 (1.5) versus 3.1 (1.2)). Conclusions: This study demonstrated that the six-minute stepper test is a reproducible, sensitive, secure, well-tolerated and feasible test for patients with COPD. The reproducibility and sensitivity of the six-minute stepper test suggests that this test could be used in the evaluation of exercise tolerance in patients with COPD.
- 6 January 2010
- Published by SAGE Publications in Clinical Rehabilitation
- Vol. 24 (1) , 82-93
An original field evaluation test for chronic obstructive pulmonary disease population: the six-minute stepper test
Purpose: The aim of this study was to evaluate a new field test, the six-minute stepper test (6-MST), by studying its reproducibility, sensitivity and validity. Methods: After a familiarization test, 16 patients with chronic obstructive pulmonary disease (COPD) and 15 healthy subjects performed two six-minute stepper tests per day over three evaluation days. Ten of the 16 patients with COPD also performed a six-minute walking test (6-MWT) with an analysis of gas exchange to compare the metabolic requirements of the two tests. Dyspnoea Borg values were evaluated with Borg’s CR-10 scale. Results: The mean (SD) scores for the COPD group for the first and second six-minute stepper tests were 382.49 (106.01) and 412.45 (118.39) strokes/6 minutes, respectively. Crossed comparison between the first or the second six-minute stepper tests of each evaluation day revealed no significant difference, indicating the reproducibility of the test. The sensitivity was demonstrated by a significantly higher performance in the healthy group (P<0.001), demonstrating the ability of the test to detect two groups with different fitness levels. Finally, mean dyspnoea Borg values (SD) were significantly lower (P<0.05) during the six-minute stepper test than during 6-MWT (2.5 (1.5) versus 3.1 (1.2)). Conclusions: This study demonstrated that the six-minute stepper test is a reproducible, sensitive, secure, well-tolerated and feasible test for patients with COPD. The reproducibility and sensitivity of the six-minute stepper test suggests that this test could be used in the evaluation of exercise tolerance in patients with COPD.
- 1 November 2007
- Published by Elsevier in Respiratory Medicine
- Vol. 101 (11) , 2305-2311
At identical isowork rates, ageing influences cardiorespiratory adaptations in COPD out-patients
- 1 November 2007
- Published by Elsevier in Respiratory Medicine
- Vol. 101 (11) , 2305-2311
At identical isowork rates, ageing influences cardiorespiratory adaptations in COPD out-patients