Petr Pokorný
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Petr Pokorný has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Michal Novotný
Institute of Physics, Czech Academy of Sciences, Na Slovance 2, 182 21, Prague 8, Czech Republic
11 shared publications - Přemysl Fitl
Department of Physics and Measurements, University of Chemistry and Technology Prague, Technická 5, 166 28 Prague, Czech Republic
7 shared publications Ján Lančok
6 shared publications- Jindrich Musil
University of West Bohemia
4 shared publications - Jan Vlček
Department of Physics and Measurements, University of Chemistry and Technology Prague, Technicka 5, 16628 Prague, Czech Republic
3 shared publications Jindřich Musil
Institute of Physics of the Czech Academy of Sciences Prague Czech Republic
3 shared publications
Latest Publications
- Open Access
- 5 October 2025
- Published by Elsevier in Applied Surface Science
- Vol. 717
Surface stability of CuBr thin films deposited by pulsed laser deposition
- 5 October 2025
- Published by Elsevier in Applied Surface Science
- Vol. 717
Open AccessSurface stability of CuBr thin films deposited by pulsed laser deposition
- Open Access
- 3 December 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (23) , 4297
Surface Enhancement Using Black Coatings for Sensor Applications
The resolution of a quartz crystal microbalance (QCM) is particularly crucial for gas sensor applications where low concentrations are detected. This resolution can be improved by increasing the effective surface of QCM electrodes and, thereby, enhancing their sensitivity. For this purpose, various researchers have investigated the use of micro-structured materials with promising results. Herein, we propose the use of easy-to-manufacture metal blacks that are highly structured even on a nanoscale level and thus provide more bonding sites for gas analytes. Two different black metals with thicknesses of 280 nm, black aluminum (B-Al) and black gold (B-Au), were deposited onto the sensor surface to improve the sensitivity following the Sauerbrey equation. Both layers present a high surface roughness due to their cauliflower morphology structure. A high response (i.e., resonant frequency shift) of these QCM sensors coated with a black metal layer was obtained. Two gaseous analytes, H2O vapor and EtOH vapor, at different concentrations, are tested, and a distinct improvement of sensitivity is observed for the QCM sensors coated with a black metal layer compared to the blank ones, without strong side effects on resonance frequency stability or mechanical quality factor. An approximately 10 times higher sensitivity to EtOH gas is reported for the QCM coated with a black gold layer compared to the blank QCM sensor.
- 3 December 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (23) , 4297
Open AccessSurface Enhancement Using Black Coatings for Sensor Applications
The resolution of a quartz crystal microbalance (QCM) is particularly crucial for gas sensor applications where low concentrations are detected. This resolution can be improved by increasing the effective surface of QCM electrodes and, thereby, enhancing their sensitivity. For this purpose, various researchers have investigated the use of micro-structured materials with promising results. Herein, we propose the use of easy-to-manufacture metal blacks that are highly structured even on a nanoscale level and thus provide more bonding sites for gas analytes. Two different black metals with thicknesses of 280 nm, black aluminum (B-Al) and black gold (B-Au), were deposited onto the sensor surface to improve the sensitivity following the Sauerbrey equation. Both layers present a high surface roughness due to their cauliflower morphology structure. A high response (i.e., resonant frequency shift) of these QCM sensors coated with a black metal layer was obtained. Two gaseous analytes, H2O vapor and EtOH vapor, at different concentrations, are tested, and a distinct improvement of sensitivity is observed for the QCM sensors coated with a black metal layer compared to the blank ones, without strong side effects on resonance frequency stability or mechanical quality factor. An approximately 10 times higher sensitivity to EtOH gas is reported for the QCM coated with a black gold layer compared to the blank QCM sensor.
- 26 April 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (6) , 065902
Apparatus for measurements of thermal and optical stimulated exo-electron emission and luminescence
The purpose of the design, construction and implementation of vacuum apparatus for measuring simultaneously three or more stimulated phenomena in dielectrics and eventually semiconductors is to investigate those phenomena as a function of temperature and wavelength. The test of equipment and its functionality were carried out step by step (apparatus, components and control sample) and associated with the calculation of the main physical parameters. The tests of individual parts of the apparatus clearly confirmed that the design, construction and selected components fulfil or even exceed the required properties. On the basis of the measurement of selected sample, it was shown that even weak signals from the material can be detected from both thermally stimulated luminescence and thermally stimulated exo-electron emission moreover transmission and desorption can be measured. NaCl:Ni (0.2%) was chosen as the test material. The activation energies and frequency factor were calculated using the methods of different authors.
- 26 April 2018
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 29 (6) , 065902
Apparatus for measurements of thermal and optical stimulated exo-electron emission and luminescence
The purpose of the design, construction and implementation of vacuum apparatus for measuring simultaneously three or more stimulated phenomena in dielectrics and eventually semiconductors is to investigate those phenomena as a function of temperature and wavelength. The test of equipment and its functionality were carried out step by step (apparatus, components and control sample) and associated with the calculation of the main physical parameters. The tests of individual parts of the apparatus clearly confirmed that the design, construction and selected components fulfil or even exceed the required properties. On the basis of the measurement of selected sample, it was shown that even weak signals from the material can be detected from both thermally stimulated luminescence and thermally stimulated exo-electron emission moreover transmission and desorption can be measured. NaCl:Ni (0.2%) was chosen as the test material. The activation energies and frequency factor were calculated using the methods of different authors.
- 10 July 2017
- Published by Wiley in Plasma Processes and Polymers
- Vol. 14 (12)
Creation and behavior of radicals and ions in the Acetylene/Argon microwave ECR discharge
Formation and number of molecules, radicals, and ions in ECR acetylene/argon discharge is studied as functions of gas flow rate, supplied power, and partial pressure of acetylene. The spectra obtained by neutral mass spectrometry (NMS) exhibit the presence of atomic hydrogen and H2 molecules. The quantity of acetylene ions is rather high in the range of power up to 350 W, but it drops down with increasing power. At higher powers, the change to C2H+ ion takes place and its quantity grows with increasing power. The dependence of the number of C2+, C2H+, C2H2+ on the electron energy is judged by appearance potential mass spectrometry in the energy range 0–100 eV. The obtained findings are useful for the technology of industrial preparation of DLC thin films.
- 10 July 2017
- Published by Wiley in Plasma Processes and Polymers
- Vol. 14 (12)
Creation and behavior of radicals and ions in the Acetylene/Argon microwave ECR discharge
Formation and number of molecules, radicals, and ions in ECR acetylene/argon discharge is studied as functions of gas flow rate, supplied power, and partial pressure of acetylene. The spectra obtained by neutral mass spectrometry (NMS) exhibit the presence of atomic hydrogen and H2 molecules. The quantity of acetylene ions is rather high in the range of power up to 350 W, but it drops down with increasing power. At higher powers, the change to C2H+ ion takes place and its quantity grows with increasing power. The dependence of the number of C2+, C2H+, C2H2+ on the electron energy is judged by appearance potential mass spectrometry in the energy range 0–100 eV. The obtained findings are useful for the technology of industrial preparation of DLC thin films.
- 17 June 2016
- Published by Wiley in Plasma Processes and Polymers
- Vol. 13 (10) , 970-980
A Detailed Investigation of Radicals and Ions in ECR Methane/Argon Microwave Discharge
In this work, we focus on study of the formation and behavior of molecules, radicals, and ions in ECR discharge in a mixture of argon and methane. Discharge properties are studied at various conditions; total gas flow (0–50 sccm), absorbed microwave power (0–900 W) and the partial pressure of methane (0–1.2 Pa). Neutral mass spectrometry does not reveal the presence of radical CH5 commonly described in literature. Spectra show the presence of atomic hydrogen H and especially H2 molecules. The number of CH4+ and CH3+ species shows that the amount of CH4+ in areas power up to 350 W is high, but with further increase of the power their amount decreases. With the increasing power the CH3+ ions are more intensively generated. The obtained data helps optimize process conditions for the fabrication of diamond and DLC thin films.
- 17 June 2016
- Published by Wiley in Plasma Processes and Polymers
- Vol. 13 (10) , 970-980
A Detailed Investigation of Radicals and Ions in ECR Methane/Argon Microwave Discharge
In this work, we focus on study of the formation and behavior of molecules, radicals, and ions in ECR discharge in a mixture of argon and methane. Discharge properties are studied at various conditions; total gas flow (0–50 sccm), absorbed microwave power (0–900 W) and the partial pressure of methane (0–1.2 Pa). Neutral mass spectrometry does not reveal the presence of radical CH5 commonly described in literature. Spectra show the presence of atomic hydrogen H and especially H2 molecules. The number of CH4+ and CH3+ species shows that the amount of CH4+ in areas power up to 350 W is high, but with further increase of the power their amount decreases. With the increasing power the CH3+ ions are more intensively generated. The obtained data helps optimize process conditions for the fabrication of diamond and DLC thin films.
- 28 December 2014
- Published by Wiley in Plasma Processes and Polymers
- Vol. 12 (5) , 416-421
Contamination of Magnetron Sputtered Metallic Films by Oxygen From Residual Atmosphere in Deposition Chamber
The article reports on the contamination of Ag thin films sputtered from a pure Ag target in Ar and Ne gas by the RF magnetron by gas atoms contained in residual gas atmosphere in the deposition chamber at different values of the base pressure. The amount of O atoms generated at different values of base pressure is compared with the amount of Ag atoms sputtered at different deposition rates of Ag film. This comparison reveals a great problem in the formation of pure metallic films at low deposition rates and high values of the base pressure. No pure Ag films can be deposited at low in deposition chambers evacuated with diffusion or root pumps to the base pressures lower than 1 mPa only.
- 28 December 2014
- Published by Wiley in Plasma Processes and Polymers
- Vol. 12 (5) , 416-421
Contamination of Magnetron Sputtered Metallic Films by Oxygen From Residual Atmosphere in Deposition Chamber
The article reports on the contamination of Ag thin films sputtered from a pure Ag target in Ar and Ne gas by the RF magnetron by gas atoms contained in residual gas atmosphere in the deposition chamber at different values of the base pressure. The amount of O atoms generated at different values of base pressure is compared with the amount of Ag atoms sputtered at different deposition rates of Ag film. This comparison reveals a great problem in the formation of pure metallic films at low deposition rates and high values of the base pressure. No pure Ag films can be deposited at low in deposition chambers evacuated with diffusion or root pumps to the base pressures lower than 1 mPa only.