H. Sittek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
H. Sittek has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
M Reiser
17 shared publicationsM Kessler
7 shared publications- C. Perlet
Klinikum rechts der Isar der TU München
6 shared publications J Görich
Universitätsklinik Bonn-Venusberg
5 shared publicationsM. Reiser
5 shared publicationsI Hasan
4 shared publications
Latest Publications
- 30 May 2005
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 177 (06) , 818-827
Die „EVA”-Studie: Evaluierung der Leistungsfähigkeit diagnostischer Verfahren (Mammographie, Sonographie, MRT) zur sekundären und tertiären Prävention des familiären Mammakarzinoms - Zwischenergebnisse nach der ersten Hälfte der Förderungsperiode
Ziel: Zur systematischen Evaluierung der Leistungsfähigkeit der verschiedenen bildgebenden Verfahren hinsichtlich der Früherkennung des familiären Mammakarzinoms hat die Deutsche Krebshilfe eine Multicenter-Studie ins Leben gerufen („EVA”-Studie), die in Form einer prospektiven klinischen Studie die standardisierte, verfahrensgetrennte und synoptische Analyse von Mammographie (Mx), hochauflösender Sonographie (US) und MRT gewährleistet. Wir berichten über unsere Erfahrungen nach der ersten Hälfte der Förderungsperiode. Material und Methoden: An vier Radiologischen Universitätskliniken (Ulm, München/Großhadern, Münster, Bonn) wurden Frauen aus Hochrisiko-Familien über das Schwerpunktprogramm zum familiären Mamma-und Ovarialkarzinom rekrutiert und in die Studie eingeschlossen. Das Protokoll sieht halbjährlich US und klinische Untersuchung sowie eine jährliche Mx und MRT vor. Die Untersuchungen werden zunächst separat befundet und standardisiert dokumentiert. In einem zweiten Schritt werden jeweils separat Mx und US kombiniert, dann Mx und MRT, US und MRT, schließlich alle drei Verfahren. Die exakte Erfassung und modalitätsgetrennte Zuordnung der identifizierten Läsionen erfolgte in einer spezialisierten Datenbank. Ergebnisse: Bislang sind 748 Screeningrunden bei 613 Frauen (mittleres Alter: 42 Jahre, 21 bis 67) erfolgt. Zwölf Karzinome wurden bislang identifiziert, die sich in 11/12 Fällen im Stadium pTis- bzw. pT1/ N0 befanden; die mittlere Größe der acht invasiven Karzinome betrug 7 mm; 12/12 wurden als M0 kategorisiert. Ein Intervallkarzinom ist nicht aufgetreten. Insgesamt 19 Biopsie-Empfehlungen erbrachten benigne Ergebnisse (Fibroadenome, Adenose, radiäre Narbe, ADH). Die MRT erlaubte die Diagnose von 10/12 Karzinomen; in zwei Fällen wurde die Diagnose über die Mammographie gestellt. Kein Karzinom wurde nur aufgrund des Ultraschalls diagnostiziert. Detektionsraten: Mammographie 5/12 (42 %), US 3/12 (25 %), MRT 10/12 (83 %); PPV: Mammographie 5/17 (29 %), US 3/15 (30 %), MRT: 10/23 (43 %). Schlussfolgerung: Diese Zwischenergebnisse deuten darauf hin, dass mittels einer intensivierten Früherkennung (d. h. unter Einbeziehung speziell der MRT) die Früherkennung des familiären Mammakarzinoms in einem prognostisch günstigen Stadium ermöglicht wird. Purpose: To investigate the respective diagnostic accuracies of the different breast imaging modalities, i. e., mammography (Mx), high-frequency breast ultrasound (US), and dynamic contrast-enhanced breast (MRI) regarding the early diagnosis of familial (hereditary) breast cancer. Materials and Methods: A prospective, non-randomized controlled clinical multi-center trial is performed at 4 academic tertiary care centers in Germany (Ulm, München/Großhadern, Münster and Bonn) for a total period of 4 years, sponsored by the German Cancer Aid. The protocol consists of semiannual clinical visits and breast ultrasound, and annual bilateral two-view Mx, US and MRI. Imaging studies were first analyzed independently, then Mx was read in conjunction with US, followed by Mx combined with MRI, and finally, all three imaging modalities were read in synopsis. We present the concept and first results of this trial. Results: So far, 748 screening rounds are available for analysis in 613 women. A total of 12 breast cancers have been identified, with 11/12 cases in the pTis or pT1/N0 stage. The mean size of detected invasive cancers was 7 mm. A total of 19 benign lesions were biopsied due to false-positive imaging diagnoses. The breast cancer detection rates were: Mx: 5/12 (42 %), US 3/12 (25 %), MRI 10/12 (83 %), and the positive predictive values: Mx 5/17 (29 %), US 3/15 (30 %), and MRI 10/23 (43 %). Conclusion: The preliminary data suggest that early diagnosis of familial breast cancer is feasible by intensified surveillance, in particular with the addition of MRI.
- 30 May 2005
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 177 (06) , 818-827
Die „EVA”-Studie: Evaluierung der Leistungsfähigkeit diagnostischer Verfahren (Mammographie, Sonographie, MRT) zur sekundären und tertiären Prävention des familiären Mammakarzinoms - Zwischenergebnisse nach der ersten Hälfte der Förderungsperiode
Ziel: Zur systematischen Evaluierung der Leistungsfähigkeit der verschiedenen bildgebenden Verfahren hinsichtlich der Früherkennung des familiären Mammakarzinoms hat die Deutsche Krebshilfe eine Multicenter-Studie ins Leben gerufen („EVA”-Studie), die in Form einer prospektiven klinischen Studie die standardisierte, verfahrensgetrennte und synoptische Analyse von Mammographie (Mx), hochauflösender Sonographie (US) und MRT gewährleistet. Wir berichten über unsere Erfahrungen nach der ersten Hälfte der Förderungsperiode. Material und Methoden: An vier Radiologischen Universitätskliniken (Ulm, München/Großhadern, Münster, Bonn) wurden Frauen aus Hochrisiko-Familien über das Schwerpunktprogramm zum familiären Mamma-und Ovarialkarzinom rekrutiert und in die Studie eingeschlossen. Das Protokoll sieht halbjährlich US und klinische Untersuchung sowie eine jährliche Mx und MRT vor. Die Untersuchungen werden zunächst separat befundet und standardisiert dokumentiert. In einem zweiten Schritt werden jeweils separat Mx und US kombiniert, dann Mx und MRT, US und MRT, schließlich alle drei Verfahren. Die exakte Erfassung und modalitätsgetrennte Zuordnung der identifizierten Läsionen erfolgte in einer spezialisierten Datenbank. Ergebnisse: Bislang sind 748 Screeningrunden bei 613 Frauen (mittleres Alter: 42 Jahre, 21 bis 67) erfolgt. Zwölf Karzinome wurden bislang identifiziert, die sich in 11/12 Fällen im Stadium pTis- bzw. pT1/ N0 befanden; die mittlere Größe der acht invasiven Karzinome betrug 7 mm; 12/12 wurden als M0 kategorisiert. Ein Intervallkarzinom ist nicht aufgetreten. Insgesamt 19 Biopsie-Empfehlungen erbrachten benigne Ergebnisse (Fibroadenome, Adenose, radiäre Narbe, ADH). Die MRT erlaubte die Diagnose von 10/12 Karzinomen; in zwei Fällen wurde die Diagnose über die Mammographie gestellt. Kein Karzinom wurde nur aufgrund des Ultraschalls diagnostiziert. Detektionsraten: Mammographie 5/12 (42 %), US 3/12 (25 %), MRT 10/12 (83 %); PPV: Mammographie 5/17 (29 %), US 3/15 (30 %), MRT: 10/23 (43 %). Schlussfolgerung: Diese Zwischenergebnisse deuten darauf hin, dass mittels einer intensivierten Früherkennung (d. h. unter Einbeziehung speziell der MRT) die Früherkennung des familiären Mammakarzinoms in einem prognostisch günstigen Stadium ermöglicht wird. Purpose: To investigate the respective diagnostic accuracies of the different breast imaging modalities, i. e., mammography (Mx), high-frequency breast ultrasound (US), and dynamic contrast-enhanced breast (MRI) regarding the early diagnosis of familial (hereditary) breast cancer. Materials and Methods: A prospective, non-randomized controlled clinical multi-center trial is performed at 4 academic tertiary care centers in Germany (Ulm, München/Großhadern, Münster and Bonn) for a total period of 4 years, sponsored by the German Cancer Aid. The protocol consists of semiannual clinical visits and breast ultrasound, and annual bilateral two-view Mx, US and MRI. Imaging studies were first analyzed independently, then Mx was read in conjunction with US, followed by Mx combined with MRI, and finally, all three imaging modalities were read in synopsis. We present the concept and first results of this trial. Results: So far, 748 screening rounds are available for analysis in 613 women. A total of 12 breast cancers have been identified, with 11/12 cases in the pTis or pT1/N0 stage. The mean size of detected invasive cancers was 7 mm. A total of 19 benign lesions were biopsied due to false-positive imaging diagnoses. The breast cancer detection rates were: Mx: 5/12 (42 %), US 3/12 (25 %), MRI 10/12 (83 %), and the positive predictive values: Mx 5/17 (29 %), US 3/15 (30 %), and MRI 10/23 (43 %). Conclusion: The preliminary data suggest that early diagnosis of familial breast cancer is feasible by intensified surveillance, in particular with the addition of MRI.
- 1 January 2002
- Vol. 42 (1)
[Stereotactic vacuum biopsy in prone and sitting position].
- 19 July 2001
- Vol. 143, 32-5
[Screening lowers breast cancer mortality. Motivate your patients for mammography].
Breast cancer is the most common malignant disease in women under 70, and the most common cause of death in those under 50. Causal prophylaxis is unknown. Only early diagnosis prior to the onset of lymphogenic or hematogenic metastasization improves the prognosis. Since the early nineteen-sixties, large-scale studies have shown that screening mammography can reduce mortality. Furthermore, early diagnosis enables breast-conserving treatment in up to 70% of cases. Disadvantages of screening mammography currently under discussion are the radiation burden, the number of false-positive diagnoses prompting biopsy and incurring costs. In Germany, the cost of screening mammography in women with no relevant history or clinical symptoms is not borne by the state-affiliated health insurance carriers. Currently, ongoing pilot projects are investigating quality-controlled early diagnosis with mammography.
- 19 July 2001
- Vol. 143, 32-5
[Screening lowers breast cancer mortality. Motivate your patients for mammography].
Breast cancer is the most common malignant disease in women under 70, and the most common cause of death in those under 50. Causal prophylaxis is unknown. Only early diagnosis prior to the onset of lymphogenic or hematogenic metastasization improves the prognosis. Since the early nineteen-sixties, large-scale studies have shown that screening mammography can reduce mortality. Furthermore, early diagnosis enables breast-conserving treatment in up to 70% of cases. Disadvantages of screening mammography currently under discussion are the radiation burden, the number of false-positive diagnoses prompting biopsy and incurring costs. In Germany, the cost of screening mammography in women with no relevant history or clinical symptoms is not borne by the state-affiliated health insurance carriers. Currently, ongoing pilot projects are investigating quality-controlled early diagnosis with mammography.
- 1 January 2001
- Vol. 53 (6) , 260-5
[Time needs in evaluating digital thoracic images on the monitor in comparison with alternator].
Evaluation of time efficiency in softcopy reading versus hardcopy reading of digital chest x-rays. 130 normal and pathologic chest x-rays in two plains were analyzed by 4 experienced radiologist at both a digital workstation and the light box. Reading time and switch time between two patient folders were measured as well as the frequency of post-processing at the monitor. Reading time at the workstation slightly exceeded reading time at the light box; differences were not statistically significant. Post-processing (frequency between 2% and 83%) did not significantly prolong reading time. Mean switch time between two patient folders was 4.3 sec at the workstation and 13.7 sec at the light box. As compared to hardcopy reading, softcopy reading of digital chest x-rays does not significantly increase reading time. Switch time between patient folders can be reduced at the workstation by a factor of two to four.
- 1 January 2001
- Vol. 53 (6) , 260-5
[Time needs in evaluating digital thoracic images on the monitor in comparison with alternator].
Evaluation of time efficiency in softcopy reading versus hardcopy reading of digital chest x-rays. 130 normal and pathologic chest x-rays in two plains were analyzed by 4 experienced radiologist at both a digital workstation and the light box. Reading time and switch time between two patient folders were measured as well as the frequency of post-processing at the monitor. Reading time at the workstation slightly exceeded reading time at the light box; differences were not statistically significant. Post-processing (frequency between 2% and 83%) did not significantly prolong reading time. Mean switch time between two patient folders was 4.3 sec at the workstation and 13.7 sec at the light box. As compared to hardcopy reading, softcopy reading of digital chest x-rays does not significantly increase reading time. Switch time between patient folders can be reduced at the workstation by a factor of two to four.
- 1 January 1999
- Vol. 52 (8) , 270-2
[Multiple myeloma metastasizing into the breast: mammography and ultrasonic imaging].
- 1 January 1999
- Vol. 52 (8) , 270-2
[Multiple myeloma metastasizing into the breast: mammography and ultrasonic imaging].
- 1 August 1998
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 19 (04) , 164-167
Vergleich eines High-End-Ultraschallgerätes mit einem Spiral-CT-Scanner beim Screening von Lebermetastasen
To assess prospectively the sensitivity of a high-end ultrasound system in comparison to a spiral computed tomographic scanner in screening for liver metastases. 88 consecutive patients with malignant diseases were examined using gray-scale sonography and contrast enhanced two-phase spiral computed tomography during arterial dominant and portal venous phase. For both methods all focal lesions of the liver were reported. 99 focal lesions of the liver were detected by gray-scale sonography and/or two-phase spiral computed tomography. The sensitivity for gray-scale sonography was 93.9% (93 of 99 lesions) and for two-phase spiral computed tomography (71.7% (71 of 99 lesions), respectively. Screening for liver metastases should be performed by using a diagnostic method with a high sensitivity. Gray-scale sonography with a high-end ultrasound system fulfill' these requirements.
- 1 August 1998
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 19 (04) , 164-167
Vergleich eines High-End-Ultraschallgerätes mit einem Spiral-CT-Scanner beim Screening von Lebermetastasen
To assess prospectively the sensitivity of a high-end ultrasound system in comparison to a spiral computed tomographic scanner in screening for liver metastases. 88 consecutive patients with malignant diseases were examined using gray-scale sonography and contrast enhanced two-phase spiral computed tomography during arterial dominant and portal venous phase. For both methods all focal lesions of the liver were reported. 99 focal lesions of the liver were detected by gray-scale sonography and/or two-phase spiral computed tomography. The sensitivity for gray-scale sonography was 93.9% (93 of 99 lesions) and for two-phase spiral computed tomography (71.7% (71 of 99 lesions), respectively. Screening for liver metastases should be performed by using a diagnostic method with a high sensitivity. Gray-scale sonography with a high-end ultrasound system fulfill' these requirements.
- 23 March 1998
- Vol. 3 (3) , 165-71
A comparison of digital luminescence mammography and conventional film - screen system: preliminary results of clinical evaluation.
The objective of this study was to determine if digital luminescence mammography can be used as a diagnostic tool. We investigated twenty-two patients with mammographically suspicious findings using a conventional film-screen system and a digital phosphor storage plate in order to compare these two techniques. Four radiologists experienced in mammography reviewed each pair of images. Our results indicate that detectability of microcalcifications and solid masses with digital systems is superior to conventional film-screen mammography due to the increased contrast enhancement associated with digital systems. We did, however, find that characterization of morphological details is inferior with the digital system, presumably due to reduced spatial resolution. In addition, we found no statistically significant difference in the differentiation of benign from malignant lesions with both techniques. The accuracy of mammographic diagnosis was investigated in a receiver operating characteristic study and similar values were found with both techniques. Our results indicate that digital mammography will become an acceptable diagnostic tool although improvement, especially in spatial resolution, is desirable.
- 23 March 1998
- Vol. 3 (3) , 165-71
A comparison of digital luminescence mammography and conventional film - screen system: preliminary results of clinical evaluation.
The objective of this study was to determine if digital luminescence mammography can be used as a diagnostic tool. We investigated twenty-two patients with mammographically suspicious findings using a conventional film-screen system and a digital phosphor storage plate in order to compare these two techniques. Four radiologists experienced in mammography reviewed each pair of images. Our results indicate that detectability of microcalcifications and solid masses with digital systems is superior to conventional film-screen mammography due to the increased contrast enhancement associated with digital systems. We did, however, find that characterization of morphological details is inferior with the digital system, presumably due to reduced spatial resolution. In addition, we found no statistically significant difference in the differentiation of benign from malignant lesions with both techniques. The accuracy of mammographic diagnosis was investigated in a receiver operating characteristic study and similar values were found with both techniques. Our results indicate that digital mammography will become an acceptable diagnostic tool although improvement, especially in spatial resolution, is desirable.
- 1 January 1998
- Vol. 51 (7) , 235-42
[Dynamic MR-mammography in invasive lobular breast cancer].
The objective of our study was to test the reliability of dynamic, contrast-enhanced MR-mammography (MR-M) in the detection of invasive lobular carcinoma (ILC) and to test if additional examination with MR-M increases the sensitivity of conventional mammography (Mx) in the detection of ILC. We carried out 1,505 MR-Mammographies in 1,357 patients. Biopsy was indicated in 413 cases. Among the malignancies, 23/214 (10.7%) were ILC. MR-M was performed with a 1.0 T whole body MRI system with a dynamic FLASH-3D sequence. Relative signal enhancement within lesions detected and morphologic pattern of contrast enhancement (mep) were determined. Three types of mep were distinguished: type 1 without contrast enhancement, type 2 with focal contrast enhancement and type 3 with diffuse contrast enhancement of the glandular body. Within MR-M alone, 19/23 (82.6%) of ILC were detected due to a mep type 2. Four ILC were false negative on MR-M (2 cases show mep type 1 or mep type 3). The sensitivity of Mx alone was 86.9% (20/23). When both Mx and MR-M were combined, all 23 ILC were detected. The addition of MR-M to Mx may increase sensitivity to about 100% in the detection of ILC. Unsuspicuous MR-M (mep type 1) or diffuse uptake of contrast media (mep type 3) does not rule out malignancy in the presence of suspicious findings at Mx.
- 1 January 1998
- Vol. 51 (7) , 235-42
[Dynamic MR-mammography in invasive lobular breast cancer].
The objective of our study was to test the reliability of dynamic, contrast-enhanced MR-mammography (MR-M) in the detection of invasive lobular carcinoma (ILC) and to test if additional examination with MR-M increases the sensitivity of conventional mammography (Mx) in the detection of ILC. We carried out 1,505 MR-Mammographies in 1,357 patients. Biopsy was indicated in 413 cases. Among the malignancies, 23/214 (10.7%) were ILC. MR-M was performed with a 1.0 T whole body MRI system with a dynamic FLASH-3D sequence. Relative signal enhancement within lesions detected and morphologic pattern of contrast enhancement (mep) were determined. Three types of mep were distinguished: type 1 without contrast enhancement, type 2 with focal contrast enhancement and type 3 with diffuse contrast enhancement of the glandular body. Within MR-M alone, 19/23 (82.6%) of ILC were detected due to a mep type 2. Four ILC were false negative on MR-M (2 cases show mep type 1 or mep type 3). The sensitivity of Mx alone was 86.9% (20/23). When both Mx and MR-M were combined, all 23 ILC were detected. The addition of MR-M to Mx may increase sensitivity to about 100% in the detection of ILC. Unsuspicuous MR-M (mep type 1) or diffuse uptake of contrast media (mep type 3) does not rule out malignancy in the presence of suspicious findings at Mx.
- 1 January 1998
- Vol. 51 (10) , 379-84
[Preoperative marking of non-palpable mammary lesions on the magnetic resonance image using a body coil].
To evaluate the efficacy of a MRI localization procedure using a non-dedicated body coil in lesions only visible in MRI. In 18 patients, we performed a contrast enhanced (i.v. 0.2 mmol Gd-DTPA/kg b.w.) breast MRI on a 1.0 Tesla system (Magnetom Impact, Siemens, Erlangen, Germany) using a body coil and a GRE 3D sequence. In prone position, the patients were placed in a customized positioning device offering lateral access to the breast. The localizations were done with a MRI-compatible wire (n = 21). In addition, all patients underwent the same imaging protocol using a dedicated breast coil (without localization). For both MRI modalities, the signal intensities of the lesion, the normal breast tissue, and the background noise were measured. The lesion-to-fat contrast (LFC), the lesion-to-fat contrast (LFC), the lesion-to-breast tissue contrast (LBC) and the percentage of signal change pre and post contrast administration were calculated and compared. The localisation results were correlated to pathologic findings. There was no difference in lesion detection (lesion size: 0.5 to 1.2 cm) between the body coil and the dedicated breast coil. Regarding the LFC and LBC, the body coil was superior to the dedicated breast coil (no statistical significance). However, the background noise was higher using the body coil. In all cases the localisation was successful. In our preliminary experience, detection of breast lesions and wire-localization of the lesion by MRI is efficient and reliable using a non-dedicated body coil.
- 1 January 1998
- Vol. 51 (10) , 379-84
[Preoperative marking of non-palpable mammary lesions on the magnetic resonance image using a body coil].
To evaluate the efficacy of a MRI localization procedure using a non-dedicated body coil in lesions only visible in MRI. In 18 patients, we performed a contrast enhanced (i.v. 0.2 mmol Gd-DTPA/kg b.w.) breast MRI on a 1.0 Tesla system (Magnetom Impact, Siemens, Erlangen, Germany) using a body coil and a GRE 3D sequence. In prone position, the patients were placed in a customized positioning device offering lateral access to the breast. The localizations were done with a MRI-compatible wire (n = 21). In addition, all patients underwent the same imaging protocol using a dedicated breast coil (without localization). For both MRI modalities, the signal intensities of the lesion, the normal breast tissue, and the background noise were measured. The lesion-to-fat contrast (LFC), the lesion-to-fat contrast (LFC), the lesion-to-breast tissue contrast (LBC) and the percentage of signal change pre and post contrast administration were calculated and compared. The localisation results were correlated to pathologic findings. There was no difference in lesion detection (lesion size: 0.5 to 1.2 cm) between the body coil and the dedicated breast coil. Regarding the LFC and LBC, the body coil was superior to the dedicated breast coil (no statistical significance). However, the background noise was higher using the body coil. In all cases the localisation was successful. In our preliminary experience, detection of breast lesions and wire-localization of the lesion by MRI is efficient and reliable using a non-dedicated body coil.
- 1 November 1997
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 167 (11) , 521-526
Dreidimensionale Dicken- und Volumenbestimmung des Kniegelenkknorpels in der MRT: Validierung am anatomischen Präparat mittels CT-Arthrographie
In the present study we intended to validate knee joint cartilage volume and thickness measurements with MRI. Ten fresh cadaver knees (age 29 to 64 yrs.) were sagittally imaged, using a fat-suppressed FLASH-3D sequence with a resolution of 2 x 0.31 x 0.31 mm3. Then, a contrast agent was injected and the specimens submitted to CT arthrography. From both modalities the patellar, femoral, and tibial cartilages were segmented semiautomatically and reconstructed three-dimensionally. The cartilage thickness was determined independently of the sectional plane, based on a "minimal distance algorithm". The volumes and the regional distribution patterns yielded a very high degree of similarity on direct comparison of both imaging modalities. The average volume error between MRI and CT was 3.8% (+/- 3.0%), the correlation 0.998, the slope of the regression line 1.04 and the gamma-intercept -80 mm3. The analysis yielded no significant differences between the two methods (Wilcoxon signed rank test, 5% level) in the patella, femur, medial, and lateral tibia. The results suggest that, based on a fat-suppressed FLASH sequence with high resolution and three-dimensional concepts of digital image analysis, the cartilage volume and thickness can be analysed non-invasively and with high accuracy by MRI.
- 1 November 1997
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 167 (11) , 521-526
Dreidimensionale Dicken- und Volumenbestimmung des Kniegelenkknorpels in der MRT: Validierung am anatomischen Präparat mittels CT-Arthrographie
In the present study we intended to validate knee joint cartilage volume and thickness measurements with MRI. Ten fresh cadaver knees (age 29 to 64 yrs.) were sagittally imaged, using a fat-suppressed FLASH-3D sequence with a resolution of 2 x 0.31 x 0.31 mm3. Then, a contrast agent was injected and the specimens submitted to CT arthrography. From both modalities the patellar, femoral, and tibial cartilages were segmented semiautomatically and reconstructed three-dimensionally. The cartilage thickness was determined independently of the sectional plane, based on a "minimal distance algorithm". The volumes and the regional distribution patterns yielded a very high degree of similarity on direct comparison of both imaging modalities. The average volume error between MRI and CT was 3.8% (+/- 3.0%), the correlation 0.998, the slope of the regression line 1.04 and the gamma-intercept -80 mm3. The analysis yielded no significant differences between the two methods (Wilcoxon signed rank test, 5% level) in the patella, femur, medial, and lateral tibia. The results suggest that, based on a fat-suppressed FLASH sequence with high resolution and three-dimensional concepts of digital image analysis, the cartilage volume and thickness can be analysed non-invasively and with high accuracy by MRI.