Armin Luik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Armin Luik has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Claus Schmitt
Städtisches Klinikum Karlsruhe, Karlsruhe, Germany
10 shared publications Tobias Riexinger
4 shared publicationsClaus Schmitt
3 shared publicationsOlaf Dössel
Institute of Biomedical Engineering (IBT), Karlsruhe Institute of Technology, Karlsruhe, Germany
3 shared publicationsRainer Wondraschek
3 shared publicationsMatthias Merkel
2 shared publications
Latest Publications
- 13 September 2016
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 83 (9) , 462-473
Auswertung von Vibrometersignalen zur Bestimmung kardiovaskulärer Parameter
Zusammenfassung Laser-Doppler-Vibrometer (LDV) messen kleinste Schwingungsamplituden und haben neben technischen auch biomedizinische Anwendungen wie zum Beispiel die Schwingungsmessung auf der Haut. Die Überwachung des Herzrhythmus wird aktuell mit dem Elektrokardiogramm (EKG) durchgeführt, wobei Elektroden auf der Haut befestigt werden. Eine berührungslose Messung wäre vorteilhaft und würde die Patientenüberwachung (z. B. verbrannte Haut, Traumata auf dem Brustkorb, Frühgeborene und Athleten unter Belastung) erheblich vereinfachen. In diesem Beitrag zeigen wir, dass optische Vibrokardiographie (VKG) mit einem LDV nicht nur wie bereits bekannt die Herzfrequenz und deren Variabilität messen kann, sondern auch eine berührungslose Herzrhythmusmessung mit einer robusten atrioventrikulärer (AV) Block-Klassifikation ermöglicht, da der Herzschlag als mechanische Quelle zu Schwingungen auf der Haut führt. Dazu haben wir einen geeigneten Bereich auf dem Thorax identifiziert, der Schwingungen aufweist, die eindeutig dem Schließen von der linken Herzkammer und der linken Herzvorkammer zugeordnet werden können. Wir diskutieren außerdem verschiedene Signalverarbeitungskonzepte für eine automatische Signalmustererkennung von charakteristischen Signalabschnitten.
- 13 September 2016
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 83 (9) , 462-473
Auswertung von Vibrometersignalen zur Bestimmung kardiovaskulärer Parameter
Zusammenfassung Laser-Doppler-Vibrometer (LDV) messen kleinste Schwingungsamplituden und haben neben technischen auch biomedizinische Anwendungen wie zum Beispiel die Schwingungsmessung auf der Haut. Die Überwachung des Herzrhythmus wird aktuell mit dem Elektrokardiogramm (EKG) durchgeführt, wobei Elektroden auf der Haut befestigt werden. Eine berührungslose Messung wäre vorteilhaft und würde die Patientenüberwachung (z. B. verbrannte Haut, Traumata auf dem Brustkorb, Frühgeborene und Athleten unter Belastung) erheblich vereinfachen. In diesem Beitrag zeigen wir, dass optische Vibrokardiographie (VKG) mit einem LDV nicht nur wie bereits bekannt die Herzfrequenz und deren Variabilität messen kann, sondern auch eine berührungslose Herzrhythmusmessung mit einer robusten atrioventrikulärer (AV) Block-Klassifikation ermöglicht, da der Herzschlag als mechanische Quelle zu Schwingungen auf der Haut führt. Dazu haben wir einen geeigneten Bereich auf dem Thorax identifiziert, der Schwingungen aufweist, die eindeutig dem Schließen von der linken Herzkammer und der linken Herzvorkammer zugeordnet werden können. Wir diskutieren außerdem verschiedene Signalverarbeitungskonzepte für eine automatische Signalmustererkennung von charakteristischen Signalabschnitten.
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 259-262
Preprocessing of unipolar signals acquired by a novel intracardiac mapping system
The novel high-density mapping system RhythmiaTM Medical (Boston Scientific, Marlborough, USA) allows a fast and automatic acquisition of intracardiac electrograms (EGMs). For recording the ORION mini-basket catheter is used. Due to the small electrode surface, the spatial averaging is smaller than with other commonly used mapping catheters. This results in a higher quality of unipolar signals. However, these are still corrupted by noise such as high frequency interference. Within this project, methods were developed and benchmarked that can be applied to detect and remove these undesired components. An algorithm was implemented to detect and eliminate artificial peaks in the spectrum of the EGM. The filtered signals showed improved quality in time domain. The performance of the spectral peak detection resulted in a median sensitivity of 92.1% and in a median positive predictive value of 91.9%.
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 259-262
Open AccessPreprocessing of unipolar signals acquired by a novel intracardiac mapping system
The novel high-density mapping system RhythmiaTM Medical (Boston Scientific, Marlborough, USA) allows a fast and automatic acquisition of intracardiac electrograms (EGMs). For recording the ORION mini-basket catheter is used. Due to the small electrode surface, the spatial averaging is smaller than with other commonly used mapping catheters. This results in a higher quality of unipolar signals. However, these are still corrupted by noise such as high frequency interference. Within this project, methods were developed and benchmarked that can be applied to detect and remove these undesired components. An algorithm was implemented to detect and eliminate artificial peaks in the spectrum of the EGM. The filtered signals showed improved quality in time domain. The performance of the spectral peak detection resulted in a median sensitivity of 92.1% and in a median positive predictive value of 91.9%.
- Open Access
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 179-183
Automatic detection and mapping of double potentials in intracardiac electrograms
Catheter ablation has become a very efficient strategy to terminate sustained cardiac arrhythmias like atrial flutter (AFlut). Identification of the optimal ablation spot, however, often proves difficult when scar from previous ablations is present. Although the application of electro-anatomical mapping systems allows to record thousands of intracardiac electrograms (EGMs) from each atrium, state-of-the-art techniques provide limited options for automatic signal processing. Goal of the presented research was the development of an algorithm to detect EGMs that present double potentials (DPs), as these often indicate functional or anatomical lines of block for cardiac excitation. Using an annotated database, we developed several features based on the morphological descriptors of DPs. These were used to train a binary decision tree which was able to detect DPs with a correct rate of over 90%.
- 1 September 2016
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 2 (1) , 179-183
Open AccessAutomatic detection and mapping of double potentials in intracardiac electrograms
Catheter ablation has become a very efficient strategy to terminate sustained cardiac arrhythmias like atrial flutter (AFlut). Identification of the optimal ablation spot, however, often proves difficult when scar from previous ablations is present. Although the application of electro-anatomical mapping systems allows to record thousands of intracardiac electrograms (EGMs) from each atrium, state-of-the-art techniques provide limited options for automatic signal processing. Goal of the presented research was the development of an algorithm to detect EGMs that present double potentials (DPs), as these often indicate functional or anatomical lines of block for cardiac excitation. Using an annotated database, we developed several features based on the morphological descriptors of DPs. These were used to train a binary decision tree which was able to detect DPs with a correct rate of over 90%.
- 25 May 2012
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 25 (4) , 364-374
Acute and Late Outcomes of Transcatheter Aortic Valve Implantation (TAVI) for the Treatment of Severe Symptomatic Aortic Stenosis in Patients at High‐ and Low‐Surgical Risk
This prospective study examines the impact of EuroSCORE and transfemoral (TF) or transapical (TA) delivery approach on mortality at 30 days and 1 year in patients with severe aortic stenosis implanted with either the Edwards SAPIEN Transcatheter Heart Valve (THV) or Medtronic CoreValve. TAVI was successfully performed in 293 (97.7%) of 300 patients (TF: 174, TA: 126, mean EuroSCORE 24.0). The mortality at 30 days and after 1 year was 6.0% and 17.3%. Mortality depends significantly on the logistic EuroSCORE with a 30-day odds ratio (OR) of 1.92 (95% CI 1.41 to 2.62, P < 0.001) and after 1 year of 1.67 (95% CI 1.34 to 2.08, P < 0.001). Mortality in patients with a logistic EuroSCORE <15 (n = 113) or ≥15 (n = 187) at 30 days was 0.9% versus 9.1% and after 1 year 7.1% versus 23.5% demonstrating significantly less mortality (P < 0.001) in patients with lower logistic EuroSCOREs. In this specific setup of our center there was no significant difference (P = 0.553) in mortality regarding the technical approach for TA (4.0% and 15.9%) and for TF (7.5% and 18.4%). Severe cardiac complications occurred in 20 patients (6.7%) with a 30-day mortality of 45.0%. The mortality in patients undergoing TAVI correlates significantly with the logistic EuroSCORE. Patients with a logistic EuroSCORE <15 can be implanted, with a low 30-day mortality and good long-term outcome over 1 year.
- 25 May 2012
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 25 (4) , 364-374
Acute and Late Outcomes of Transcatheter Aortic Valve Implantation (TAVI) for the Treatment of Severe Symptomatic Aortic Stenosis in Patients at High‐ and Low‐Surgical Risk
This prospective study examines the impact of EuroSCORE and transfemoral (TF) or transapical (TA) delivery approach on mortality at 30 days and 1 year in patients with severe aortic stenosis implanted with either the Edwards SAPIEN Transcatheter Heart Valve (THV) or Medtronic CoreValve. TAVI was successfully performed in 293 (97.7%) of 300 patients (TF: 174, TA: 126, mean EuroSCORE 24.0). The mortality at 30 days and after 1 year was 6.0% and 17.3%. Mortality depends significantly on the logistic EuroSCORE with a 30-day odds ratio (OR) of 1.92 (95% CI 1.41 to 2.62, P < 0.001) and after 1 year of 1.67 (95% CI 1.34 to 2.08, P < 0.001). Mortality in patients with a logistic EuroSCORE <15 (n = 113) or ≥15 (n = 187) at 30 days was 0.9% versus 9.1% and after 1 year 7.1% versus 23.5% demonstrating significantly less mortality (P < 0.001) in patients with lower logistic EuroSCOREs. In this specific setup of our center there was no significant difference (P = 0.553) in mortality regarding the technical approach for TA (4.0% and 15.9%) and for TF (7.5% and 18.4%). Severe cardiac complications occurred in 20 patients (6.7%) with a 30-day mortality of 45.0%. The mortality in patients undergoing TAVI correlates significantly with the logistic EuroSCORE. Patients with a logistic EuroSCORE <15 can be implanted, with a low 30-day mortality and good long-term outcome over 1 year.
- 1 June 2011
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 7 (02) , 141-150
Typisches und atypisches Vorhofflattern
Atrial flutter is a common arrhythmia. It is a macroreentry tachycardia encircling the tricuspid valve (common type) or other structures (uncommon type). Due to a limited efficacy of the current available medical treatment, catheter ablation of atrial flutter has gained growing importance as an effective and possible curative treatment. Whereas the ablation of common type atrial flutter is well established and nowadays routine in every EP lab, the ablation of uncommon type atrial flutter is still challenging.
- 1 June 2011
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 7 (02) , 141-150
Typisches und atypisches Vorhofflattern
Atrial flutter is a common arrhythmia. It is a macroreentry tachycardia encircling the tricuspid valve (common type) or other structures (uncommon type). Due to a limited efficacy of the current available medical treatment, catheter ablation of atrial flutter has gained growing importance as an effective and possible curative treatment. Whereas the ablation of common type atrial flutter is well established and nowadays routine in every EP lab, the ablation of uncommon type atrial flutter is still challenging.
- 1 March 2011
- Published by Elsevier in Journal of Electrocardiology
- Vol. 44 (2) , e14
Quantitative determination of wave direction and conduction velocity in the human atrium from intracardiac electrograms
- 1 March 2011
- Published by Elsevier in Journal of Electrocardiology
- Vol. 44 (2) , e14
Quantitative determination of wave direction and conduction velocity in the human atrium from intracardiac electrograms
- 1 March 2011
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 7 (01) , 15-21
Update der ESC-Leitlinie zum Management des Vorhofflimmerns
The 2010 Update of the European Society of Cardiology (ESC) guidelines for management of atrial fibrillation have been published. In this Hotline article a short summary is given of these new guidelines. They provide an effective tool for making evidence based decisions on therapy. The guidelines contain a number of new elements. A new type of atrial fibrillation named long-persisting atrial fibrillation has been identified. The guidelines contain recommendations on the use of antithrombotic therapy and heart rate control. A strict antithrombotic therapy with vitamin K antagonist is advised. The guidelines include a series of new scores as the extension of the CHADS2 via the CHA2DS2-VASc-Score for the estimation of thromboembolic risk. There is a further update on the new EHRA Score for the classification of the symptoms of the patients during atrial fibrillation and the HAS-Bled Score assessing the bleeding risk. Based on the results of the RACE II trial the rate control can be adjusted. The trial has shown that in the patients enrolled in RACE II a lenient rate control therapy is reasonable compared to strict rate control under 80 beats per minute. Dronedarone was established in the guidelines as first line therapy. Catheter ablation can be considered as an initial therapy in symptomatic patients with paroxysmal AF and minimal or no heart disease (hypertension and no left-ventricular hypertrophy).
- 1 March 2011
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 7 (01) , 15-21
Update der ESC-Leitlinie zum Management des Vorhofflimmerns
The 2010 Update of the European Society of Cardiology (ESC) guidelines for management of atrial fibrillation have been published. In this Hotline article a short summary is given of these new guidelines. They provide an effective tool for making evidence based decisions on therapy. The guidelines contain a number of new elements. A new type of atrial fibrillation named long-persisting atrial fibrillation has been identified. The guidelines contain recommendations on the use of antithrombotic therapy and heart rate control. A strict antithrombotic therapy with vitamin K antagonist is advised. The guidelines include a series of new scores as the extension of the CHADS2 via the CHA2DS2-VASc-Score for the estimation of thromboembolic risk. There is a further update on the new EHRA Score for the classification of the symptoms of the patients during atrial fibrillation and the HAS-Bled Score assessing the bleeding risk. Based on the results of the RACE II trial the rate control can be adjusted. The trial has shown that in the patients enrolled in RACE II a lenient rate control therapy is reasonable compared to strict rate control under 80 beats per minute. Dronedarone was established in the guidelines as first line therapy. Catheter ablation can be considered as an initial therapy in symptomatic patients with paroxysmal AF and minimal or no heart disease (hypertension and no left-ventricular hypertrophy).
- 1 June 2010
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 6 (02) , 96-99
Tachykardie mit breitem QRS-Komplex – ein ungewöhnlicher Fall
Ventricular non-reentrant idiopathic tachycardia (VT) is characterized by an inferior axis and a left bundle branch block pattern in the surface ECG. Thereby the R/S transition is important. While R/S transition in V1 or V2 is typically for a left-sided origin, an R/S transition in V4 or beyond is typically associated with a right-sided origin. The right ventricular outflow tract (RVOT) is the predominant origin of this VT but is also found at left ventricular outflow tract (LVOT). The prognosis is generally good compared to other VT-types. This case highlights a successful epicardial ablation of a ventricular outflow tract tachycardia via an endocardial approach from the coronary sinus without causing any complications.
- 1 June 2010
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 6 (02) , 96-99
Tachykardie mit breitem QRS-Komplex – ein ungewöhnlicher Fall
Ventricular non-reentrant idiopathic tachycardia (VT) is characterized by an inferior axis and a left bundle branch block pattern in the surface ECG. Thereby the R/S transition is important. While R/S transition in V1 or V2 is typically for a left-sided origin, an R/S transition in V4 or beyond is typically associated with a right-sided origin. The right ventricular outflow tract (RVOT) is the predominant origin of this VT but is also found at left ventricular outflow tract (LVOT). The prognosis is generally good compared to other VT-types. This case highlights a successful epicardial ablation of a ventricular outflow tract tachycardia via an endocardial approach from the coronary sinus without causing any complications.
- 1 June 2010
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 6 (02) , 153-167
Typisches und atypisches Infarkt-EKG und das Pseudo-Infarkt-EKG
The ECG remains the most important tool in the diagnosis of acute myocardial infarction. Algorithms are discussed for differentiation of proximal vs distal LAD occlusion as well as differentiation of RCA vs LCX occlusion. A normal ECG does not exclude an acute myocardial infarction, e. g. in 50 % of occlusion of LCX no ST-segment elevation is found. Diagnosis of acute myocardial infarction in patients with left bundle branch block remains a problem, concordant ST-segment-depression or – elevation is most valuable. Pseudoinfarct patterns are found most often in patients with hyperkalemia, perikarditis, pulmonary embolism, hypertrophic cardiomyopathy and preexcitation syndromes.
- 1 June 2010
- Published by Georg Thieme Verlag KG in Kardiologie up2date
- Vol. 6 (02) , 153-167
Typisches und atypisches Infarkt-EKG und das Pseudo-Infarkt-EKG
The ECG remains the most important tool in the diagnosis of acute myocardial infarction. Algorithms are discussed for differentiation of proximal vs distal LAD occlusion as well as differentiation of RCA vs LCX occlusion. A normal ECG does not exclude an acute myocardial infarction, e. g. in 50 % of occlusion of LCX no ST-segment elevation is found. Diagnosis of acute myocardial infarction in patients with left bundle branch block remains a problem, concordant ST-segment-depression or – elevation is most valuable. Pseudoinfarct patterns are found most often in patients with hyperkalemia, perikarditis, pulmonary embolism, hypertrophic cardiomyopathy and preexcitation syndromes.