Weihua Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Weihua Zhu has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Zhi-Min Zhao
College of Science, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
4 shared publications Chunmei Tang
3 shared publicationsXin Guo
3 shared publicationsChun-Mei Tang
College of Science, Hohai University, Jiangsu, Nanjing 210098, PR China
2 shared publicationsFeng Zhu
CCCC-Fhdi Engineering Co., Ltd, Guangdong, Guangzhou 510000, PR China
2 shared publications- Hongbing Yao
College of Mechanics and Engineering Science, Hohai University, Nanjing, 211100, China
2 shared publications
Latest Publications
- Open Access
Cavitation Erosion Prevention Using Laser Shock Peening: Development of a Predictive Evaluation System
Marine flow-passing components are susceptible to cavitation erosion (CE), and researchers have worked to find ways to reduce its effects. Laser Shock Peening (LSP), a material strengthening method, has been widely used in aerospace and other cutting-edge fields. In recent years, LSP has been used in cavitation resistance research. However, the current LSP research does not realize a comprehensive predictive assessment of the material’s CE resistance. This paper uses m stresses to develop a comprehensive set of strengthening effect prediction models from LSP to CE using finite element analysis (FEA). Results show that the LSP-1 sample (4 mm spot, 10 J energy) introduced a compressive residual stress value of 37.4 MPa, better than that of 16.6 MPa with the LSP-2 sample (6 mm spot, 10 J energy), which is generally consistent with the experimental findings; the model predicts a 16.35% improvement in the resistance of LSP-1 sample to water jet damage, which is comparable to the experimental result of 14.02%; additionally, interactions between micro-jets do not predominate the cavitation erosion process and the final CE effect of the material is mainly due to the accumulation of jet-material interaction.
Open AccessCavitation Erosion Prevention Using Laser Shock Peening: Development of a Predictive Evaluation System
Marine flow-passing components are susceptible to cavitation erosion (CE), and researchers have worked to find ways to reduce its effects. Laser Shock Peening (LSP), a material strengthening method, has been widely used in aerospace and other cutting-edge fields. In recent years, LSP has been used in cavitation resistance research. However, the current LSP research does not realize a comprehensive predictive assessment of the material’s CE resistance. This paper uses m stresses to develop a comprehensive set of strengthening effect prediction models from LSP to CE using finite element analysis (FEA). Results show that the LSP-1 sample (4 mm spot, 10 J energy) introduced a compressive residual stress value of 37.4 MPa, better than that of 16.6 MPa with the LSP-2 sample (6 mm spot, 10 J energy), which is generally consistent with the experimental findings; the model predicts a 16.35% improvement in the resistance of LSP-1 sample to water jet damage, which is comparable to the experimental result of 14.02%; additionally, interactions between micro-jets do not predominate the cavitation erosion process and the final CE effect of the material is mainly due to the accumulation of jet-material interaction.
- Open Access
Investigation into the Effect of Increasing Target Temperature and the Size of Cavity Confinements on Laser-Induced Plasmas
In this work, the effect of the sample temperature on the magnesium (Mg) and titanium (Ti) plasmas generated by a Q-switched Neodymium-doped Yttrium Aluminum Garnet (Nd:YAG) laser operating at its fundamental wavelength of 1064 nm has been investigated. We observed that increasing the sample temperature significantly enhanced the emission intensities of the plasmas. Comparing the emission peak intensities of the case of 100 °C to the case of 300 °C, we recorded a substantial enhancement of the peak intensities of the latter compared to the former. From these results it can be observed that increasing the sample temperature has a significant effect on the emission intensities of the plasmas. We also studied the plasma dynamics and found that increasing the sample temperature also decreases the air density around the Mg sample surface. The reduction in the air density resulted in a decrease in the radiation process and lowers collision probability. Furthermore, as the plasma expands, the plasma pressure also decreases. In addition, we also employed circular and square cavities to confine the titanium plasma, and investigated the effect of the sizes of the circular and square cavities on the titanium plasma. We observed a general improvement in the emission intensities with both the circular and square cavities and attributed this improvement to the plasma compression effect of the shock waves produced by the plasma within the cavities.
Open AccessInvestigation into the Effect of Increasing Target Temperature and the Size of Cavity Confinements on Laser-Induced Plasmas
In this work, the effect of the sample temperature on the magnesium (Mg) and titanium (Ti) plasmas generated by a Q-switched Neodymium-doped Yttrium Aluminum Garnet (Nd:YAG) laser operating at its fundamental wavelength of 1064 nm has been investigated. We observed that increasing the sample temperature significantly enhanced the emission intensities of the plasmas. Comparing the emission peak intensities of the case of 100 °C to the case of 300 °C, we recorded a substantial enhancement of the peak intensities of the latter compared to the former. From these results it can be observed that increasing the sample temperature has a significant effect on the emission intensities of the plasmas. We also studied the plasma dynamics and found that increasing the sample temperature also decreases the air density around the Mg sample surface. The reduction in the air density resulted in a decrease in the radiation process and lowers collision probability. Furthermore, as the plasma expands, the plasma pressure also decreases. In addition, we also employed circular and square cavities to confine the titanium plasma, and investigated the effect of the sizes of the circular and square cavities on the titanium plasma. We observed a general improvement in the emission intensities with both the circular and square cavities and attributed this improvement to the plasma compression effect of the shock waves produced by the plasma within the cavities.
- 18 September 2018
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 122 (40) , 22838-22848
Strain-Enhanced Li Storage and Diffusion on the Graphyne as the Anode Material in the Li-Ion Battery
- 18 September 2018
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 122 (40) , 22838-22848
Strain-Enhanced Li Storage and Diffusion on the Graphyne as the Anode Material in the Li-Ion Battery
- 1 July 2013
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 30 (7) , 077102
A Density Functional Study of the Gold Cages MAu 16 (M = Si, Ge, and Sn)
- 1 July 2013
- Published by IOP Publishing in Chinese Physics Letters
- Vol. 30 (7) , 077102
A Density Functional Study of the Gold Cages MAu 16 (M = Si, Ge, and Sn)
- 1 November 2012
- Published by Elsevier in Computational and Theoretical Chemistry
- Vol. 999, 225-230
Nonclassical fullerene C22H22 doped with transition metal atoms (ScNi): Density functional calculations
- 1 November 2012
- Published by Elsevier in Computational and Theoretical Chemistry
- Vol. 999, 225-230
Nonclassical fullerene C22H22 doped with transition metal atoms (ScNi): Density functional calculations
- 1 June 2010
- Published by Elsevier in Journal of Molecular Structure: THEOCHEM
- Vol. 950 (1-3) , 36-40
Density functional energetics and frontier orbitals analysis for the derivatives of the nonclassical triplet-pentagon-fusion fullerene C64X (X=Si and Ge)
- 1 June 2010
- Published by Elsevier in Journal of Molecular Structure: THEOCHEM
- Vol. 950 (1-3) , 36-40
Density functional energetics and frontier orbitals analysis for the derivatives of the nonclassical triplet-pentagon-fusion fullerene C64X (X=Si and Ge)
- 1 April 2009
- Vol. 29 (4) , 1004-7
[Study of cholesterol concentration based on serum UV-visible absorption spectrum].
In the present paper, UV-visible absorption spectrum and neural network theory were used for the analysis of cholesterol concentration. Experimental investigation shows that the absorption spectrum has the following characteristics in the wave band of 350-600 nm: (1) There is a stronger absorption peak at 416 nm for the test sample with different cholesterol concentration; (2) There is a shoulder peak between 450 and 500 nm, whose central wavelength is 460 nm; (3) There is a weaker peak at 578 nm; (4) Absorption spectrums shape of different cholesterol concentration is different obviously. The absorption spectrum of serum is the synthesis result of cholesterol and other components (such as sugar), and the information is contained at each wavelength. There is no significant correlation between absorbance and cholesterol content at 416 nm, showing a random relation, so whether cholesterol content is abnormal is not determined by the absorbance peak at 416 nm. Based on the evident correlation between serum absorption spectrum and cholesterol concentration in the wave band of 455-475 nm, a neural network model was built to predict the cholesterol concentration. The correlation coefficient between predicted cholesterol content output A and objectives T reaches 0.968, which can be regarded as better prediction, and it provides a spectra test method of cholesterol concentration.
- 1 April 2009
- Vol. 29 (4) , 1004-7
[Study of cholesterol concentration based on serum UV-visible absorption spectrum].
In the present paper, UV-visible absorption spectrum and neural network theory were used for the analysis of cholesterol concentration. Experimental investigation shows that the absorption spectrum has the following characteristics in the wave band of 350-600 nm: (1) There is a stronger absorption peak at 416 nm for the test sample with different cholesterol concentration; (2) There is a shoulder peak between 450 and 500 nm, whose central wavelength is 460 nm; (3) There is a weaker peak at 578 nm; (4) Absorption spectrums shape of different cholesterol concentration is different obviously. The absorption spectrum of serum is the synthesis result of cholesterol and other components (such as sugar), and the information is contained at each wavelength. There is no significant correlation between absorbance and cholesterol content at 416 nm, showing a random relation, so whether cholesterol content is abnormal is not determined by the absorbance peak at 416 nm. Based on the evident correlation between serum absorption spectrum and cholesterol concentration in the wave band of 455-475 nm, a neural network model was built to predict the cholesterol concentration. The correlation coefficient between predicted cholesterol content output A and objectives T reaches 0.968, which can be regarded as better prediction, and it provides a spectra test method of cholesterol concentration.
- 1 January 2008
- Vol. 28 (1) , 138-40
[Measurement and analysis of absorption spectrum of human blood].
The present paper puts forward a method of disease diagnosis by using the technology of spectrum analysis of human blood serum. The generation mechanism of absorption spectrum is explained and the absorption spectra of the normal blood serum and the sick blood serum are listed from the experiments of absorption spectrometry. Though the value of absorbency of the sick blood serum is almost equal to that of the normal blood serum in the most absorption spectra, there are some differences around 278 nm in the absorption spectrum. The absorbency of the blood serum with hyperglycemia is greater than that of the normal blood serum at 285 nm in the spectrum, and besides, there comes a peak shift of absorption with hyperglycemia. In the absorption spectrum of the blood serum with hypercholesterolemia, there is a clear absorption peak at 414 nm. However there is not any peak at that wavelength in the absorption spectrum of the normal blood serum. Through comparing the characters of the spectrum, we can judge if the blood sample is or not, and this blood analysis is a new method for the diagnosis of disease. Compared with other methods of blood measurements, the method of absorption spectrum analysis of blood serum presented in this paper, is more convenient for measurement, simpler for analysis, and easier to popularize.
- 1 January 2008
- Vol. 28 (1) , 138-40
[Measurement and analysis of absorption spectrum of human blood].
The present paper puts forward a method of disease diagnosis by using the technology of spectrum analysis of human blood serum. The generation mechanism of absorption spectrum is explained and the absorption spectra of the normal blood serum and the sick blood serum are listed from the experiments of absorption spectrometry. Though the value of absorbency of the sick blood serum is almost equal to that of the normal blood serum in the most absorption spectra, there are some differences around 278 nm in the absorption spectrum. The absorbency of the blood serum with hyperglycemia is greater than that of the normal blood serum at 285 nm in the spectrum, and besides, there comes a peak shift of absorption with hyperglycemia. In the absorption spectrum of the blood serum with hypercholesterolemia, there is a clear absorption peak at 414 nm. However there is not any peak at that wavelength in the absorption spectrum of the normal blood serum. Through comparing the characters of the spectrum, we can judge if the blood sample is or not, and this blood analysis is a new method for the diagnosis of disease. Compared with other methods of blood measurements, the method of absorption spectrum analysis of blood serum presented in this paper, is more convenient for measurement, simpler for analysis, and easier to popularize.