D. Elmore
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
D. Elmore has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Aimee A. Norton
Stanford University
2 shared publications - G. L. Card
National Center for Atmospheric Research
2 shared publications - J. Schou
Stanford University
2 shared publications - Juan M. Borrero
Kiepenheuer-Institut für Sonnenphysik Schöneckstr. 6 D-79110 Freiburg Germany
2 shared publications - Steven Tomczyk
High Altitude Observatory, National Center for Atmospheric Research, Boulder, CO 80307, USA
2 shared publications
Latest Publications
- 1 December 2014
- Published by Cambridge University Press (CUP) in Proceedings of the International Astronomical Union
- Vol. 10 (S305) , 102-107
Polarization calibration techniques and scheduling for the Daniel K. Inouye Solar Telescope
The Daniel K. Inouye Solar Telescope (DKIST), formerly Advanced Technology Solar Telescope when it begins operation in 2019 will be by a significant margin Earth's largest solar research telescope. Science priorities dictate an initial suite of instruments that includes four spectro-polarimeters. Accurate polarization calibration of the individual instruments and of the telescope optics shared by those instruments is of critical importance. The telescope and instruments have been examined end-to-end for sources of polarization calibration error, allowable contributions from each of the sources quantified, and techniques identified for calibrating each of the contributors. Efficient use of telescope observing time leads to a requirement of sharing polarization calibrations of common path telescope components among the spectro-polarimeters and for those calibrations to be repeated only as often as dictated by degradation of optical coatings and instrument reconfigurations. As a consequence the polarization calibration of the DKIST is a facility function that requires facility wide techniques.
- 1 December 2014
- Published by Cambridge University Press (CUP) in Proceedings of the International Astronomical Union
- Vol. 10 (S305) , 102-107
Polarization calibration techniques and scheduling for the Daniel K. Inouye Solar Telescope
The Daniel K. Inouye Solar Telescope (DKIST), formerly Advanced Technology Solar Telescope when it begins operation in 2019 will be by a significant margin Earth's largest solar research telescope. Science priorities dictate an initial suite of instruments that includes four spectro-polarimeters. Accurate polarization calibration of the individual instruments and of the telescope optics shared by those instruments is of critical importance. The telescope and instruments have been examined end-to-end for sources of polarization calibration error, allowable contributions from each of the sources quantified, and techniques identified for calibrating each of the contributors. Efficient use of telescope observing time leads to a requirement of sharing polarization calibrations of common path telescope components among the spectro-polarimeters and for those calibrations to be repeated only as often as dictated by degradation of optical coatings and instrument reconfigurations. As a consequence the polarization calibration of the DKIST is a facility function that requires facility wide techniques.
- 30 October 2010
- Published by Springer Nature in Solar Physics
- Vol. 275 (1-2) , 327-355
Polarization Calibration of the Helioseismic and Magnetic Imager (HMI) onboard the Solar Dynamics Observatory (SDO)
- 30 October 2010
- Published by Springer Nature in Solar Physics
- Vol. 275 (1-2) , 327-355
Polarization Calibration of the Helioseismic and Magnetic Imager (HMI) onboard the Solar Dynamics Observatory (SDO)
- Open Access
- 18 June 2010
- Published by Wiley in Astronomische Nachrichten
- Vol. 331 (6) , 655-657
Telescope calibration using polarization calibration data
This article describes the use of the telescope output Stokes vector measured during a polarization calibration to infer the properties of mirrors in the telescope itself. Polarization calibrations performed at the National Solar Observatory Dunn Solar Telescope are used to demonstrate this technique
- 18 June 2010
- Published by Wiley in Astronomische Nachrichten
- Vol. 331 (6) , 655-657
Open AccessTelescope calibration using polarization calibration data
This article describes the use of the telescope output Stokes vector measured during a polarization calibration to infer the properties of mirrors in the telescope itself. Polarization calibrations performed at the National Solar Observatory Dunn Solar Telescope are used to demonstrate this technique
- Open Access
- 1 January 2010
- Published by Springer Nature
- p. 327-355
Polarization Calibration of the Helioseismic and Magnetic Imager (HMI) onboard the Solar Dynamics Observatory (SDO)
As part of the overall ground-based calibration of the Helioseismic and Magnetic Imager (HMI) instrument an extensive set of polarimetric calibrations were performed. This paper describes the polarimetric design of the instrument, the test setup, the polarimetric model, the tests performed, and some results. It is demonstrated that HMI achieves an accuracy of 1% or better on the crosstalks between Q, U, and V and that our model can reproduce the intensities in our calibration sequences to about 0.4%. The amount of depolarization is negligible when the instrument is operated as intended which, combined with the flexibility of the polarimeter design, means that the polarimetric efficiency is excellent.
- 1 January 2010
- Published by Springer Nature
- p. 327-355
Open AccessPolarization Calibration of the Helioseismic and Magnetic Imager (HMI) onboard the Solar Dynamics Observatory (SDO)
As part of the overall ground-based calibration of the Helioseismic and Magnetic Imager (HMI) instrument an extensive set of polarimetric calibrations were performed. This paper describes the polarimetric design of the instrument, the test setup, the polarimetric model, the tests performed, and some results. It is demonstrated that HMI achieves an accuracy of 1% or better on the crosstalks between Q, U, and V and that our model can reproduce the intensities in our calibration sequences to about 0.4%. The amount of depolarization is negligible when the instrument is operated as intended which, combined with the flexibility of the polarimeter design, means that the polarimetric efficiency is excellent.