TWThomas J. Wolfensberger

Thomas J. Wolfensberger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Thomas J. Wolfensberger has a total of 95 co-authors. Here are the top co-authors by number of shared publications:

  • Alejandra Daruich

    Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Switzerland

    3 shared publications
  • Bao Khanh Tran

    Policlinic, Hopital Ophtalmique Jules Gonin, University of Lausanne, Lausanne, Switzerland

    3 shared publications
  • Ciara Bergin

    Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Switzerland

    3 shared publications
  • Clarice Giacuzzo

    Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Switzerland

    3 shared publications
  • Jelena Potic

    Hôpital Jules Gonin, 1004 Lausanne, Switzerland

    3 shared publications
  • Lazaros Konstantinidis

    Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Switzerland

    3 shared publications

Latest Publications

  • Open Access

    Accuracy of Autonomous Artificial Intelligence-Based Diabetic Retinopathy Screening in Real-Life Clinical Practice

    by Eleonora Riotto, Stefan Gasser, Jelena Potic, Mohamed Sherif, Theodor Stappler, Reinier Schlingemann, Thomas Wolfensberger, Lazaros Konstantinidis

    Background: In diabetic retinopathy, early detection and intervention are crucial in preventing vision loss and improving patient outcomes. In the era of artificial intelligence (AI) and machine learning, new promising diagnostic tools have emerged. The IDX-DR machine (Digital Diagnostics, Coralville, IA, USA) represents a diagnostic tool that combines advanced imaging techniques, AI algorithms, and deep learning methodologies to identify and classify diabetic retinopathy. Methods: All patients that participated in our AI-based DR screening were considered for this study. For this study, all retinal images were additionally reviewed retrospectively by two experienced retinal specialists. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated for the IDX-DR machine compared to the graders’ responses. Results: We included a total of 2282 images from 1141 patients who were screened between January 2021 and January 2023 at the Jules Gonin Eye Hospital in Lausanne, Switzerland. Sensitivity was calculated to be 100% for ‘no DR’, ‘mild DR’, and ‘moderate DR’. Specificity for no DR’, ‘mild DR’, ‘moderate DR’, and ‘severe DR’ was calculated to be, respectively, 78.4%, 81.2%, 93.4%, and 97.6%. PPV was calculated to be, respectively, 36.7%, 24.6%, 1.4%, and 0%. NPV was calculated to be 100% for each category. Accuracy was calculated to be higher than 80% for ‘no DR’, ‘mild DR’, and ‘moderate DR’. Conclusions: In this study, based in Jules Gonin Eye Hospital in Lausanne, we compared the autonomous diagnostic AI system of the IDX-DR machine detecting diabetic retinopathy to human gradings established by two experienced retinal specialists. Our results showed that the ID-x DR machine constantly overestimates the DR stages, thus permitting the clinicians to fully trust negative results delivered by the screening software. Nevertheless, all fundus images classified as ‘mild DR’ or greater should always be controlled by a specialist in order to assert whether the predicted stage is truly present.


  • Long-Term Follow-Up of Recurrent Spontaneous Hyphema Caused by Ruptured Persistent Fetal Vasculature

    by Emmanuelle Moret, Raphaël Wuarin, Ann Schalenbourg, Thomas J. Wolfensberger

    Persistent fetal vasculature (PFV) is a failure of regression of fetal intraocular vasculature during intrauterine life. Its clinical manifestation is variable among patients, depending on the subtype of PFV – anterior, posterior, or combined PFV [1], [2]. In particular, persistent pupillary membranes are part of anterior PFV. These vessels are remnants of the anterior tunica vasculosa lentis and are variably perfused from the minor arterial circle of the iris at the level of the collarette. Rarely, persistent pupillary membranes can cause recurrent hyphema in adults [3], [4], [5], [6], [7], [8]. We report the medical management and the long-term follow-up of an adult woman with recurrent spontaneous hyphema caused by a ruptured remnant of a persistent pupillary membrane. Received: 24 September 2021 Accepted: 09 January 2022 Publication Date: 26 April 2022 (online) © 2022. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

  • Open Access

    INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR MACULAR HOLE COEXISTENT WITH RHEGMATOGENOUS RETINAL DETACHMENT

    by Theodor Md Stappler, Andrea Montesel, Lazaros Konstantinidis, Thomas J. Wolfensberger, Chiara M. Eandi

    Purpose: To report the clinical features and treatment outcomes of patients with macular hole coexistent with rhegmatogenous retinal detachment surgically treated with pars plana vitrectomy and inverted internal limiting membrane flap technique. Methods: Eleven consecutive patients with rhegmatogenous retinal detachment and macular hole who underwent vitrectomy and internal limiting membrane peeling with the inverted flap technique between December 2017 and February 2021 were retrospectively evaluated. The main outcome measures were retinal reattachment rate, macular hole closure rate, and postoperative best-corrected visual acuity. A nonsystematic literature review was performed to compare the study outcomes with those previously reported. Results: The primary retinal reattachment rate was 90% (10/11) with one surgery and 100% with 2 surgical procedures. Macular hole closure was achieved in all patients (11/11). All patients showed an improvement in visual acuity at the final postoperative visit, and the mean postoperative best-corrected visual acuity was 0.60 ± 0.32 logarithm of the minimum angle of resolution (20/80 Snellen equivalent). Conclusion: Vitrectomy with the inverted internal limiting membrane flap technique achieved not only favorable anatomical retinal reattachment rates but also an encouraging recovery of central macular anatomy and visual function in patients with macular hole coexistent with rhegmatogenous retinal detachment.


  • Open Access

    APPLICATION OF MODIFIED NEI VFQ-25 AFTER RETINAL DETACHMENT TO VISION-RELATED QUALITY OF LIFE

    by Jelena Potic, Ciara Bergin, Clarice Giacuzzo, Lazaros Konstantinidis, Alejandra Daruich, Thomas J. Wolfensberger

    Purpose: We examined the postoperative visual recovery and quality of life after retinal detachment (RD) surgery. Methods: In addition to a baseline clinical examination, patients filled out the National Eye Institute Visual Functioning Questionnaire at three time points: preoperatively and 1 and 3 months postoperatively (M1 and M3, respectively). We analyzed the composite score and short-form scores (socioemotional scale [SFSES] and visual functioning scale [SFVFS]). Results: One hundred ninety-four patients were enrolled in this study; 47 (26 macula-ON RD and 21 macula-OFF RD) returned all three questionnaires. The best corrected visual acuity was Snellen equivalent 20/25, 20/25, and 20/20 at the preoperative, M1, and M3 assessment, respectively. At M3, we found a positive correlation between SFSES and best corrected visual acuity measures among macula-OFF patients (P < 0.001, R2 = 0.58). A significant correlation with the best corrected visual acuity among macula-ON patients was observed only at M3 with the SFVFS score (P < 0.001, R2 = 0.41). Conclusion: The quality of life differs between ON and OFF RD in regard to the composite score and especially SFSES and SFVFS. We found a transient decrease in the quality of life at M1 for macula-ON patients, whereas the quality of life improved throughout follow-up among macula-OFF patients. These data may help improve the management of patients' expectations after RD surgery.


  • Open Access

    EVOLUTION AND PATTERNS OF CHOROIDAL THICKNESS CHANGES IN RHEGMATOGENOUS RETINAL DETACHMENT

    by Clarice Giacuzzo, Ciara Bergin, Jelena Potic, Edwige Forestier, Alejandra Daruich, Jean-Antoine Pournaras, Lazaros Konstantinidis, Thomas J. Wolfensberger

    Purpose: To evaluate the changes in choroidal thickness (CT) before and after a successful pars plana vitrectomy for rhegmatogenous retinal detachment (RD), and to compare the evolution of CT with respect to the extent of RD. Methods: Fifty-four patients were divided into three groups: peripheral macula-on RD (>3 mm from the fovea; 14 eyes); paracentral macula-on RD (fovea-sparing; ≤3 mm from the fovea; 14 eyes); and macula-off RD (involving the fovea; 26 eyes). Choroidal thickness was measured at 1 month (M1) and 3 months (M3) postoperatively, preoperatively in macula-on RDs, with enhanced depth imaging optical coherence tomography, from the nasal side (+2.5 mm) to the temporal side (−2.5 mm) of the fovea. Results: In peripheral macula-on RD, the intereye difference in CTs showed thickening throughout follow-up (subfoveally: preoperatively = 19.6% ± 43.9%, M1 = 22.9% ± 27.5%, M3 = 18.2% ± 35.6%). In paracentral macula-on RD, the intereye difference in CTs showed a thinning throughout follow-up (subfoveally: preoperatively = −7.8% ± 21.9%, M1 =−5.5% ± 26.1%, M3 = −9.3% ± 19.4%), as well as in the macula-off RD (subfoveally: M1 = −14.1% ± 18.7%, M3 = −9.9% ± 15%). Conclusion: The extent of RD was related to the evolution of the CT before and after surgery. Further studies are necessary to clarify the relationship between the changes in CT and the effects of circulatory alterations, vitrectomy, and RD.


  • Programmable Multistable Mechanisms for Safe Surgical Puncturing

    by Mohamed Zanaty, Thomas Fussinger, Arno Rogg, Andrea Lovera, David Lambelet, Ilan Vardi, Thomas J. Wolfensberger, Charles Baur, Simon Henein

    We present novel medical devices for safe surgical puncturing, in particular a cannula for the treatment of retinal vein occlusion (RVO). This passive mechanical device has an adjustable stroke and exerts a puncturing force independent of operator applied displacement. The innovative feature of this tool is that puncturing stroke is decoupled from operator input thereby minimizing the possibility of overpuncturing. This is achieved using our concept of stability programming, where the user modifies the mechanism strain energy as opposed to imposing direct displacement which is the case for standard bistable mechanisms. Ultra-fast laser three-dimensional (3D) printing is used to manufacture the needle in glass. A microfluidic channel is integrated into the needle tip for drug injection. Numerical simulations and experimental measurements validate the mechanical stability behavior of the puncture mechanism and characterize its puncturing stroke and force.


  • Management of Anterior Chamber Dislocation of a Dexamethasone Implant

    by Thi Lyly Nguyen, Thomas J. Wolfensberger

    Purpose To characterise the surgical removal technique of a dislocated dexamethasone implant in the anterior chamber and to gauge its success by analysing corneal transparency and subsequent visual acuity recovery in the postoperative phase. Methods Description of a patient who presented with an anterior chamber dexamethasone implant migration through an inferior iridotomy performed previously for a silicone oil fill in aphakia. Visual acuity had dropped to counting fingers due to marked corneal oedema. Results The implant was removed using a 23-g needle aligned with the axis of the implant through a paracentesis. After the clinical follow-up at 2 months, best-corrected visual acuity had returned to 0.2, which remained stable at the last follow-up at 14 months with an intraocular pressure of 10 mmHg. The corneal oedema resolved completely. Conclusion This novel surgical management of a dexamethasone implant dislocation into the anterior chamber was successful and resulted in no long-term corneal damage when the implant was removed without delay. A repeated Ozurdex injection in patients with previous inferior iridotomy may require prior suturing of the iridotomy. Zielsetzung Charakterisierung einer chirurgischen Technik, um ein disloziertes Ozurdex-Implantat aus der Vorderkammer zu entfernen und den Erfolg mit der Analyse der Hornhauttransparenz und Sehverbesserung zu dokumentieren. Methoden Beschreibung eines Patienten mit einem durch eine basale Iridotomie in die Vorderkammer luxierten Dexamethason-Implantat. Aufgrund eines ausgedehnten Hornhautödems betrug die Sehschärfe Fingerzählen. Resultate Das Implantat wurde mittels einer 23-g-Nadel, welche nach der Achse des Implantats ausgerichtet war, durch eine Parazentese aspiriert. Nach einer klinischen Nachkontrollzeit von 2 Monaten betrug die Sehschärfe wiederum 0,2, die während 14 Monaten Nachkontrolle stabil blieb. Das Hornhautödem verschwand. Schlussfolgerung Diese neuartige chirurgische Technik erlaubt die einfache Entfernung eines in die Vorderkammer luxierten Dexamethason-Implantats ohne langfristige Hornhautkomplikationen. Bei Patienten mit inferiorer Iridotomie und wiederholter Dexamethason-Implantat-Injektion muss ein Nahtverschluss der Iridotomie diskutiert werden.


  • Surgical Management of Intraocular Silicone Oil Microdroplet

    by Antoine Safi, Thomas J. Wolfensberger

    Purpose Intraocular silicone oil microdroplets have been described after intravitreal injection of anti-VEGF agents packaged at a compound pharmacy. We present a case with the presence of an intraocular silicone oil microdroplet after a vitreoretinal operation using disposable instruments, and the surgical technique for its removal. Methods A 59-year-old patient who had been operated on for vitreous opacities using a disposable 27-g vitrectomy kit complained of a small round structure floating in the eye. It appeared a few days after surgery. The bubble was not present at all times and it disappeared for days on end. Clinical examination of the vitreous and retina during these uneventful periods was normal. The bubble reappeared intermittently without a link to any specific movement for some time but was again absent once the patient was examined. The physical properties of the mobile round lesion could be identified as lighter than aqueous humor, as it was described as being in the center of the visual field if the head was tilted forward. Results As the patient was very bothered by this bubble, a 23-g vitrectomy was performed. During deep indentation of the pars plana over 360 degrees, a tiny bubble of silicone oil could be found buried in the peripheral vitreous base, and controlled aspiration under deep indentation was performed. The patient has been without symptoms since the removal of the droplet and made an uneventful clinical recovery. Conclusion Microdroplets of silicone oil may be present in disposable vitreoretinal instruments and stay in the eye after surgery, causing a visual disturbance. The origin of these droplets may be linked to the plastic tubing of the instruments. Zielsetzung Intraokulare Silikonölmikrotropfen wurden nach intravitrealer Injektion von Aliquoten von Anti-VEGF-Medikamenten beobachtet. Wir stellen einen Fall mit einem Silikonölmikrotropfen nach einer mit Einweginstrumenten durchgeführten Vitrektomie vor und diskutieren die Möglichkeiten der Tropfenentfernung. Methoden Ein 59-jähriger Patient, der wegen Glaskörpertrübungen mittels eines Einwegsystems von 27-G-Vitrektomieinstrumenten operiert wurde, beklagte sich postoperativ über eine kleine runde Blase, die im Auge schwamm. Die Blase war nicht immer präsent und verschwand zum Teil während mehrerer Tage. Die klinische Untersuchung während dieser ruhigen Tage war normal. Die physikalischen Eigenschaften der Blase zeigten, dass diese leichter als Wasser war und sich im Zentrum des Gesichtsfelds bei einer Kopfposition gegen unten zeigte. Resultate Da der Patient diese Blase als sehr störend empfand, wurde er mittels einer 23-G-Vitrektomie operiert. Mittels einer tiefen Indentation über 360 ° konnte eine kleine Silikonölblase in der peripheren Glaskörperbasis entdeckt und aspiriert werden. Der Patient war in der Folge ohne klinische Symptome. Schlussfolgerung Mikrotropfen von Silikonöl können durch die Produktion in Einwegvitrektomieinstrumenten vorhanden sein und sich während des chirurgischen Eingriffs an die innere Augenwand heften. Der Ursprung dieser Tröpfchen ist wahrscheinlich mit den Plastikröhrchen dieser Instrumente vergesellschaftet. * Presented in part at the SOG/SSO Meeting Fribourg 30 – 31 August 2018.

  • Hemi‐macular detachment: EnFace optical coherence tomography characteristics and clinical implications

    by Jelena Potic, Ciara Bergin, Clarice Giacuzzo, Alejandra Daruich, Jean‐Antoine Pournaras, Lazaros Konstantinidis, Thomas J. Wolfensberger

  • Disabling Visual Disturbance Caused by Clinically Invisible Vitreous Opacities

    by Bao Khanh Tran, Thomas J. Wolfensberger

    Myodesopsia may be caused by floaters and is a common cause of concern for patients. The prevalence of symptomatic floaters in the general population increases from 24% in adults aged 50 to 59 years to 87% among those aged 80 to 89 years [1]. Floaters are a frequent reason for consulting an ophthalmologist or optometrist, with up to 14 patients a month seeking advice for this reason in a practice [2]. Floaters are usually due to benign age-related degenerative changes of the vitreous body and the occurrence of posterior vitreous detachment, but may also be caused by retinal tears, eventually indicating the presence of a retinal detachment. Patients with floaters report various shapes and sizes, usually moving with eye movements. In most cases, the visual discomfort associated with myodesopsia is limited, but some patients suffer from a significant degradation of visual comfort. On clinical examination, the detection of visually disturbing floaters and their impact on the patientʼs visual perception is sometimes challenging. On the other hand, it is often particularly unsatisfactory for patients with myodesopsia if the clinical examination does not deliver a clear reason for their symptoms, and some patients may develop psychological issues due to the inability to demonstrate why they have these symptoms [3]. In the following, we describe a patient in whom only high-definition OCT revealed a central vitreous floater invisible at indirect ophthalmoscopy.