  • Intrathoracic Impedance and Ultrasound Lung Comets in Heart Failure Deterioration Monitoring

    by Massimiliano Maines, Domenico Catanzariti, Carlo Angheben, Sergio Valsecchi, Jennifer Comisso, Giuseppe Vergara

    Purpose: Echographic examination of the lung surface may reveal multiple ultrasound lung comets (ULCs) originating from water‐thickened interlobular septa. These images were demonstrated to be useful for noninvasive assessment of interstitial pulmonary edema. Similarly, the correlation between implantable defibrillator‐measured intrathoracic impedance and pulmonary capillary wedge pressure (PCWP) was demonstrated in heart failure (HF) patients. The aims of this analysis were to assess the agreement between defibrillator‐detected impedance decrease and the presence of ULCs, as well as to compare the performance of the impedance‐detection algorithm and the ULCs assessment in predicting HF worsening. Methods and Results: We studied 23 HF patients implanted with a defibrillator capable of intrathoracic impedance measurement and alerting for fluid accumulation diagnosis. At regular follow‐up and at visits for HF decompensation or device alert, clinical status was assessed, chest ultrasound was performed, and PCWP was noninvasively estimated with Doppler echocardiography. During 23 ± 11 months of follow‐up, 45 paired assessments of defibrillator‐measured intrathoracic impedance and ULCs were performed. The number of ULCs resulted significantly correlated to the paired PCWP estimations (r = 0.917, P < 0.001) and to the impedance fluid index (r = 0.669, P < 0.001). During follow‐up, 12 episodes of HF decompensation were reported in 12 patients. The impedance alert detected clinical HF deterioration with 92% sensitivity and 69% positive predictive value. The presence of ≥5 ULCs showed 83% sensitivity and 91% positive predictive value. Conclusions: These data demonstrate the correlation between intrathoracic impedance and the number of ULCs at chest ultrasound, and a good agreement between the defibrillator warning for fluid index and the detection of multiple ULCs. (PACE 2011; 34:968–974)


  • Intrathoracic impedance and pulmonary wedge pressure for the detection of heart failure deterioration

    by Massimiliano Maines, Domenico Catanzariti, Carlo Cirrincione, Sergio Valsecchi, Jennifer Comisso, Giuseppe Vergara

    Aims The aims of this analysis were to assess the agreement between implantable defibrillator (ICD)-measured intrathoracic impedance and pulmonary capillary wedge pressure (PCWP) collected during long-term follow-up, as well as to evaluate whether PCWP measures may improve the performance of the impedance detection algorithm in predicting heart failure (HF) worsening.


  • Intrathoracic and Ventricular Impedances are Associated with Changes in Ventricular Volume in Patients Receiving Defibrillators for CRT

    by Massimiliano Maines, Maurizio Landolina, Maurizio Lunati, Gabriele Lonardi, Alessia Pappone, Alessandro Proclemer, Gabriele Zanotto, Massimo Santini, Annamaria Varbaro, Marco Vimercati, et al.

    Background: Some implantable cardioverter defibrillators (ICD) are able to monitor intrathoracic impedance to detect pulmonary fluid overload. This is achieved by measuring impedance between the ICD case and the right ventricular (RV) lead. We hypothesized that the measured impedance would rise with improvement in left ventricular (LV) volumes during cardiac resynchronization therapy (CRT), and that such impedance changes would be more apparent when measured with an alternative pacing vector. Methods: We analyzed echocardiographic and impedance data from heart failure patients implanted with a CRT–ICD capable of intrathoracic impedance measurement for fluid accumulation diagnosis, and LV pacing impedance recording for lead integrity monitoring. Results: In 127 out of 170 patients that received de novo CRT implantation, the LV end-systolic volume (LVESV) decreased at 6-month follow-up (LVESV at 6 month—LVESV at baseline Conclusions: The changes in ICD-measured impedance seem associated with the LV volume changes induced by CRT. Specifically, the LV-to-RV impedance estimations seem to better correlate with paired changes of ventricular volumes. (PACE 2010; 64–73)


  • Usefulness of intrathoracic fluids accumulation monitoring with an implantable biventricular defibrillator in reducing hospitalizations in patients with heart failure: A case-control study

    by Massimiliano Maines, Domenico Catanzariti, Claudio Cemin, Chiara Vaccarini, Giuseppe Vergara

    The reduction of hospitalizations in patients with heart failure (HF) may have clinical and economical implications. In a case-control study, we compared the number of hospital admissions for congestive HF during the same follow-up period in two homogeneous groups of patients, each consisting of 27 consecutive patients treated with biventricular pacing and back-up defibrillator (B-ICD) in our institution. The first group was implanted with an InSync Sentry®, (Medtronic Inc, Minneapolis, MN, US), a B-ICD device with the OptiVol®feature for monitoring intrathoracic fluid accumulation and equipped with an active acoustic alarm (Group 1); the second group was implanted with an InSync III Marquis™(Medtronic), a B-ICD device with similar features except for the absence of the OptiVol (Group 2). Follow-up visits were performed at 3 month interval or in case of acoustic alarm. The patient clinical characteristics of the two groups were similar. In Group 1, with 359 ± 98 days follow-up, 12 of the 27 patients, experienced 18 OptiVol alarms with only one hospital admission for congestive HF occurring in a patient who ignored the acoustic alarm for 13 days. In Group 2, eight HF hospitalizations occurred in seven patients (p < 0.05). The OptiVol feature is a useful tool for the clinical management of HF patients as it can result in early treatment during the pre-clinic stage of HF decompensation and in a significant reduction of hospital admissions for congestive HF.