P. Scott Carney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
P. Scott Carney has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Stephen A. Boppart
University of Illinois Urbana-Champaign
5 shared publications - John C. Schotland
Department of Mathematics and Department of Physics, Yale University, New Haven, CT 06511 USA
3 shared publications Yang Xu
Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, Illinois 61801, USA
3 shared publicationsBradley Deutsch
The Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA
2 shared publicationsEmil Wolf
Department of Physics and Astronomy and the Institute of Optics, University of Rochester, Rochester, New York 14627, USA
2 shared publications- Rohit Bhargava
University of Illinois Urbana-Champaign
2 shared publications
Latest Publications
- 29 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 60 (1) , 1-12
Photo-Enhanced Room Temperature Magnetism and Two-Photon Effects in Manganese-Implanted Gallium Nitride p-i-n Structures
The insertion of manganese into GaN-based p-i-n epitaxial structures allows for a ferromagnetic phase to occur at room temperature that can be photo-enhanced and retained for >8 hours. GaN p-i-n LED structures are implanted with manganese to form a ferromagnetic phase and illuminated with resonant photons across the GaN bandgap. The magnetization after illumination is found to increase by 0.2 μ B /Mn atom. Subsequent illumination below the GaN:Mn bandgap is found to remove the photo-enhancement of magnetism and fully demagnetize the material. The optically-driven process confirms that photon absorption drives hole-media induced ferromagnetic changes to the top layer in GaN:Mn structures. A modified p-i-n structure is designed that situates a two-dimensional hole gas (2DHG) beneath the magnetic layer for improvement of the hole injection effect. The mid-gap state formed by the implanted manganese in GaN:Mn is simulated for two-photon electromagnetic induced transparency that can control the absorption of the top layer and moderate the hole injection. The design of GaN:Mn p-i-n structures is explored for spin-photon mapping of states for long-term storage in memory systems.
- 29 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Quantum Electronics
- Vol. 60 (1) , 1-12
Photo-Enhanced Room Temperature Magnetism and Two-Photon Effects in Manganese-Implanted Gallium Nitride p-i-n Structures
The insertion of manganese into GaN-based p-i-n epitaxial structures allows for a ferromagnetic phase to occur at room temperature that can be photo-enhanced and retained for >8 hours. GaN p-i-n LED structures are implanted with manganese to form a ferromagnetic phase and illuminated with resonant photons across the GaN bandgap. The magnetization after illumination is found to increase by 0.2 μ B /Mn atom. Subsequent illumination below the GaN:Mn bandgap is found to remove the photo-enhancement of magnetism and fully demagnetize the material. The optically-driven process confirms that photon absorption drives hole-media induced ferromagnetic changes to the top layer in GaN:Mn structures. A modified p-i-n structure is designed that situates a two-dimensional hole gas (2DHG) beneath the magnetic layer for improvement of the hole injection effect. The mid-gap state formed by the implanted manganese in GaN:Mn is simulated for two-photon electromagnetic induced transparency that can control the absorption of the top layer and moderate the hole injection. The design of GaN:Mn p-i-n structures is explored for spin-photon mapping of states for long-term storage in memory systems.
- Open Access
- 25 August 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (17) , 4024-4027
Filtering for unwrapping noisy Doppler optical coherence tomography images for extended microscopic fluid velocity measurement range
In this Letter, we report the first application of two phase denoising algorithms to Doppler optical coherence tomography (DOCT) velocity maps. When combined with unwrapping algorithms, significantly extended fluid velocity dynamic range is achieved. Instead of the physical upper bound, the fluid velocity dynamic range is now limited by noise level. We show comparisons between physical simulated ideal velocity maps and the experimental results of both algorithms. We demonstrate unwrapped DOCT velocity maps having a peak velocity nearly 10 times the theoretical measurement range.
- 25 August 2016
- Published by Optica Publishing Group in Optics Letters
- Vol. 41 (17) , 4024-4027
Open AccessFiltering for unwrapping noisy Doppler optical coherence tomography images for extended microscopic fluid velocity measurement range
In this Letter, we report the first application of two phase denoising algorithms to Doppler optical coherence tomography (DOCT) velocity maps. When combined with unwrapping algorithms, significantly extended fluid velocity dynamic range is achieved. Instead of the physical upper bound, the fluid velocity dynamic range is now limited by noise level. We show comparisons between physical simulated ideal velocity maps and the experimental results of both algorithms. We demonstrate unwrapped DOCT velocity maps having a peak velocity nearly 10 times the theoretical measurement range.
- Open Access
- 10 March 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (8) , 2034-2041
Automated interferometric synthetic aperture microscopy and computational adaptive optics for improved optical coherence tomography
In this paper, we introduce an algorithm framework for the automation of interferometric synthetic aperture microscopy (ISAM). Under this framework, common processing steps such as dispersion correction, Fourier domain resampling, and computational adaptive optics aberration correction are carried out as metrics-assisted parameter search problems. We further present the results of this algorithm applied to phantom and biological tissue samples and compare with manually adjusted results. With the automated algorithm, near-optimal ISAM reconstruction can be achieved without manual adjustment. At the same time, the technical barrier for the nonexpert using ISAM imaging is also significantly lowered.
- 10 March 2016
- Published by Optica Publishing Group in Applied Optics
- Vol. 55 (8) , 2034-2041
Open AccessAutomated interferometric synthetic aperture microscopy and computational adaptive optics for improved optical coherence tomography
In this paper, we introduce an algorithm framework for the automation of interferometric synthetic aperture microscopy (ISAM). Under this framework, common processing steps such as dispersion correction, Fourier domain resampling, and computational adaptive optics aberration correction are carried out as metrics-assisted parameter search problems. We further present the results of this algorithm applied to phantom and biological tissue samples and compare with manually adjusted results. With the automated algorithm, near-optimal ISAM reconstruction can be achieved without manual adjustment. At the same time, the technical barrier for the nonexpert using ISAM imaging is also significantly lowered.
- Open Access
- 2 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 22 (3) , 186-196
Computed Optical Interferometric Imaging: Methods, Achievements, and Challenges
Three-dimensional high-resolution optical imaging systems are generally restricted by the tradeoff between resolution and depth-of-field as well as imperfections in the imaging system or sample. Computed optical interferometric imaging is able to overcome these longstanding limitations using methods such as interferometric synthetic aperture microscopy (ISAM) and computational adaptive optics (CAO), which manipulate the complex interferometric data. These techniques correct for limited depth-of-field and optical aberrations without the need for additional hardware. This paper aims to outline these computational methods, making them readily available to the research community. Achievements of the techniques will be highlighted, along with past and present challenges in implementing the techniques. Challenges such as phase instability and determination of the appropriate aberration correction have been largely overcome so that imaging of living tissues using ISAM and CAO is now possible. Computed imaging in optics is becoming a mature technology poised to make a significant impact in medicine and biology.
- 2 November 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Selected Topics in Quantum Electronics
- Vol. 22 (3) , 186-196
Open AccessComputed Optical Interferometric Imaging: Methods, Achievements, and Challenges
Three-dimensional high-resolution optical imaging systems are generally restricted by the tradeoff between resolution and depth-of-field as well as imperfections in the imaging system or sample. Computed optical interferometric imaging is able to overcome these longstanding limitations using methods such as interferometric synthetic aperture microscopy (ISAM) and computational adaptive optics (CAO), which manipulate the complex interferometric data. These techniques correct for limited depth-of-field and optical aberrations without the need for additional hardware. This paper aims to outline these computational methods, making them readily available to the research community. Achievements of the techniques will be highlighted, along with past and present challenges in implementing the techniques. Challenges such as phase instability and determination of the appropriate aberration correction have been largely overcome so that imaging of living tissues using ISAM and CAO is now possible. Computed imaging in optics is becoming a mature technology poised to make a significant impact in medicine and biology.
- 13 May 2015
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 32 (6) , 1126-1131
Compositional prior information in computed infrared spectroscopic imaging
Compositional prior information is used to bridge a gap in the theory between optical coherence tomography (OCT), which provides high-resolution structural images by neglecting spectral variation, and imaging spectroscopy, which provides only spectral information without significant regard to structure. A constraint is proposed in which it is assumed that a sample is composed of distinct materials with known spectra, allowing the structural and spectral composition of the sample to be determined with a number of measurements on the order of . We present a forward model for a sample with heterogeneities along the optical axis and show through simulation that the -species constraint allows unambiguous inversion of Fourier transform interferometric data within the spatial frequency passband of the optical system. We then explore the stability and limitations of this model and extend it to a general 3D heterogeneous sample.- 13 May 2015
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 32 (6) , 1126-1131
Compositional prior information in computed infrared spectroscopic imaging
Compositional prior information is used to bridge a gap in the theory between optical coherence tomography (OCT), which provides high-resolution structural images by neglecting spectral variation, and imaging spectroscopy, which provides only spectral information without significant regard to structure. A constraint is proposed in which it is assumed that a sample is composed of distinct materials with known spectra, allowing the structural and spectral composition of the sample to be determined with a number of measurements on the order of . We present a forward model for a sample with heterogeneities along the optical axis and show through simulation that the -species constraint allows unambiguous inversion of Fourier transform interferometric data within the spatial frequency passband of the optical system. We then explore the stability and limitations of this model and extend it to a general 3D heterogeneous sample.- 3 March 2015
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 17 (33) , 21348-21355
Enhancement and extinction effects in surface-enhanced stimulated Raman spectroscopy
We address the optical physics of surface-enhanced stimulated Raman spectroscopy (SESRS) from the microscopic to macroscopic scales to provide experimental design criteria in colloidal-suspension SESRS.
- 3 March 2015
- Published by Royal Society of Chemistry (RSC) in Physical Chemistry Chemical Physics
- Vol. 17 (33) , 21348-21355
Enhancement and extinction effects in surface-enhanced stimulated Raman spectroscopy
We address the optical physics of surface-enhanced stimulated Raman spectroscopy (SESRS) from the microscopic to macroscopic scales to provide experimental design criteria in colloidal-suspension SESRS.
- Open Access
- 21 October 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (22) , 26621-26634
Synthetic optical holography with nonlinear-phase reference
Synthetic optical holography (SOH) provides efficient encoding of the complex optical signal, both amplitude and phase, for scanning imaging methods. Prior demonstrations have synthesized reference fields with a plane-wave-like linear variation of the phase with position. To record large images without probe-mirror synchronization, a long-travel, closed-loop reference mirror stage has been required. Here we present SOH with a synthetic reference wave with sinusoidal spatial variation of the phase. This allows the use of open loop, limited mirror travel range in SOH, and leads to a novel holographic inversion algorithm. We validate the theory with scans of graphene grain boundaries from a scanning near-field optical microscope, for which SOH has been shown to drastically increase scan speeds [Nat. Commun. 5, 3499 (2014)]
- 21 October 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (22) , 26621-26634
Open AccessSynthetic optical holography with nonlinear-phase reference
Synthetic optical holography (SOH) provides efficient encoding of the complex optical signal, both amplitude and phase, for scanning imaging methods. Prior demonstrations have synthesized reference fields with a plane-wave-like linear variation of the phase with position. To record large images without probe-mirror synchronization, a long-travel, closed-loop reference mirror stage has been required. Here we present SOH with a synthetic reference wave with sinusoidal spatial variation of the phase. This allows the use of open loop, limited mirror travel range in SOH, and leads to a novel holographic inversion algorithm. We validate the theory with scans of graphene grain boundaries from a scanning near-field optical microscope, for which SOH has been shown to drastically increase scan speeds [Nat. Commun. 5, 3499 (2014)]
- Open Access
- 27 June 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (13) , 16606-16618
Multifocal interferometric synthetic aperture microscopy
There is an inherent trade-off between transverse resolution and depth of field (DOF) in optical coherence tomography (OCT) which becomes a limiting factor for certain applications. Multifocal OCT and interferometric synthetic aperture microscopy (ISAM) each provide a distinct solution to the trade-off through modification to the experiment or via post-processing, respectively. In this paper, we have solved the inverse problem of multifocal OCT and present a general algorithm for combining multiple ISAM datasets. Multifocal ISAM (MISAM) uses a regularized combination of the resampled datasets to bring advantages of both multifocal OCT and ISAM to achieve optimal transverse resolution, extended effective DOF and improved signal-to-noise ratio. We present theory, simulation and experimental results.
- 27 June 2014
- Published by Optica Publishing Group in Optics Express
- Vol. 22 (13) , 16606-16618
Open AccessMultifocal interferometric synthetic aperture microscopy
There is an inherent trade-off between transverse resolution and depth of field (DOF) in optical coherence tomography (OCT) which becomes a limiting factor for certain applications. Multifocal OCT and interferometric synthetic aperture microscopy (ISAM) each provide a distinct solution to the trade-off through modification to the experiment or via post-processing, respectively. In this paper, we have solved the inverse problem of multifocal OCT and present a general algorithm for combining multiple ISAM datasets. Multifocal ISAM (MISAM) uses a regularized combination of the resampled datasets to bring advantages of both multifocal OCT and ISAM to achieve optimal transverse resolution, extended effective DOF and improved signal-to-noise ratio. We present theory, simulation and experimental results.
- 12 May 2010
- Published by Optica Publishing Group in Optics Letters
- Vol. 35 (10) , 1683-1685
Cross-validation of interferometric synthetic aperture microscopy and optical coherence tomography
Computationally reconstructed interferometric synthetic aperture microscopy is coregistered with optical coherence tomography (OCT) focal plane data to provide quantitative cross validation with OCT. This is accomplished through a qualitative comparison of images and a quantitative analysis of the width of the point-spread function in simulation and experiment. The width of the ISAM point-spread function is seen to be independent of depth, in contrast to OCT.
- 12 May 2010
- Published by Optica Publishing Group in Optics Letters
- Vol. 35 (10) , 1683-1685
Cross-validation of interferometric synthetic aperture microscopy and optical coherence tomography
Computationally reconstructed interferometric synthetic aperture microscopy is coregistered with optical coherence tomography (OCT) focal plane data to provide quantitative cross validation with OCT. This is accomplished through a qualitative comparison of images and a quantitative analysis of the width of the point-spread function in simulation and experiment. The width of the ISAM point-spread function is seen to be independent of depth, in contrast to OCT.
- 20 April 2010
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 57 (9) , 809-815
Inverse scattering for near-field scanning optical microscopy with broadband illumination
The linear inverse problem for near-field optical microscopy is solved for a broadband scanning modality. Pseudo-inverse formulae are derived and illustrated with numerical simulations.
- 20 April 2010
- Published by Taylor & Francis in Journal of Modern Optics
- Vol. 57 (9) , 809-815
Inverse scattering for near-field scanning optical microscopy with broadband illumination
The linear inverse problem for near-field optical microscopy is solved for a broadband scanning modality. Pseudo-inverse formulae are derived and illustrated with numerical simulations.