Peter Hunold
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Peter Hunold has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Jorg Barkhausen
Universitätsklinikum Schleswig-Holstein, Campus Lübeck, Klinik für Radiologie und Nuklearmedizin, Lübeck
27 shared publications - P. Bischoff
Klinik für Radiologie und Nuklearmedizin, Universitätsklinikum Schleswig-Holstein, Campus Lübeck
9 shared publications Fm Vogt
7 shared publicationsRl Duschka
5 shared publicationsA Frydrychowicz
UKSH, Klinik für Radiologie und Nuklearmedizin, Lübeck
4 shared publicationsA Kovács
4 shared publications
Latest Publications
- 23 March 2017
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 189 (S 01) , S1-S124
Vergleich hämodynamischer Parameter von Probanden und Patienten mit pulmonaler Hypertonie mittels 4D- und 2D-Fluss MRT
Zielsetzung: Die nicht-invasive Diagnostik der pulmonalen Hypertonie (PH) mit 2D- und 4D-Fluss MRT rückt zunehmend in den klinischen Fokus. Ziel der Studie war es, beide Techniken zu vergleichen und an bereits in 2D-etablierten Parametern an Patienten mit PH und gesunden Probanden zu testen. Material und Methodik: 11 Patienten mit PH (4 weibl., Alter: 63 ± 15 Jahre), 15 alterskorrelierte (9w, 56 ± 11J.) und 20 junge Probanden (13w, 23 ± 2J.) wurden an 3T (Philips Ingenia) mit 2D- und 4D-Phasenkontrast-Sequenzen untersucht. Im Truncus pulmonalis (TP) wurden mit GTFlow (GyroTools, CH) folgende Parameter ausgewertet: Schlagvolumen (SV [ml/s]), die Maxima der Geschwindigkeit (Vmax [cm/s]) und des Flusses (Qmax [ml/s]) und die Zeit zum jeweiligen Maximum (tVmax, tQmax, [ms]). Strain [%] wurde als Variabilität der max. und min. Fläche des Gefäßquerschnitts (Amin, Amax, [mm2]) berechnet. In 4D wurden Blutflussmuster visualisiert. Die Statistik umfasste t-Test und Bland-Altman-Analyse. Ergebnisse: Die 4D-Fluss MRT zeigte gute Übereinstimmung mit den in 2D in der Studienpopulation gemessenen Werten mit einer Tendenz zu höheren Werten, exemplarisch des SV (98,6 ± 20,8 vs. 91,9 ± 18,7; p =< 0,001) und tQmax (143,4 ± 33,9 vs. 132,5 ± 30; p =< 0,001). Zur Identifizierung eines PH erreichten Amin, Amax und Strain in 2D und 4D statistisch signifikante Unterschiede zwischen Patienten und alterskorrelierten Probanden (jeweils p < 0,05). Dabei zeigte sich eine Erhöhung der Mittelwerte bei Patienten von Amin um 92,8%/71,6% (2D/4D), Amax um 62,2%/57,9% (2D/4D) und eine Verminderung des Strain um 48,3%/27,9% (2D/4D) gegenüber Probanden. Ein für PH indikativer Vortex im TP konnte bei 9 von 11 Patienten und 2 Probanden nachgewiesen werden (Spezifität/Sensitivität von 95,7%/81,8% für die Detektion einer PH). Schlussfolgerungen: Die Studie belegt die verlässliche Messung diagnoserelevanter Parameter und die mögliche Unterscheidung von Patienten und Probanden mit der 4D-Fluss MRT. Es gelang Trends verschiedener Parameter für die Diagnose der PH für zukünftige Studien aufzuzeigen.
- 23 March 2017
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 189 (S 01) , S1-S124
Vergleich hämodynamischer Parameter von Probanden und Patienten mit pulmonaler Hypertonie mittels 4D- und 2D-Fluss MRT
Zielsetzung: Die nicht-invasive Diagnostik der pulmonalen Hypertonie (PH) mit 2D- und 4D-Fluss MRT rückt zunehmend in den klinischen Fokus. Ziel der Studie war es, beide Techniken zu vergleichen und an bereits in 2D-etablierten Parametern an Patienten mit PH und gesunden Probanden zu testen. Material und Methodik: 11 Patienten mit PH (4 weibl., Alter: 63 ± 15 Jahre), 15 alterskorrelierte (9w, 56 ± 11J.) und 20 junge Probanden (13w, 23 ± 2J.) wurden an 3T (Philips Ingenia) mit 2D- und 4D-Phasenkontrast-Sequenzen untersucht. Im Truncus pulmonalis (TP) wurden mit GTFlow (GyroTools, CH) folgende Parameter ausgewertet: Schlagvolumen (SV [ml/s]), die Maxima der Geschwindigkeit (Vmax [cm/s]) und des Flusses (Qmax [ml/s]) und die Zeit zum jeweiligen Maximum (tVmax, tQmax, [ms]). Strain [%] wurde als Variabilität der max. und min. Fläche des Gefäßquerschnitts (Amin, Amax, [mm2]) berechnet. In 4D wurden Blutflussmuster visualisiert. Die Statistik umfasste t-Test und Bland-Altman-Analyse. Ergebnisse: Die 4D-Fluss MRT zeigte gute Übereinstimmung mit den in 2D in der Studienpopulation gemessenen Werten mit einer Tendenz zu höheren Werten, exemplarisch des SV (98,6 ± 20,8 vs. 91,9 ± 18,7; p =< 0,001) und tQmax (143,4 ± 33,9 vs. 132,5 ± 30; p =< 0,001). Zur Identifizierung eines PH erreichten Amin, Amax und Strain in 2D und 4D statistisch signifikante Unterschiede zwischen Patienten und alterskorrelierten Probanden (jeweils p < 0,05). Dabei zeigte sich eine Erhöhung der Mittelwerte bei Patienten von Amin um 92,8%/71,6% (2D/4D), Amax um 62,2%/57,9% (2D/4D) und eine Verminderung des Strain um 48,3%/27,9% (2D/4D) gegenüber Probanden. Ein für PH indikativer Vortex im TP konnte bei 9 von 11 Patienten und 2 Probanden nachgewiesen werden (Spezifität/Sensitivität von 95,7%/81,8% für die Detektion einer PH). Schlussfolgerungen: Die Studie belegt die verlässliche Messung diagnoserelevanter Parameter und die mögliche Unterscheidung von Patienten und Probanden mit der 4D-Fluss MRT. Es gelang Trends verschiedener Parameter für die Diagnose der PH für zukünftige Studien aufzuzeigen.
- 29 March 2016
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 188 (S 01) , FFF303_1
Herzdiagnostik-Quiz (mit RSNA Diagnosis Live™)
Es steht kein Abstracttext zur Verfügung.
- 29 March 2016
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 188 (S 01) , FFF303_1
Herzdiagnostik-Quiz (mit RSNA Diagnosis Live™)
Es steht kein Abstracttext zur Verfügung.
- 22 April 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (S 01) , VO302_4
4D Fluss-MRT zur Analyse der aortalen Flusscharakteristika bei Patienten mit Sinusprothese
Zielsetzung: Es war das Ziel, Flusscharakteristika von Aortenprothesen mit physiologisch gestalteten Sinus („Sinusprothese“, Uni-Graft W SINUS, Braun) mittels 4D Fluss-MRT zu analysieren. Material und Methodik: In die Studie wurden 21 Personen (13 Sinusprothesen [SP, 1w, 55 ± 14J.], 4 suprabulbäre Aszendensersätze [AE, 2w, 57 ± 14J.], 4 Probanden [Prob, 3w, 62 ± 7J.]) nach schriftlichem Einverständnis eingeschlossen. Die Untersuchungen wurden an 3T (Philips Achieva) mit einer 20-Kanal Oberflächenspule und einer 3D drei-direktionalen Phasenkontrast-Sequenz durchgeführt. Typische Scanparameter waren Venc = 180 cm/s, Ortsauflösung 2,6 mm3, interpoliert auf 2 mm3, retrospektive EKG-Triggerung und adaptives Atemgating. Flusscharakteristika (Vortices in den Sinus mit Grading [0 – 3]; sekundäre Flussmuster [Vortices, sekundäre Helices] in 4 Segmenten der Aorta; Schlagvolumina) wurden mit GTFlow (v2.1.4, GyroTools) auf Basis farbkodierter Particle Traces und Streamlines analysiert. Die Aortenbogenform wurde als rund, gotisch oder kubisch klassifiziert. Ergebnisse: Sämtliche Teilnehmer zeigten Vortices in den Sinus. Bei 4/13 SP und 1/4 Prob zeigte je 1 Sinus, bei 1/4 AE 2 Sinus keinen Vortex. Die Vortices waren bei den AE ausgeprägter (1,6) als bei SP oder Prob (1,2 bzw. 1,3). Sowohl SP als auch AE zeigten signifikant mehr sekundäre aortale Flussmuster (3,3 bzw. 3,8 je Patient) als die Probanden (je 1,0; p < 0,05). Letztere wiesen eine runde Aortenbogengeometrie auf, während bei AE kubische (3/4) und bei SP kubische (6/13) und gotische (4/13) Formen dominierten. Die Schlagvolumina differierten im Vergleich zu den Probanden nicht signifikant; SP=92±21ml, AE=67±16ml, Prob=73±15ml. Schlussfolgerungen: In den Sinus der SP sind nahe-physiologische Flusscharakteristika abgrenzbar. Die hohe Zahl sekundärer aortaler Flussmuster ist, wie auch bei suprabulbärem Aszendensersatz, am ehesten auf die veränderte Geometrie an der Anastomose zurückzuführen und könnte möglicherweise durch Verwendung anatomisch gebogener Aortenprothesen reduziert werden. E-Mail: [email protected]
- 22 April 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (S 01) , VO302_4
4D Fluss-MRT zur Analyse der aortalen Flusscharakteristika bei Patienten mit Sinusprothese
Zielsetzung: Es war das Ziel, Flusscharakteristika von Aortenprothesen mit physiologisch gestalteten Sinus („Sinusprothese“, Uni-Graft W SINUS, Braun) mittels 4D Fluss-MRT zu analysieren. Material und Methodik: In die Studie wurden 21 Personen (13 Sinusprothesen [SP, 1w, 55 ± 14J.], 4 suprabulbäre Aszendensersätze [AE, 2w, 57 ± 14J.], 4 Probanden [Prob, 3w, 62 ± 7J.]) nach schriftlichem Einverständnis eingeschlossen. Die Untersuchungen wurden an 3T (Philips Achieva) mit einer 20-Kanal Oberflächenspule und einer 3D drei-direktionalen Phasenkontrast-Sequenz durchgeführt. Typische Scanparameter waren Venc = 180 cm/s, Ortsauflösung 2,6 mm3, interpoliert auf 2 mm3, retrospektive EKG-Triggerung und adaptives Atemgating. Flusscharakteristika (Vortices in den Sinus mit Grading [0 – 3]; sekundäre Flussmuster [Vortices, sekundäre Helices] in 4 Segmenten der Aorta; Schlagvolumina) wurden mit GTFlow (v2.1.4, GyroTools) auf Basis farbkodierter Particle Traces und Streamlines analysiert. Die Aortenbogenform wurde als rund, gotisch oder kubisch klassifiziert. Ergebnisse: Sämtliche Teilnehmer zeigten Vortices in den Sinus. Bei 4/13 SP und 1/4 Prob zeigte je 1 Sinus, bei 1/4 AE 2 Sinus keinen Vortex. Die Vortices waren bei den AE ausgeprägter (1,6) als bei SP oder Prob (1,2 bzw. 1,3). Sowohl SP als auch AE zeigten signifikant mehr sekundäre aortale Flussmuster (3,3 bzw. 3,8 je Patient) als die Probanden (je 1,0; p < 0,05). Letztere wiesen eine runde Aortenbogengeometrie auf, während bei AE kubische (3/4) und bei SP kubische (6/13) und gotische (4/13) Formen dominierten. Die Schlagvolumina differierten im Vergleich zu den Probanden nicht signifikant; SP=92±21ml, AE=67±16ml, Prob=73±15ml. Schlussfolgerungen: In den Sinus der SP sind nahe-physiologische Flusscharakteristika abgrenzbar. Die hohe Zahl sekundärer aortaler Flussmuster ist, wie auch bei suprabulbärem Aszendensersatz, am ehesten auf die veränderte Geometrie an der Anastomose zurückzuführen und könnte möglicherweise durch Verwendung anatomisch gebogener Aortenprothesen reduziert werden. E-Mail: [email protected]
- 22 April 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (S 01) , VO302_3
Validierung der ktPCA-beschleunigten 4D Fluss-MRT in einem Modell der Aortenisthmusstenose
Zielsetzung: Die 4D-Fluss MRT ist als Verfahren durch komplexe hämodynamische Analysemöglichkeiten vielversprechend, aufgrund langer Messzeiten jedoch für einen Einsatz in der Routine nur bedingt geeignet. Ziel der Studie war es daher, verschiedene ktPCA- (kt-Beschleunigung mit Principal Component Analysis) Beschleunigungsfaktoren in einem Nachlast-kontrollierten Modell der Aortenisthmusstenose zu validieren. Material und Methodik: Ein Nachlast-kontrolliertes Aortenmodell auf Basis einer elastischen Kunststoff-Aorta (Elastrat, Lausanne) wurde mittels MR-kompatibler Pumpe und Gadolinum-versetzter Blutersatzflüssigkeit (Glycerol, aqua dest.) entwickelt. 3 verschiedene Beschleunigungsfaktoren (r = 2, r = 4, r = 8) wurden im Vergleich zu nicht-beschleunigten (r = 1) 4D Fluss-MRT an einem 3T Scanner getestet. Es kam eine prospektiv EKG-getriggerte 3-dimensionale, 3-direktional flusskodierte Phasenkontrastsequenz an 3T zur Anwendung. Ausgewertet wurden antegrades Flussvolumen, Schlagvolumen und maximale Flussgeschwindigkeiten an jeweils 7 Lokalisationen mittels GTFlow (v2.1.4, GyroTools). Die Visualisierung erfolgte mittels farbkodierter Particle Traces und Streamlines und wurde auf Vorhandensein von Helices und Vortices getestet. Ergebnisse: Das Schlagvolumen bei r = 1 von 54,2 ± 7,4 ml, Maximalgeschwindigkeit 104,9 ± 40,5 cm/s sowie antegrader Fluss von 86,7 ± 60,9 ml unterschieden sich nicht signifikant von den Werten bei den Beschleunigungsfaktoren r = 2, r = 4 und r = 8. Nur das Schlagvolumen bei r = 4 zeigte signifikant geringere Werte. Die visuelle Bewertung der qualitativen Flusscharakteristika wies keine Unterschiede auf. Schlussfolgerungen: Die ktPCA-beschleunigte 4D Fluss-MRT ist ein vielverpsrechender Ansatz. Eine Fehlercharakterisierung im Vergleich zu statischen Phantommessungen steht ebenso wie die nicht-invasive Druckdifferenzquantifizierung aus. Letztere ist insbesondere für die klinische Bewertung der Isthmusstenose von hohem Interesse. Bevor die Messungen am Patienten durchgeführt werden sind in-vivo Studien an Probanden geplant. E-Mail: [email protected]
- 22 April 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (S 01) , VO302_3
Validierung der ktPCA-beschleunigten 4D Fluss-MRT in einem Modell der Aortenisthmusstenose
Zielsetzung: Die 4D-Fluss MRT ist als Verfahren durch komplexe hämodynamische Analysemöglichkeiten vielversprechend, aufgrund langer Messzeiten jedoch für einen Einsatz in der Routine nur bedingt geeignet. Ziel der Studie war es daher, verschiedene ktPCA- (kt-Beschleunigung mit Principal Component Analysis) Beschleunigungsfaktoren in einem Nachlast-kontrollierten Modell der Aortenisthmusstenose zu validieren. Material und Methodik: Ein Nachlast-kontrolliertes Aortenmodell auf Basis einer elastischen Kunststoff-Aorta (Elastrat, Lausanne) wurde mittels MR-kompatibler Pumpe und Gadolinum-versetzter Blutersatzflüssigkeit (Glycerol, aqua dest.) entwickelt. 3 verschiedene Beschleunigungsfaktoren (r = 2, r = 4, r = 8) wurden im Vergleich zu nicht-beschleunigten (r = 1) 4D Fluss-MRT an einem 3T Scanner getestet. Es kam eine prospektiv EKG-getriggerte 3-dimensionale, 3-direktional flusskodierte Phasenkontrastsequenz an 3T zur Anwendung. Ausgewertet wurden antegrades Flussvolumen, Schlagvolumen und maximale Flussgeschwindigkeiten an jeweils 7 Lokalisationen mittels GTFlow (v2.1.4, GyroTools). Die Visualisierung erfolgte mittels farbkodierter Particle Traces und Streamlines und wurde auf Vorhandensein von Helices und Vortices getestet. Ergebnisse: Das Schlagvolumen bei r = 1 von 54,2 ± 7,4 ml, Maximalgeschwindigkeit 104,9 ± 40,5 cm/s sowie antegrader Fluss von 86,7 ± 60,9 ml unterschieden sich nicht signifikant von den Werten bei den Beschleunigungsfaktoren r = 2, r = 4 und r = 8. Nur das Schlagvolumen bei r = 4 zeigte signifikant geringere Werte. Die visuelle Bewertung der qualitativen Flusscharakteristika wies keine Unterschiede auf. Schlussfolgerungen: Die ktPCA-beschleunigte 4D Fluss-MRT ist ein vielverpsrechender Ansatz. Eine Fehlercharakterisierung im Vergleich zu statischen Phantommessungen steht ebenso wie die nicht-invasive Druckdifferenzquantifizierung aus. Letztere ist insbesondere für die klinische Bewertung der Isthmusstenose von hohem Interesse. Bevor die Messungen am Patienten durchgeführt werden sind in-vivo Studien an Probanden geplant. E-Mail: [email protected]
- 22 April 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (S 01) , RK_VO211_3
Häufigkeit eines myokardialen Late Gadolinium Enhancements in Abhängigkeit vom Ausmaß der Koronarverkalkungen in einer asymptomatischen Screening-Population
Zielsetzung: Ziel der vorliegenden Studie war es, den Zusammenhang zwischen der Häufigkeit eines myokardialen Late Gadolinium Enhancements (LGE) und dem Ausmaß von Koronarverkalkungen in einer asymptomatischen Screening-Population zu untersuchen. Material und Methodik: 250 asymptomatische Personen (mittleres Alter 64 ± 7 Jahre) wurden aus dem Kollektiv einer großen Populations-basierten Screening Studie (Heinz Nixdorf Recall Studie) an Abhängigkeit von ihrem Agatston Score rekrutiert und in 5 Gruppen (Gruppe 1: Score 0, Gruppe 2: Score 1 – 100, Gruppe 3: Score 101 – 400, Gruppe 4: Score 401 – 1000, Gruppe 5: Score >1000) eingeteilt. LGE Bilder wurden bei 1,5 T aufgenommen. Die LGE Datensätze wurden von zwei erfahrenen, geblindeten Befundern im Konsens beurteilt. Im Falle eines LGE wurde das Muster des LGE als ischämisch oder nicht-ischämisch klassifiziert. Die Häufigkeit eines LGE wurde für jede Gruppe berechnet. Der Zusammenhang zwischen Häufigkeit eines LGE und dem Agatston Score wurde mittels logistischer Regression analysiert, wobei die Ergebnisse für Alter und Geschlecht adjustiert wurden. Ergebnisse: Ein ischämisches LGE wurde in insgesamt 6% (Gruppe 1: 4%, Gruppe 2: 0%, Gruppe 3: 2%, Gruppe 4: 8%, Gruppe 5: 16%), ein nicht-ischämisches LGE in insgesamt 12% (Gruppe 1: 10%, Gruppe 2: 20%, Gruppe 3: 4%, Gruppe 4: 13%, Gruppe 5: 13%) der Individuen gefunden. Die statistische Analyse zeigte einen positiven Zusammenhang zwischen der Häufigkeit eines ischämischen LGE und dem Agatston Score (OR 1,71, 95% CI 1,01 – 2,89, p = 0,048), aber keinen signifikanten Zusammenhang zwischen der Häufigkeit eines nicht-ischämischen LGE und dem Agatston Score (OR 0,84, 95% CI 0,61 – 1,16, p = 0,29). Schlussfolgerungen: Insgesamt zeigt sich eine hohe Prävalenz eines LGE in unserer asymptomatischen Screening Population, wobei sich insbesondere eine hohe Prävalenz eines nicht-ischämischen LGE beobachten ließ. Einzig die Häufigkeit eines ischämischen LGE Musters zeigte eine Abhängig vom Ausmaß der Koronarverkalkungen. E-Mail: [email protected]
- 22 April 2014
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 186 (S 01) , RK_VO211_3
Häufigkeit eines myokardialen Late Gadolinium Enhancements in Abhängigkeit vom Ausmaß der Koronarverkalkungen in einer asymptomatischen Screening-Population
Zielsetzung: Ziel der vorliegenden Studie war es, den Zusammenhang zwischen der Häufigkeit eines myokardialen Late Gadolinium Enhancements (LGE) und dem Ausmaß von Koronarverkalkungen in einer asymptomatischen Screening-Population zu untersuchen. Material und Methodik: 250 asymptomatische Personen (mittleres Alter 64 ± 7 Jahre) wurden aus dem Kollektiv einer großen Populations-basierten Screening Studie (Heinz Nixdorf Recall Studie) an Abhängigkeit von ihrem Agatston Score rekrutiert und in 5 Gruppen (Gruppe 1: Score 0, Gruppe 2: Score 1 – 100, Gruppe 3: Score 101 – 400, Gruppe 4: Score 401 – 1000, Gruppe 5: Score >1000) eingeteilt. LGE Bilder wurden bei 1,5 T aufgenommen. Die LGE Datensätze wurden von zwei erfahrenen, geblindeten Befundern im Konsens beurteilt. Im Falle eines LGE wurde das Muster des LGE als ischämisch oder nicht-ischämisch klassifiziert. Die Häufigkeit eines LGE wurde für jede Gruppe berechnet. Der Zusammenhang zwischen Häufigkeit eines LGE und dem Agatston Score wurde mittels logistischer Regression analysiert, wobei die Ergebnisse für Alter und Geschlecht adjustiert wurden. Ergebnisse: Ein ischämisches LGE wurde in insgesamt 6% (Gruppe 1: 4%, Gruppe 2: 0%, Gruppe 3: 2%, Gruppe 4: 8%, Gruppe 5: 16%), ein nicht-ischämisches LGE in insgesamt 12% (Gruppe 1: 10%, Gruppe 2: 20%, Gruppe 3: 4%, Gruppe 4: 13%, Gruppe 5: 13%) der Individuen gefunden. Die statistische Analyse zeigte einen positiven Zusammenhang zwischen der Häufigkeit eines ischämischen LGE und dem Agatston Score (OR 1,71, 95% CI 1,01 – 2,89, p = 0,048), aber keinen signifikanten Zusammenhang zwischen der Häufigkeit eines nicht-ischämischen LGE und dem Agatston Score (OR 0,84, 95% CI 0,61 – 1,16, p = 0,29). Schlussfolgerungen: Insgesamt zeigt sich eine hohe Prävalenz eines LGE in unserer asymptomatischen Screening Population, wobei sich insbesondere eine hohe Prävalenz eines nicht-ischämischen LGE beobachten ließ. Einzig die Häufigkeit eines ischämischen LGE Musters zeigte eine Abhängig vom Ausmaß der Koronarverkalkungen. E-Mail: [email protected]
- 1 October 2013
- Vol. 185 (10) , 983-91
MR-guided HIFU treatment of symptomatic uterine fibroids using novel feedback-regulated volumetric ablation: effectiveness and clinical practice.
To evaluate a novel feedback-regulated volumetric sonication method in MRguided HIFU treatment of symptomatic uterine fibroids. 27 fibroids with an average volume of 124.9 ± 139.8 cc in 18 women with symptomatic uterine fibroids were ablated using the new HIFU system Sonalleve (1.5 TMR system Achieva, Philips). 21 myomas in 13 women were reevaluated 6 months later. Standard (treatment) cells (TC) and feedback-regulated (feedback) cells (FC) with a diameter of 4, 8, 12, and 16 mm were used and compared concerning sonication success, diameter of induced necrosis, and maximum achieved temperature. The non-perfused volume ratio (NPV related to myoma volume) was quantified. The fibroid volume was measured before, 1 month, and 6 months after therapy. Symptoms were quantified using a specific questionnaire (UFS-QoL). In total, 205 TC and 227 FC were applied. The NPV ratio was 23 ± 15 % (2 – 55). The TC were slightly smaller than intended (-3.9 ± 52 %; range, -100 – 81), while the FC were 20.1 ± 25.3 % bigger (p = 0.02). Feedback mechanism is less diversifying in diameter (p < 0.001). Overall, the FC correlate well with the planned treatment diameter (r = 0.79), other than the TC (r = 0.38). Six months after therapy, the fibroid volume was reduced by 45 ± 21 % (5 – 100) (p = 0.001). The symptoms decreased significantly (p = 0.001). No serious adverse events were recorded. Use of volumetric sonication leads to homogenous heating and sufficient necrosis. It is a safe and effective therapy for treating symptomatic uterine fibroids. Successful sonication of feedback cells leads to more contiguous necrosis in diameter
- 1 October 2013
- Vol. 185 (10) , 983-91
MR-guided HIFU treatment of symptomatic uterine fibroids using novel feedback-regulated volumetric ablation: effectiveness and clinical practice.
To evaluate a novel feedback-regulated volumetric sonication method in MRguided HIFU treatment of symptomatic uterine fibroids. 27 fibroids with an average volume of 124.9 ± 139.8 cc in 18 women with symptomatic uterine fibroids were ablated using the new HIFU system Sonalleve (1.5 TMR system Achieva, Philips). 21 myomas in 13 women were reevaluated 6 months later. Standard (treatment) cells (TC) and feedback-regulated (feedback) cells (FC) with a diameter of 4, 8, 12, and 16 mm were used and compared concerning sonication success, diameter of induced necrosis, and maximum achieved temperature. The non-perfused volume ratio (NPV related to myoma volume) was quantified. The fibroid volume was measured before, 1 month, and 6 months after therapy. Symptoms were quantified using a specific questionnaire (UFS-QoL). In total, 205 TC and 227 FC were applied. The NPV ratio was 23 ± 15 % (2 – 55). The TC were slightly smaller than intended (-3.9 ± 52 %; range, -100 – 81), while the FC were 20.1 ± 25.3 % bigger (p = 0.02). Feedback mechanism is less diversifying in diameter (p < 0.001). Overall, the FC correlate well with the planned treatment diameter (r = 0.79), other than the TC (r = 0.38). Six months after therapy, the fibroid volume was reduced by 45 ± 21 % (5 – 100) (p = 0.001). The symptoms decreased significantly (p = 0.001). No serious adverse events were recorded. Use of volumetric sonication leads to homogenous heating and sufficient necrosis. It is a safe and effective therapy for treating symptomatic uterine fibroids. Successful sonication of feedback cells leads to more contiguous necrosis in diameter
- 26 April 2013
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 185 (S 01) , VO213_2
Vergleich der gefilterten Rückprojektion und einer Modell-basierten iterativen Rekonstruktion der 4. Generation von peripheren CT-Angiografien
Ziele: Vergleich der gefilterten Rückprojektion (FBP) und der iterativen Rekonstruktion (IR, SAFIRE, Siemens Healthcare AG, Erlangen) von CT-Angiografien (CTA) der Becken-Bein-Gefäße zur Eruierung einer möglichen Strahlendosisreduktion. Methode: 43 Patienten erhielten eine CTA an einem 64-Zeilen MDCT mit BMI-angepasster Röhrenspannung und Röhrenstrom sowie CARE Dose. Verwendete Röhrenparameter waren wie folgt: Gruppe I (n = 15 BMI30 kg/m2) 100 kV/300 mAs. Der Faltungskern war B30f für die FBP und I30f für die IR. Beide Rekonstruktionsalgorithmen wurden hinsichtlich Signalintensität (SI), SNR und diagnostische Bildqualität (5-Punkte-Nominalskala) anhand von Bildschärfe und Gefäßabgrenzbarkeit an 7 definierten Gefäßabschnitten entlang der Becken-Bein-Achse analysiert. Ergebnis: Es zeigte sich keine signifikante SI-Differenz zwischen FBP und IR. Die SI der FBP fiel im Gefäßverlauf von 455 ± 137HU im Segment I (Aorta auf Höhe der Nierenarterien) auf 305 ± 90HU im Segment VII (führendes distales Unterschenkelgefäß) ab, bei IR respektive von 453 ± 140HU auf 304 ± 89HU. Die von proximal nach distal kontinuierlich abfallende SNR war signifikant besser bei der IR im Vergleich zu der FBP in allen drei BMI-Gruppen und in allen Gefäßsegmenten: in der BMI-Gruppe I im Segment I 23,8 ± 7,3 (FBP) vs. 31,8 ± 10,1 (IR p = 0,001) und im Segment VII 11,4 ± 4,4 (FBP) vs. 15 ± 5,7 (IR p = 0,01); in Gruppe II im Segment I 15,9 ± 5,6 (FBP) vs. 23,11 ± 9 (IR) bzw. im Segment VII 12,1 ± 3,9 (FBP) vs. 17,3 ± 5,4 (IR p jeweils Schlussfolgerung: SAFIRE ermöglicht eine subjektiv angenehmere und messbar rauschärmere Bildbetrachtung. Bei fehlendem Einfluss auf die Bildschärfe oder Abgrenzbarkeit von Gefäßen ist die diagnostische Bildqualität gleichbleibend zur FBP. Korrespondierender Autor: May K Universitätsklinikum Schleswig-Holstein, Campus Lübeck, Klinik für Radiologie, Ratzeburger Allee 160, 23538 Lübeck E-Mail: [email protected]
- 26 April 2013
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 185 (S 01) , VO213_2
Vergleich der gefilterten Rückprojektion und einer Modell-basierten iterativen Rekonstruktion der 4. Generation von peripheren CT-Angiografien
Ziele: Vergleich der gefilterten Rückprojektion (FBP) und der iterativen Rekonstruktion (IR, SAFIRE, Siemens Healthcare AG, Erlangen) von CT-Angiografien (CTA) der Becken-Bein-Gefäße zur Eruierung einer möglichen Strahlendosisreduktion. Methode: 43 Patienten erhielten eine CTA an einem 64-Zeilen MDCT mit BMI-angepasster Röhrenspannung und Röhrenstrom sowie CARE Dose. Verwendete Röhrenparameter waren wie folgt: Gruppe I (n = 15 BMI30 kg/m2) 100 kV/300 mAs. Der Faltungskern war B30f für die FBP und I30f für die IR. Beide Rekonstruktionsalgorithmen wurden hinsichtlich Signalintensität (SI), SNR und diagnostische Bildqualität (5-Punkte-Nominalskala) anhand von Bildschärfe und Gefäßabgrenzbarkeit an 7 definierten Gefäßabschnitten entlang der Becken-Bein-Achse analysiert. Ergebnis: Es zeigte sich keine signifikante SI-Differenz zwischen FBP und IR. Die SI der FBP fiel im Gefäßverlauf von 455 ± 137HU im Segment I (Aorta auf Höhe der Nierenarterien) auf 305 ± 90HU im Segment VII (führendes distales Unterschenkelgefäß) ab, bei IR respektive von 453 ± 140HU auf 304 ± 89HU. Die von proximal nach distal kontinuierlich abfallende SNR war signifikant besser bei der IR im Vergleich zu der FBP in allen drei BMI-Gruppen und in allen Gefäßsegmenten: in der BMI-Gruppe I im Segment I 23,8 ± 7,3 (FBP) vs. 31,8 ± 10,1 (IR p = 0,001) und im Segment VII 11,4 ± 4,4 (FBP) vs. 15 ± 5,7 (IR p = 0,01); in Gruppe II im Segment I 15,9 ± 5,6 (FBP) vs. 23,11 ± 9 (IR) bzw. im Segment VII 12,1 ± 3,9 (FBP) vs. 17,3 ± 5,4 (IR p jeweils Schlussfolgerung: SAFIRE ermöglicht eine subjektiv angenehmere und messbar rauschärmere Bildbetrachtung. Bei fehlendem Einfluss auf die Bildschärfe oder Abgrenzbarkeit von Gefäßen ist die diagnostische Bildqualität gleichbleibend zur FBP. Korrespondierender Autor: May K Universitätsklinikum Schleswig-Holstein, Campus Lübeck, Klinik für Radiologie, Ratzeburger Allee 160, 23538 Lübeck E-Mail: [email protected]
- 18 June 2012
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 184 (08) , 697-705
Der dicke linke Ventrikel: Ursachen und Differenzialdiagnose der linksventrikulären Hypertrophie und Implikationen für die kardiovaskuläre Radiologie
Verdickte linke Ventrikelwände sind ein häufiger Befund, der echokardiografisch, computertomografisch und kernspintomografisch zuverlässig nachgewiesen werden kann. Zu den häufigen Ursachen zählen alle Erkrankungen, die mit einer Nachlasterhöhung einhergehen, sowie primäre und sekundäre Kardiomyopathien. Durch die Möglichkeit, sowohl funktionelle Parameter des linken Ventrikels als auch die myokardiale Masse exakt zu bestimmen und gleichzeitig strukturelle Veränderungen des Herzmuskels nachzuweisen, ist die kardiale MRT die beste bildgebende Methode zur Quantifizierung der linksventrikulären Hypertrophie, zur Abklärung der Ursache und zur Charakterisierung der myokardialen Veränderungen. Bei der kardialen MRT ist hierzu jedoch ein flexibles, an die individuellen Befunde angepasstes Untersuchungsprotokoll erforderlich. In dieser Übersichtsarbeit werden die unterschiedlichen zugrunde liegenden Erkrankungen ausführlich beschrieben und sinnvolle diagnostische Algorithmen bei Patienten mit linksventrikulärer Hypertrophie vorgestellt. Hypertrophy of the left ventricular myocardium is a common finding and can be reliably detected by echocardiography, CT and MRI. Common causes include diseases associated with increased cardiac afterload as well as primary and secondary cardiomyopathy. With the opportunity to determine functional parameters and myocardial mass precisely as well as to detect structural changes of the cardiac muscle simultaneously, cardiac MRI is the most precise imaging method for quantifying left ventricular hypertrophy as well as determining the cause and the exact characterization of the myocardial changes. It is mandatory, however, to create a flexible, individually adapted examination protocol. This review presents useful diagnostic algorithms in relation to different underlying pathologies in patients with left ventricular hypertrophy.
- 18 June 2012
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 184 (08) , 697-705
Der dicke linke Ventrikel: Ursachen und Differenzialdiagnose der linksventrikulären Hypertrophie und Implikationen für die kardiovaskuläre Radiologie
Verdickte linke Ventrikelwände sind ein häufiger Befund, der echokardiografisch, computertomografisch und kernspintomografisch zuverlässig nachgewiesen werden kann. Zu den häufigen Ursachen zählen alle Erkrankungen, die mit einer Nachlasterhöhung einhergehen, sowie primäre und sekundäre Kardiomyopathien. Durch die Möglichkeit, sowohl funktionelle Parameter des linken Ventrikels als auch die myokardiale Masse exakt zu bestimmen und gleichzeitig strukturelle Veränderungen des Herzmuskels nachzuweisen, ist die kardiale MRT die beste bildgebende Methode zur Quantifizierung der linksventrikulären Hypertrophie, zur Abklärung der Ursache und zur Charakterisierung der myokardialen Veränderungen. Bei der kardialen MRT ist hierzu jedoch ein flexibles, an die individuellen Befunde angepasstes Untersuchungsprotokoll erforderlich. In dieser Übersichtsarbeit werden die unterschiedlichen zugrunde liegenden Erkrankungen ausführlich beschrieben und sinnvolle diagnostische Algorithmen bei Patienten mit linksventrikulärer Hypertrophie vorgestellt. Hypertrophy of the left ventricular myocardium is a common finding and can be reliably detected by echocardiography, CT and MRI. Common causes include diseases associated with increased cardiac afterload as well as primary and secondary cardiomyopathy. With the opportunity to determine functional parameters and myocardial mass precisely as well as to detect structural changes of the cardiac muscle simultaneously, cardiac MRI is the most precise imaging method for quantifying left ventricular hypertrophy as well as determining the cause and the exact characterization of the myocardial changes. It is mandatory, however, to create a flexible, individually adapted examination protocol. This review presents useful diagnostic algorithms in relation to different underlying pathologies in patients with left ventricular hypertrophy.
- 25 April 2012
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 184 (S 01) , VO216_4
Digitale Tomosynthese - Ein neues Verfahren zur Beurteilung degenerativer Gelenkveränderungen im Vergleich zum konventionellen Röntgen
Ziele: Ziel dieser Studie war die Evaluation des Potenzials der digitalen Tomosynthese als bildgebendes Verfahren zum Nachweis von degenerativen Gelenkveränderungen und zystischen Knochenläsionen der Hand im Vergleich zum konventionellen Röntgen (CR). Methode: Es wurden 30Hände von Körperspendern konventionell geröntgt. Zusätzlich wurden die Hände mittels Tomosynthese untersucht. Die Hände wurden in paralleler Lage zur Bewegungsachse der Röntgenröhre platziert und bei einer Röhrenspannung von 35kV und 125mAs an einem digitalen Mammatomosynthesegerät untersucht. Über einen Schwenkbereich der Röntgenröhre von ±25° wurden 25 Projektionen angefertigt und daraus ein Stapel von hochaufgelösten Schichtbildern (Schichtabstand 1mm) berechnet. Als Referenzstandard dienten hochauflösende CT Untersuchungen (0,75mm Schichtdicke). Im Anschluss wurden die Studien hinsichtlich der detektierten Läsionen von drei erfahrenen Radiologen jeweils quantitativ ausgewertet. Ergebnis: Bei 20/30Händen konnten degenerative Gelenkveränderungen und zystischen Knochenläsionen detektiert werden. In der CT wurden 87 zystische und 44 degenerative Läsionen nachgewiesen. Die Tomosynthese zeigte eine hochauflösende Darstellung der Knochenrandzonen und Gelenkspalte sowie kleinste Knochenzysten mit einem Durchmesser Schlussfolgerung: Die Tomosynthese ist dem CR in der Detektion von kleinsten Knochenläsionen und von degenerativen Gelenkveränderungen deutlich überlegen. Zusätzliche Studien zur Eignung der Tomosynthese als klinische Routineuntersuchung im Follow-up von entzündlichen und degenerativen Gelenkerkrankungen sind notwendig. Keywords: Tomosynthese, CT, Röntgen, degenerativ, Knochenläsion Korrespondierender Autor: Duschka RL Universitätsklinik Schleswig-Holstein, Klinik für Radiologie und Nuklearmedizin, Ratzeburger Allee 160, 23538 Lübeck E-Mail: robert.duschka@uksh.de
- 25 April 2012
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 184 (S 01) , VO216_4
Digitale Tomosynthese - Ein neues Verfahren zur Beurteilung degenerativer Gelenkveränderungen im Vergleich zum konventionellen Röntgen
Ziele: Ziel dieser Studie war die Evaluation des Potenzials der digitalen Tomosynthese als bildgebendes Verfahren zum Nachweis von degenerativen Gelenkveränderungen und zystischen Knochenläsionen der Hand im Vergleich zum konventionellen Röntgen (CR). Methode: Es wurden 30Hände von Körperspendern konventionell geröntgt. Zusätzlich wurden die Hände mittels Tomosynthese untersucht. Die Hände wurden in paralleler Lage zur Bewegungsachse der Röntgenröhre platziert und bei einer Röhrenspannung von 35kV und 125mAs an einem digitalen Mammatomosynthesegerät untersucht. Über einen Schwenkbereich der Röntgenröhre von ±25° wurden 25 Projektionen angefertigt und daraus ein Stapel von hochaufgelösten Schichtbildern (Schichtabstand 1mm) berechnet. Als Referenzstandard dienten hochauflösende CT Untersuchungen (0,75mm Schichtdicke). Im Anschluss wurden die Studien hinsichtlich der detektierten Läsionen von drei erfahrenen Radiologen jeweils quantitativ ausgewertet. Ergebnis: Bei 20/30Händen konnten degenerative Gelenkveränderungen und zystischen Knochenläsionen detektiert werden. In der CT wurden 87 zystische und 44 degenerative Läsionen nachgewiesen. Die Tomosynthese zeigte eine hochauflösende Darstellung der Knochenrandzonen und Gelenkspalte sowie kleinste Knochenzysten mit einem Durchmesser Schlussfolgerung: Die Tomosynthese ist dem CR in der Detektion von kleinsten Knochenläsionen und von degenerativen Gelenkveränderungen deutlich überlegen. Zusätzliche Studien zur Eignung der Tomosynthese als klinische Routineuntersuchung im Follow-up von entzündlichen und degenerativen Gelenkerkrankungen sind notwendig. Keywords: Tomosynthese, CT, Röntgen, degenerativ, Knochenläsion Korrespondierender Autor: Duschka RL Universitätsklinik Schleswig-Holstein, Klinik für Radiologie und Nuklearmedizin, Ratzeburger Allee 160, 23538 Lübeck E-Mail: robert.duschka@uksh.de
- 25 April 2012
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 184 (S 01) , RK201_1
Myokardhypertrophie - Untersuchungsprotokolle und Differentialdiagnosen
Die Hypertrophie des linksventrikulären Myokards ist ein häufiger Befund der echokardiografisch, computertomografisch und kernspintomografisch zuverlässig nachgewiesen werden kann. Zu den häufigen Ursachen zählen alle Erkrankungen die mit einer Nachlasterhöhung einhergehen sowie primäre und sekundäre Kardiomyopathien. Durch die Möglichkeit sowohl funktioneller Parameter als auch die myokardiale Masse exakt zu bestimmen und gleichzeitig strukturelle Veränderungen des Herzmuskels nachzuweisen, ist die kardiale MRT die beste bildgebende Methode zur Quantifizierung der linksventrikulären Hypertrophie, zur Abklärung der Ursache und zur exakten Charakterisierung der myokardialen Veränderungen. Bei der kardialen MRT ist hierzu jedoch ein flexibles, an die individuellen Befunde angepasstes Untersuchungsprotokoll erforderlich. Im Vortrag werden sinnvolle diagnostische Algorithmen bei Patienten mit linksventrikulärer Hypertrophie vorgestellt und die unterschiedlichen zugrunde liegenden Erkrankungen und deren Differentialdiagnosen ausführlich dargestellt. Lernziele: Korrespondierender Autor: Barkhausen J Universitätsklinikum Schleswig-Holstein, Campus Lübeck, Klinik für Radiologie und Nuklearmedizin, Ratzeburger Allee 160, 23538 Lübeck E-Mail: joerg.barkhausen@uk-sh.de
- 25 April 2012
- Published by Georg Thieme Verlag KG in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
- Vol. 184 (S 01) , RK201_1
Myokardhypertrophie - Untersuchungsprotokolle und Differentialdiagnosen
Die Hypertrophie des linksventrikulären Myokards ist ein häufiger Befund der echokardiografisch, computertomografisch und kernspintomografisch zuverlässig nachgewiesen werden kann. Zu den häufigen Ursachen zählen alle Erkrankungen die mit einer Nachlasterhöhung einhergehen sowie primäre und sekundäre Kardiomyopathien. Durch die Möglichkeit sowohl funktioneller Parameter als auch die myokardiale Masse exakt zu bestimmen und gleichzeitig strukturelle Veränderungen des Herzmuskels nachzuweisen, ist die kardiale MRT die beste bildgebende Methode zur Quantifizierung der linksventrikulären Hypertrophie, zur Abklärung der Ursache und zur exakten Charakterisierung der myokardialen Veränderungen. Bei der kardialen MRT ist hierzu jedoch ein flexibles, an die individuellen Befunde angepasstes Untersuchungsprotokoll erforderlich. Im Vortrag werden sinnvolle diagnostische Algorithmen bei Patienten mit linksventrikulärer Hypertrophie vorgestellt und die unterschiedlichen zugrunde liegenden Erkrankungen und deren Differentialdiagnosen ausführlich dargestellt. Lernziele: Korrespondierender Autor: Barkhausen J Universitätsklinikum Schleswig-Holstein, Campus Lübeck, Klinik für Radiologie und Nuklearmedizin, Ratzeburger Allee 160, 23538 Lübeck E-Mail: joerg.barkhausen@uk-sh.de