Robert Souffrant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robert Souffrant has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Rainer Bader
Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
6 shared publications - Daniel Kluess
Department of Orthopaedics, Rostock University Medical Center, Rostock, Germany
4 shared publications - Sven Herrmann
University Medicine Rostock
4 shared publications - Christoph Woernle
Chair of Technical Dynamics, University of Rostock, Justus-von-Liebig-Weg 6, 18059, Rostock, Germany
3 shared publications - János Zierath
W2e Wind to Energy GmbH, Rostock, Germany
3 shared publications - Michael Kähler
University of Rostock
3 shared publications
Latest Publications
- 6 November 2012
- Published by Springer Nature
- p. 145-160
Robot-Based Testing of Total Joint Replacements
- 6 November 2012
- Published by Springer Nature
- p. 145-160
Robot-Based Testing of Total Joint Replacements
- 1 August 2012
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 15 (8) , 787-793
Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability
Primary stability of artificial acetabular cups, used for total hip arthroplasty, is required for the subsequent osteointegration and good long-term clinical results of the implant. Although closed-cell polymer foams represent an adequate bone substitute in experimental studies investigating primary stability, correct numerical modelling of this material depends on the parameter selection. Material parameters necessary for crushable foam plasticity behaviour were originated from numerical simulations matched with experimental tests of the polymethacrylimide raw material. Experimental primary stability tests of acetabular press-fit cups consisting of static shell assembly with consecutively pull-out and lever-out testing were subsequently simulated using finite element analysis. Identified and optimised parameters allowed the accurate numerical reproduction of the raw material tests. Correlation between experimental tests and the numerical simulation of primary implant stability depended on the value of interference fit. However, the validated material model provides the opportunity for subsequent parametric numerical studies.
- 1 August 2012
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 15 (8) , 787-793
Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability
Primary stability of artificial acetabular cups, used for total hip arthroplasty, is required for the subsequent osteointegration and good long-term clinical results of the implant. Although closed-cell polymer foams represent an adequate bone substitute in experimental studies investigating primary stability, correct numerical modelling of this material depends on the parameter selection. Material parameters necessary for crushable foam plasticity behaviour were originated from numerical simulations matched with experimental tests of the polymethacrylimide raw material. Experimental primary stability tests of acetabular press-fit cups consisting of static shell assembly with consecutively pull-out and lever-out testing were subsequently simulated using finite element analysis. Identified and optimised parameters allowed the accurate numerical reproduction of the raw material tests. Correlation between experimental tests and the numerical simulation of primary implant stability depended on the value of interference fit. However, the validated material model provides the opportunity for subsequent parametric numerical studies.
- 11 January 2012
- Published by Springer Nature in Multibody System Dynamics
- Vol. 28 (1-2) , 55-67
HiL simulation for testing joint stability after total knee arthroplasty
- 11 January 2012
- Published by Springer Nature in Multibody System Dynamics
- Vol. 28 (1-2) , 55-67
HiL simulation for testing joint stability after total knee arthroplasty
- 6 January 2012
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 57 (SI-1 Track) , 809-811
Development of a testing method for the determination of interfacial micromotions of short-stemmed hip endoprosthesis
- 6 January 2012
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 57 (SI-1 Track) , 809-811
Development of a testing method for the determination of interfacial micromotions of short-stemmed hip endoprosthesis