BCBai-Chuan Cao

Bai-Chuan Cao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bai-Chuan Cao has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Bao-Yu Gao

    School of Environmental Science and Engineering, Shandong University , No. 27 Shanda South Road, Jinan , 250100 , Shandong , P.R.China Phone: Tel. +86 531 88364832 Fax: Tel. +86 531 88364832

    3 shared publications
  • Lei Lu

    School of Environmental Science and Engineering, Shandong University, Ji'nan 250100, China

    3 shared publications
  • Chunhua Xu

    Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, Qingdao 266237, China

    2 shared publications
  • Qin-Yan Yue

    Shandong Key Laboratory of Water Pollution Control and Resource Reuse, School of Environmental Science and Engineering, Shandong University, No. 27 Shanda South Road, Jinan 250100, China

    2 shared publications
  • Qinyan Yue

    School of Environmental Science and Engineering, Shandong University, No.27 Shanda South Road, Jinan 250100, Shandong, China

    2 shared publications
  • Baoyu Gao

    1 shared publication

Latest Publications

  • Evaluation of dynamic membrane formation and filtration models at constant pressure in a combined coagulation/dynamic membrane process in treating polluted river water

    by Chunhua Xu, Baoyu Gao, Baichuan Cao, Dandan Cheng, Qinyan Yue

    In this study, a dynamic membrane (DM) was formed by flocs produced by river water pollutants reacting with polyaluminum chloride (PAC). The DM was used to separate the flocs from the mixed liquor at constant pressure. Two support media for the DM were tested: non-woven fabric filter and dacron mesh. The formation time of the DM was determined according to the critical flux. The formation process and filtration mechanisms were evaluated based on typical crossflow membrane fouling models and combinations of them. When a non-woven fabric filter was used as the support media, the formation time of the DM was 70 min at 4 cm water head drop (WHD) and 20 min at 8 cm WHD. When dacron mesh was used as the support media, the membrane formation required 100 min at 4 cm WHD and 70 min at 8 cm WHD. During DM formation on a non-woven fabric filter, the internal pore blocking plays the dominant role. But when dacron mesh is used as the support media, complete blocking and intermediate blocking dominate. After the formation of a DM, the combined models have good agreement with the experimental data compared with the typical filtration models.


  • The impact of pH on floc structure characteristic of polyferric chloride in a low DOC and high alkalinity surface water treatment

    by Baichuan Cao, Baoyu Gao, Xin Liu, Mengmeng Wang, Zhonglian Yang, Qinyan Yue


    • 1 October 2010
      • Vol. 31  (10) , 2349-53

    [Treatment of simulated produced wastewater from polymer flooding in oil production using dithiocarbamate-type flocculant].

    by Yue Gao, Yu-Yan Jia, Bao-Yu Gao, Bai-Chuan Cao, Yong-Qiang Zhang, Lei Lu

    A dithiocarbamate flocculant, DTC (T403), was prepared by the reaction of amine-terminated polyoxypropane-ether compound known as Jeffamine-T403 and carbon disulfide in alkaline solution. The oil removal efficiency of DTC (T403) for simulated produced wastewater from polymer flooding in oil production was studied by Jar-test. The effect of the dosage of DTC (T403), hydrolyzed polyacrylamide (HPAM), Fe2+ and Fe3+ ions, and pH on the oil removal efficiency of DTC (T403) was investigated. The results showed that the chelate polymer formed by DTC (T403) and Fe2+ ion has good oil removal performance by net capturing mechanism. HPAM had a negative effect on oil removal efficiency of DTC (T403). For the treatment of the simulated wastewater containing 0-900 mg/L of HPAM and 300 mg/L of oil, the residual oil concentrations in water samples decreased below 10 mg/L when the dosage of Fe2+ and DTC (T403) was 10 mg/L and 25 mg/L, respectively. The oil removal efficiency of DTC (T403) was affected by pH and good oil removal efficiency was obtained when the pH was below 7.5. DTC (T403) is appropriate for the treatment of oily wastewater containing Fe2+ ion.

    • 1 September 2007
      • Vol. 28  (9) , 2035-40

    [Municipal wastewater treatment using a composite flocculant made of polyaluminum chloride and polydimethyldiallyammonium chloride].

    by Lei Lu, Bao-Yu Gao, Chun-Hua Xu, Qin-Yan Yue, Bai-Chuan Cao, Shi-Ping Xu, Wei-Wei Li

    A composite flocculant (denoted JYF-1), made of polyaluminum chloride (PAC) and polydimethyldiallyammonium chloride (PDMDAAC), was used in jar-tests to simulate the chemically enhanced primary treatment (CEPT) for municipal wastewater. Removal of particles, organic compounds, nitrogen and phosphorus in wastewater was investigated, and the effects of pH and surface overflow rate (SOR) on flocculation were also examined. Electrical charge and distribution of particles in wastewater were analyzed before and after flocculation. Furthermore, the flocculation mechanism and application of JYF-1 in CEPT were discussed. The results demonstrate that JYF-1 performs better than PAC under a wide pH and SOR range. When 8 mg x L(-1) JYF-1 is added, 76.72% COD and 64.31% soluble COD (SCOD) can be removed. About 90% soluble TP (STP), 80% TP and 20% TN can be removed by addition of 12 mg x L(-1) JYF-1. After flocculation, the BOD/COD ratio increases from 0.23 to 0.53, which indicates the biodegradation ability of wastewater is improved. It can be concluded that JYF-1 is a high-efficiency low-cost flocculant, which can improve outlet water quality and produce less sludge without changing the existing equipments and treating process in sewage plants.

    • 1 April 2007
      • Vol. 28  (4) , 761-5

    [Flocculation of wastewater produced in polymer flooding].

    by Lei Lu, Bao-Yu Gao, Qin-Yan Yue, Bai-Chuan Cao

    The particle size distribution, flocculation index, Zeta potential and oil content in water were tested during flocculation of wastewater produced in polymer flooding of oil field. CHP-03, a mixture of a modified pluronic demulsifer and a weak-cationic flocculant, was used to improve the efficiency of oil droplet collision. The effects of polyacrylamide, temperature, and mixing speed on flocculation dynamics are discussed. Polyacrylamide affects the oil-water separation by obstructing the aggregation of small oil droplets, but electrostatic repulsion is not a major factor in preventing flocculation. The local temperature has a limited effect on flocculation. Fast mixing favors the growth of flocs, while slow mixing is suitable for the coalescence of oil droplets. Addition of 250 mg/L CHP-03 can enhance the oil-water separation and remove 92% of the oil content.