Latest Publications
- 1 December 2012
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 17 (6) , 257-258
Are kiosk blood pressure readings trustworthy?
- 1 December 2012
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 17 (6) , 257-258
Are kiosk blood pressure readings trustworthy?
- 1 October 2012
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 17 (5) , 207-209
Validation of the Nihon Kohden PVM-2701/Impulse-1 automated device by both AAMI (2002) and ISO standards testing
We evaluated a new algorithm, the Nihon Kohden PVM-2701/Impulse-1, in an automated sphygmomanometer against the requirements of both the Association for the Advancement of Medical Instrumentation (AAMI) SP10 and International Standards Organization (ISO) standards. The Impulse-1 algorithm primarily utilizes a 1 pulse/step deflation. The advantage of the system is to reduce the time of deflation and improve patient comfort. We tested 110 participants (41 children) to fulfill the Standards requirements. We used the more up-to-date statistical analyses in the ISO standard. The mean ± SD for method 1 analyses for systolic blood pressure was 0.3 ± 6.5 mmHg. For diastolic blood pressure the value was -0.3 ± 7.7 mmHg. Method 2 analyses gave values of 0.3 ± 5.2 mmHg for systolic blood pressure and -0.3 ± 6.7 mmHg for diastolic blood pressure. All of the data were within the Standards requirements to pass testing. There was no trend for overestimation or underestimation of BP at either low or high BP levels. The Impulse-1 algorithm passed both the AAMI and ISO standards testing in children and adults. The novelties of the 1 pulse/step deflation algorithm are the significant reduction in deflation time and the manufacturer's claim concerning artifact rejection for both dysrhythmia and motion.
- 1 October 2012
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 17 (5) , 207-209
Validation of the Nihon Kohden PVM-2701/Impulse-1 automated device by both AAMI (2002) and ISO standards testing
We evaluated a new algorithm, the Nihon Kohden PVM-2701/Impulse-1, in an automated sphygmomanometer against the requirements of both the Association for the Advancement of Medical Instrumentation (AAMI) SP10 and International Standards Organization (ISO) standards. The Impulse-1 algorithm primarily utilizes a 1 pulse/step deflation. The advantage of the system is to reduce the time of deflation and improve patient comfort. We tested 110 participants (41 children) to fulfill the Standards requirements. We used the more up-to-date statistical analyses in the ISO standard. The mean ± SD for method 1 analyses for systolic blood pressure was 0.3 ± 6.5 mmHg. For diastolic blood pressure the value was -0.3 ± 7.7 mmHg. Method 2 analyses gave values of 0.3 ± 5.2 mmHg for systolic blood pressure and -0.3 ± 6.7 mmHg for diastolic blood pressure. All of the data were within the Standards requirements to pass testing. There was no trend for overestimation or underestimation of BP at either low or high BP levels. The Impulse-1 algorithm passed both the AAMI and ISO standards testing in children and adults. The novelties of the 1 pulse/step deflation algorithm are the significant reduction in deflation time and the manufacturer's claim concerning artifact rejection for both dysrhythmia and motion.
- 1 June 2011
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 16 (3) , 156-158
Validation of the Welch Allyn ProBP 3400
As medical care evolves, automated sphygmomanometers must be able to provide accurate and timely blood pressure (BP) data to the healthcare provider. We evaluated the performance of a new hand-held, battery-operated device, the Welch Allyn ProBP 3400, to the AAMI SP 10 criteria. We also performed British Hypertension Society data analysis. A total of 111 (97 adults, 14 children) participants were tested using blinded and paired observers performing auscultation of Korotkoff (K1 and K5) sounds. Ninety-two participants had acceptable data, giving 275 paired data sets for systolic BP (SBP) and diastolic BP (DBP) analyses. The mean ± standard deviation of the observer/device differences were -1.1 ± 7.5 mmHg for SBP and -2.1 ± 6.0 mmHg for DBP. These passed the AAMI SP10 requirements. The ProBP 3400 achieved an A grade for both SBP and DBP. The ProBP 3400 passed the AAMI standard requirements and achieved A grade for both SBP and DBP. The device is less in cost and completely portable. It transmits BP data directly into the electronic medical record using a Universal Serial Bus connection. These features will improve the efficiency and accuracy of BP data available to clinicians, thus improving the quality of care.
- 1 June 2011
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 16 (3) , 156-158
Validation of the Welch Allyn ProBP 3400
As medical care evolves, automated sphygmomanometers must be able to provide accurate and timely blood pressure (BP) data to the healthcare provider. We evaluated the performance of a new hand-held, battery-operated device, the Welch Allyn ProBP 3400, to the AAMI SP 10 criteria. We also performed British Hypertension Society data analysis. A total of 111 (97 adults, 14 children) participants were tested using blinded and paired observers performing auscultation of Korotkoff (K1 and K5) sounds. Ninety-two participants had acceptable data, giving 275 paired data sets for systolic BP (SBP) and diastolic BP (DBP) analyses. The mean ± standard deviation of the observer/device differences were -1.1 ± 7.5 mmHg for SBP and -2.1 ± 6.0 mmHg for DBP. These passed the AAMI SP10 requirements. The ProBP 3400 achieved an A grade for both SBP and DBP. The ProBP 3400 passed the AAMI standard requirements and achieved A grade for both SBP and DBP. The device is less in cost and completely portable. It transmits BP data directly into the electronic medical record using a Universal Serial Bus connection. These features will improve the efficiency and accuracy of BP data available to clinicians, thus improving the quality of care.
- 1 April 2011
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 16 (2) , 96-98
Validation of the Welch Allyn SureBP (inflation) and StepBP (deflation) algorithms by AAMI standard testing and BHS data analysis
We evaluated two new Welch Allyn automated blood pressure (BP) algorithms. The first, SureBP, estimates BP during cuff inflation; the second, StepBP, does so during deflation. We followed the American National Standards Institute/Association for the Advancement of Medical Instrumentation SP10:2006 standard for testing and data analysis. The data were also analyzed using the British Hypertension Society analysis strategy. We tested children, adolescents, and adults. The requirements of the American National Standards Institute/Association for the Advancement of Medical Instrumentation SP10:2006 standard were fulfilled with respect to BP levels, arm sizes, and ages. Association for the Advancement of Medical Instrumentation SP10 Method 1 data analysis was used. The mean±standard deviation for the device readings compared with auscultation by paired, trained, blinded observers in the SureBP mode were -2.14±7.44 mmHg for systolic BP (SBP) and -0.55±5.98 mmHg for diastolic BP (DBP). In the StepBP mode, the differences were -3.61±6.30 mmHg for SBP and -2.03±5.30 mmHg for DBP. Both algorithms achieved an A grade for both SBP and DBP by British Hypertension Society analysis. The SureBP inflation-based algorithm will be available in many new-generation Welch Allyn monitors. Its use will reduce the time it takes to estimate BP in critical patient care circumstances. The device will not need to inflate to excessive suprasystolic BPs to obtain the SBP values. Deflation is rapid once SBP has been determined, thus reducing the total time of cuff inflation and reducing patient discomfort. If the SureBP fails to obtain a BP value, the StepBP algorithm is activated to estimate BP by traditional deflation methodology.
- 1 April 2011
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 16 (2) , 96-98
Validation of the Welch Allyn SureBP (inflation) and StepBP (deflation) algorithms by AAMI standard testing and BHS data analysis
We evaluated two new Welch Allyn automated blood pressure (BP) algorithms. The first, SureBP, estimates BP during cuff inflation; the second, StepBP, does so during deflation. We followed the American National Standards Institute/Association for the Advancement of Medical Instrumentation SP10:2006 standard for testing and data analysis. The data were also analyzed using the British Hypertension Society analysis strategy. We tested children, adolescents, and adults. The requirements of the American National Standards Institute/Association for the Advancement of Medical Instrumentation SP10:2006 standard were fulfilled with respect to BP levels, arm sizes, and ages. Association for the Advancement of Medical Instrumentation SP10 Method 1 data analysis was used. The mean±standard deviation for the device readings compared with auscultation by paired, trained, blinded observers in the SureBP mode were -2.14±7.44 mmHg for systolic BP (SBP) and -0.55±5.98 mmHg for diastolic BP (DBP). In the StepBP mode, the differences were -3.61±6.30 mmHg for SBP and -2.03±5.30 mmHg for DBP. Both algorithms achieved an A grade for both SBP and DBP by British Hypertension Society analysis. The SureBP inflation-based algorithm will be available in many new-generation Welch Allyn monitors. Its use will reduce the time it takes to estimate BP in critical patient care circumstances. The device will not need to inflate to excessive suprasystolic BPs to obtain the SBP values. Deflation is rapid once SBP has been determined, thus reducing the total time of cuff inflation and reducing patient discomfort. If the SureBP fails to obtain a BP value, the StepBP algorithm is activated to estimate BP by traditional deflation methodology.
- 1 October 2010
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 15 (5) , 275-277
Validation of the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor to the ISO Standard and BHS protocol
We evaluated the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor accuracy by both the International Standards Organization (ISO) Standard and the British Hypertension Society (BHS) protocol. We tested children, adolescents, and adults. The requirements for both ISO and BHS were completed for 85 individuals each. The Ambulo 2400 passed both ISO and BHS criteria. For ISO method 1, the mean±SD for the difference between device and manual systolic blood pressure (SBP) was −1.8±6.5 mmHg; for diastolic blood pressure (DBP) the values were 0.7±7.3 mmHg. For the method 2 analyses, the differences were −1.8±4.7 and 0.7±6.3 mmHg for SBP and DBP, respectively. The percentage of differences within 5, 10, and 15 mmHg were 60, 86, and 98% for SBP, and 60, 85, and 96% for DBP. The Ambulo 2400 passed all phases of the ISO testing and achieved an A grade for both SBP and DBP per BHS analyses. There was no decrease in accuracy in either high or low BP ranges. The Ambulo 2400 integrates activity monitoring for assigning actual awake and asleep times. There are software features that are particularly beneficial to monitor children and adolescents.
- 1 October 2010
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 15 (5) , 275-277
Validation of the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor to the ISO Standard and BHS protocol
We evaluated the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor accuracy by both the International Standards Organization (ISO) Standard and the British Hypertension Society (BHS) protocol. We tested children, adolescents, and adults. The requirements for both ISO and BHS were completed for 85 individuals each. The Ambulo 2400 passed both ISO and BHS criteria. For ISO method 1, the mean±SD for the difference between device and manual systolic blood pressure (SBP) was −1.8±6.5 mmHg; for diastolic blood pressure (DBP) the values were 0.7±7.3 mmHg. For the method 2 analyses, the differences were −1.8±4.7 and 0.7±6.3 mmHg for SBP and DBP, respectively. The percentage of differences within 5, 10, and 15 mmHg were 60, 86, and 98% for SBP, and 60, 85, and 96% for DBP. The Ambulo 2400 passed all phases of the ISO testing and achieved an A grade for both SBP and DBP per BHS analyses. There was no decrease in accuracy in either high or low BP ranges. The Ambulo 2400 integrates activity monitoring for assigning actual awake and asleep times. There are software features that are particularly beneficial to monitor children and adolescents.
- 1 January 2010
- p. 69-72
AAMI blood pressure device standard targets home use issues.
In this article, leaders of the AAMI Sphygmomanometer Committee report on their efforts to address home use issues in standards for blood pressure devices, and the importance of standards to ensuring safety and effectiveness of home use devices.
- 1 January 2010
- p. 69-72
AAMI blood pressure device standard targets home use issues.
In this article, leaders of the AAMI Sphygmomanometer Committee report on their efforts to address home use issues in standards for blood pressure devices, and the importance of standards to ensuring safety and effectiveness of home use devices.