EPElisabeth Peregrine

Elisabeth Peregrine

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Elisabeth Peregrine has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Impact on Delivery Outcome of Ultrasonographic Fetal Head Position Prior to Induction of Labor

    by Elisabeth Peregrine, Patrick O’brien, Eric Jauniaux

    To assess clinical and sonographic fetal head position before induction of labor, position at delivery, and whether occiput posterior (OP) position is associated with adverse delivery outcome. Abdominal palpation and ultrasonographic fetal head and spine position were determined at 36 weeks or more of gestation in 289 women immediately before induction of labor and the head position at delivery noted. Chi-square, Mann-Whitney U tests, and logistic regression were used to assess whether OP position was associated with cesarean delivery. Ninety-seven (36%) of 270 women with full outcome data had an OP position on ultrasonography before induction of labor. Of these 97 women, eight (8%) were OP at delivery. Sixty-eight percent of the 25 OP positions at delivery occurred due to a mal-rotation from a non-OP position during labor. Logistic regression showed that OP position before induction of labor was not an independent predictor of cesarean delivery (odds ratio 1.75, 95% confidence interval 0.97-3.15, P=.06). Two thirds of OP positions at delivery after induction of labor occur due to a mal-rotation in labor from a non-OP position. Ultrasonography is an easy method of assessing fetal head position before induction of labor. In clinical practice, its usefulness is limited by the fact that, contrary to conventional teaching, OP position before induction of labor does not appear to be associated with an increased risk of cesarean delivery. II.


  • Clinical and ultrasound estimation of birth weight prior to induction of labor at term

    by E. Peregrine, P. O'Brien, E. Jauniaux

    Objectives: To assess and compare the accuracy of clinical and sonographic fetal weight estimation in predicting birth weight prior to induction of labor.Methods: In a prospective study of 262 women immediately prior to induction of labor, the fetal weight was estimated clinically by both the doctor (DR EFW) and the woman herself (WM EFW). A transabdominal scan was then performed to estimate the fetal weight sonographically using two different formulae—Shepard (SHEP EFW) and Hadlock (HAD EFW). The four estimated fetal weights were compared with the actual birth weight.Results: The mean percentage error was − 1.9 ± 9.3% for DR EFW, − 3.4 ± 12.6% for WM EFW, − 2.3 ± 11.6% for SHEP EFW and − 7.6 ± 10.6% for HAD EFW. All four EFWs were significantly different from birth weight (t = − 4.7, − 5.5, − 3.5 and − 11.4, respectively, all P < 0.01). The corresponding proportion of the EFWs which were within 10% of birth weight were 71%, 59%, 62% and 42%, respectively. The sensitivity and specificity of detecting a fetus weighing < 3000 g were 56% and 98% for DR EFW, 90% and 89% for WM EFW, 93% and 83% for SHEP EFW and 100% and 76% for HAD EFW. The corresponding values for detecting a fetus weighing > 4000 g were 16% and 99%, 29% and 96%, 48% and 92% and 40% and 94%, respectively.Conclusions: Although, in general, clinical estimates of birth weight perform favorably compared with ultrasonographic estimates, ultrasound immediately prior to labor is more accurate at predicting the low‐ or high‐birth‐weight fetus. Copyright © 2007 ISUOG. Published by John Wiley & Sons, Ltd.