Olaf Minet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Olaf Minet has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Urszula Zabarylo
Charité Universitaetsmedizin , Berlin , Germany
4 shared publications - Andrey Bogomolov
Samara State Technical University, Samara, Russia
3 shared publications - Elena Feliksberger
Art photonics GmbH, Rudower Chaussee 46, 12489 Berlin, Germany
3 shared publications - Tatiana Sakharova
Art photonics GmbH, Rudower Chaussee 46, 12489 Berlin, Germany
3 shared publications - Valeria Belikova
Laboratory of Multivariate Analysis and Global Modeling, Samara State Technical University, Molodogvardeyskaya 244, 443100 Samara, Russia
3 shared publications C. Dressler
Laser- und Medizin-Technologie GmbH, Berlin, 60-62, Fabeckstrasse, 14195 Berlin, Germany
2 shared publications
Latest Publications
- Open Access
Synergy Effect of Combined Near and Mid-Infrared Fibre Spectroscopy for Diagnostics of Abdominal Cancer
Cancers of the abdominal cavity comprise one of the most prevalent forms of cancers, with the highest contribution from colon and rectal cancers (12% of the human population), followed by stomach cancers (4%). Surgery, as the preferred choice of treatment, includes the selection of adequate resection margins to avoid local recurrences due to minimal residual disease. The presence of functionally vital structures can complicate the choice of resection margins. Spectral analysis of tissue samples in combination with chemometric models constitutes a promising approach for more efficient and precise tumour margin identification. Additionally, this technique provides a real-time tumour identification approach not only for intraoperative application but also during endoscopic diagnosis of tumours in hollow organs. The combination of near-infrared and mid-infrared spectroscopy has advantages compared to individual methods for the clinical implementation of this technique as a diagnostic tool.
Open AccessSynergy Effect of Combined Near and Mid-Infrared Fibre Spectroscopy for Diagnostics of Abdominal Cancer
Cancers of the abdominal cavity comprise one of the most prevalent forms of cancers, with the highest contribution from colon and rectal cancers (12% of the human population), followed by stomach cancers (4%). Surgery, as the preferred choice of treatment, includes the selection of adequate resection margins to avoid local recurrences due to minimal residual disease. The presence of functionally vital structures can complicate the choice of resection margins. Spectral analysis of tissue samples in combination with chemometric models constitutes a promising approach for more efficient and precise tumour margin identification. Additionally, this technique provides a real-time tumour identification approach not only for intraoperative application but also during endoscopic diagnosis of tumours in hollow organs. The combination of near-infrared and mid-infrared spectroscopy has advantages compared to individual methods for the clinical implementation of this technique as a diagnostic tool.
- Open Access
Synergy Effect of Combining Fluorescence and Mid Infrared Fiber Spectroscopy for Kidney Tumor Diagnostics
Matching pairs of tumor and non-tumor kidney tissue samples of four patients were investigated ex vivo using a combination of two methods, attenuated total reflection mid infrared spectroscopy and fluorescence spectroscopy, through respectively prepared and adjusted fiber probes. In order to increase the data information content, the measurements on tissue samples in both methods were performed in the same 31 preselected positions. Multivariate data analysis revealed a synergic effect of combining the two methods for the diagnostics of kidney tumor compared to individual techniques.
Open AccessSynergy Effect of Combining Fluorescence and Mid Infrared Fiber Spectroscopy for Kidney Tumor Diagnostics
Matching pairs of tumor and non-tumor kidney tissue samples of four patients were investigated ex vivo using a combination of two methods, attenuated total reflection mid infrared spectroscopy and fluorescence spectroscopy, through respectively prepared and adjusted fiber probes. In order to increase the data information content, the measurements on tissue samples in both methods were performed in the same 31 preselected positions. Multivariate data analysis revealed a synergic effect of combining the two methods for the diagnostics of kidney tumor compared to individual techniques.
- Open Access
Development and Testing of an LED-Based Near-Infrared Sensor for Human Kidney Tumor Diagnostics
Optical spectroscopy is increasingly used for cancer diagnostics. Tumor detection feasibility in human kidney samples using mid- and near-infrared (NIR) spectroscopy, fluorescence spectroscopy, and Raman spectroscopy has been reported (Artyushenko et al., Spectral fiber sensors for cancer diagnostics in vitro. In Proceedings of the European Conference on Biomedical Optics, Munich, Germany, 21–25 June 2015). In the present work, a simplification of the NIR spectroscopic analysis for cancer diagnostics was studied. The conventional high-resolution NIR spectroscopic method of kidney tumor diagnostics was replaced by a compact optical sensing device constructively represented by a set of four light-emitting diodes (LEDs) at selected wavelengths and one detecting photodiode. Two sensor prototypes were tested using 14 in vitro clinical samples of 7 different patients. Statistical data evaluation using principal component analysis (PCA) and partial least-squares discriminant analysis (PLS-DA) confirmed the general applicability of the LED-based sensing approach to kidney tumor detection. An additional validation of the results was performed by means of sample permutation.
Open AccessDevelopment and Testing of an LED-Based Near-Infrared Sensor for Human Kidney Tumor Diagnostics
Optical spectroscopy is increasingly used for cancer diagnostics. Tumor detection feasibility in human kidney samples using mid- and near-infrared (NIR) spectroscopy, fluorescence spectroscopy, and Raman spectroscopy has been reported (Artyushenko et al., Spectral fiber sensors for cancer diagnostics in vitro. In Proceedings of the European Conference on Biomedical Optics, Munich, Germany, 21–25 June 2015). In the present work, a simplification of the NIR spectroscopic analysis for cancer diagnostics was studied. The conventional high-resolution NIR spectroscopic method of kidney tumor diagnostics was replaced by a compact optical sensing device constructively represented by a set of four light-emitting diodes (LEDs) at selected wavelengths and one detecting photodiode. Two sensor prototypes were tested using 14 in vitro clinical samples of 7 different patients. Statistical data evaluation using principal component analysis (PCA) and partial least-squares discriminant analysis (PLS-DA) confirmed the general applicability of the LED-based sensing approach to kidney tumor detection. An additional validation of the results was performed by means of sample permutation.
- 1 August 2015
- Published by The Journal of Rheumatology in The Journal of Rheumatology
- Vol. 42 (9) , 1595-1602
Comparison of Photo Optical Imaging with Musculoskeletal Ultrasound and Clinical Examination in the Assessment of Inflammatory Activity in Proximal Interphalangeal Joints in Rheumatoid Arthritis and Osteoarthritis
Objective.Lightscan is a novel, rapid, low-cost, easily operated and noninvasive imaging technology used to assess inflammatory activity in proximal interphalangeal (PIP) joints. The results are calculated automatically. To our knowledge, this is the first comparative study of photo optical imaging (POI), with clinical examination (CE), disease activity score at 28 joints (DAS28)-erythrocyte sedimentation rate (ESR), and musculoskeletal ultrasonography (US) in healthy subjects and patients with rheumatoid arthritis (RA) or osteoarthritis (OA).Methods.There were 688 PIP joints of both hands examined in 87 subjects (38 RA, 21 OA, 28 healthy) by Lightscan and compared with CE for clinically swollen and tender joints, DAS28-ESR (only RA), and US.Results.With US as reference, POI had a sensitivity of 74% and a specificity of 93%. In the receiver-operating curve (ROC) analysis, the Lightscan showed a higher sensitivity and specificity [area under the curve (AUC) 0.879] for the distinction of healthy subjects versus patients (OA, RA) than US in greyscale (GSUS; AUC 0.797) and power Doppler (PDUS; AUC 0.67). POI correlated significantly with GSUS (r 0.473, p < 0.01) and PDUS (r 0.486, p < 0.01). The agreement rates between POI and GSUS were up to 79%, between POI and PDUS up to 92%, and between POI and CE up to 66%. POI did not correlate with DAS28-ESR.Conclusion.The Lightscan is a new technology offering sensitive imaging detection of inflammatory changes in subjects with RA and OA with PIP arthritis. POI was more sensitive than CE and correlated significantly to GSUS and PDUS, while presenting a higher sensitivity and specificity for the detection of healthy subjects versus patients (RA, OA) based on the ROC analysis.
- 1 August 2015
- Published by The Journal of Rheumatology in The Journal of Rheumatology
- Vol. 42 (9) , 1595-1602
Comparison of Photo Optical Imaging with Musculoskeletal Ultrasound and Clinical Examination in the Assessment of Inflammatory Activity in Proximal Interphalangeal Joints in Rheumatoid Arthritis and Osteoarthritis
Objective.Lightscan is a novel, rapid, low-cost, easily operated and noninvasive imaging technology used to assess inflammatory activity in proximal interphalangeal (PIP) joints. The results are calculated automatically. To our knowledge, this is the first comparative study of photo optical imaging (POI), with clinical examination (CE), disease activity score at 28 joints (DAS28)-erythrocyte sedimentation rate (ESR), and musculoskeletal ultrasonography (US) in healthy subjects and patients with rheumatoid arthritis (RA) or osteoarthritis (OA).Methods.There were 688 PIP joints of both hands examined in 87 subjects (38 RA, 21 OA, 28 healthy) by Lightscan and compared with CE for clinically swollen and tender joints, DAS28-ESR (only RA), and US.Results.With US as reference, POI had a sensitivity of 74% and a specificity of 93%. In the receiver-operating curve (ROC) analysis, the Lightscan showed a higher sensitivity and specificity [area under the curve (AUC) 0.879] for the distinction of healthy subjects versus patients (OA, RA) than US in greyscale (GSUS; AUC 0.797) and power Doppler (PDUS; AUC 0.67). POI correlated significantly with GSUS (r 0.473, p < 0.01) and PDUS (r 0.486, p < 0.01). The agreement rates between POI and GSUS were up to 79%, between POI and PDUS up to 92%, and between POI and CE up to 66%. POI did not correlate with DAS28-ESR.Conclusion.The Lightscan is a new technology offering sensitive imaging detection of inflammatory changes in subjects with RA and OA with PIP arthritis. POI was more sensitive than CE and correlated significantly to GSUS and PDUS, while presenting a higher sensitivity and specificity for the detection of healthy subjects versus patients (RA, OA) based on the ROC analysis.
- 1 January 2013
- Published by Walter de Gruyter GmbH in Photonics & Lasers in Medicine
- Vol. 2 (4)
Registration of scattered laser images and radiographs of small finger joints
Image processing methods for the registration of scattered light pictures and X-ray radiographs can improve the diagnostic yield of rheumatoid joints as compared to a separate interpretation of radiographs and optical images. The image fusion described uses thin plate spline interpolation techniques. This article also describes the image pre-processing techniques necessary to identify intrinsic landmarks that are a prerequisite for a point-based registration technique.
- 1 January 2013
- Published by Walter de Gruyter GmbH in Photonics & Lasers in Medicine
- Vol. 2 (4)
Registration of scattered laser images and radiographs of small finger joints
Image processing methods for the registration of scattered light pictures and X-ray radiographs can improve the diagnostic yield of rheumatoid joints as compared to a separate interpretation of radiographs and optical images. The image fusion described uses thin plate spline interpolation techniques. This article also describes the image pre-processing techniques necessary to identify intrinsic landmarks that are a prerequisite for a point-based registration technique.
- 31 August 2010
- Published by IOP Publishing in Laser Physics Letters
- Vol. 7 (11) , 817-823
Thermally induced changes of optical and vital parameters in human cancer cells
- 31 August 2010
- Published by IOP Publishing in Laser Physics Letters
- Vol. 7 (11) , 817-823
Thermally induced changes of optical and vital parameters in human cancer cells
- 1 April 2010
- Published by IOP Publishing in Laser Physics Letters
- Vol. 7 (4) , 311-314
Characterization of the respiration of 3T3 cells by laser-induced fluorescence during a cyclic heating process
- 1 April 2010
- Published by IOP Publishing in Laser Physics Letters
- Vol. 7 (4) , 311-314
Characterization of the respiration of 3T3 cells by laser-induced fluorescence during a cyclic heating process
- Open Access
- 16 February 2010
- Published by Wiley in Journal of Biophotonics
- Vol. 3 (3) , 130-137
Diagnosis of rheumatoid arthritis using light: correction of motion artefacts and color visualization of multispectral images
State‐of‐the‐art image‐processing methods offer new possibilities for diagnosing diseases using scattered light. The optical diagnosis of rheumatism is taken as an example to show that the diagnostic sensitivity can be improved using overlapped pseudocolored images of different wavelengths, provided that multispectral images are recorded to compensate for any motion‐related artefacts that occur during examination.
- 16 February 2010
- Published by Wiley in Journal of Biophotonics
- Vol. 3 (3) , 130-137
Open AccessDiagnosis of rheumatoid arthritis using light: correction of motion artefacts and color visualization of multispectral images
State‐of‐the‐art image‐processing methods offer new possibilities for diagnosing diseases using scattered light. The optical diagnosis of rheumatism is taken as an example to show that the diagnostic sensitivity can be improved using overlapped pseudocolored images of different wavelengths, provided that multispectral images are recorded to compensate for any motion‐related artefacts that occur during examination.
- 20 November 2009
- Published by Springer Nature
- p. 89-118
Fluorescence Imaging of Calcium Loading and Mitochondrial Depolarization in Cancer Cells Exposed to Heat Stress
- 20 November 2009
- Published by Springer Nature
- p. 89-118
Fluorescence Imaging of Calcium Loading and Mitochondrial Depolarization in Cancer Cells Exposed to Heat Stress
- 30 November 2008
- Published by Elsevier in Medical Laser Application
- Vol. 23 (4) , 216-225
Deconvolution techniques for experimental optical imaging in medicine
- 30 November 2008
- Published by Elsevier in Medical Laser Application
- Vol. 23 (4) , 216-225
Deconvolution techniques for experimental optical imaging in medicine