LGLeandro Cardoso Gomide

Leandro Cardoso Gomide

*This is an algorithmically generated author record based on publicly available information.

Leandro Cardoso Gomide has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Celso Eduardo Ribeiro Gonçalves Santos

    Orthopedist at Hospital Orthomedcenter, Uberlândia, MG, Brazil

    3 shared publications
  • Cleber Jesus Pereira

    Hospital Orthomedcenter, Uberlândia, Brasil

    3 shared publications
  • Dagoberto de Oliveira Campos

    Departamento de Cirurgia, Faculdade de Medicina, Universidade Federal de Uberlândia, Uberlândia, MG, Brasil

    3 shared publications
  • Daniel Barros Pereira

    Hospital Orthomedcenter, Uberlândia, Brasil

    3 shared publications
  • Luiz Cláudio Coelho Carvalho

    Hospital Orthomedcenter, Uberlândia, Brasil

    3 shared publications
  • Roberto da Cunha Luciano

    Orthopedist at Hospital Orthomedcenter, Uberlândia, MG, Brazil

    3 shared publications

Latest Publications

  • Open Access

    Estudo mecânico das propriedades dos fios de sutura usados em cirurgias ortopédicas

    by Leandro Cardoso Gomide, Dagoberto de Oliveira Campos, Cleudmar Amaral Araújo, Gabriela Lima Menegaz, Rafael Silva Cardoso, Sérgio Crosara Saad Júnior

    Resumo: Objetivo Avaliar as propriedades mecânicas dos fios de sutura normalmente usados nas cirurgias ortopédicas e caracterizar seu comportamento por meio de ensaios de tração para verificar qual deles apresenta maior resistência mecânica. Método Os ensaios de tração dos diferentes tipos de fios de sutura foram feitos na máquina de ensaios mecânicos BME 10 kN, com célula de carga de capacidade máxima de 50 kgf. Foram ensaiadas sete amostras de cada tipo de fio de sutura, foram fixadas cada uma das extremidades da amostra na garra metálica própria para o ensaio de fios e manteve-se o comprimento inicial de 5 cm. Os ensaios foram feitos com uma velocidade de 20 mm/minuto e à temperatura ambiente, registraram-se os dados de força máxima e o deslocamento máximo na ruptura dos fios. Resultados A força média de ruptura mais elevada foi observada na sutura FiberWire® 2 (Artrhex, Naples, FL, EUA) (240,17 N), seguida pela HiFi® 2 (Conmed, Utica, NY, EUA) (213,39 N) e Ethibond® 5 (Ethicon Inc., Somerville, NJ, EUA) (207,38 N). A menor força média de ruptura foi obtida para o fio Ethibond® 2 (Ethicon Inc., Somerville, NJ, EUA) (97,8 N). Conclusão Os fios de sutura não absorvíveis de polimistura trançada, de surgimento mais recente, são superiores ao fio de sutura convencional de poliéster trançado. O FiberWire® 2 é o mais resistente dos fios avaliados no presente estudo.


  • Open Access

    Prospective study of ultrasound-guided peri-plexus interscalene block with continuous infusion catheter for arthroscopic rotator cuff repair and postoperative pain control.

    by Leandro Cardoso Gomide, Roberto Araújo Ruzi, Beatriz Lemos Silva Mandim, Vanessa Alves da Rocha Dias, Rogério Henrique Dias Freire

    This trial investigated postoperative analgesia in arthroscopic rotator cuff repair surgery patients under general anesthesia, associated with ultrasound-guided peri-plexus interscalene brachial plexus block (US-IBPB), and compared single injection to elastomeric pump continuous infusion of local anesthetics. Complications associated to both techniques are described. In this prospective, quasi-randomized controlled clinical trial, 68 adults scheduled for elective arthroscopic rotator cuff repair were assigned to receive Group 1 (G1 = 41) US-IBPB with a 20 mL injection of 0.5% peri-plexus ropivacaine, introduction of catheter, injection of 20 mL of 0.5% ropivacaine through continuous catheter infusion of local anesthetic by elastomeric pump (ropivacaine 0.2%, infusion of 5 mL/h). In Group 2 (G2 = 27), US-IBPB, with a single peri-plexus injection of 40 mL ropivacaine 0.5%. In both groups oral analgesics were prescribed, paracetamol 500 mg associated to codeine 30 mg for patients with VAS between 3 and 5, and also oxycodone 20 mg for VAS ≥ 6. The anesthesiology team was available through contact telephones and the patients received a table to complete in order to report pain intensity according to VAS, use of oral medication, and complications related to the catheter and pump, until the third postoperative day. The intensity of pain was higher on second day after surgery than on days 1 and 3, in both groups confirmed by the ANOVA test (p = 0.00006) Among the groups, G1 patients had lower pain intensity than G2, (p = 0.000197). G2 patients presented greater pain intensity during all periods studied (days 1, 2, and 3) than G1 patients. Postoperatively, G2 patients had higher consumption of rescue analgesics, nausea, and vomiting (40.74%) vs. G1 (5%) and dizziness (25.92%). No patient with catheter and elastomeric pump (G1) had complications regarding its insertion and maintenance during postoperative period. The quality of analgesia for arthroscopic rotator cuff repair with peri-plexus US-IBPB and continuous infusion with elastomeric pump presented superior postoperative analgesia quality to single puncture IBPB on postoperative days 2 and 3, with lower consumption of rescue opioids in this period.


  • Open Access

    Relationship between the critical shoulder angle and the development of rotator cuff lesions: a retrospective epidemiological study

    by Leandro Cardoso Gomide, Thiago Correa Do Carmo, Guilherme Henrique Moreira Bergo, Glauber Araújo Oliveira, Igor Severino Macedo

    To perform a retrospective epidemiological study of radiographs in order to evaluate the relationship between the anatomy of the scapula and the development of rotator cuff injuries (RCIs). This study retrospectively evaluated the relation of the critical shoulder angle (CSA) and RCIs from January 2011 to November 2013; patients were examined in the Orthopedics and Traumatology Department of a university hospital. The CSA was measured by radiographic standardization of two groups: a control group of 34 asymptomatic shoulders and a study group of 44 shoulders with complete RCIs. The mean age in the control group was 59.97 years (45-84) and the mean age in the group with RCIs was 59.75 years (45-84). Regarding the CSA, the control group had a mean angle of 33.59° (±3.37) and the group with RCIs had a mean angle of 39.75° (±5.35; p < 0.007). There is an association between CSA and RCIs.


  • Open Access

    TERRIBLE TRIAD OF THE ELBOW: EVALUATION OF SURGICAL TREATMENT

    by Leandro Cardoso Gomide, Dagoberto de Oliveira Campos, José Maria Ribeiro de Sá, Marcelo Rangel Pamfílio de Sousa, Thiago Correa Do Carmo, Fernando Brandão Andrada

    Objectives: To evaluate the epidemiology of and surgical results from treating elbow fracture-dislocations, including only the cases in which dislocation is associated with fracture of the coronoid process and the radial head (terrible triad). Methods: Nineteen patients were evaluated: 12 males and 7 females. The medical records were analyzed to gather data about the mechanism of injury, fracture pattern, time elapsed until surgery and type of procedure applied. A clinical assessment was made to measure elbow range of motion, and the MEPS questionnaire was applied. Results: The most common mechanism of injury in our sample was a fall from a height (12 patients). All the patients underwent surgical treatment and the mean time elapsed between the date of the injury and the surgery was 16.1 days. The mean follow-up was 50.3 months. The mean range of flexion-extension obtained was 112° and the mean range of pronation-supination obtained was 127.9°. The mean score from the MEPS questionnaire was 86 points, and excellent and good results were obtained for 15 patients (79%). The time elapsed until surgery, final flexion-extension range greater than 100° and flexion contracture of less than 30° were shown to have a statistically significant relationship with a good final clinical result. Five patients had complications, of which three cases related to peripheral nerves, one case to pseudarthrosis and one case to recurrent instability. Conclusions: Despite the severity of the injuries found in the terrible triad of the elbow, most of the patients evaluated here achieved elbow stability with good clinical results. The factors that led to better clinical results were surgery not more than 14 days after the injury, flexion-extension range greater than 100° and flexion contracture less than 30°.


  • Open Access

    THIRD-DEGREE BURN IN THE REGION OF THE ELECTROSURGICAL PAD DURING SHOULDER ARTHROSCOPY: A CASE REPORT

    by Leandro Cardoso Gomide, Celso Eduardo Ribeiro Gonçalves Santos, Cleber Jesus Pereira, Luiz Cláudio Coelho Carvalho, Sérgio Antônio Souza Queiroz, Roberto da Cunha Luciano, Daniel Barros Pereira, Lélia Pereira Leocádio

    The number of shoulder arthroscopy procedures is increasing and, because of this, the frequency of related complications is also increasing. This report presents a case of third-degree burn from an electrosurgical pad during this procedure and serves as an alert regarding the possible causes and how to try to prevent this rare, but possible complication.


  • Open Access

    Tríade terrível do cotovelo: avaliação do tratamento cirúrgico

    by Leandro Cardoso Gomide, Dagoberto de Oliveira Campos, José Maria Ribeiro de Sá, Marcelo Rangel Pamfílio de Sousa, Thiago Correa Do Carmo, Fernando Brandão Andrada

    OBJETIVOS: Avaliar a epidemiologia e os resultados cirúrgicos do tratamento das fraturas-luxações de cotovelo, incluindo apenas os casos que associam a luxação com a fratura do processo coronoide e da cabeça do rádio (tríade terrível). MÉTODO: Foram avaliados 19 pacientes, sendo 12 do gênero masculino e sete do gênero feminino. Foi feita uma análise dos prontuários para coleta de dados a respeito do mecanismo do trauma, padrão das fraturas, tempo para a cirurgia e tipo de procedimento realizado. Foi realizada a avaliação clínica para mensuração dos arcos de movimento do cotovelo e aplicação do questionário MEPS. RESULTADOS: O mecanismo de trauma mais comum em nossa casuística foi a queda de altura (12 pacientes). Todos os pacientes foram submetidos a tratamento cirúrgico sendo que o tempo médio entre a data do trauma e a cirurgia foi de 16,1 dias. O seguimento médio foi de 50,3 meses. Foram obtidos arcos de flexo-extensão média de 112° e pronossupinação de 127,9°. A média do questionário MEPS foi de 86 pontos, sendo encontrados resultados excelentes e bons em 15 dos pacientes (79%). O tempo para a cirurgia, arco de flexoextensão final maior que 100° e a contratura em flexão menor que 30° se mostraram estatisticamente significantes para o bom resultado clínico final. Cinco pacientes tiveram complicações, sendo três em relação a nervos periféricos, uma pseudoartrose e uma instabilidade recorrente. CONCLUSÃO: Apesar da gravidade da lesão encontrada na tríade terrível do cotovelo, a maioria dos pacientes avaliados obteve um cotovelo estável com bons resultados clínicos. Os fatores que levam a melhores resultados clínicos são: cirurgia antes de 14 dias de lesão, arco de flexo-extensão maior que 100° e contratura em flexão menor que 30°. OBJECTIVES: To evaluate the epidemiology of and surgical results from treating elbow fracture-dislocations, including only the cases in which dislocation is associated with fracture of the coronoid process and the radial head (terrible trio). METHODS: Nineteen patients were evaluated: 12 males and 7 females. The medical records were analyzed to gather data about the mechanism of injury, fracture pattern, time elapsed until surgery and type of procedure applied. A clinical assessment was made to measure elbow range of motion, and the MEPS questionnaire was applied. RESULTS: The most common mechanism of injury in our sample was a fall from a height (12 patients). All the patients underwent surgical treatment and the mean time elapsed between the date of the injury and the surgery was 16.1 days. The mean follow-up was 50.3 months. The mean range of flexion-extension obtained was 112° and the mean range of pronation-supination obtained was 127.9°. The mean score from the MEPS questionnaire was 86 points, and excellent and good results were obtained for 15 patients (79%). The time elapsed until surgery, final flexion-extension range greater than 100° and flexion contracture of less than 30° were shown to have a statistically significant relationship with a good final clinical result. Five patients had complications, of which three cases related to peripheral nerves, one case to pseudarthrosis and one case to recurrent instability. CONCLUSIONS: Despite the severity of the injuries found in the terrible trio of the elbow, most of the patients evaluated here achieved elbow stability with good clinical results. The factors that led to better clinical results were surgery not more than 14 days after the injury, flexion-extension range greater than 100° and flexion contracture less than 30°


  • Open Access

    Queimadura de terceiro grau na região da placa eletrocirúrgica durante artroscopia de ombro: relato de caso

    by Leandro Cardoso Gomide, Celso Eduardo Ribeiro Gonçalves Santos, Cleber Jesus Pereira, Luiz Cláudio Coelho Carvalho, Sérgio Antônio Souza Queiroz, Roberto da Cunha Luciano, Daniel Barros Pereira, Lélia Pereira Leocádio

    O número de artroscopias de ombro está aumentando e, por causa disso, a frequência de complicações relacionadas também aumenta. O presente caso relata uma queimadura de terceiro grau na região da placa eletrocirúrgica durante esta cirurgia e alerta sobre possíveis causas e como tentar prevenir esta rara, mas possível complicação. The number of shoulder arthroscopy procedures is increasing and, because of this, the frequency of related complications is also increasing. This report presents a case of third-degree burn from an electrosurgical pad during this procedure and serves as an alert regarding the possible causes and how to try to prevent this rare, but possible complication