BPBruce D. Patterson

Bruce D. Patterson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bruce D. Patterson has a total of 110 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The SwissFEL soft X-ray free-electron laser beamline: Athos

    by Rafael Abela, Arturo Alarcon, Jürgen Alex, Christopher Arrell, Vladimir Arsov, Simona Bettoni, Markus Bopp, Christoph Bostedt, Hans Heinrich Braun, Marco Calvi, et al.

    The SwissFEL soft X-ray free-electron laser (FEL) beamline Athos will be ready for user operation in 2021. Its design includes a novel layout of alternating magnetic chicanes and short undulator segments. Together with the APPLE X architecture of undulators, the Athos branch can be operated in different modes producing FEL beams with unique characteristics ranging from attosecond pulse length to high-power modes. Further space has been reserved for upgrades including modulators and an external seeding laser for better timing control. All of these schemes rely on state-of-the-art technologies described in this overview. The optical transport line distributing the FEL beam to the experimental stations was designed with the whole range of beam parameters in mind. Currently two experimental stations, one for condensed matter and quantum materials research and a second one for atomic, molecular and optical physics, chemical sciences and ultrafast single-particle imaging, are being laid out such that they can profit from the unique soft X-ray pulses produced in the Athos branch in an optimal way.


  • Crystallography using an X-ray free-electron laser

    by Bruce D. Patterson

    An X-ray free-electron laser (XFEL) produces short pulses (10–50 fs) of intense (mJ μm−2 at 120 Hz) X-rays, with high transverse coherence. Such pulses open novel spectroscopic and scattering methods for static and time-resolved studies of matter, and many are based on X-ray crystallography. With serial femtosecond crystallography, the XFEL allows high-resolution structural determination on sub-micron protein crystals. Although the XFEL pulse is destructive, its short duration ensures that effectively undamaged material is probed. Coherent scattering features provide information on the physical crystal form and may assist in determining the crystallographic phase. By introducing synchronized optical laser pulses, one can perform ‘pump-probe’ measurements of dynamic properties, on the sub-picosecond timescale. These include photo-initiated structural modifications in biomolecules, photo-excited lattice vibrations and photo-driven structural phase transitions. As with synchrotron radiation, the XFEL wavelength can be tuned to atomic resonances, allowing time-resolved resonant-diffraction measurements, which are particularly sensitive to selected order parameters (lattice, charge, spin, and orbital) in magnetic or correlated electron materials. Finally, it is anticipated that the special properties of XFEL pulses will allow entirely new types of X-ray scattering measurements, such as ptychographic crystallography on 2D bio-crystals, correlation-function determination of nanoparticle geometry and nonlinear crystallographic mixing of optical and X-ray pulses.


  • Open Access

    Science Opportunities at the SwissFEL X-ray Laser

    by Bruce D. Patterson, Jakub Szlachentko, Bill Pedrini, Luc Patthey, Christopher Milne, Gerhard Ingold, Catherine Dejoiea, Hans H. Braun, Paul Beaud, Rafael Abela

    Next-generation X-ray sources, based on the X-ray Free Electron Laser (XFEL) concept, will provide highly coherent, ultrashort pulses of soft and hard X-rays with peak intensity many orders of magnitude higher than that of a synchrotron. These pulses will allow studies of femtosecond dynamics at nanometer resolution and with chemical selectivity. They will produce diffraction images of organic and inorganic nanostructures without deleterious effects of radiation damage.


  • Terahertz macrospin dynamics in insulating ferrimagnets

    by Mostafa Shalaby, Francois Vidal, Marco Peccianti, Roberto Morandotti, Florian Enderli, Thomas Feurer, Bruce D. Patterson

    We investigate numerically the excitation of nonlinear magnetic interactions in a ferrite material by an energetic pump pulse of terahertz (THz) radiation. The calculations are performed by solving the coupled Maxwell and Landau-Lifshitz-Gilbert differential equations. In a time-resolved THz pump/THz probe scheme, it is demonstrated that Faraday rotation of a delayed THz probe pulse can be used to map these interactions. Our study is motivated by the ability of soft x-ray free electron lasers to perform time-resolved imaging of the magnetization process at the submicrometer and subpicosecond length and time scales.


  • Open Access

    Can Energetic Terahertz Pulses Initiate Surface Catalytic Reactions on the Picosecond Time Scale?

    by Bruce D Patterson, Jacinto Sa, Anastasija Ichsanow, Christoph P Hauri, Carlo Vicario, Clemens Ruchert, Izabela Czekaj, Regula Gehrig, Hans C Sigg, Jeroen A Van Bokhoven, et al.

    In preparation for picosecond pump-probe experiments at the SwissFELX-ray laser facility, the feasibility of collectively initiating surface chemical reactions using energetic pulses of terahertz radiation is being tested.


  • Novel opportunities for time-resolved absorption spectroscopy at the X-ray free electron laser

    by B. D. Patterson, R. Abela

    Time-dependent X-ray Absorption Spectroscopy (XAS) measurements of chemical reaction dynamics have a time resolution which is limited by: (a) the speed and efficiency of the reaction initiation; (b) the duration of the X-ray pulses used for the measurement; and (c) the brightness of the X-ray source. X-Ray Free Electron Lasers (XFEL), which will deliver 20–100 fs pulses of X-rays, with a peak brightness which is 1010 times that of a synchrotron, will alleviate limitations (b) and (c). Furthermore, by including a synchronized source of UV, visible, IR or THz pump radiation, the XFEL will contribute to the solution of limitation (a). The present article describes the XFEL operating principle and the generic design of an XFEL facility, emphasizing the features of particular interest to the XAS investigator.


  • Open Access

    Coherent science at the SwissFEL x-ray laser

    by B D Patterson, R Abela, H-H Braun, U Flechsig, R Ganter, Y Kim, E Kirk, A Oppelt, M Pedrozzi, S Reiche, et al.

    The Paul Scherrer Institute is planning the construction of a hardx-ray free-electron laser, the SwissFEL, by 2016, which will produce intense, ultrashort pulses of transversely coherent radiation in the wavelength range 0.1-7 nm, with future extensions to cover the range 0.08-30 nm. Special design considerations include (a) a compact construction, compatible with the status of a national facility, (b) a uniform 100 Hz repetition rate, well suited to sample manipulations and detector readout, (c) flexible wavelength tuning by the electron beam energy and undulator gaps, (d) soft x-rays at approximately 1 nm wavelength, with circular polarization and Fourier-transform-limited pulses, (e) hard x-rays of pulse duration 5-20 fs and (f) an independent source of highenergy, half-cycle terahertz pump pulses. The science case for the Swiss FEL project, which emphasizes the dynamics of condensed matter systems and the damage-free imaging of nanostructures, includes novel considerations that make optimal use of these features.


  • Open Access

    Concentration Profiles of Colloidal Fluids in One-Dimensional Confinement

    by Oliver Bunk, Bernd Schmitt, Bruce D. Patterson, Philip R. Willmott, Celestino Padeste, Edith Perret, Kim Nygård, Christian David, Ana Diaza, Franz Pfeiffera, et al.

    An X-ray diffraction method has been developed to derive concentration profiles of fluids under one-dimensional confinement. A microfluidic array of channels is used as a container for the fluid under investigation. Thereby the ensemble average of many channels is studied rather than individual realizations of the system. Additionally, the X-ray scattering signal is enhanced and the radiation dose per fluid volume reduced. As an example, data are shown for a colloidal solution of silica particles of about 109 nm diameter under confinement in channels ranging from 280 to 615 nm width. The density profiles across the channels have been determined in a model independent way with a resolution in the 10 nm regime. When the electrostatic potential of the colloidal particles is shielded, we observe an oscillatory ordering-disordering behaviour of the colloidal particles as a function of the channel width, while the colloidal solution remains in the liquid state. This phenomenon has been suggested by surface force studies of hard-sphere fluids and also theoretically predicted, but has so far never been seen by direct measurements of the structure for comparable systems. The size of the fluid's constituents and of the confining cavities can be scaled down to below 100 nm, opening up the possibility for the investigation of confinement effects in e.g. protein crystallization.