Edward A. Essock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Edward A. Essock has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Andrew M. Haun
Department of Psychiatry, University of Wisconsin-Madison, Madison, USA
3 shared publications - Bruce C. Hansen
Colgate University
3 shared publications Michael J. Sinai
3 shared publicationsYufeng Zheng
Department of Advanced Technology Alcorn State University Alcorn State Mississippi
2 shared publicationsAachal Kotecha
Glaucoma Research Unit Moorfields Eye Hospital London United Kingdom
1 shared publicationAlexander Mrcophth Spratt
Glaucoma Research Unit Moorfields Eye Hospital London United Kingdom
1 shared publication
Latest Publications
- Open Access
- 1 August 2010
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 10 (10) , 1
Contrast sensitivity for oriented patterns in 1/f noise: Contrast response and the horizontal effect
When observers detect an oriented, broadband contrast increment on a background of 1/f spatial noise, thresholds will be lowest for obliquely orientated stimuli and highest for horizontally oriented stimuli—an anisotropy termed the “horizontal effect.” Here, we assessed what spatial frequencies within the broadband increment were relied on by observers in performing the original task and which spatial frequencies contribute to the anisotropic performance. We found that against a background of 1/f noise, contrast thresholds are lowest for content around 8 cycles per degree, and that at this spatial frequency a horizontal effect is seen which closely resembles the anisotropy observed in broadband masking. The magnitude of the horizontal effect decreased at lower and higher spatial frequencies. To allow for a fit to a standard “gain control” model of psychophysical contrast discrimination, threshold-versus-contrast (TvC) functions were measured for the 8-cpd noise broadband content against either an identical pattern (i.e., pedestal) or a broadband 1/f noise pattern, whose contrast was varied. Results and model application indicate that the threshold pattern for oriented noise around 8 cpd, and for oriented broadband content, is best explained as the result of an anisotropic contrast gain control process.
- 1 August 2010
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 10 (10) , 1
Open AccessContrast sensitivity for oriented patterns in 1/f noise: Contrast response and the horizontal effect
When observers detect an oriented, broadband contrast increment on a background of 1/f spatial noise, thresholds will be lowest for obliquely orientated stimuli and highest for horizontally oriented stimuli—an anisotropy termed the “horizontal effect.” Here, we assessed what spatial frequencies within the broadband increment were relied on by observers in performing the original task and which spatial frequencies contribute to the anisotropic performance. We found that against a background of 1/f noise, contrast thresholds are lowest for content around 8 cycles per degree, and that at this spatial frequency a horizontal effect is seen which closely resembles the anisotropy observed in broadband masking. The magnitude of the horizontal effect decreased at lower and higher spatial frequencies. To allow for a fit to a standard “gain control” model of psychophysical contrast discrimination, threshold-versus-contrast (TvC) functions were measured for the 8-cpd noise broadband content against either an identical pattern (i.e., pedestal) or a broadband 1/f noise pattern, whose contrast was varied. Results and model application indicate that the threshold pattern for oriented noise around 8 cpd, and for oriented broadband content, is best explained as the result of an anisotropic contrast gain control process.
- Open Access
- 1 January 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 9 (1) , 35
An anisotropy of orientation-tuned suppression that matches the anisotropy of typical natural scenes
Broadband oriented-noise masks were used to assess the orientation properties of spatial-context suppression in 'general' viewing conditions (i.e., a fixated, large field of 'naturalistic' noise). Suppression was orientation-tuned with a Gaussian shape and bandwidth of 40 degrees that was consistent across test orientation (0 degrees, 45 degrees, 90 degrees, and 135 degrees). Strength of suppression was highly anisotropic following a "horizontal effect" pattern (strongest suppression at horizontal and least suppression at oblique test orientations). Next, the time course of anisotropic masking was investigated by varying stimulus onset asynchrony (SOA). A standard "oblique effect" anisotropy is observed at long SOAs but becomes a "horizontal effect" when a noise mask is present within approximately 50 ms of the test onset. The orientation-tuned masking appears to result from an anisotropic gain-control mechanism that pools the weighted responses to the broadband mask, resulting in a changeover from oblique effect to horizontal effect. In addition, the relative magnitude of suppression at the orientations tested corresponds to the relative magnitudes of the content of typical natural scenes at the same orientations. We suggest that this anisotropic suppression may serve to equalize the visual system's response across orientation when viewing typical natural scenes, 'discounting' the anisotropy of typical natural scene content.
- 1 January 2009
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Journal of Vision
- Vol. 9 (1) , 35
Open AccessAn anisotropy of orientation-tuned suppression that matches the anisotropy of typical natural scenes
Broadband oriented-noise masks were used to assess the orientation properties of spatial-context suppression in 'general' viewing conditions (i.e., a fixated, large field of 'naturalistic' noise). Suppression was orientation-tuned with a Gaussian shape and bandwidth of 40 degrees that was consistent across test orientation (0 degrees, 45 degrees, 90 degrees, and 135 degrees). Strength of suppression was highly anisotropic following a "horizontal effect" pattern (strongest suppression at horizontal and least suppression at oblique test orientations). Next, the time course of anisotropic masking was investigated by varying stimulus onset asynchrony (SOA). A standard "oblique effect" anisotropy is observed at long SOAs but becomes a "horizontal effect" when a noise mask is present within approximately 50 ms of the test onset. The orientation-tuned masking appears to result from an anisotropic gain-control mechanism that pools the weighted responses to the broadband mask, resulting in a changeover from oblique effect to horizontal effect. In addition, the relative magnitude of suppression at the orientations tested corresponds to the relative magnitudes of the content of typical natural scenes at the same orientations. We suggest that this anisotropic suppression may serve to equalize the visual system's response across orientation when viewing typical natural scenes, 'discounting' the anisotropy of typical natural scene content.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10636919,p. 1-6
Thermal Imaging of the Superficial Temporal Artery: An Arterial Pulse Recovery Model
We present a novel model for measurement of the arterial pulse from the superficial temporal artery (STA) using passive thermal infrared (IR) sensors. The proposed approach has a physical and physiological basis and as such is of fundamental nature. Thermal IR camera is used to capture the heat pattern from superficial arteries, and a blood vessel model is used to describe the pulsatile nature of the blood flow. A multiresolution wavelet-based signal analysis approach is used to extract the arterial pulse waveform, which lends itself to various physiological measurements. We validate the results using a traditional contact vital-sign monitor as a ground truth. Eight people of different age, race and gender have been tested in our study consistent with IRB approval. The resultant arterial pulse waveforms exactly matched the ground-truth readings. The essence of our approach is the automatic detection of region of arterial pulse measurement (ROM), from which the arterial pulse waveform is extracted. To the best of our knowledge, the correspondence between non-contact thermal IR imaging based measurements of the arterial pulse in the time domain and traditional contact approaches has never been reported in the literature.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10636919,p. 1-6
Thermal Imaging of the Superficial Temporal Artery: An Arterial Pulse Recovery Model
We present a novel model for measurement of the arterial pulse from the superficial temporal artery (STA) using passive thermal infrared (IR) sensors. The proposed approach has a physical and physiological basis and as such is of fundamental nature. Thermal IR camera is used to capture the heat pattern from superficial arteries, and a blood vessel model is used to describe the pulsatile nature of the blood flow. A multiresolution wavelet-based signal analysis approach is used to extract the arterial pulse waveform, which lends itself to various physiological measurements. We validate the results using a traditional contact vital-sign monitor as a ground truth. Eight people of different age, race and gender have been tested in our study consistent with IRB approval. The resultant arterial pulse waveforms exactly matched the ground-truth readings. The essence of our approach is the automatic detection of region of arterial pulse measurement (ROM), from which the arterial pulse waveform is extracted. To the best of our knowledge, the correspondence between non-contact thermal IR imaging based measurements of the arterial pulse in the time domain and traditional contact approaches has never been reported in the literature.
- 1 May 2007
- Published by SAGE Publications in Perception
- Vol. 36 (5) , 639-649
Illusory Bands in Orientation and Spatial Frequency: A Cortical Analog to Mach Bands
Illusory bands at a luminance transition in space (ie an edge) are well known. Here we demonstrate illusory bands of enhanced orientations or spatial frequencies at transitions between higher-contrast and lower-contrast image content along the orientation and spatial-frequency dimensions—the dimensions of cortical spatial coding. We conclude that this illusion is a consequence of cortical-level suppression of units of similar orientations and spatial frequencies and serves to aid texture segmentation while providing efficient neural coding.
- 1 May 2007
- Published by SAGE Publications in Perception
- Vol. 36 (5) , 639-649
Illusory Bands in Orientation and Spatial Frequency: A Cortical Analog to Mach Bands
Illusory bands at a luminance transition in space (ie an edge) are well known. Here we demonstrate illusory bands of enhanced orientations or spatial frequencies at transitions between higher-contrast and lower-contrast image content along the orientation and spatial-frequency dimensions—the dimensions of cortical spatial coding. We conclude that this illusion is a consequence of cortical-level suppression of units of similar orientations and spatial frequencies and serves to aid texture segmentation while providing efficient neural coding.
- 1 May 2007
- Published by Wiley in Optometry and Vision Science
- Vol. 84 (5) , 380-7
Predicting Visual Field Loss in Ocular Hypertensive Patients Using Wavelet‐Fourier Analysis of GDx Scanning Laser Polarimetry
Purpose.: To predict which ocular hypertensive (OHT) patients later develop a visual field loss by applying shape‐based analysis (wavelet‐Fourier analysis, WFA) to retinal nerve fiber layer (RNFL) thickness estimates. Methods.: Visual field information and scanning laser polarimetry (SLP) RNFL estimates were obtained from both eyes of 122 patients (73 glaucoma and 49 OHT) and 102 healthy individuals. WFA was applied to RNFL temporal, superior nasal, inferior, and temporal (TSNIT) curves (28 points) of the glaucoma and healthy eyes to obtain a classifier. Without modification, the classifier was then applied to the OHT eyes (16 OHTconverters and 33 OHTnonconverters). The visual fields of the OHT patients (6‐month follow‐up for a mean period of 4 years) were analyzed using the Advanced Glaucoma Intervention Study (AGIS) criteria to identify eyes which developed subsequent field loss in this period of time (OHT converters) and those that did not (OHT nonconverters). For the OHT converters, the classifier was applied to scans from each of three points in time before the initial visual field damage. For the OHT nonconverters, the last available scan was used. The accuracy of the WFA metric in predicting conversion of OHT eyes was assessed by calculating area under the receiver operating characteristic (ROC) curve (area under the ROC curve, AUC), sensitivity at 80% specificity, and likelihood ratio. Results.: The performance (AUC) of WFA in predicting conversion of the OHT eyes from scans taken just before visual field loss was 0.83 with a sensitivity (SD)/specificity (SD) of 0.76 ± 0.11/0.80 ± 0.07 and likelihood ratio (+LR ± SD) of 3.8 ± 1.4. Performance for scans obtained 6 months before the first signs of visual field defects was 0.77 (AUC), 0.71 ± 0.11/0.80 ± 0.07 (sensitivity/specificity), and 3.5 ± 1.4 (+LR ± SD). Performance was 0.73 (AUC), 0.59 ± 0.12/0.8 ± 0.07 (sensitivity/specificity), and 3.0 ± 0.12 (+LR ± SD) using the earliest available RNFL estimates. Conclusion.: The WFA method of temporal, superior nasal, inferior, and temporal shape analysis offers a means of predicting progression in OHT patients before visual field loss.
- 1 May 2007
- Published by Wiley in Optometry and Vision Science
- Vol. 84 (5) , 380-7
Predicting Visual Field Loss in Ocular Hypertensive Patients Using Wavelet‐Fourier Analysis of GDx Scanning Laser Polarimetry
Purpose.: To predict which ocular hypertensive (OHT) patients later develop a visual field loss by applying shape‐based analysis (wavelet‐Fourier analysis, WFA) to retinal nerve fiber layer (RNFL) thickness estimates. Methods.: Visual field information and scanning laser polarimetry (SLP) RNFL estimates were obtained from both eyes of 122 patients (73 glaucoma and 49 OHT) and 102 healthy individuals. WFA was applied to RNFL temporal, superior nasal, inferior, and temporal (TSNIT) curves (28 points) of the glaucoma and healthy eyes to obtain a classifier. Without modification, the classifier was then applied to the OHT eyes (16 OHTconverters and 33 OHTnonconverters). The visual fields of the OHT patients (6‐month follow‐up for a mean period of 4 years) were analyzed using the Advanced Glaucoma Intervention Study (AGIS) criteria to identify eyes which developed subsequent field loss in this period of time (OHT converters) and those that did not (OHT nonconverters). For the OHT converters, the classifier was applied to scans from each of three points in time before the initial visual field damage. For the OHT nonconverters, the last available scan was used. The accuracy of the WFA metric in predicting conversion of OHT eyes was assessed by calculating area under the receiver operating characteristic (ROC) curve (area under the ROC curve, AUC), sensitivity at 80% specificity, and likelihood ratio. Results.: The performance (AUC) of WFA in predicting conversion of the OHT eyes from scans taken just before visual field loss was 0.83 with a sensitivity (SD)/specificity (SD) of 0.76 ± 0.11/0.80 ± 0.07 and likelihood ratio (+LR ± SD) of 3.8 ± 1.4. Performance for scans obtained 6 months before the first signs of visual field defects was 0.77 (AUC), 0.71 ± 0.11/0.80 ± 0.07 (sensitivity/specificity), and 3.5 ± 1.4 (+LR ± SD). Performance was 0.73 (AUC), 0.59 ± 0.12/0.8 ± 0.07 (sensitivity/specificity), and 3.0 ± 0.12 (+LR ± SD) using the earliest available RNFL estimates. Conclusion.: The WFA method of temporal, superior nasal, inferior, and temporal shape analysis offers a means of predicting progression in OHT patients before visual field loss.
- 1 August 2005
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 46 (8) , 2838-2847
Analysis of GDx-VCC Polarimetry Data by Wavelet-Fourier Analysis across Glaucoma Stages
Purpose. The purpose of this study was to apply shape-based analysis techniques of retinal nerve fiber layer (RNFL) thickness to GDx-VCC (variable corneal and lens compensator; Laser Diagnostic Technologies, Inc., San Diego, CA) polarimetry data and to evaluate the techniques’ ability to detect glaucoma in its earliest stages. Wavelet-based (wavelet-Fourier analysis [WFA]), Fourier-based (fast Fourier analysis [FFA]), and several previous variations of shape-based analysis were considered, as well as the standard metric nerve fiber indicator (NFI), and all were compared as a function of disease stage. methods. GDx-VCC scans of one eye of each of 67 patients with glaucoma and each of 67 healthy age-matched subjects provided RNFL thickness estimates at a fixed distance from the optic disc. Severity of disease was graded according to the Glaucoma Staging System and also by mean deviation (MD) from standard automated perimetry. WFA, FFA, and NFI procedures were performed including the following variations: use of signed or unsigned phase, inclusion of interocular or intraocular asymmetry of analysis parameters, and combination of features by principle components analysis or Wilks λ. Independent samples (k-fold variation) were used for training and testing. Sensitivity, specificity, and receiver operating characteristic (ROC) area were obtained. results. Classification performance of WFA (ROC = 0.978) was significantly better than FFA (ROC = 0.938) and NFI (ROC = 0.900). This difference was largest for the earliest stages of glaucoma. Shape-based analysis methods performed better than NFI overall. Adding between-eye asymmetry measures helped FFA but not WFA. conclusions. Shape-based analysis, and WFA in particular, makes an important improvement in detecting earliest glaucoma with polarimetry.
- 1 August 2005
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 46 (8) , 2838-2847
Analysis of GDx-VCC Polarimetry Data by Wavelet-Fourier Analysis across Glaucoma Stages
Purpose. The purpose of this study was to apply shape-based analysis techniques of retinal nerve fiber layer (RNFL) thickness to GDx-VCC (variable corneal and lens compensator; Laser Diagnostic Technologies, Inc., San Diego, CA) polarimetry data and to evaluate the techniques’ ability to detect glaucoma in its earliest stages. Wavelet-based (wavelet-Fourier analysis [WFA]), Fourier-based (fast Fourier analysis [FFA]), and several previous variations of shape-based analysis were considered, as well as the standard metric nerve fiber indicator (NFI), and all were compared as a function of disease stage. methods. GDx-VCC scans of one eye of each of 67 patients with glaucoma and each of 67 healthy age-matched subjects provided RNFL thickness estimates at a fixed distance from the optic disc. Severity of disease was graded according to the Glaucoma Staging System and also by mean deviation (MD) from standard automated perimetry. WFA, FFA, and NFI procedures were performed including the following variations: use of signed or unsigned phase, inclusion of interocular or intraocular asymmetry of analysis parameters, and combination of features by principle components analysis or Wilks λ. Independent samples (k-fold variation) were used for training and testing. Sensitivity, specificity, and receiver operating characteristic (ROC) area were obtained. results. Classification performance of WFA (ROC = 0.978) was significantly better than FFA (ROC = 0.938) and NFI (ROC = 0.900). This difference was largest for the earliest stages of glaucoma. Shape-based analysis methods performed better than NFI overall. Adding between-eye asymmetry measures helped FFA but not WFA. conclusions. Shape-based analysis, and WFA in particular, makes an important improvement in detecting earliest glaucoma with polarimetry.
- 1 January 2004
- Published by American Psychological Association (APA) in Journal of Experimental Psychology: Applied
- Vol. 10 (2) , 97-110
Human Perceptual Performance With Nonliteral Imagery: Region Recognition and Texture-Based Segmentation.
In this study the authors address the issue of how the perceptual usefulness of nonliteral imagery should be evaluated. Perceptual performance with nonliteral imagery of natural scenes obtained at night from infrared and image-intensified sensors and from multisensor fusion methods was assessed to relate performance on 2 basic perceptual tasks to fundamental characteristics of the imagery. Specifically, single-sensor imagery and fused multisensor imagery (both achromatic and false color) were used to test performance on a region recognition task and a texture segmentation task. Results indicate that the use of color rendering and type of scene content play specific roles in determining perceptual performance allowed by nonliteral imagery. The authors argue that the usefulness of various image-rendering methods should be evaluated with respect to multiple perceptual tasks.
- 1 January 2004
- Published by American Psychological Association (APA) in Journal of Experimental Psychology: Applied
- Vol. 10 (2) , 97-110
Human Perceptual Performance With Nonliteral Imagery: Region Recognition and Texture-Based Segmentation.
In this study the authors address the issue of how the perceptual usefulness of nonliteral imagery should be evaluated. Perceptual performance with nonliteral imagery of natural scenes obtained at night from infrared and image-intensified sensors and from multisensor fusion methods was assessed to relate performance on 2 basic perceptual tasks to fundamental characteristics of the imagery. Specifically, single-sensor imagery and fused multisensor imagery (both achromatic and false color) were used to test performance on a region recognition task and a texture segmentation task. Results indicate that the use of color rendering and type of scene content play specific roles in determining perceptual performance allowed by nonliteral imagery. The authors argue that the usefulness of various image-rendering methods should be evaluated with respect to multiple perceptual tasks.
- Open Access
- 1 September 2003
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 121 (9) , 1238-1245
Fourier Analysis of Optical Coherence Tomography and Scanning Laser Polarimetry Retinal Nerve Fiber Layer Measurements in the Diagnosis of Glaucoma
Research from JAMA Ophthalmology — Fourier Analysis of Optical Coherence Tomography and Scanning Laser Polarimetry Retinal Nerve Fiber Layer Measurements in the Diagnosis of Glaucoma
- 1 September 2003
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 121 (9) , 1238-1245
Open AccessFourier Analysis of Optical Coherence Tomography and Scanning Laser Polarimetry Retinal Nerve Fiber Layer Measurements in the Diagnosis of Glaucoma
Research from JAMA Ophthalmology — Fourier Analysis of Optical Coherence Tomography and Scanning Laser Polarimetry Retinal Nerve Fiber Layer Measurements in the Diagnosis of Glaucoma
- 1 June 2003
- Published by Elsevier in Vision Research
- Vol. 43 (12) , 1329-1335
Oblique stimuli are seen best (not worst!) in naturalistic broad-band stimuli: a horizontal effect
- 1 June 2003
- Published by Elsevier in Vision Research
- Vol. 43 (12) , 1329-1335
Oblique stimuli are seen best (not worst!) in naturalistic broad-band stimuli: a horizontal effect